Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions 1662SG SG.223

INSTALLATION INSTRUCTIONS STUDIO S

Installation Instructions

Installation Instructions 1662SG SG.222

Installation Instructions 1662SG SG.224

Installation Instructions

INSTALLATION INSTRUCTIONS

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions Series Series

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions

Installation Instructions

SERIN MONOBLOCK LAVATORY FAUCET with

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions 7024

Installation Instructions

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions Series

Installation Instructions

Installation Instructions

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

G2 Optima Plus Flushometer

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

INSTALLATION INSTRUCTIONS

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Installation Instructions

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

INSTALLATION INSTRUCTIONS

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

AquaSense ZTR Series

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Sloan & Zurn Flush Valves

Single Lever Pull-Down Kitchen Faucet

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

AquaSense AV ZER Series

Installation Instructions

INSTALLATION INSTRUCTIONS

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

Ventus Single Handle Vessel Bathroom Faucet

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS

AquaSense AV ZER Series

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Ramus Single Handle Lavatory Faucet

AquaSense TM ZTS6200EV Series

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

Installation Instructions / Warranty

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions

Transcription:

Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning piston valve prevents clogging and reduces maintenance. OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: 0gpm (7.9 L/min). Flush valves include sweat solder kit. **Water pressure over 80 psi is not recommended with most plumbing fixtures NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, please call -800--90 (In Canada: -800-87-09) (In Toronto Area only: -90-009)

Thank you for selecting American-Standard...the benchmark of fine quality for over 00 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. UNPACKING All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.. Flush Valve Assembly. Down Tube and Vacuum Breaker. Spud Coupling Nut and Washers. Spud Flange. Sweat Solder Adapter. Cover Tube 7. Wall Escutcheon 8. Supply Stop 9. Installation Instructions CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. 7 8 9 Installation Instructions for /" top spud Urinals Certified to comply with: ASSE 07 ANSI/ASME A.9. ADA Compliant 0 AS America, Inc. MODEL NUMBERS 0.0 FOR TOP SPUD APPLICATIONS CLOG RESISTANT Self-cleaning piston valve prevents clogging and reduces maintenance. OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: psi (flowing) - 80 psi (static) FLOW REQUIREMENT: 0gpm (7.9 L/min). Flush valves include sweat solder kit. **Water pressure over 80 psi is not recommended with most plumbing fixtures NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, please call -800--90 (In Canada: -800-87-09) (In Toronto Area only: -90-009)

Fig. Roughing-in Dimensions 08mm-mm (-/" to -/") FINISHED WALL 8mm-7mm (-/-") GENERAL DESCRIPTION: for /" Top Spud Fixtures Exclusive, self cleaning piston-operated flush valve. SUPPLY DN 9mm (/" I.P.S. For /" Top Spud) *CRITICAL LEVEL /" VACUUKM BREAKER SHOWN mm () (Min.) 9mm (-/") mm (-/") -C-L- -C-L- OPERATING PRESSURE: Overall Range: 0- psi ** Recommended: 0 psi (flowing)- 80 psi (static) FLOW REQUIREMENT: 0gpm (7.9 L/min). **Water pressure over 80 psi is not recommended with most plumbing fixtures *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be " (mm) minumim above fixture. Consult Codes for details. Right or Left Hand Installation See (Section 8) for converting Flush Valve to Left Hand Installation. RECOMMENDED TOOLS; Fig. Fig....... 7. 8. 9. 0. Teflon Tape Flat Blade Screwdriver (For adjusting Supply Stop) Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch.mm Hex Wrench.mm Hex Wrench 0' 7 9 0 8 PRIOR TO INSTALLATION Note: Prior to installing the Selectronic Flush Valve the following items must be installed.. Urinal. Drain line. Water supply line IMPORTANT: All plumbing must be installed in accordance with applicable codes and regulations. Water supply lines must be sized to provide an adequate volume of water for each fixture. Flush all water lines prior to operation (See Step ). Dirt and debris can cause flush valve to run continuously. With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling! Protect the chrome or special finish on the Flushometer. DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see Care and Cleaning section of this manual. This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve s performance.

INSTALL SWEAT SOLDER ADAPTER; Fig. CAUTION Turn water supplies off before beginning Note: Install Optional Sweat Solder Adapter (Supplied) for copper pipe supply line. Fig.. Fig. FINISHED WALL A Fig.a CENTER LINE OF FIXTURE SPUD. Measure the distance (A) from the finished wall to the center of the inlet spud on the fixture.. Cut the supply pipe -/" (A-B=C) shorter then the measurement taken in Step. File any rough edges off the end of the supply pipe. (A-B)= C FILE EDGES CLEAN B mm (-/). Clean the end of the supply pipe. Push the threaded Adapter on until it is seated against the internal stop. Sweat the Adapter to the pipe. ADAPTER SOLDER ADAPTER INSTALL COVER TUBE, WALL ESCUTCHEON and SUPPLY STOP; Fig.. Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension X ). Cut COVER TUBE () to length (X). Apply Teflon Tape to the threaded end of the Adapter or supply pipe. Fig. a.. Push the COVER TUBE () into the WALL ESCUTCHEON (). Slide both onto the SUPPLY PIPE (). Fig. b.. Push the COVER TUBE () in to expose the threads of the supply pipe. Fig. c. With a wrench thread the SUPPLY STOP () onto the SUPPLY PIPE (). Align and tighten. Fig. c.. Pull COVER TUBE () against SUPPLY STOP () and push WALL ESCUTCHEON () against finished wall. INSTALL DOWN TUBE AND VACUUM BREAKER; Fig. Fig. Fig. a Fig. b Fig. c Fig. X FINISHED WALL TEFLON TAPE X. Place the SPUD FLANGE () over the spud on the Fixture.. Thread SPUD COUPLING NUT () onto Spud. Make sure SEAL WASHER () and FRICTION WASHER () are installed. Do not tighten fully.. Insert the DOWN TUBE () into the SPUD COUPLING NUT () and push it down. Note: If cutting Down Tube () to size, note that Critical Line (C/L) on Vacuum Breaker must typically be " (mm) minumim above fixture. Consult Code for details. /" TOP SPUD

