Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

Similar documents
OIL DISPENSING SYSTEM

USE AND MAINTENANCE MANUAL PA1 60 PA L LIGHTPUMP L DRUM TECH L HI-TECH L

M4 Troubleshooting 42

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

1 MECHANICAL FUEL METER

DIGITAL OIL PRESET METER OWNER S MANUAL

FR1118- P10. User s Manual

Ph: (07) Fax: (07) Pump Manual

POSITIVE DISPLACEMENT FLOWMETER

1200W INVERTER GENERATOR

:1 3:1 5:1 3:1 3:1 5:1 3:1 3:1 5:

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

12v / 24v Diesel Transfer Pump Kit

IN-LINE IN-LINE 12V pulses version

ASSEMBLY AND OPERATING INSTRUCTION MANUAL

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Wisdom Systems. SCR Urea/Adblue Transfer System. Operating Instructions. Outstanding Features. Chemical Transfer and Application Technology

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

fusion RF Control Handle

CFT24 &CFT230 PART NOS:

ENGINE DRIVEN 3 FULL TRASH PUMP

Engine oil. Introduction. Warning and indicator lights WARNING

Propane torch. Model Assembly And Operation Instructions

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

PNEUMATIC PUMP Series

OWNER S TECHNICAL MANUAL

Water pump Owner's Manual

AdBlue Electric Transfer Pump 12V & 24V DC

12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

DIGITAL RCD(ELCB) TESTER

1100W PORTABLE GENERATOR

PETROL POWER WASHER MODEL NO: PLS195, PLS265 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS0616

WILL INVALIDATE THE WARRANTY. PLEASE RETAIN THESE

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

HG 20F-012E-01 OIL CONTROL GUN

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

Level Measuring Sensor for Diesel Fuel Tanks

12V/24V DUAL VOLTAGE DIESEL FUEL TRANSFER PUMP

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

Users Manual. Phase Rotation Indicator

S9 SWEEPER PARTS MANUAL

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

HOSE END METER PRE-SET FOR OIL FÖRINSTÄLLBAR HANDMÄTARE FÖR OLJA

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Cordless Handheld. H90-LF Series. vax.co.uk

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

SINGLE ACTION FLUID PUMP

MANUAL ABOVE GROUND FUEL TANKS FOT HEATING MODELS MZPEB 1200 MZPEB 2500 MZPEB 3300

1/2 HP SUMP PUMP OWNER'S MANUAL

Electric Pressure Washer

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

60V RECHARGEABLE LITHIUM-ION BATTERY

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

INSTRUCTION MANUAL ANGLE GRINDER PT W

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

EASY CHARGE Waterproof portable Battery Charger

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

ORIGINAL INSTRUCTIONS

OPERATING INSTRUCTIONS MODE D EMPLOI GEBRAUCHSANLEITUNG INSTRUCCIONES PARA EL USO CENTER 200

Electronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015)

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

Model:G2WGD Double-Head Pasty Ointment Filling Machine. Operational Manual

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

OPERATING INSTRUCTION

M OTO R. The electric motor. DC - direct current voltage.

MANUAL FLUID EXTRACTOR

Multi-Mover Charger for model L25

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Electric Car User Manual

PROPANE TORCH WITH TURBO BURNER

ELECTRIC CAR POLISHER

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

M-3025CB-AV Fuel Pump

OPERATION MANUAL M185. MIG/flux wire feeder welder. Serial Number: Where Purchase: Date of purchased:

2-in-1 Air Operated Waste Oil Drainer

V3700UK OWNER S GUIDE.

SAFETY AND OPERATING MANUAL. Lithium-Ion cordless hammer drill WX372 WX372.1 WX372.9

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

MOTOR. The electric motor. DC - direct current voltage.

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

20V Lithium-Ion Battery Pack

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Gavita HortiStar 1000 DE EU/US

Head with piston Use and Maintenance Manual

Transcription:

Pump Manual Model Numbers: SP240VDFS57LPM SP240VDFS80LPM Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min Copyright: Scintex Fuel Depot 2012[Type text] Page 1

WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Model No.: SP240VDFS57LPM, SP240VDFS80LPM A. DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY IN ACCORDANCE WITH THE DIRECTIVES: 89/392/CEE - 91/368/CEE - 93/44/CEE 89/336/CEE 92/31/CEE THE MANUFACTURER: DECLARES THAT THE FOLLOWING PUMP MODELS: SP240VDFS57LPM, SP240VDFS80LPM To which this declaration refers, conform to the following applicable regulations: EUROPEAN REGULATIONS: EN292-1-92 Safety of Machinery General Concepts, basic principles for design terminology, basic methodology EN292-2-92 Safety of Machinery General Concepts, basic principles for design specifications and technical principles EN294-93 Safety of Machinery safe distances to prevent the operator s upper limbs from reaching dangerous areas EN60034-1-2000 Rotating electrical Machinery nominal and functional specifications EN60034-5-2001 Classification of grades of protection for the housings of rotating electrical machinery EN61000-6-3 Electro magnetic compatibility generic emission standards EN61000-6-1 Electro magnetic compatibility generic immunity standards EN55014-1-00(A1/99-A2/99) limits and methods for measuring radio disturbance characteristics EN55014-2-97 Electrical motor operated and thermal appliances for household and similar purposes, electric tools and similar electrical apparatus EN60204-1-98 safety of machinery electrical equipment of machines Copyright: Scintex Fuel Depot 2012[Type text] Page 2

B. INTRODUCTION The diesel transfer pump kit has been designed for the delivery of oil from an open surface tank. This manual, apart from giving all necessary information on ordinary maintenance and supporting engineers in failure detection and repair, should also give all the information s needed to fully employ the capacity of the machine, as well as to the user s needs. INSTALLATION Electric connection should be done on a CEI standard socket provided with switch (so it isn t live when the connection is done) according to L.46/90 prescriptions. PRELIMINARY INSPECTIONS Before the power connection is done, verify the conductors aren t live and general switches are off. DISMANTLING AND DISPOSAL PROCEDURE The metallic parts which the machine is mainly made of will be dismantled and sent to the steel mills. The fuels in the tanks of the installation will be collected and sent to an authorized disposer. All plastic and non-degradable material parts will be separately collected and sent to an authorized disposer or recycled. SAFETY DEVICES General Switch It is placed on the motor body and allows the operator to set it on standby in a very short time. Once the machine is stopped, the whole starting procedure can be repeated. Mechanical Protections They are metal protections meant to prevent access to mechanical moving parts, high-temperature parts and live electric parts. Harmful Functions The noise from the machine is below 70 db (A). HARMFUL EMISSIONS Steam emission is so reduced to result irrelevant. FIRE PREVENTION In case of fire never use water, but extinguishing powders charged with CO2 cat. A-B-C-D only, employing the extinguishers placed next to the machine. Combustion of paints and plastic parts may produce toxic emissions: use the normal precautions to be employed in case of fire (always refer to the security supervisor of the place of installation). NOTICE: THE VISION IS BUILT PAYING MAXIMUM CARE TO USER S AND MAINTENANCE ENGINEER S SECURITY. Copyright: Scintex Fuel Depot 2012[Type text] Page 3

C. TECHNICAL DATA ELECTRICAL POWER POWER PUMP MODEL Flow Rate Nominal Current Voltage(V) Frequency (Watt) SP240VDFS80LPM 80LPM/22GPM AC 230 50/60 450 SP240VDFS57LPM 56LPM/15GPM AC 230 50/60 370 D. PRECAUTIONS During Diesel delivery always wear oil resistant and always wash hands with water and soap at the end. Always clean at once oil stains to avoid slips and/or pollution. Use particular care with the zones next to the controls. When cleaning, and specially when removing dust or waste, always wear suitable clothes, if possible use aspirators only. Always use suitable clothes or protective devices. Never place hands or limbs under moving parts. E. SYSTEM DESCRIPTION Functional Description The diesel transfer system are hydraulic machine tools which feed with a given capacity (volume) of fluid in the time unit, a collecting tank, sucking the liquid from an open surface feed tank; the allowed suction lift (geodetic suction lift Hga) is also a specific characteristic of the pump. The system is composed by complementary equipment, operating as whole to give a complete service: Feeding pump Digital meter Suction kit (Fuel hose with filter) Delivery hose Dispensing nozzle Copyright: Scintex Fuel Depot 2012[Type text] Page 4

