MG L 750kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Similar documents
SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

DATA CENTER SOLUTIONS

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES AND TANKS EPA TIER COMPLIANT

MD300. Industrial Diesel Generator Set. 300 kw Diesel. primary codes and standards. Standby Power Rating 375kVA 300kW 60Hz

MD400. Industrial Diesel Generator Set. 400 kw Diesel. primary codes and standards. Standby Power Rating 500kVA 400kW 60Hz PARALLELING UNIT

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

D I E S E L G E N E R A T O R S E T S

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

60 Hz FEATURES. Exclusively from your Caterpillar dealer

GENERAC GUARDIAN SERIES STANDBY GENERATORS

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

DG175 GC to DG450 GC GAS GENERATOR SETS

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

RENTAL DIESEL GENERATOR SET

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSX15 series engine

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

DIESEL GENERATOR SET. 60 Hz FEATURES

DIESEL GENERATOR SETS

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Diesel generator set QSK23 series engine

DIESEL GENERATOR SET FEATURES

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Transcription:

TM Standby Power Rating 750 k, 938 kva, 60 z Demand Response Power Rating 750 k, 938 kva, 60 z Prime Power Rating* 675 k, 844 kva, 60 z *Assembled in the USA using domestic and foreign parts *EPA Certified Prime ratings are not available in the US or its Territories Image used for illustration purposes only CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details. U2200, U508, U489 CSA C22.2, B149 BS5514 and DIN 6271 SAE J1349 NFPA 37, 70, 99, 110 NEC 700, 701, 702, 708 ISO 3046, 8528, 9001 NEMA ICS1, ICS10, MG1, 250, ICS6, AB1 POERING AEAD Generac ensures superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. But Generac also makes its own spark-ignited engines, and you ll find them on every Generac gaseous-fueled generator. e engineer and manufacture them from the block up - all at our facilities throughout isconsin. Because applying natural gas and P-fueled engines to generators requires advanced engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility. Plus, Generac Industrial Power s distribution network provides all parts and service so you don t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas. ANSI/IEEE C62.41 1 OF 6

STANDARD FEATURES ENGINE SYSTEM Electrical System ENCOSURE (If Selected) Oil Drain Extension eavy Duty Air Cleaner Fan Guard Stainless Steel Flexible Exhaust Connection Factory Filled Oil & Coolant Critical Exhaust Silencer/Catalyst Radiator Stone Guard (Open Set Only) Fuel System NPT Fuel Connection on Frame Primary and Secondary Fuel Shutoff Cooling System Closed Coolant Recovery System Factory-Installed Radiator 50/50 Ethylene Glycol Antifreeze Radiator Drain Extension Can Operate at up to 122 F (50 C) Ambient Temperature Battery Charging Alternator Battery Cables Battery Tray Rubber-Booted Engine Electrical Connections Solenoid Activated Starter Motor ATERNATOR SYSTEM U2200 GENprotect Fault Protector Class Insulation Material 2/3 Pitch Skewed Stator Permanent Magnet Excitation Sealed Bearings Amortisseur inding ow Temperature Rise <120 C Motorized Main ine Circuit Breaker GENERATOR SET Spring Genset Vibration Isolators Separation of Circuits - igh/ow Voltage Separation of Circuits - Multiple Breakers rapped Exhaust Piping Standard Factory Testing 2 Year imited arranty (Standby Rated Units) Ready to Accept Full oad in <10 Seconds igh Performance Sound-Absorbing Material (Sound Attenuation Enclosures) eavy Duty Gasketed Doors Made from Non- ygroscopic Rubber Structural Steel Sub-Base Sub-Base ifting Eyes Enamel Finish Zinc Plated Fasteners Zinc Plated Cast Aluminum Keylock Door andles eavy Duty Stainless Steel inges with Removable Brass Pins Bolt Together Modular Construction eavy Duty Single Point atches RhinoCoat - Textured Polyester Powder Coat Paint CONTRO SYSTEM Power Zone NFPA 110 evel 1 Complaint Engine Protective Functions Alternator Protective Functions Digital Engine Governor Control Digital Voltage Regulator Multiple Programmable Inputs and Outputs Remote Display Capability Remote Communication Via Modbus RTU, Modbus TCP/IP, Ethernet 10/100 Alarm and Event ogging with Real Time Stamping Expandable Analog and Digital Inputs and Outputs Remote ireless Software Update Capable i-fi, Bluetooth, BMS and Remote Telemetry Single Point Ground Built-In Programmable ogic Eliminates The Need For External Controllers Under Most Conditions Ethernet Based Communications Between Generators Programmable I/O Channel Properties Built-In Diagnostics Protections ow Oil Pressure ow Coolant evel igh/ow Coolant Temperature Sensor Failure Oil Temperature Over/Under Speed Over/Under Voltage Over/Under Frequency Over/Under Current Over oad igh/ow Battery Voltage Battery Charger Current Phase To Phase and Phase To Neutral Short Circuits (I 2 T Algorithm) 7 Color Touch Screen Display Capacitive Color Touch Screen Sunlight Readable (1400 NITS) Easily Identifiable Icons Multi-ingual On Screen Editable Parameters Key Function Monitoring Three Phase Voltage, Amperage, k, kva, and kvar Selectable ine to ine or ine to Neutral Measurements Frequency Engine Speed Engine Coolant Temperature Engine Oil Pressure Engine Oil Temperature Battery Voltage ourmeter arning and Alarm Indication Diagnostics Maintenance Events/Information Parallel Control Features Paralleling Control (Synchronizing) Reverse Power oss Of Synchronization Between Gensets oad and VAR Sharing 2 OF 6

