Lighthouse Power Pedestals,

Similar documents
Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Harbor Light Model HL General Specifications

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

Marina Power and Lighting Product Focus. Power Pedestals Distribution Equipment

Marina Power and Lighting Equipment. Product Focus. Power Pedestals Distribution Equipment. High-Quality, Weatherproof Electrical Equipment

Beginner's Guide to Marinas, RV Parks, and NEC Requirements for Both

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

Installation Instructions for Admiral Power Pedestal (# )

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Marina Mate SS Model MMSS2050 Installation, Maintenance, and Operation Manual

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

6.1 Introduction Product Description... Application Description... Optional Features...

Harbor Light SS Model HLSS Installation, Maintenance, and Operation Manual

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Marina Mate SS Model MMSS2050. Installation, Maintenance, and Operation Manual

Anchorage SS Center Model AN3050. Installation, Maintenance, and Operation Manual

Volume 1 Residential and Light Commercial CA E December

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Installation Instructions for the Powerslide RV Pedestal #

Marina Power & Lighting Capabilities Brochure

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

Installation, Maintenance, and Operation Manual

Dry-Type Transformers Mini-Power Centers

Every accessory for today s dock......except the boat. Version 08

Recreational Vehicle Park Electrical Products & Accessories

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

CT Metering. CT Metering. Meter Mounting Equipment

5.2. Power Pedestals. Contents Description

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Electrical Wiring Practices

Fire Station Hose Rack Model FSHR Installation, Maintenance, and Operation Manual

Equipment. Metering. Metering Equipment 1. Contents

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Equipment. Metering. Metering Equipment 1. Contents

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

6.2. Power Pedestals. Contents

AMENDMENT ELECTRIC SERVICE MANUAL 2014

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

SEA PORT MARINE CORP.

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

WF-5110R True Sine Wave Inverter

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Design Standard. Purpose: Design Standard:

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

BUSWAY Low Voltage (Pow-R-Flex)

Solar Combiner Solutions

WF-5110R True Sine Wave Inverter

320A Single Phase URD Meter Loop Installations

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Weather Protective Devices

Installing Power Components

Design Standards NEMA

Lighting and Power Distribution Panelboards

Group Meter Main - Without Bypass

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

East Central College

Solar Combiner Solutions

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

Contents. Volume 1 Residential and Light Commercial CA E December

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

Individual & fixed bank capacitors

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

10 Commercial, Industrial, Agricultural Services

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Power-Trex. Family of Products for Temporary & Emergency Power

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Power Outlets. Application Information. Features and Benefits. For Farm, Home and Industry U010C

The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM

SECTION MOTOR CONTROL

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

APPENDIX B: LISTS OF APPROVED MATERIALS

Generator Fire Safety: Generator assemblies should be located outside the building.

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

A. Submit manufacturer's literature and technical data before starting work.

Transcription:

Lighthouse Power Pedestal One of our most popular units, the all-purpose Lighthouse pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized for its practicality and exceptional durability. Above: Lighthouse Power Pedestals, Cordova Marina, Alaska 7 EATON CORPORATION Marina Power Equipment www.marinapower.com 1-800-723-8009

Lighthouse Power Pedestal Standard Features Available Options Dimensions Receptacle Configurations For a complete listing of the receptacle configurations available for the Lighthouse power pedestal, see page 19. Standard Features Photocell Controlled 13 Watt Fluorescent Light (Clear Lens or Amber Lens for Bug Reduction) Lockable Weatherproof Doors which Protect Breakers and Receptacles while in use (a requirement of N.F.P.A. 303 and NEC Art. 555) Hose and Cable Brackets Heavy Polycarbonate Housing with a Two-Part Polyurethane Coating for a UV Resistant, Long Lasting Finish Available Options Digital Electronic Metering (One, Two or Three Element Meters Available) Built in Meter Socket 20A /125V GFI Receptacle (Max of 2 GFI Receptacles per Pedestal)* High-Speed Internet Connections Radio Transmission of Meter Output * 20 Amp GFI receptacles are not to be used for shore power. Dimensions LIGHTHOUSE IN. MM Height: 44 1117.6 Width: 13.75 349.25 Depth: 13.75 349.25 Single or Dual Phone and/or Cable TV Connections Copper Bus Bar with Ratings from 250 to 500 Amps Hinged Base Providing Easy Access for both Installation and Maintenance Single or Dual Steel 1/4 Turn Ball Valves with 3/4 Hose Bibs and Stainless Steel Handles Backlit Faceplate for Easy Receptacle Plug-in at Night Cable & Internet Connections Bus Bar Hinged Base Optional Meter Socket www.marinapower.com 1-800-723-8009 Marina Power Equipment EATON CORPORATION 8

