Application Mini Contactors for Motors and Resistive Loads

Similar documents
Application Mini Contactors for Motors and Resistive Loads

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

AF40... AF96 3-pole contactors Technical data

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

CA Z-EN Overload relays, CT-operated overload relays

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

IEC CONTACTORS AND OVERLOAD RELAYS

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

TAE pole Contactors

Technical Information

ASL09..S 3-pole Contactors - Spring Terminals

AE 9... AE 40 Contactors NE... Contactor Relays

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Industrial Contactors CTX 3 3P 185A - 800A

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF series contactors (9 2650)

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Modular contactor for installation into distribution boards

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

PKZ and PKE motor-protective circuit-breakers

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Protection Equipment

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

AF series contactors (9 2650)

Micro Contactor MA Series

Short form catalogue. Motor protection & control

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Bulletin 193-T1 Bimetallic Overload Relays

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Electronic overload relays EF205 and EF370

Flexible. Intelligent. Trendsetting.

4 - Miniature controls

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

B Mini Contactor V Hz

Special Purpose Fuses

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Star Series Motor protection & control

Description. Positive safety relays

MS25, MST25, MS20, MST20

MS General Information Extended Product Type: MS

Thermal overload relay TF140DU and TF140DU-V1000

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Thermal overload relay TF65 and TF96

BETA Switching Switches and Light Indicators

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Electrical sector solutions E Line family. Industry leading design in a compact package

Mini contactors, relays, contactors

Installation Contactors RIC, RAC

Technical Information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Protection Equipment. 5/2 Introduction

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Bulletin 100-D IEC Contactors

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Technical data for manual motor starters Type MS325

BC Mini Contactor VDC

Transcription:

Deliveryprogramme Contactor,3p+1N/O,4kW/400V/AC3 Partno. DILEM-10-G(24VDC) Articleno. 010213 CatalogNo. XTMC9A10TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads Subrange DILEM contactors Utilization category AC-1: Nicht induktive oder schwach induktive Last, Widerstandsöfen AC-3: Käfigläufermotoren: Anlassen, Ausschalten während des Laufes AC-4: Käfigläufermotoren: Anlassen, Gegenstrombremsen, Reversieren, Tippen Notes Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. Connection technique Screw terminals Description With auxiliary contact Pole 3 pole Ratedoperationalcurrent AC-3 AC-1 380 V 400 V I e A 9 Conventional free air thermal current, 3 pole, 50-60 Hz Open at 40 C I th =I e A 22 Max.ratingforthree-phasemotors,50-60Hz AC-3 AC-4 Contacts 220 V 230 V P kw 2.2 380 V 400 V P kw 4 660 V 690 V P kw 4 220 V 230 V P kw 1.5 380 V 400 V P kw 3 660 V 690 V P kw 3 N/O = Normally open 1 N/O Contact sequence For use with DILEM DILE Actuating voltage 24 V DC Voltage AC/DC DC operation Technicaldata General Standards IEC/EN 60947, VDE 0660, CSA, UL Lifespan, mechanical Operations x 10 6 20 Maximum operating frequency Mechanical Ops./h 9000 electrical (Contactors without overload relay) Page 05/070 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 02/13/2015 010213 - HPL-ED2014 V9.0 EN 1 / 12

Ambient temperature C Open C - 25-50 Enclosed C - 25-40 Mounting position As required, except vertical with terminals A1/A2 at the bottom Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock, 10 ms Basic unit without auxiliary contact module Main contacts, make contacts g 10 Main contacts Make/break contacts g 10 / 8 Basic unit with auxiliary contact module Main contacts make contact g Make g 10 Auxiliary contacts Make/break contacts g 20 / 20 Degree of Protection IP20 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight kg 0.17 Terminal capacity of auxiliary and main contacts Screw terminals Solid 2 mm 1 x (0.75-2.5) 2 x (0.75-2.5) Flexible with ferrule 2 mm 1 x (0.75-1.5) 2 x (0.75-1.5) Solid or stranded AWG 18-14 Terminal screw M3.5 Pozidriv screwdriver Size 2 Standard screwdriver mm 0.8 x 5.5 1 x 6 Max. tightening torque Nm 1.2 Mainconductingpaths Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to EN 61140 between coil and contacts V AC 300 between the contacts V AC 300 Making capacity (cos ϕ to IEC/EN 60947) A 110 Breaking capacity 220 V 230 V A 90 380 V 400 V A 90 500 V A 64 660 V 690 V A 42 Short-circuit protection maximum fuse AC AC-1 Type 2 coordination gl/gg A 10 Type 1 coordination gl/gg A 20 02/13/2015 010213 - HPL-ED2014 V9.0 EN 2 / 12