CONFIGURABE OPTIONS ENGINE SYSTEM Engine Block eater Cold eather Kits Oil eater Two Stage Air Cleaner Air Filter Restriction Indicator Radiator Stone Guard (Enclosed Units Only) EECTRICA SYSTEM 20A U Battery Charger Battery armer FUE SYSTEM NPT Flexible Fuel ine ATERNATOR SYSTEM Alternator Upsizing Anti-Condensation eater GENERATOR SET Extended Factory Testing 24 Position oad Center CONTRO SYSTEM NFPA 110 evel 1 Compliant 21-ight Remote Annunciator Remote Output Relays (8 or 16) Oil Temperature Indication and Alarm Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) 10A Engine Run Relay Ground Fault Annunciator Damper Alarm Contacts 100dB Alarm orn 120V GFCI and 240V Outlets Permissive/oad Shed Module ENCOSURE eather Protected Enclosure evel 1 Sound Attenuation evel 2 Sound Attenuation evel 1 Sound Attenuation with Motorized Dampers evel 2 Sound Attenuation with Motorized Dampers Steel Enclosure Aluminum Enclosure 120V AC Enclosure ighting Kit Enclosure Ambient eaters Up to 200 MP ind oad Rating* (Consult Factory for Availability) ARRANTY (Standby Gensets Only) 2 Year Extended imited arranty 5 Year imited arranty 5 Year Extended imited arranty 7 Year Extended imited arranty 10 Year Extended imited arranty ENGINEERED OPTIONS CONTRO SYSTEM Additional Spare Inputs/Outputs Battery Disconnect Switch ATERNATOR SYSTEM 3rd Main ine Circuit Breaker 4th Main ine Circuit Breaker Unit Mounted oad Banks Medium Voltage Alternators GENERATOR SET Special Testing Battery Box 3 OF 6

APPICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make Generac Cylinder # 12 Type 4-Cycle Displacement - in 3 () 2,071 (33.9) Bore - in (mm) 5.91 (150) Stroke - in (mm) 6.30 (160) Compression Ratio 10.0:1 Intake Air Method Turbocharged/Aftercooled Number of Main Bearings 7 Cylinder ead Cast Iron - 4 Valve Ignition Electronic Piston Type Aluminum Crankshaft Type Drop Forged Steel ifter Type Solid Intake Valve Material SU3 w/tuftride & Stellite Exhaust Valve Material SU3 w/tuftride & Stellite ardened Valve Seats Proprietary Alloy Crankcase Ventilation Closed Engine Governing Cooling System Cooling System Type Unit Mounted Radiator Fan Type Pusher Fan Speed (rpm) 1080 Fan Diameter - mm (in) 64 (1,625) Fuel System Fuel Type Natural Gas Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard (Dual) Operating Fuel Pressure in 2O (kpa) 11-14 (2.7-3.5) Engine Electrical System System Voltage 24 VDC Battery Charger Alternator Standard Battery Size See Battery Index 0161970SBY Battery Voltage (4) - 12 VDC Ground Polarity Negative Governor Electronic Frequency Regulation (Steady State) ±0.25% ubrication System Oil Pump Type Gear Oil Filter Type Cartridge Crankcase Capacity with Filters - (qts) 160 (151) ATERNATOR SPECIFICATIONS Standard Model K0912124Y22 Poles 4 Field Type Rotating Insulation Class - Rotor Insulation Class - Stator Total armonic Distortion <4% Telephone Interference Factor (TIF) <50 Standard Excitation Permanent Magnet Bearings Single Sealed Coupling Direct via Flexible Disc Prototype Short Circuit Test Yes Voltage Regulator Type Full Digital Regulation Accuracy (Steady State) ±0.25% 4 OF 6