PARTS LISTS # Part # Part 1 Top - Only 28 Bulb 2A Amber Lens 29 1/2" Silcock 2B Amber Lens - 3 Piece 30 Wiring (per foot) 3 Counter 31 Stainless Steel Screws 4 External Cover 32 Light Fuse 5A Door 33 Fuse Holder 5B Door - Newport 34 Touch-up Paint Kit 5C Door - Stainless Steel 35 Aluminum Face Plate 6 100A Breaker Cover 36 Buss Bar Assembly 7 100A Receptacle 37 Main Housing - Complete 8 Hose & Cable Brackets 38 Stainless Steel Mouting Stand 9 Main Housing - Complete 38 Aluminum Mounting Stand 9B Stainless Steel Door 39A Phone Shield 10 Aluminum Hinge 39B Phone/Cable Conduit 11 Hose Adapter 40A Conduit Male Adapter 11A Water Assembly - Complete 40B Male Coupling 12 Water Mounting Plate 41 Newport Mounting Brackets 13A Pedestal Base w/ Buss Bars 42 Pedestal Main Housing 13B Pedestal Base w/o Buss Bars 43 Mounting Feet 14 Photocell 44 Red Strobe Light 15 Ballast 45 Firehouse Top w/ Strobe Light 16 Socket 46 Clear Door 17 Meter 47 Life Ring 18 Face Plate - Amber Lexan 48 Blank Access Panel 19 Receptacle 49 Door / Life Ring Trigger 20 Breaker Plate - Noryl Molded 50 Firehouse Buss Bar 21 Breaker 51 Clear Door Hasp 22 Terminal Barrier Isolators 52 Life Ring Bracket 23A Copper Buss Bar 53 Fire Extinguisher 23B Copper Buss Bar 54 RV Phone & Cable TV Assembly 24 Wire Terminations 55 Power Tower Light Switch 25 3/4" Ball Valve 56 Stainless Steel Access Panel 26 Backflow Preventer 27 Phone/Cable TV Assembly

Page 1 Eaton Electrical Inc. 1000 Cherrington Parkway Moon Township, PA 15108 United States tel: 1-800-525-2000 www.eatonelectrical.com General Specifications for the Lighthouse Power Pedestal All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements A. Shall be tested and certified to be in compliance with ANSI/UL 231 entitled power outlets. B. If a laboratory other than UL is used, that laboratory must certify, in writing, that the power outlet has been tested and meets all of the requirements of ANSI/UL 231, including 746C polymeric materials, and that the unit will pass the 94VO-5V flame test. C. Shall be certified to meet all sections of NFPA 303, Fire Protection Standards for Marinas and Boatyards 2006 Edition. D. Shall meet 406.8 (B)(2)(a) of the National Electrical Code NFPA 70, i.e., A receptacle installed in a wet location shall be installed in a weatherproof enclosure, the integrity of which is not affected when the attachment plug cap is inserted. E. The receptacles shall be mounted at a down angle of 35 degrees or greater from vertical to relieve the strain of the cable weight on the receptacle locking mechanism. Part II. Products: 2.1 Acceptable Manufacturers Power Pedestals/ Lighthouse Enclosures A. Eaton Corporation Marina Power and Lighting 149 Warwick Court Williamsburg, VA 23185 Toll Free 1-800-723-8009 2.2 Power Pedestals/Lighthouse Enclosures General A. Housing: 1. The housing shall be constructed of 1/4 thick injection molded resin material and shall be coated with a UV-resistant polyurethane. It shall be UL listed as a type 3R weatherproof enclosure. B. Wiring: 1. The power pedestal shall be completely pre-wired at the factory to the load side of the compression lug assembly. 2. All load copper wiring shall be of high stranding and tin-plated to resist corrosion. 3. The maximum size of the line wiring shall be 350 MCM direct feed or #4/0 AWG loop feed. C. Loop Feed Bus Bar System: 1. The bus system shall be a 3/8 16 silicon-bronze stud with a silicon-bronze Belleville type washer. The 3/8 16 siliconbronze hex-nut shall be torqued to 200 inch-pounds. 2. Double Barrel Mechanical Lugs (Optional) rated for copper and aluminum are available. D. Grounding: 1. All exposed metallic parts must have an integral ground that is a part of the equipment grounding system. E. Receptacles: 1. All receptacles shall be of the corrosion resistant type conforming to NEMA L 5 and/or NEMA L 6 requirements and are rated for marine use. 100 amp receptacles should conform to IEC and CEE standards. 2. All receptacles shall be mounted at an angle that is a minimum 35 degrees from vertical and located behind a lockable weatherproof hinged door that is under tension to ensure proper closing pressure when the receptacle is or is not in use. 3. All receptacles shall be mounted at least 30 above the dock. F. Circuit Breakers: 1. All breakers for receptacles shall be of the thermal-magnetic type, 10,000 AIC, and shall be UL listed. 2. Circuit breakers for the receptacles shall be covered with the same lockable door that covers the receptacles. 2.3 Power Pedestals A. Base: 1. The base shall be hinged to the upper unit to provide ease of wiring and plumbing and shall be of injection molded resin material construction with mounting feet that are 3/4 in thickness. B. Hose/Cable Bracket: 1. Each pedestal shall have brackets capable of holding a 50 length of 5/8 water hose or 50 of 50 amp 4 conductor boat S.O. cord. C. Receptacles: 1. Receptacles for boat users shall be a locking and grounding type, either single-phase, 125 volt 30 and/or 50 amps, and 125/250 volt 50 and/or 100 amps. Three-phase 120/208 volt 100 amp or three-phase 480 delta or wye 100 amps. D. Lighting: 1. Each pedestal shall be equipped with a non-metered light. The light shall be a 13 watt fluorescent biaxial light that is controlled by an electromechanical photocell. 2. The light shall provide 360 degree dock illumination such that indirect lighting extends from station to station with a minimum dock lighting of one foot candle at 15 feet. The lighting shall not interfere with boaters navigation.