Rated operational current Conventional free air thermal current, 3 pole, 50-60 Hz Open at 40 C I th =I e A 22 at 50 C I th =I e A 20 at 55 C I th =I e A 19 enclosed I th A 16 Notes At maximum permissible ambient air temperature. Conventional free air thermal current, 1 pole Notes At maximum permissible ambient air temperature. open I th A 50 enclosed I th A 40 AC-3 Rated operational current Open, 3-pole: 50 60 Hz Notes At maximum permissible ambient air temperature. 220 V 230 V I e A 9 240 V I e A 9 380 V 400 V I e A 9 415 V I e A 9 440V I e A 9 500 V I e A 6.4 660 V 690 V I e A 4.8 Motor rating P kwh 220 V 230 V P kw 2.2 240V P kw 2.5 380 V 400 V P kw 4 415 V P kw 4.3 440 V P kw 4 500 V P kw 4 660 V 690 V P kw 4 AC-4 Rated operational current Open, 3-pole: 50 60 Hz Notes At maximum permissible ambient air temperature. 220 V 230 V I e A 6.6 240 V I e A 6.6 380 V 400 V I e A 6.6 415 V I e A 6.6 440 V I e A 6.6 500 V I e A 5 660 V 690 V I e A 3.4 Motor rating P kwh 220 V 230 V P kw 1.5 240 V P kw 1.8 380 V 400 V P kw 3 415 V P kw 3.1 440 V P kw 3 500 V P kw 3 660 V 690 V P kw 3 DC Rated operational current open DC - -1 12 V I e A 20 02/13/2015 010213 - HPL-ED2014 V9.0 EN 3 / 12

DC - 3 DC - 5 24 V I e A 20 60 V I e A 20 110 V I e A 20 220 V I e A 20 12 V I e A 8 24 V I e A 8 60 V I e A 4 110 V I e A 3 12 V I e A 2.5 24 V I e A 2.5 60 V I e A 2.5 110 V I e A 1.5 220 V I e A 0.3 Current heat losses (3- or 4-pole) to I th W 3.5 at I e to AC-3/400 V W 0.7 Magnetsystems Voltage tolerance DC operated Pick-up voltage 0.8 1.1 Power consumption DC operation Power consumption Pick-up = Sealing VA/W 2.6 Notes Smoothed DC voltage or three-phase bridge rectifier Duty factor % DF 100 Switching times at 100 % U c Make contact ms Closing delay ms Closing delay min. ms 26 Closing delay max. ms 35 Opening delay ms Opening delay min. ms 15 Opening delay max. ms 25 Closing delay with top mounting auxiliary contact ms max. 70 Reversing contactors Changeover time at 110 % U c Changeover time min. ms 40 Changeover time max. ms 50 Arcing time at 690 V AC ms max. 12 Auxiliarycontacts Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V AC 690 Rated operational voltage U e V AC 600 Safe isolation to EN 61140 between coil and auxiliary contacts V AC 300 between the auxiliary contacts V AC 300 Rated operational current AC-15 220 V 240 V I e A 6 Yes 02/13/2015 010213 - HPL-ED2014 V9.0 EN 4 / 12

