B-PC20 Power Close Module

Similar documents
B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

USERS GUIDE LO-21U LOCKOUT RELAY

Senior Swing Control Box. Table of Contents

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

MODEL 422 Submersible Pump Controller

STR3. Step Motor Drive. User Manual

Application Engineering

ECM-MSPD. Installation, Operation, and Maintenance Manual

Electro-Mechanical Swing Operator. Table of Contents

Roll Up Door Operator

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Water Valve Shutoff. WVS Water Valve Shutoff

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Application Engineering

GLM SERIES CONTROL Users Manual Rev:

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

Model 930 Power Control System Instruction Manual



INSTALLATION SHEET MODEL 618 SHEET NO ISSUE 2. The 618 can be mounted on the car doors using the standard fixing kit provided (Fig 1).

Power Operators. Requirement. Approved Manufacturers. -All Operators To Be Electrically Powered -Operators To Be Aluminum (BHMA 689) Finish

Gate & Door Controller with LCD and Intelligent Technology

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

CB-9 CONTROL BOARD INSTRUCTION MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL

Triple Output Power Supply

CONTROLLER DIAGNOSTIC GUIDE

Induction Power Supplies

MCC Automatic Start-Stop Microcomputer Charger Control

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

GCU-10. Automatic Engine Control Unit Operators Manual

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Quick Setup Guide for IntelliAg Model YP Air Pro

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

Installation Instructions

Vission 20/20 micro-controller. Operation and service manual

CAN-Translator. User s guide

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Ball Speed Display Manual

Aftermarket Interface Module

5700 SERIES Low Energy Power Operator

DC Variable Speed Drive Panel

SR3-mini. Step Motor Drive User Manual. AMP & MOONS Automation


Dielectric Withstand Tester

INSTALLATION AND OPERATIONS MANUAL FUEL POLISHING MODULE (FPM)

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Electronic timers CT-S range Function diagrams

Continental Hydraulics Installation Manual CEM-AA-A

RVS-DN Digital Reduced Voltage Motor Starter

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

GE Sensing & Inspection Technologies

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

Flight Systems. Replacement for KASSEC DESCRIPTION

AeroVironment Universal Solar Pump Controllers

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

QUICK INSTALLATION GUIDE

TEL: G&C Electronics CC E. T.

An ISO 9001:2008 Registered Company

LCN AUTOMATIC OPERATORS

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

5800 Series ADAEZ PRO Low Energy Operator

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

Hunter Automatics HA-8. Installation Manual

APOLLO Gate Operators, Inc.

INSTALLATION GUIDE Table of Contents

Setup and Programming Manual

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

RVS-DX Digital Reduced Voltage Motor Starter

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

Indoor air quality sensor.

SW10 (Full Power) & SW19 (Low Energy)

GTWY515, GTWY516* Fast Idle, Shift Interlock, I/O Ford Transit Introduction

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

ADJUSTABLE FREQUENCY CRANE CONTROLS

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

What s on your truck? MOTIONACCESS, LLC. Installation & Operation Manual

Single or Double 240VAC motor control for domestic and industrial gates and doors.

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

CF-10 Option Operating Instructions

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTALLATION INSTRUCTIONS

Start-Up, Operation and Service Instructions

Energy Division

Transcription:

B-PC20 Power Close Module Instruction Manual Document number: B-PC20-C Release: V1.2 Date: OCT 12,2011

! WARNING This control must be adjusted/serviced by a qualified person. The service technician must be familiar with the latest ANSI A159.10/19 standards. To provide additional safety, a presence sensor should be installed on the push side of the entrance and connected to the cancel input of the PCM (Power close module). NEVER sacrifice the safe operation of the automatic door for an incomplete solution. Call the factory for technical support. 2

Index 1 Module Physical Information... 4 1.1 Module Dimensions...4 1.2 Mounting holes (Dimensions in inches)...5 1.3 Module Physical Description...6 1.4 Electrical Characteristics...7 1.5 Typical Installation...7 2 Signal Descriptions... 8 2.1 Activation Input/Output...8 2.2 Cancel Input...8 2.3 Door Close Switch Input...8 2.4 Back Check Input...8 2.5 Latch Input...8 3 Potentiometer Descriptions... 9 3.1 PC Trigger Potentiometer...9 3.2 Current Limit Potentiometer...9 3.3 PC Force Potentiometer...9 4 Feature Descriptions... 10 4.1 PC Activate Delay...10 4.2 PC Timeout...10 4.3 Hold at Closed Option...10 4.4 PC at Back Check Option...10 5 Terminal Block J1 Pinout Descriptions... 11 6 Select Switch Definitions... 12 7 J3 Hold Option... 12 8 J3 Power Close at Back Check Option... 12 9 Setup Procedures... 13 9.1 Module Adjustment...14 9.1.1 Power Close Select...14 9.1.2 Power Close Settings...14 9.1.3 Hold Feature...14 3