Page 2 Eaton Electrical Inc. 1000 Cherrington Parkway Moon Township, PA 15108 United States tel: 1-800-525-2000 www.eatonelectrical.com General Specifications for the Lighthouse Power Pedestal E. Circuit Breakers: 1. Circuit breakers for 30 amp receptacles shall be a single-pole, 125 volt, 30 amp thermo-magnetic type. 2. Circuit breakers for 50 amp receptacles shall be single-pole 125 volt 50 amp or two-pole 125/250 volt, 50 amp thermomagnetic type. F. Metering (Optional): 1. The pedestal shall be equipped with fully electronic meters that display the kilowatt-hours used at each slip on a nonresettable digital counter that is protected from the weather. The accuracy of the meters must be certified by the manufacturer to have a 125 ampere rating and no more than a two percent error when tested in accordance with ANSI-C12.1. (California requires 1%.) G. Telephone and Cable TV (Optional): 1. Each pedestal shall be equipped with one or two outlets for each slip. Each outlet shall contain a marine telephone locking receptacle and one (1) male cable TV connector under a weatherproof cover. H. Water (Optional): 1. The water connection shall be one (1) 3/4 inlet, which divides into two (2) 3/4 hose bibs. The valves shall be 1/4 turn ball valves. I. Power Pedestals for A.D.A Slips (Designated as Handicap Accessible): 1. Power pedestals installed on designated handicap accessible slips shall comply with the guidelines of the Americans With Disabilities Act of 1990. UL is a registered trademark of Underwriters Laboratories Inc. NFPA is a registered trademark of the National Fire Protection Association. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. 2006 Eaton Corporation All Rights Reserved Printed in USA Publication No. PS0060005E / Z4977 October 2006

Receptacle Configuration Chart SHORE POWER RECEPTACLES Note: Receptacle configuration is not available for this power pedestal. * 20 Amp GFI receptacles are not to be used for shore power. Side One Side Two Phase Lighthouse Lighthouse-SS Hatteras Light Newport Harbor Mate Power Outlets Power Outlets Maximum GFI* Maximum GFI* Maximum GFI* Maximum GFI* None None 1 2 2 3 3 30 00 1 2 2 2 2 30 30 1 2 2 1 1 30-30 30 1 2 2 30-30 30-30 1 2 2 30 50 1 2 2 0 1 30-30 50 1 2 2 30-30 30-50 1 2 2 30-30 50-50 1 2 2 30-50 30-50 1 2 2 30-50 50-50 1 2 2 50 None 1 2 2 1 2 50 50 1 2 2 1 50-50 50 1 2 2 50-50 50-50 1 2 2 100 None 1 2 2 100 50 1 2 2 100 50-50 1 2 2 100 100 1 2 2 100 None 3 2 2 100 50-50 3 2 2 100 100 3 2 2 19 EATON CORPORATION Marina Power Equipment www.marinapower.com 1-800-723-8009