380 V 415 V I e A 3 500 V I e A 1.5 DC L/R 15 ms Contacts in series: A 1 24 V A 2.5 2 60 V A 2.5 3 100 V A 1.5 3 220 V A 0.5 Conv. thermal current I th A 10 Control circuit reliability Failure rate λ <10-8, < one failure at 100 million operations (at U e = 24 V DC, U min = 17 V, I min = 5.4 ma) Component lifespan at U e = 240 V AC-15 Operations x 10 6 0.2 DC current L/R = 50 ms: 2 contacts in series at I e = 0.5 A Operations x 10 6 0.15 Notes Switch-on and switch-off conditions based on DC-13, time constant as specified Short-circuit rating without welding Maximum overcurrent protective device Short-circuit protection only PKZM0-4 Short-circuit protection maximum fuse 500 V A gg/gl 6 500 V A fast 10 Current heat loss at a load of I th per contact W 0.3 DatafordesignverificationaccordingtoIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 9 Heat dissipation per pole, current-dependent P vid W 0.23 Equipment heat dissipation, current-dependent P vid W 0 Static heat dissipation, non-current-dependent P vs W 2.6 Heat dissipation capacity P diss W 0 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 02/13/2015 010213 - HPL-ED2014 V9.0 EN 5 / 12

10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Magnet contactor, AC-switching (EC000066) Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching (ecl@ss8-27-37-10-03 [AAB718011]) Rated control supply voltage Us at AC 50HZ V 0-0 Rated control supply voltage Us at AC 60HZ V 0-0 Rated control supply voltage Us at DC V 24-24 Voltage type for actuating DC Rated operation current Ie at AC-1, 400 V A 22 Rated operation current Ie at AC-3, 400 V A 9 Rated operation power at AC-3, 400 V kw 4 Rated operation current Ie at AC-4, 400 V A 6.6 Rated operation power Ie at AC-4, 400 V kw 3 Modular version No Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as normally closed contact 0 Connection type main current circuit Screw connection Number of normally closed contacts as main contact 0 Number of main contacts as normally open contact 3 Approvals Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking UL File No. E29096 UL Category Control No. NLDX CSA File No. 012528 CSA Class No. 3211-04 North America Certification UL listed, CSA certified Specially designed for North America No 02/13/2015 010213 - HPL-ED2014 V9.0 EN 6 / 12

Characteristics 1: Overload relay 2: Suppressor 3: Auxiliary contact modules Enclosure totally insulated 02/13/2015 010213 - HPL-ED2014 V9.0 EN 7 / 12

Squirrel-cage motor Operating characteristics Starting:from rest Stopping:after attaining full running speed Electrical characteristics Make: up to 6 x rated motor current Break: up to 1 x rated motor current Utilization category 100 % AC-3 Typical applications Compressors Lifts Mixers Pumps Escalators Agitators Fans Conveyor belts Centrifuges Hinged flaps Bucket-elevators Air conditioning system General drives in manufacturing and processing machines 02/13/2015 010213 - HPL-ED2014 V9.0 EN 8 / 12

Extreme switching duty Squirrel-cage motor Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 x rated motor current Break: up to 6 x rated motor current Utilization category 100 % AC-4 Typical applications Printing presses Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines 02/13/2015 010213 - HPL-ED2014 V9.0 EN 9 / 12

Switching duty for non-motor loads, 3-pole, 4-pole Operating characteristics Non-inductive or slightly inductive loads Electrical characteristics Make: 1 x rated current Break: 1 x rated current Utilization category 100 % AC-1 Typical applications Electric heat 02/13/2015 010213 - HPL-ED2014 V9.0 EN 10 / 12

Short-time loading, 3-pole Time interval between two loading cycles: 15 minutes Dimensions 02/13/2015 010213 - HPL-ED2014 V9.0 EN 11 / 12

2DILE- + MVDILE + DILE 2DILE- -G + MVDILE + DILE Additionalproductinformation(links) IL03407009Z(AWA2100-0882)Minicontactorrelay IL03407009Z (AWA2100-0882) Mini contactor relay UL/CSA: Approved rating data ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84 02/13/2015 Eaton Industries GmbH http://www.eaton.eu 12/2014 by Eaton Industries GmbH 010213 - HPL-ED2014 V9.0 EN 12 / 12