The Anatomy of a Drum Filter
Theory of Operation Dirty air is introduced into the Drum Filter Enclosure The Main System Fan pulls the air across the filter media The dirty particles are vacuumed off the media by vacuum nozzles in the drum chamber Dirty particles are then returned to the process or collected in an off-line collector 1. Dirty air into enclosure 3. Dirty media is vacuumed by nozzles 2. Main System Fan pulls across the filter media 4. Dirty particles are returned to process or collected in off-line machine
Drum Filter System Styles Ibis offers the following drum filters: Outside Drive (which can be CE certified): All drive components are located outside the Drum Filter Enclosure. G-3 concept: Outside Drive Drum Filter system designed specifically for OSHA, NFPA, and ATEX compliance. Inside Drive (which can not be CE certified). All drive components are located inside the enclosure.
Outside Drive G-3 Drum Filter System Layout Radius Elbow Inlets SRV (Optional) Additional Filtration Stage (Optional) Main Fan Nozzles Rear Bearing Stand & Drive Components Drum Filter Nozzle Fan
Design features of G-3 Drum Filter Δ Designed to help meet requirements from NFPA, ATEX, CE, FM, OSHA, etc. Δ Clean Floor design and smooth enclosure interior to prevent dust accumulation. Δ No electrical components or connections within the airstream Δ All potential spark generating issues resolved Δ Hydrex media: 85% to 10 micron efficiency Δ Large Radius Elbow Duct Connection points for improved Airflow
G-3 Stage 1 Rotary Drum Filter Multiple Configurations Model number indicates drum diameter + number of cage sections 7-4 drum filter indicates 7 foot drum diameter and 4 cage sections Hydrex Media 85% > 10 Micron
Additional Stages of Filtration (Optional) Δ Stage 2: Pocket Filter, up to 80% efficiency > 5 Micron Δ Stage 3: Pleated Bag Filter, up to 95% efficiency > 1 Micron Δ Stage 4: HEPA Filter, up to 99.99% efficiency >.3 Micron Stage 2 Pocket Filter Stage 3 Pleated Bag Filter Stage 4 HEPA Filter
Stage 2 & 3 Frame System Δ Stage 2& 3 uses a custom designed, globally configured frame that fits a variety of systems Frame installed Filter being installed
Inlet Air Flow Diagram
Clean Floor Design Coves
High Velocity Inlet Panel The heart of the Ibis Clean Floor Design. The slot is sized based on the system air flow for better distribution and velocity within the drum chamber.
High Velocity Inlet in Enclosure roof panels
End View Inlet Air Flow Diagram Drum Radius Filter Elbow Inlet Diverter Valve
Nozzle Cleaning Options Ibis offers the following nozzle cleaning options for a drum filter system: Sealed Rotary Valve Poppet Valve Pneumatic Manifold Diverter Valve Sealed Rotary Valve Pneumatic Manifold Poppet Valve Diverter Valve
Sealed Rotary Valve (SRV) Δ Custom CAM design Δ Can clean one or two nozzle positions at a time Δ Connected to variable speed drive Δ Positive sealing discs with self cleaning features
Poppet Valve Δ Controls flow of air and material through ducting Δ Internal disc provides positive seal Δ 4-way solenoid operated pneumatic valve governs cylinder travel Δ Wide range of pneumatic components available Δ Design allows for custom cleaning program Airflow
Pneumatic Manifold Δ For 2-8 position drum filter systems Δ Multiple Diverter Valves allow for sequential cleaning of one position at a time Diverter Valve Δ Wide range of pneumatic components available
Fire Protection Δ Typically we use standard threaded NPT pipe that is customized to fit your drum filter, but customized solutions are possible.
Optional Components Δ Ibis Drum Filter Systems can be modified extensively into different configurations to fit your needs. Some of the additional components we offer are: Δ Contamination Collectors to collect foreign material that may enter lines. Δ Customizable Fire Protection and Pneumatics Panels for Fire Protection and all Pneumatics Controls Δ Nozzle Fan Filters Δ Deluge Systems Δ Dry Chemical Systems Δ Inlet Pressure Control Δ Drum Rotation Monitoring Δ Cyclone
Cyclone Used in systems where dust is not returned to the process Removes dust and particles from airstream using vortex separation Airlock available
Bleed Valves Δ Maintains proper filter airflow when servicing multiple production machines Δ Wide range of pneumatic components available Δ Cylinder position sensors Δ Sealed blade Δ Adjustable slide gate damper Δ Protective safety guards
Contamination Collector Slide Gate Δ Inline, manual collector Δ Traps the following materials: Δ Large pieces of non-woven Δ Back Sheet Δ Tissue Δ Any other additional foreign objects Δ Sensor tells operator when full Δ Internal basket changeable while line is running. Airflow Sensor Internal Basket * A more compact design with Jacobs or DIN angle ring Flange connection can be added
Fire Protection Panel Δ Our Millennium fire protection panel offers greater control over your fire protection system. Δ Allows for single point plant water connection Δ Welded Components Δ All connections are 150 psi flanges Δ System is pressure tested prior to shipment to facilitate quicker install times
Nozzle Fan Filters Δ Eliminates very fine dust returning to the drum filter Δ Increases primary drum filter and secondary passive filter life Δ Includes flameless explosion vent, no external venting required Δ Unit Isolation Diverter Loop Δ Front or rear access door Δ Cartridge filters are 99% efficient to 1 micron
Control Panels Δ Ibis control panels are highly customizable to fit your system needs Δ Human Module Interfaces Available
Outside Drive Drum Side View Nozzles Plenum Wall Rear Drum Drive Stand Seal Cage Center Cage Center Cage End Cage
Outside Drive Drum Top View Plenum Wall Seal Cage Center Cage Center Cage End Cage Rear Drum Drive Stand Nozzles
Outside Drive Enclosure Top View Fan End Roof Panels 300 Bearing End Main System Fan Duct Inlet
Outside Drive Enclosure Side View Roof Panels Fan End Drive End 300 Outside Drive Main System Fan Door Panels Wall Panels
Ibis Outside Drive Drum Filter
Inside Drive Drum Side View Δ Ibis still offers the traditional style inside drive drum filter Seal Cage Center Cage Center Cage End Cage Δ Drive components are located inside enclosure Plenum Wall Δ Cannot be CE certified Inside Drum Drive & Stand Bearing Stand
Inside Drive Enclosure Top View Main System Fan Roof Panels Bearing End Fan End Air and Material Inlet
Ibis Inside Drive Drum Filter
Crating Items are typically shrink wrapped and crated based on customer requests to ensure safe shipping
Nozzle & Brackets
Diverter Valve-6 inch
Pneumatic Manifold
Do you have any QUESTIONS? 9663 Jackson Trail Rd Hoschton, GA 30548 USA Phone: (706) 654-3232 Fax: (706) 654-3888 Contact: sales@ibis-usa.com www.ibis-usa.com