F. ALLOWED AND FORBIDDEN USE Diesel transfer unit has been designed and built for DIESEL TRANSFER ONLY from reservoirs, tanks and drums. It is strictly forbidden to employ it to transfer liquids of different kind as gasoline, explosives and corrosives (or flammable), alimentary liquids. The machine isn t designed for employment in the explosive environment. Operating the pump is forbidden to children and disabled person. It is forbidden to employ the unit next to flammable liquids (gasoline, alcohol, etc.). It is forbidden the employment in closed environments in presence of gasoline, LPG, methane fuelled vehicles. G. TRANSPORT AND UNPACKING Due to its weight and dimensions, the unit can easily be transported by hand. Control that the package is good conditions and verify that the unit isn t damaged. Each failure must be noticed in 10 days from receiving the machine. For correct unpacking carefully follow these instructions: 1. Place the case on the ground following the indications on the package. 2. Carefully open the case, remove the machine and place it on the ground or on a steady surface. 3. Control that the machine and its accessories aren t damaged. 4. Fasten the panel, placing it on the ground or on a steady surface capable of carrying the pump, in a repaired environment with a temperature between +40 and -20 well lit and ventilated. For a better employment the unit should be placed as near as possible to level of liquid to be pumped. (Max. distance 2m) 5. Screw the delivery hose on the fitting of the flow meter and of the filling gun. 6. We suggest using a diesel resistant rubber or plastic suction hose; spiral shaped, with minimum as 25mm internal diameter, the same as the union. The hose must be sealed to avoid leaks. In case a 4 meters or longer hose is employed we suggest to use the foot valve with filter. H. USE AND STARTING POWER GRID ELECTRICAL CONNECTION The plant must be provided with a safety device of 30mA minimum Din standard. The plug must be connected to an earthed SHUKO socket. It is forbidden to cut or replace the provided plug. STARTING Once the hoses are sealed, the feeding cable is connected and the filling gun is in rest position, the machine can be started. After placing the hose into the tank and the gun into the filling hole, start the pump, gradually move the switch to ON and start fuel transfer pump kit. Once the filling is done, release the control of the nozzle and switch the pump off. Then put the nozzle back to the holder. FLOW METER Copyright: Scintex Fuel Depot 2012[Type text] Page 5

1. Technical Details Description Europe America Flow rate Operating temperature 10~100L/m 3~26gpm -10 ~ +50 14 ~ 122 Accuracy ±0.5% Fluid type Diesel & kerosene 5-Digit present total(0.01~999.99) 5-Digit present total(0.01~999.99) Screen 6-Digit resettable total(1~999999) 6-Digit general total (cannot be reset, 1~999999) Unit (Liter) 6-Digit resettable total(1~999999) 6-Digit general total (cannot be reset, 1~999999) Unit (Gallon, Pint, Quart) 2. Operation A. Function Button introduction 1 LCD display 2 MENU button 3 RESET button LCD display 1 Present total (5-digit with floating point from 0.01 to 999.99) 2 General total 3 Two types of total Resettable total (6-digit with floating point from 1 to 999999) General total (cannot be reset, when it indicated together with TOTAL, 6-digit with floating point from 1 to 999999) 4 Measurement unit (L, GAL, PT, QT) Copyright: Scintex Fuel Depot 2012[Type text] Page 6

B. Operation a. Before putting into operation Check the technical data of the installation match with those of the meter. For example, connection, pressure, flow rate range, medium, etc. Make sure the correction factor is right, or set the proper correction factor (refer to b for correct factor). Check all connections to avoid leakage. b. Button usage, calibration and measurement unit change Reset the present total 1) When the meter is on standby, press the RESET key less than 5 seconds. 2) The display shows all the segments. 3) The meter resets the present total already. Reset the resettable total 1) When the meter is on standby, press the RESET key more than 5 seconds, keep it pressed until the resettable total changes to 0. 2) The meter resets the resettable total already, and also reset the present total. Show current correction factor and general total Wait for the meter to go to standby, press the MENU and RESET keys together. Keep these pressed, LCD shows the current correction factor in 1 zone and general total in 3 zone. The icon of TOTAL is lighted. Calibration and changing measurement unit 1) Directly input the correction factor If the meter shows a mean percentage error, this can be corrected by input proper correction factor, it must be calculated by the following formula. proper correction factor = current correction factor (actual value/ display value) Example: Actual value 20.75 Display value 18.96 Copyright: Scintex Fuel Depot 2012[Type text] Page 7

Current correction factor 1.000 Proper correction factor 1.000 (20.75/18.96)=1.000 1.094=1.094 Procedure for input the correction factor 1 Wait for the meter to go to standby. 2 Reset the resettable total. 3 Press the MENU key, keep it pressed until indicated as the figure, the digit flash in 1 zone, it means the meter is in correction factor modification mode. 4 Press the RESET key to choose the right digit from 0 to 9. Press the MENU key to start the next digit. So the digit of correction factor can be changed one by one. 5 Make sure the correction factor is right, press the MENU key, keep it pressed until quit calibration mode, the factor is saved. The meter goes to standby again. 2) Modify the correction factor in field. Please carefully follow the procedure indicated below. In-field calibration procedure 1 Wait for the meter to go to standby. 2 Reset the resettable total. Copyright: Scintex Fuel Depot 2012[Type text] Page 8

