76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Rated pressure range (Note) to. kpa to. MPa. to. kpa Model No. Pressure port Applicable fluid -A -A -A -A -A -A -A -A7 -A7 -A7 Note: The rated pressure range indicates the range for full product performance. Controllers Controller M male thread R /8 male thread / M female thread NPT /8 male thread / -UNF female thread -UNF male thread M male thread R /8 male thread / M female thread NPT /8 male thread / -UNF female thread M male thread R /8 male thread / M female thread NPT /8 male thread / -UNF female thread An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Appearance Rated pressure range (Note) Model No. Output Vacuum pressure: to. kpa Positive pressure: to. MPa Compound pressure:. to. kpa 6-core cable with connector Only the connector is attached with the controller. ( ) DP-C DP-C-P Non-corrosive gas NPN open-collector transistor PNP open-collector transistor Note: The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. Intermediate cables An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Designation Appearance Model No. Description -CC Length: m 6.6 ft Standard -CC Length: m 9.84 ft 4-core cable with connector at both ends -CC Length: m 6.4 ft -CC-R Length: m 6.6 ft Flexible -CC-R Length: m 9.84 ft 4-core flexible cable with connector at both ends -CC-R Length: m 6.4 ft Accessory MS-DP- (Panel mounting bracket)
77 Designation Model No. Description Connector CN-66 Set of housings and 6 connector pins 6-core cable with connector CN-66-C CN-66-C Length: m 6.6 ft Length: m 6.4 ft. mm 6-core cabtyre cable with connector Cable outer diameter: ø4.8 mm ø.89 in DIN rail mounting bracket Controller mounting bracket MS-DP- MS-DP- MS-DP-4 For installation to mm.78 in width DIN rail Vertical mounting bracket Horizontal mounting bracket Horizontal multiple panel mounting bracket MS-DP- Enables the sensors to be attached to each other laterally and mounted on the panel. Connector CN-66 Connector pin 6-core cable with connector CN-66-C CN-66-C DIN rail mounting bracket MS-DP- Housing Controller mounting bracket MS-DP- MS-DP-4 Label space Designed with a 9 mm.4 in label space to enable the labeling of the sensors with a label printer (9 mm.4 in width) for sensor number and application data. Horizontal multiple panel mounting bracket MS-DP- 4-panel fixing screws (Accesory) MS-DP- * The above illustration shows two units connected in sequence.
78 SPECIFICATIS Item Type of pressure Type Vacuum pressure Positive pressure Compound pressure kpa type MPa type ± kpa type Model No. -A -A -A -A -A -A -A -A7 -A7 -A7 Gauge pressure Rated pressure range (Note ) to. kpa to. MPa. to. kpa Pressure withstandability kpa. MPa kpa Applicable fluid Non-corrosive gas Supply voltage to 4 V DC + % Ripple P-P % or less Current consumption ma or less (operation indicator lights off) / 7 ma or less (operation indicator lights on) Analog voltage output Environmental resistance Pollution degree Protection Output voltage: to V (over rated pressure range) Zero point: within V ± % F.S. (vacuum / positive pressure type) within V ± % F.S. (compound pressure type) Span: within 4 V ±. % F.S. Linearity: within ± % F.S. Output impedance: kω approx. Output voltage (V) (Industrial environment) IP (IEC) Pressure High pressure positive / compound ( pressure type ) High vacuum (vacuum pressure type) Ambient temperature to + C + to + F (No dew condensation), Storage: to +6 C +4 to + F Ambient humidity EMC Voltage withstandability Insulation resistance Vibration resistance Shock resistance Operation indicator Temperature characteristics Voltage characteristics Pressure port Material Connecting method to 8 % RH, Storage: to 8 % RH EN 6-6-, EN6-6-4, V AC for one min. between all supply terminals connected together and enclosure MΩ, or more, with V DC megger between all supply terminals connected together and enclosure to Hz frequency, mm.8 in amplitude, in X, Y and Z directions for two hours each, m/s acceleration ( G approx.) in X, Y and Z directions for three times each Orange LED [lights up when the Output is (only in case of connection to the DP series pressure controller)] Over ambient temperature range + to + C + to +4 F: within ± % F.S. of detected pressure at + C +77 F Over ambient temperature range to + C + to + F: within ± % F.S. of detected pressure at + C +77 F Within ±. % F.S. for ± % fluctuation of the supply voltage -A : M male thread (for installing gasket), -A : R /8 male thread / M female thread -A : NPT /8 male thread / -UNF female thread, -A: -UNF male thread (for installing gasket) Enclosure: PBT, Pressure port: Brass (nickel plated) [however, stainless steel (SUS) in case of -A ] Connector Cable. mm 4-core oil resistant cabtyre cable with connector, mm.97 in long Cable extension Net weight Accessories Extension up to total m.88 ft is possible with. mm, or more, cable. -A / -A: 6 g approx., -A / -A : g approx. Gasket (-A, -A only) Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +68 F. ) The rated pressure range indicates the range for full product performance. ) The sensor head can be used independently.