The B-PC20 Power Close module can be used where automatic door operators are installed. Where the building/room or wind pressure is too high, the Power Close module will ensure that the door will fully close properly. This control is user friendly and simple to install and set. The B-PC20 module is to be installed between the main door operator control and the DC motor. Visual indicators allows the installer to view the key points of the power close cycle. All settings are adjusted/updated in real-time which makes this control very simple to tune to the desired values. This module can be used on 75 to 160 Volts DC motors. 1 Module Physical Information 1.1 Module Dimensions 3.7" 3.0" 1.35" 4

1.2 Mounting holes (Dimensions in inches) 1.30 0.25 0.20 1.00 1.00 0.20 0.20 5

1.3 Module Physical Description (FRONT VIEW) PC trigger potentiometer/indicator Current limit potentiometer/indicator PC force potentiometer/indicator Part Number 14-13139 Indicator for Latch PC Select switch (Engage power close at) Indicator for Close PC Latch (Switch at top) Both (Switch at center) Close (Switch at bottom) (SIDE VIEW) 2 4 6 J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 J3 1 3 5 2 4 6 J3 Options Option Condition Jumper Power close at back check Hold close 1 3 5 Enabled Disabled Enabled Disabled Insert jumper between pins 1 & 2 Remove jumper between pins 1 & 2 Insert jumper between pins 4 & 6 Remove jumper between pins 4 & 6 6

1.4 Electrical Characteristics Parameter Power IN Motor PC output PC timeout Logic input Voltage range Logic output sink current Operating Temperature Dielectric strength (Between motor IN/OUT and logic IN/OUT) MIN TYP MAX Unit AC 12 24 36 V DC 16 32 50 V Close 3-70 %PWM Latch 2-35 %PWM Hold 2-18 %PWM BK - 22 - S Close - 15 - S Latch - 4 - S - - 75 V - - 400 ma -40-85 C - 1500 - V 1.5 Typical Installation Door mounted - Safety Presence Sensor (Push side of door) +24VDC Ground Common N.O. Handicap activation push button Door close switch (Contact closed when door is fully closed) Main control 24VDC Activation signal Logic Ground Back check signal Latch signal Control motor output (NEG) Control motor output (POS) NO NC COM Motor Latch switch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B-PC20 NO NC COM Backcheck switch 24VAC (1A) Transformer 120VAC 7

2 Signal Descriptions 2.1 Activation Input/Output Use to cancel power close and to activate the door to re-open if the door pushes to hard on an object. Input - When active (circuit is closed), the activation input cancels the power close cycle to allow the door to open. The module has a PWM detector which also can cancel the power close cycle in the presence of a PWM signal and allow the door to open. Output - Activation output is used to activate the door to re-open if the door pushes too hard against an object. (See Current Limit Potentiometer) To use this feature the activation output must be connected to the activation of the main control. 2.2 Cancel Input Use to cancel power close when a push side door mounted presence sensor is active. When active (circuit is closed), the cancel input disables the power close module. This input can be used with a sensor to shut the module down when the door is approached from the push side and used manually or to control the module with an ON/OFF switch. 2.3 Door Close Switch Input This connection signals the PCM that the door is closed. When active (circuit is closed), the door close switch input indicates that the door is fully closed and terminates the power close cycle. If a jumper is installed on J3 pin 4 and 6, the door will hold closed when the door close switch input is active. 2.4 Back Check Input This connection signals the PCM that the door has reached back check. When active (circuit is closed), this signal is used to prevent power close to engage while the door is in the back check area. This feature can be disabled by installing a jumper on J3 pin 1 and 2. 2.5 Latch Input This connection signals the PCM that the door has reached latch check. This signal allows power close to engage at latch and/or at close when PC trigger is met. During power close, at the latch area, the door close speed is monitored to regulate the speed while still creating the proper force. 8

3 Potentiometer Descriptions 3.1 PC Trigger Potentiometer This potentiometer adjusts at what closing speed the PC will engage. This potentiometer adjusts the sensitivity of power close trigger. This setting is compared to the closing speed of the door. When the trigger is achieved the corresponding green indicator will flash. 3.2 Current Limit Potentiometer This potentiometer tells the PCM how hard the door should push against an object before it reopens. This potentiometer adjusts the sensitivity of the current monitor. During power close, the current to the motor is monitored. If the current exceeds the allowed limit, power close is canceled and disabled for 3 seconds, the current limit red indicator is lit and a re-activation signal is generated on the activation output. This setting should be adjusted to prevent the PCM from pushing too hard against an object. 3.3 PC Force Potentiometer This potentiometer adjusts how hard the PCM will push against an object while closing. This potentiometer adjusts the power close strength. Power close force at latch is reduce by 50%. Hold closed force range is 2-18%. When PC is active, the PC force green indicator is lit. 9