OPERATING DATA POER RATINGS Three-Phase 120/208 VAC @0.8pf 750 k Amps: 2,602 Three-Phase 120/240 VAC @0.8pf 750 k Amps: 2,255 Three-Phase 277/480 VAC @0.8pf 750 k Amps: 1,128 Three-Phase 346/600 VAC @0.8pf 750 k Amps: 902 MOTOR STARTING CAPABIITIES (skva) skva vs. Voltage Dip 277/480 VAC 30% 208/480 VAC 30% K0912124Y22 3,250 K1000124Y22 Contact Factory K1000124Y22 3,900 K1220124Y22 Contact Factory K1220124Y22 3,250 K1440124Y22 2,450 FUE CONSUMPTION RATES*- Natural Gas scfh (m 3 /hr) [at standard conditions 68 C, 14.7 psi] Percent oad Standby 25% 2,718 (77) 50% 4,110 (116) 75% 5,820 (165) 100% 7,770 (220) * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOING Air Flow (Fan Air Flow Across Radiator) scfm (m 3 /min) 32,515 (920.7) Coolant Flow gpm (pm) 291 (1,101) Coolant System Capacity gal () 55 (208) Max. Operating Ambient Temperature F ( C) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Radiator Backpressure in 2 O (kpa) 0.50 (0.12) COMBUSTION AIR REQUIREMENTS Flow at Rated Power scfm (m 3 /min) 1,449.7 (41.1) ENGINE EXAUST Rated Engine Speed rpm 1,800 Exhaust Flow (Rated Output) scfm (m 3 /min) 5,449 (154.3) orsepower at Rated k** hp 1,118 Max. Backpressure (Post Turbocharger) in 2 O (kpa) 27 (6.7) Piston Speed ft/min (m/min) 1,890 (576) Exhaust Temp (Rated Output - Post Silencer) F ( C) 1,332 (722) BMEP psi (kpa) 226 (1,561) 5 OF 6 ** Refer to Emissions Data Sheet for maximum bp for EPA and SCAQMD permitting purposes Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.

MG750 33.9 750k EPA Cer tified Stationary Emergency and Non Emergency DIMENSIONS AND EIGTS* OPEN SET (Includes Exhaust Flex) x x - in (mm) 182.5 (4,637) x 84.3 (2,141) x 142.0 (3,606) eight - lbs (kg) 16,371 (7,426) EATER PROTECTED ENCOSURE x x - in (mm) eight - lbs (kg) 202.0 (5,130) x 98.0 (2,489) x 156.5 (3,975) Steel: Contact Factory Aluminum: Contact Factory EVE 1 ACOUSTIC ENCOSURE x x - in (mm) eight - lbs (kg) 288.0 (7,315) x 100.0 (2,540) x 156.5 (3,975) Steel: Contact Factory Aluminum: Contact Factory EVE 2 ACOUSTIC ENCOSURE x x - in (mm) eight - lbs (kg) 339.9 (8,634) x 151.7 (3,852) x 156.5 (3,975) Steel: Contact Factory Aluminum: Contact Factory * All measurements are approximate and for estimation purposes only. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIA DEAER Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. P.O. Box 8 aukesha, I 53189 P: (262) 544-4811 2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. 6 OF 6 Part No 10000024341 Rev. 1 07/10/18