3 Start dispensing into a measuring glass. Stop dispensing when the total capacity reached 5Liter. Get the actual value from the measure glass. The value indicated in the LCD screen is the display value. For example, display value is 18.96, actual value is 20.75 4 Press the MENU key, keep it pressed until indicated as the figure (the digit flash in 1 zone), Press the RESET key to choose the right digit from 0 to 9. Press the MENU key to start the next digit. So the actual value can be input. 5 Make sure the correction factor is right, press the MENU key, keep it pressed until quit calibration mode, the factor is saved. The meter goes to standby again. 3) Changing measurement unit 1 Wait for the meter to go to standby. 2 Reset the resettable total. Copyright: Scintex Fuel Depot 2012[Type text] Page 9

3 Press the MENU key, keep it pressed until indicated as the figure (the digit flash in 1 zone). Press the MENU key, until the digit flash in 4 zone. Press the RESET key to select the desired measurement unit, it can switch among four types of units, L, GAL, PT and QT. 4 Press the MENU key, keep it pressed until quit this mode, and the new measurement unit is saved. The meter goes to standby again, and it will be ready to work in the new measurement unit.(see figure) WARNINGS 1. The gunlock has been provided to make filling easier. It is forbidden to leave the gun unattended to avoid overflow. 2. Don t operate the machine if there is no liquid inside. Don t start the pump before connecting suction and delivery hoses. 3. Once the gun is closed switch the motor pump off as soon as possible. THE PUMP HAS TO WORK IN BY-PASS CONDITION FOR SHORT PERIOD: MAXIMUM 3 MINUTES. 4. In case of current losses the pump should be switched off and the plug disconnected. 5. It is strictly forbidden to use the pump with wet hands, barefooted or dipped in water. 6. In case of blackout switch the pump off and disconnect the plug to avoid unexpected starts with liquid overflow. 7. When transferring from open-air tanks, we suggest to place the machine as far as possible to avoid sprays and sudden dips which may cause serious damage. I. MAINTENANCE Each kind of disassembly should always be carried out when the machine is stopped, the plug is disconnected and after emptying the pump and the flow meter. For a better operation control every three months that there isn t any kind of debris in the flow meter filter. Copyright: Scintex Fuel Depot 2012[Type text] Page 10

J. OPERATIONAL PROBLEMS ACCIDENTS CAUSES REMEDIES The pump doesn t work A) Jammed shaft A) Disconnected the plug; B) No electric feeding unscrew on the pump, remove the pump body and clean it inside. Control that the shaft is now working correctly. Reassemble the pump. B) Control that the plug is correctly connected and that the socket is live. The pump works doesn t deliver liquid. A) The pump sucks air from the suction hose. B) Air inside the pump A) Control the suction hose seal on the pump. Verify that the hose is completely immersed into the liquid and free from chokes. B) Control that the filter is clean. C) Ensure the suction height is less than 4M. K. MECHANICAL RISKS 1. Mechanical parts subject to wear The blades The bearing The rotor These parts should be replaced with original spare parts by qualified personal only or in authorized service centres. 2. Risks due to extreme temperatures Remember that a very low temperature can freeze the Diesel inside the pump. This situation can cause serious damage to the motor pump unit. 3. A very high temperature (about 45 ) may cause the plastic parts in the unit to expand. The unit should thus be placed in a well-ventilated place and protected from the sun. Copyright: Scintex Fuel Depot 2012[Type text] Page 11

L. DIAGRAM & PARTS LIST Part No. Component description Quantity Part No. Component description Quantity 1 Automatic Nozzle 1 12 AC Fuel Transfer pump 1 2 Nozzle holder 1 13 Washer 4 3 Hose Holder 1 14 Bottom plate 1 4 Fitting 1 15 Bolt M4 8 5 Outlet 1 16 Power cord 1 6 Elbow 1 17 Fitting 1 7 Measuring gauge 1 18 Inlet 1 8 LCD Display 1 19 One-way valve 1 9 Cover Board 1 20 Filter Mesh 1 10 Bolt M6 4 11 Bolt M8 2 Copyright: Scintex Fuel Depot 2012[Type text] Page 12

NOTE: The parts following parts list showed are optional Part No. Component description Quantity 1 Manual Nozzle 1 17 Fitting 1 19 One-way valve 1 www.scintex.com.au www.thefueldepot.com.au Copyright: Scintex Fuel Depot 2012[Type text] Page 13