4 Feature Descriptions 4.1 PC Activate Delay This feature determines how long the door will push against an object before PC kicks in. When the door is closing and encounters enough resistance to trigger the PCM, a delay of 3 seconds will begin. The PCM will engage after the 3 second time delay. During the delay, if the resistance disappears, the delay and power close will be canceled. When the resistance is met again, the delay will restart at 3 seconds. 4.2 PC Timeout This feature determines how long the PCM stays engaged during closing. When power close is engaged a timeout timer is loaded. When the timeout delay expires the power close is canceled. The value of the timer is 22 seconds for back check, 15 seconds for close and 4 seconds for latch. 4.3 Hold at Closed Option This jumper enables the PCM to hold the door closed. When the door is fully closed (Door close switch is closed) and jumper J3 is present on pin 4 and 6, a hold force is applied to keep the door closed. 4.4 PC at Back Check Option This jumper enables the PCM to engage PC during the complete closing cycle. To make power close available at back check, install a jumper on J3 pin 1 and 2. 10

5 Terminal Block J1 Pinout Descriptions PIN Signal J1.1 Activation IN/OUT J1.2 Ground B J1.3 Cancel input J1.4 Ground B J1.5 Door close switch input J1.6 Ground B J1.7 Back check signal Definition Connect this signal to the activation input on the door control. Isolated ground reference B Connect this signal to the push side door mounted sensor. This signal cancels power close when tied to ground B. Isolated ground reference B This signal tied to ground B will halt the power close cycle and if the Hold Closed option is selected, a hold force will be created. The hold force will be removed if an activation signal is received, if cancel signal is closed, if the door closed switch becomes opened or by removing the J3 jumper between pin 4 and 6. Isolated ground reference B Connect the back check switch between pin J1.7 and J1.8 This signal tied to ground A will prevent power close to engage while the door is held fully opened (At back check). This feature can be disabled by adding a jumper to J3 pin 1 and 2. J1.8 Ground A J1.9 Latch signal J1.10 Ground A J1.11 Motor + (NEG) J1.12 Motor - (POS) J1.13 Control + (NEG) J1.14 Control + (POS) J1.15 24VAC/DC (1A) input J1.16 Isolated ground reference A Connect the latch switch between pin J1.9 and J1.10 During closing, this signal allows power close to engage at latch and/or at close when the PC trigger level is met. Isolated ground reference A Connect to the motor negative Connect to the motor positive Connect to the main control motor negative output Connect to the main control motor positive output Connect to a 24VAC (1A) transformer 11

6 Select Switch Definitions Switch Position Definition Latch Power close at latch only Both Power close at latch and close Close Power close at open only With the option switch in the "Latch" position, power close will be possible at the "Latch" area only. With the option switch in the "Close" position, power close will be possible at the "Close" area only. And with the option switch in the "Both" position, power close will be possible at the "Latch" and the "Open" areas. 7 J3 Hold Option J3 Jumper Definition No jumper (on pins 4 and 6) Hold closed option disabled Jumper on pins 4 and 6 Hold closed option enabled With the door fully closed (Door close switch contact closed) the power close module will apply a constant pressure to keep the door closed. The hold force can be canceled by opening the contacts of the door close switch, with the cancel signal, an activation or by removing the J3 jumper between pins 4 and 6. When the hold feature is active the PC force LED will flash. 8 J3 Power Close at Back Check Option J3 Jumper Definition No jumper (on pins 1 and 2) PC at Backcheck option disabled Jumper on pins 1 and 2 PC at Backcheck option enabled With the jumper installed on J3 pins 1 and 2, the module will provide power close at back check if the option switch has "Close" selected. Note: If this option is used, additional door mounted safety sensor(s) should be installed to prevent the door from closing when a pedestrian is near the entrance. 12

9 Setup Procedures Before applying power to the operator, make all necessary connections (Refer to the wiring diagrams at the end on the document as an example). The figure below shows the PC allowed areas for different settings. PC allowed BK Close Latch Door A B C D E Setting Select Switch Position PC at BK Jumper A Both IN B Both OUT C Close IN D Close OUT E Latch OUT 13

9.1 Module Adjustment 9.1.1 Power Close Select Set the slide switch to the desired power close setting. The yellow lights indicate the selection. The possible options are; power close at latch, at close or at both (at close and latch). PC at back check is also available by adding a jumper. (Refer to the figure above for details). Note: 1- Power close on "Close" will be possible only after the control detects the present of a back check switch. 2- A power close time-out will cancel power close when the timer expires. The timeout value are 4 seconds for power close at latch and 15 seconds for power close at close or at both (at close and latch). 9.1.2 Power Close Settings 9.1.2.1 Power Close Trigger During the closing cycle, adjust the "PC trigger" potentiometer so that the "PC trigger" green light comes "ON" at the desire speed. (This setting must be adjusted at the door position in reference to the selection made to the power close option switch.) 9.1.2.2 Power Close Force During a power close, adjust the "PC force" potentiometer to get the desire closing force. Make the adjustment when the "PC force" green light is "ON". 9.1.2.3 Current Limit During a power close, obstruct the door (using a heavy object) and adjust the "Current limit" potentiometer to get a "Current limit" failure (A red light will come "ON", power close is cancelled and the door will re-open if the "Activation IN/OUT" is connected to the main control). 9.1.3 Hold Feature If the hold closed feature is required install/move the jumper to J3 on pins 4 and 6. A door close switch must be installed for this feature. When the hold feature is active the PC force LED will flash. For further information contact technical support 14

15

16