OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

Similar documents
OmniAire 2200 Operations and Maintenance Manual

2200C. Operation and Maintenance Manual. HEPA Air Filtration Machine BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC.

2000C. HEPA Air Filtration Machine. Operation and Maintenance Manual

OmniAire Portable Air Cleaner OA1200PAC

Omniaire 1000V Instruction Manual-8/05

MiniForce II. HEPA Air Filtration Machine. Operation and Maintenance Manual

OmniAire 600N Operations and Maintenance Manual

OmniAire 2200C Operations and Maintenance Manual

1600PAC. HEPA Air Filtration Machine. Operation and Maintenance Manual

Captivate Illuminated Mirror Light

Specialists in HEPA Filtration and Negative Air Machines

MODEL MC1500 Installation and Operation Manual Important:

Air Purification Unit. Operation and Maintenance Manual

Air Purification Unit. Operation and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Specification Grade Contemporary Wall Mount/Technical Installation Data

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

FA1 Series Air Filtration System. Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

INSTALLATION INSTRUCTION Bollard Light 12V

Portable Lawn Sprinkler and Multi-Use Pump

Portable HEPA System

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F


MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

OWNER S MANUAL OM F

Cable Cubby 1202 and 1402 Installation Guide

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

MC2500. Installation and Operation Manual

MODEL FA1 Mini Air Filtration System. Operations Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Troubleshooting Guide

MODEL MA4210 Installation and Operation Manual Important:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Installation Instructions

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

Cable Cubby 650 UT Installation Guide

MODEL SAFETY & INSTRUCTION MANUAL

MODEL SCA Installation and Operation Manual Important:

Operating Manual PFB-2500

Miracle State Of The Art Air Filtration System!

Installation Instructions

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

HEPA AIR FILTRATION SYSTEM

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

PBA Series Prelube Controls

Operating Manual MAC-21 VFD

Installation Instructions

Record the serial number and date of purchase in your manual for future reference.

GETTING STARTED WITH IN-WALL DIMMER SWITCH

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

XeteX, Inc. All Rights Reserved.

X100P Load Bank. Read all instructions before using the load bank. Contents

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

Affordable portable filtration unit

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

MODEL FA5 Air Filtration System. Operations Manual

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

INSTALLATION INSTRUCTIONS

3M AEROSPACE & COMMERCIAL TRANSPORTATION DIVISION St. Paul, MN USA or or Made in USA

TOTALINE ELECTRONIC AIR CLEANERS

Air Boss Model M3000. Industrial Air Cleaner READ AND SAVE THESE INSTRUCTIONS. TRION

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

Filters for fixed installations

Operations and Service Manual. X30208 Load Bank

MNBE-8D2x2 INSTRUCTIONS

HEPA-AIRE PORTABLE AIR SCRUBBER-PAS1800 INSTRUCTION MANUAL

Fan Relay Board (FRBii) Assembly

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

HEPA Filtration. HEPA DM 3000P Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

MODEL GS1-100 Air Filtration System. Operations Manual

Cable Cubby 1200 and 1400 Installation Guide

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

Air Boss M-Series Media & Adsorption Air Cleaner

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

Operations and Service Manual. XE400D-SB Load Bank

Cable Cubby 500 and 700 Installation Guide

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Further information: Berriman Associates Model 850P.2 Owners Manual

OWNER S MANUAL. Installation and Service Manual

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

CA3000C & CA6000C Cartridge Air Cleaners

EXT DUCTLESS FUME HOOD

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

UNPACKING THE UNIT. Alcohol cleaning pad

XS400 Load Bank. Read all instructions before using the load bank. Contents

PHOENIX MINI-GUARDIAN

Transcription:

OmniAire 18000 Omnitec Design, Manufacturing Air Purification Equipment Since 1988 For your larger projects the OmniAire 18000 is the right tool. The modular design of this system allows for ease of transport and many different configuration choices. The 3 HEPA filter cabinets are connected to the blower with 18" flex ducts which allows them to be placed up to 25 feet away from the blower, and also allows them to be placed in different areas if necessary. The design of the HEPA filter cabinets allows for the use of bag filters or carbon vapor trap filters in place of the HEPA filters if required. OmniAire 18000 Airflow - 18000 cfm, 2-22" vaneaxial fans with 7.5 hp motors. Airflows are based on blower manufacturer curves. Different HEPA filters may cause the flow to vary. Weight - Blower Unit - 900 lbs., Filter Cabinet 200 lbs. with filters installed. Dimensions - Blower Unit - 32" wide 72" high 43" long; HEPA Filter Module - 26" wide 80" high 28" long. Filtration - Primary/Secondary Filter - Dual-ply Dustlok polyester pad, Standard HEPA Filter - Wood Frame 99.97% Efficiency.3 micron. Power Requirement - 230V/60 Hz 3 phase 45 amp. Blower Cabinet - Aircraft grade aluminum, closed end rivet construction. All seams are silicone sealed before riveting. 4 4" casters for ease of movement. Filter Cabinets - Powder coated galvanized steel, closed end rivet construction. All seams are silicone sealed before riveting. 4 3" casters for ease of movement. Each filter cabinet is individually monitored for filter loading by a 0"-5" WC differential pressure gauge. Controls -Dual motor starter boxes with 32A disconnects w/lockout feature. Start and Stop pushbutton switches for each blower. Power On Indicator for each blower. Individual hour meters for each blower. Hose Connections - Outlet - 2-24" diameter rings. www.omnitecdesign.com 2125 196th Street SW, Suite 115, Lynnwood, WA 98036 phone 425-774-3257 fax 425-774-4983 1

