UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Similar documents
UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Instructions

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

UL AND CODE COMPLIANCE

SURE-LITES FBP140XLP Instruction Manual

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Cat# DC LED Array Emergency Driver

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

SAVE THESE INSTRUCTIONS

Morris Products 53 Carey Road, Queensbury, NY 12804

IMPORTANT SAFEGUARDS

Installation and Operation Instructions 10/04/13

Installation Instructions Central Battery Units

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

B33 INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Spectron Industrial Series

Installation Instructions and User Manual For. 100 Watt Inverter Power System

Self-Testing Industrial Series

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

PSL600 MVOLT SD INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

MIRRORLITE RECESSED EMERGENCY LIGHTING

EMIU 720W Mini Inverter

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Installation Instruction

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

153M -48V POWER PLANT 5000 AMP

B30ST ! IMPORTANT SAFEGUARDS! SAVE THESE INSTRUCTIONS. Installation Instructions SELF-TESTING EMERGENCY LIGHTING EQUIPMENT

LED Utility Wrap Fixture

7.5 Oregon Fir With SYLVANIA Multi Color Mini Lights and Multi Color G50 Soft Glow Lights Pre-Lighted Tree V69139 INSTRUCTION MANUAL

Installation And Operation Instructions

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Model: SL360R Lithium Ion 360 LED Cordless Work Light

MANUFACTURED IN THE UK

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

MANUFACTURED IN THE UK

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

MAXLITE RKT LED Retrofit Kit

MaxLite LED UTILITY WRAP FIXTURES

Installation Instructions: Eco-Fit T8 LED Tube Lamp

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Universal Retrofit System Installation Instructions Revised:

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

AEROBAY INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

FHS2-UNV-36L INSTALLATION INSTRUCTIONS

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

A Home Depot Company. Quality Lighting for Every Facility

Installation And Operation Instructions

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions


PDX and PX Retrofit Series

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

LED Decorative Highbay

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

Assembly Instructions Retrofitting

Instruction/Installation Manual

PEC 827E. 120 VAC AC Distribution Shelf. Critical Power Product Manual

When using electrical equipment, basic safety precautions should always be followed including the following:

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

FHS2-UNV-56S SPECIFICATIONS

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

User Manual. SUN FLUX II Hot Water Controller. Model SEI 02. Off Grid/Hybrid PV Solar Hot Water Controller -1-

FHSCP-UNV-10P-L-SD SPECIFICATIONS

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

Transcription:

FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit. 2. - This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. Branch circuit and by disconnecting the unit connector. 3. The battery is sealed, non-maintenance, and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. 4.. The product is for use with grounded, UL Listed, indoor fixtures except in heated air outlets or hazardous locations. 5. The product requires an unswitched A.C. Power source of either 20 or 277 volts. Properly cap the unused A.C. Lead. 6. Do not mount near gas or electric heaters. 7. The product should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 8. This product is for use with 4 W through 54W(2'-4')T5 and T8 single pin or bipin for one lamp,instant Start and Rapid Start,4W through 39W(2'-4')T5 and T8 single pin or bipin for two lamp, Instant Start and Rapid Start,8 W through 50 W (4-pin) long compact Rapid Start, or 32 W (4-pin) compact, 24W through 32W U-Bend FBT8 fluorescent lamps from Philips,Osram and GE or equivalent manufacture. 9. The product is compatible with all A.C. magnetic and electronic ballasts including multiple lamp ballasts with one lamp operating in the emergency mode. 0. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.. Do not use this equipment for other than intended use. 2. Install in accordance with the National Electrical Code and local regulations. 3. Installation and servicing should be performed by qualified personnel. 4. Lighting fixture manufacturers, electricians and end users need to ensure product system compatibility before final installation. 5. The battery is sealed,non-maintenance,and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. 6. The rated operating time in the emergency mode with battery is -/2 hours and the recharge time shall not be less than 24 hours. SAVE THESE INSTRUCTIONS Warning-This product contains chemicals known to the State of California to cause cancer, birth defects and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product. UL R LISTED CONTAINS NICKEL-CADMIUM RECHARGEABLE BATTERY. MUST BE RECYCLED OR DISPOSED OF PROPERLY. Ni - Cd Hubbell lighting, Inc, 70 Millennium Blvd.Greenville SC 29607 864 678-000 FAX (864) 678-45 www.dual-lite.com 93039242-A Page