INSTALL FLUSH VALVE; Fig. a & b. As shown in Fig. a, insert the side INLET FLANGE () on the FLUSH VALVE () into the SUPPLY STOP (). Lubricate the INLET FLANGE O-RING () with water if necessary. Lightly tighten COUPLING NUT (). Fig. a. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape. Fig. a. Align the FLUSH VALVE () (Fig. b) directly above the DOWN TUBE (7) and VACUUM BREAKER COUPLING NUT (). Make sure that GASKET (0) is installed. Note: There is a + mm, ( + /) tolerance for the mm (-/) dimension. Fig. b.. Pull the DOWN TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the VACUUM BREAKER COUPLING NUT (). Align all components of the flush valve assembly. Fig. b.. Lightly tighten the COUPLING NUT () connection first, then the VACUUM BREAKER COUPLING NUT () and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten couplings to make water tight connections. Fig. b. Fig. b mm, + mm (-/)( + /) 8 0 7 9 FLUSH OUT SUPPLY LINES; Fig. 7. Remove COVER () from SUPPLY STOP (). Make sure supply stop is closed. Fig. 7. Remove FLUSH VALVE CAP (). Pull out PISTON (). Replace FLUSH VALVE CAP () and tighten.. With a flat blade screwdriver open SUPPLY STOP (). to flush line of any debris or sediment.. Close SUPPLY STOP (). Remove FLUSH VALVE CAP (). Replace PISTON (). Replace FLUSH VALVE CAP () and tighten. COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER CLOCKWISE CLOSES CONTROL STOP

ADJUST SUPPLY STOP; Fig. 8 IMPORTANT: To avoid overflowing, the SUPPLY STOP () must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture and drain must be able to handle a continuous flow in case of a flush valve failure. Valve is designed to provide stated flush volume with a 0 GPM flow rate.. Remove COVER () from SUPPLY STOP ().Turn on water supply / turn to / turn(ccw) and test for leaks. Note: Unit may flush for approximately to 0 sec. when water is first turned on.. Actuate the FLUSH VALVE by pulling handle down.. Adjust SUPPLY STOP () after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed.. When adjustment is complete, replace COVER () and tighten to ensure vandal-resistance. Fig. 8 CLOCKWISE CLOSES CONTROL STOP REMOVE COVER COUNTER-CLOCKWISE OPENS CONTROL STOP 7 HOW TO RETROFIT OUR VALVE; Fig. 9 (Replaces Industry Standard Manual and Electronic Valves) Note: In most Retrofits the wall escutcheon, supply stop, cover tube and vacuum breaker do not have to be replaced. If these items do need replacement they must be purchased separately or order the complete flush valve assembly from American Standard.. Remove COVER () from SUPPLY STOP () if installed. Fig. 9. Fig. 9 Fig. 9a Fig. 9b CLEAN CONNECTIONS. Turn water supply off. Fig. 9.. Loosen SPUD COUPLING NUT (). Unthread COUPLING NUT () and VACUUM BREAKER COUPLING NUT (). Remove FLUSH VALVE (). Fig. 9a.. Clean all threaded connections before installing the new flush valve. Fig. 9a.. Refer to Sections, and to complete the retrofit installation. Fig. 9b. LEFT OR RIGHT HAND INSTALLATION; Fig. 0 8 Fig. 0 Right or Left Hand Installation. The FLUSH VALVE can be installed either as a right or left hand installation.. Orientate the FLUSH VALVE as shown in Fig. 0 to desired position for a left or right hand installation. Left Hand Right Hand

for Top Spud Urinals MODEL NUMBERS 0.0 M99-0070A CAP SEAL M998-0070A CUP SEAL M999D-007000A PISTON ASSEMBLY M998-000A HANDLE ASSEMBLY OPTIONAL ADJUSTABLE TAILPIECE (Purchased Separately) M98-000A (8-/" to 9-/" Rough-in) M98-000A (7-/" to 8-/" Rough-in) M98-000A (-/" to 7-/" Rough-in) M98-000A (-/" to -/" Rough-in) M990-000A ADJUSTABLE TAILPIECE (-/" to -/" Rough-in) M99-0070A VACUUM BREAKER REPAIR KIT M9-000A /" VACUUM BREAKER ASSEMBLY M9-000A /" INLET PIPE ASSEMBLY M907-000A STAMPED FLANGE M907-000A COVER TUBE M907-0070A SWEAT ADAPTER M90-000A /" SUPPLY STOP M909-000A CAP M9-000A /" SPUD ASSEMBLY HOT LINE FOR HELP For toll-free information and answers to your questions, call: (800) -90 Weekdays 8:00 a.m. to :00 p.m. EST IN MEXICO 0-800-89-00 IN CANADA -800-87-09 (TORONTO -90-0-09) Weekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 0