OmniAire 18000 Air Filtration System IMPORTANT INSTRUCTIONS Read all the instructions before using this machine. CAUTION Connect ONLY to outlets that are properly grounded. Do not operate blower with damaged cord or plug or after it has been damaged in any manner.. Place cord out of the path of foot and equipment traffic to avoid trip hazard. To shut down the blower unit, turn both motors off and then unplug the cord. Do not locate blower cabinet outdoors, use only in DRY location. The motor and the protection circuit has arcing or sparking parts inside. Avoid operating in an environment with flammable liquids, gas, or paint. Do not use to exhaust combustible or explosive gases or operate in hazardous atmosphere. Do not insert or allow foreign objects to enter intake or outlet openings as this may cause electrical shock or fire and will damage the blower. DO NOT BLOCK OFF blower cabinet INTAKES or operate HEPA filter cabinets above 4.0 WC of vacuum to prevent possible damage to the blower cabinet, HEPA filters and the HEPA cabinets. All three blower intake connections to HEPA Cabinets must have hoses rated to operate at 10 WC vacuum or more. DO NOT operate the system without all 9 HEPA filters securely in place. Always unplug unit when not in use. Use the OA18000 only as prescribed, any other use may cause fire, shock or injury to persons. SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS - This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician. AVERTISSEMENT: WARNING "INSTRUCTIONS DE MISE À LA TERRE - Cet appareil doit être mis à la terre. En cas de défaillance ou de panne, la terre réduira le risque de choc électrique en fournissant un chemin de moindre résistance au courant électrique. Cet appareil est équipé d'un cordon comportant un conducteur de l 'appareil à la terre et une prise de mise à la terre. La prise de mise à la terre doit être branchée dans une prise électrique appropriée, installée et mise à la terre conformément aux codes et règlements locaux." "ATTENTION - Une connexion incorrecte du conducteur de l 'appareil à la terre peut entraîner un risque de choc électrique. Vérifier avec un électricien qualifié ou un représentant de service si vous êtes dans le doute si l'appareil est correctement mise à la terre. Ne pas modifier la fiche fournie avec l'appareil;. si elle n'entre pas dans la prise, faites installer une prise adéquate par un technicien qualifié." 2

LIST OF COMPONENTS OmniAire 18000... OA18000 2-22 Aerovent Vaneaxial Blowers 2 - Motor Starter Enclosures with Cutler-Hammer Contactor Cutler-Hammer Overload Relay Sprecher-Schuh Disconnect Switch 9 - HEPA filters 99.97% 0.3µ efficiency, 24 x24 x11.5 9 - Prefilters, MERV 8 poly pad, dual ply, 26 x26 x2 REPLACEMENT PARTS HEPA filter, 99.97% @ 0.3 micron, 24 x24 x11.5, metal or PB frame. Prefilter, Poly pad, dual density, treated with tactifier, MERV 8 rating. Suction hose, 18 dia. 25 ft long, wire reinforced, 0.015 thick PVC, rated for over 10 WC vacuum. Caster wheels for Blower unit. Caster wheels for HEPA Tower. Filter tabs. Vaneaxial fans For maintenance instructions and assistance with service and repair, refer to attached Aerovent IM-160 Brochure, IM-100 Brochure and AMCA Publication 410. 3

Introduction OmniAire 18000 consists of a Blower unit and three HEPA Towers. The HEPA Towers have to be connected to the Blower unit with three flexible hoses at all time for the system to operate properly. The Blower unit contains two 22 vaneaxial blowers with direct drive motors. Two motor starter enclosures are mounted on the front of the blower cabinet. One power cord connects the unit to 240 VAC/3 phase/50 amp power supply. The intake side of the Blower unit has 3-18 rings for flex hoses from HEPA Towers. The exhaust side of the machine has 2 24 rings which could be left open or ducted. Each HEPA Tower holds three HEPA filters and pre-filters. The HEPA filters are secured with 4 tabs to maintain tight seal to prevent any air bypass around HEPA filters. Each HEPA Tower cabinet has a vacuum gage, 0-5 WC, to measure pressure drop across the filters, representing loading of filters with dust. All three HEPA filters have to be installed and function properly for the system to operate. The function of the prefilter is to capture larger dust particles and to extend the operation of the HEPA. The dense, orange side of pre-filter has to face the HEPA. All three HEPA Towers have to be connected to Blower cabinet to assure proper operation of the whole system. The hoses have to be rated to operate at minimum of 10 WC of vacuum. 4