INSTALLATION INSTRUCTIONS NOTE: All the branch circuit wiring has to be ready as well as an unswitched source of power before the fixture is installed. Both AC and Emergency Ballasts must be Fed From the same branch circuit. CAUTION Battery connector has to be opened to prevent high voltage on output leads (Red and Yellow). Wait until all the installation process is completed and AC is supplying power to the emergency ballast before joining the battery connector.. AC power has to be off before installation. 2. Choose the right wiring diagram to connect the emergency ballast to AC ballast and lamp. 3. Please ensure the electrical connections conform to the National Electrical Code and local regulations if applicable. 4. Follow the diagram &2 to install the emergency ballast in the ballast channel. DIAGRAM DIAGRAM 2 Emergency Ballast Test Button,Indicator Light() Emergency Ballast Ballast Channel Cover Test Button,Indicator Light() 5. Wall switch has to be connected properly (Check diagram 3), Match the violet and brown leads to connect the to the emergency ballast(check diagram 4). The would be on after the fixture is installed properly. FIXTURE A. C. BALLAST DIAGRAM 3 SWITCHED FIXTURE A. C. BALLAST MON HOT A.C. / (277V) ORG (20V) BLK MON HOT A.C. / (277V) ORG (20V) BLK + VIOLET + VIOLET Select proper voltage lead. Cap unused lead. Select proper voltage lead. Cap unused lead. 6.Please search in readily visible location and stick the label with CAUTION: This Unit Has More Than One Power Supply Connection Point. To Reduce The Risk Of Electric Shock, Disconnect Both The Branch Circuit-Breakers Or Fuses And Emergency Power Supplies Before Servicing. 7. Do not join the inverter connector until the fixture is completely installed and AC power is supplied to the emergency ballast. 8. The battery needs to be charged for one hour in order to have short-term testing on the emergency function. Before having a long-term emergency function testing, the battery in emergency ballast has to be charged for 24 hours. NOTE: MARK AN APPROPRIATE LABEL ON INDICATOR LIGHT AND TEST SWITCH AFTE INSTALLATION. Page 2

OPERATION THE CHARGING INDICATOR LIGHT WOULD BE ON TO INDICATE THE BATTERY IS BEING CHARGED WHEN AC POWER IS APPLIED. THIS EMERGENCY BALLAST WOULD FUNCTION AND OPERATE ONE OR TWO LAMPS AT LEAST 90 MINUTES WHEN THE AC POWER IS FAILED. THE EMERGENCY BALLAST WILL OPERATE 4WATT TO 54WATT LAMPS AT LEAST 90 MINUTES. Strip Fixture FIXTURE FIXTURE BALLAST CHANNEL COVER PLASTIC TUBE 7/ 8 BUSHING FIXTURE LENS OBSERVE PROPER POLARITY NOTE: MARK AN APPROPRIATE LABEL ON INDICATOR LIGHT AND TEST SWITCH AFTER INSTALLATION. MAINTENANCE NOTE: SERVICES SHOULD ONLY PERFORMED BY QUALIFIED PERSONNEL. THE EMERGENCY BALLAST SHOULD BE CHECKED PERIODICALLY TO CONFIRM FUNCTIONING AND THE FOLLOWING SCHEDULE IS REMENDED. ) INSPECT THE CHARGING INDICATOR EVERY MONTH AND CONFIRM THAT IS ILLUMINATED. 2) PUSH THE TEST SWITCH FOR 30 SECONDS TO ENSURE THE EMERGENCY BALLAST IS FUNCTIONING. PERFORM THIS TEST EVERY 30 DAYS. 3) PERFORMING A LONG-TERM TEST (90 MINUTE BATTERY DISCHARGE) ONCE IN EVERY YEAR. ONE OR TWO LAMPS SHOULD BE OPERATED FOR NO LESS THAN 90 MINUTES. TABLE (FOR CONNETOR) LAMP DIAMETER T5,T8 LONG PACT PACT U-Bend FBT8 BASE TYPE SINGLE OR BIPIN 4 PIN(2G) 4-PIN 4 PIN POWER (LENGTH) 4W-39W 40W-54W 8W-39W 40W-50W 32W 24-32W NUMBER OF LAMPS EMER. CONNECTOR 2 2 2 CLOSE OPEN CLOSE CLOSE OPEN CLOSE CLOSE CLOSE OPEN Page 3

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT Typical schematics only may be used other ballast, consult the factory wiring diagram WIRING DIAGRAM For One Lamp Emergency Operation(4-54W) Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) / TO AC Refer to Table before connecting (-) / TO AC Refer to Table before connecting (-) / TO AC Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / / AC / BALLAST / YELL/BLK Refer to Table before connecting (-) TO AC / LAMP AC BALLAST Refer to Table before connecting / YELL/BLK / / (-) TO AC / LAMP LAMP 3 LAMP 4(EMERGENCY) NOTE: Use the proper input voltage lead, cap unused lead Page 4

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT Typical schematics only may be used other ballast, consult the factory wiring diagram WIRING DIAGRAM For Two Lamps Emergency Operation (4-54W) Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / Refer to Table before connecting (-) TO AC / / / AC BALLAST Refer to Table before connecting / / (-) TO AC / LAMP (EMERGENCY) AC BALLAST Refer to Table before connecting / / / / (-) TO AC / LAMP LAMP 4(EMERGENCY) Emergency only Operation Refer to Table before connecting (-) / TO AC Refer to Table before connecting (-) / TO AC Page 5