CONTACTOR OVERLOAD PROTECTION RELAY (SET @ 22 AMPS DISCONNECT SWITCH HOUR METER START SWITCH STOP SWITCH RUN LIGHT 5

Unpacking and Preparation Check the HEPA Towers for any distortion or damage. Before installing HEPA filters, check the silicone seal around the filter flange and the forward corners of the cabinets. Check the flex hose connection rings to have silicone seal where ring is attached to the cabinet. Use silicone seal on inside and outside the ring to prevent contaminated air seeping into filtered air. Remove the primary/ filters and check the HEPA filters for any visible damage or excessive loading with dust. Replace as needed. HEPA must be seated well against the internal housing flange and the bottom supports. The tabs must tight to compress the HEPA gasket to prevent any air bypass. Install prefilters with orange side facing HEPA. The prefilters have to be replaced frequently. Good indication is when dust starts to show on the downstream side (orange side). NOTE: If any one of the HEPA filters is leaking or has a bypass, whole system will fail required DOP efficiency test. The Blower cabinet with motor controls has to be inspected for any visible damage. The intake plenum operates under vacuum and has to be well sealed. Check silicone seal around 18 intake rings where they are welded to the cabinet. Silicone seal should be on inside and outside the ring. Inspect flex hoses for any tears and breaks. The hoses must be secured to the rings on HEPA towers and the Blower unit with clamps to prevent any air leaks. Use double clamps. 6

Operation: For asbestos and dust abatement, machine must be operated with all nine HEPA filters in place. Also, it is recommended to use the prefilters and replace them frequently to extend the life of the HEPA. All HEPA Towers must be securely connected to the Blower unit. To start the machine: With flex hoses connected, move the HEPA Towers to desired positions and block the wheels. The hoses should be running straight to minimize airflow resistance. Plug the power cord in 240Vac/60 Hz /3 phase, 50 amp. grounded power source. Turn the first blower ON and after 10 seconds, turn the second blower ON. Each blower has its separate motor starter and overload protection system. Check the vacuum reading on all HEPA towers. Note the vacuum reading while all filters are clean. With all clean filters the flow should be evenly distributed. The filters will load with dust and when the gauge reaches about 3.5 WC, change the prefilters. The loading of filters may not be evenly distributed as some HEPA Towers may be in an area with more dust. When the vacuum gauge shows 3.5 to 4 even after changing the prefilters, the HEPA filters may need to be replaced. Operating with vacuum above 4 WC may cause HEPA filters releasing some fine particulates and even structural breakdown. DO NOT OPERATE THE HEPA TOWERS ABOVE 4.0 WC. Note: Primary filters can be changed while machine is running. The system can run on a single blower but the all the HEPA Towers must be connected. As the filters fill with dust, the efficiency of the filters are maintained, but the air flow will decrease and the vacuum reading will increase. Change the primary filters frequently to protect the HEPA and to get more air flow. When vacuum reaches about 3.5 WC with a clean prefilter, the HEPA filter will have to be replaced to increase the air flow. Warning: The HEPA filters and the cabinets are designed to operate at maximum of 4.5 WC of vacuum. When filters get plugged up with dust, the blowers are capable of generating vacuum of 9 WC and may destroy the HEPA and potentially the integrity of the HEPA cabinets. The vacuum reading on individual HEPA towers must be monitored and not to exceed 4.0 WC. 7

Trouble shooting: Unit does not start when plugged into power source. Check the power source for correct voltage of 240Vac/60 Hz and 50 Amps capacity. Check the power cord and the plug for any damage. Machine starts but shuts down quickly Problem: The power supply is less then 50 amps. Check the power source. A single blower will run even on 18 amps but may trip when filters are loaded with dust. Problem: Overload protection setting is set low. Unplug the power cord. Open the motor starter and check the overload setting. The dial (yellow) knob should point to 22 amps. Push red Reset button to reset the overload protection. Maintenance: The OA18000 is easy to maintain. The HEPA Towers are epoxy powder coated and can be easily cleaned. When HEPA filters are removed, inspect the silicone seal inside the unit plenum and around the filter flange. Lubrication. The vaneaxial blowers require periodic lubrication. Grease fittings are easily accessible by removing the exhaust rings door. Check the Aerovent manual for the maintenance schedule and the type of lubricants. Change primary/secondary filter when: Visual inspection - white filter side surface is loaded with dust and it starts to show on orange side. Pressure gauge reading increased by 0.3 WC since clean filter was changed. Change HEPA filter when: Holes or cracks are found in HEPA filter media. Air flow from machine is not sufficient. Use pressure gauge reading (at HIGH speed) to check the WC reading. Range is 1.8 to 3.5 WC for flow of 100% to 20% capacity. Pressure gauge reads 3.5 WC even with clean primary/secondary filter. Machine becomes noisier and hardly any air comes out. For additional assistance contact: Omnitec Design, Inc. - 2125 196th St. SW, Suite 115, Lynnwood, WA 98036-425-774-3257 8