79 SPECIFICATIS Controller Type NPN output type PNP output type Item Model No. DP-C DP-C-P Applicable sensor head Rated pressure range (Note ) Set pressure range (Note ) -A, -A, -A7, -A, -A, -A7, -A, -A, -A7, -A Vacuum pressure: to. kpa, Positive pressure: to. MPa, Compound pressure:. to. kpa Vacuum pressure:. to. kpa (. to. kgf/cm, 4.7 to 4.7 psi,. to. bar, 76 to 76 mmhg, 9.9 to 9.9 inhg) Positive pressure:. to. MPa (.7 to.7 kgf/cm,. to. psi,. to. bar) Compound pressure: 99.9 to 99.9 kpa (.8 to.8 kgf/cm, 8.99 to 8.99 psi,.999 to.999 bar, 499 to 499 mmhg, 9 to 9 inhg) Supply voltage / Current consumption to 4 V DC + % Ripple P-P % or less / 6 ma or less (not including sensor head) Sensor supply voltage Same as supply voltage outputs ( Output, ) Inputs Utilization category Output operation Output modes Hysteresis Repeatability Response time Short-circuit protection input External input Auto-reference / Remote zero-adjustment function Analog voltage output Display Displayable pressure range NPN open-collector transistor ( outputs) Maximum sink current: ma Applied voltage: V DC or less (between comparative output and V) Residual voltage: V or less (at ma sink current).4 V or less (at 6 ma sink current) PNP open-collector transistor ( outputs) Maximum source current: ma Applied voltage: Same as supply voltage (between comparative output and +V) Residual voltage: V or less (at ma source current) DC- or DC- NO / NC, selectable by key operation Equipped with 4 types of modes: hysteresis mode, window comparator mode, leak test mode, forced output mode (selectable by key operation) digit (however, variable in hysteresis mode, variable for Output only when using leak test mode) With vacuum / positive pressure type sensor head: within ±. % F.S. ± digit (± digits) With compound pressure type sensor head: within ±. % F.S. ± digits (±6 digits) ms, 6 ms, 8 ms, ms or less, selectable by key operation (however, set response time is + ms when auto-reference / remote zero-adjustment input is applied) Incorporated Input voltage range: to V DC (over rated pressure range) Input condition: NPN non-contact input [operates in Low (fall) state] Signal condition: High... to V, or open Low...4 V or less Low level input time... ms or more Output voltage: to V DC (over rated pressure range) Zero point: within V ±. % F.S. (vacuum / positive pressure type) within V ±. % F.S. (compound pressure type) Span: within 4 V ±4 % F.S. Linearity: within ± % F.S. Output impedance: kω approx. Input condition: PNP non-contact input [operates in High (rise) state] Signal condition: High... to V Low...4 V or less, or open High level input time... ms or more Output voltage (V) Pressure High pressure positive / compound ( pressure type ) High vacuum (vacuum pressure type) / digit LCD display (with red and green backlight) (Display refresh rate: 6 ms, ms or,4 ms selectable by key operation) Vacuum pressure:. to. kpa (. to. kgf/cm,.74 to 4.7 psi,. to. bar, 8 to 76 mmhg,. to 9.9 inhg) Positive pressure:. to. MPa (. to.7 kgf/cm, 7. to. psi,. to. bar) Compound pressure:. to. kpa (. to.7 kgf/cm, 4.7 to. psi,. to. bar, 76 to 787 mmhg, 9.9 to. inhg) LCD segment is red when the comparative output is, and green when it is (output is selected via supplementary settings) Bar display in steps of 4 % F.S. approx. Orange LED (lights up when the Output is ), Green LED (lights up when the Output is ) (Industrial environment) IP (IEC) Operation display Analog bar display Operation indicator Pollution degree Protection Ambient temperature to + C + to + F (No dew condensation), Storage: to +6 C +4 to + F Ambient humidity to 8 % RH, Storage: to 8 % RH EMC EN 6-6-, EN 6-6-4 Voltage withstandability, V AC for one min. between all supply terminals connected together and enclosure Insulation resistance MΩ, or more, with V DC megger between all supply terminals connected together and enclosure Vibration resistance to Hz frequency,.7 mm. in amplitude, in X, Y and Z directions for two hours each Shock resistance m/s acceleration ( G approx.) in X, Y and Z directions for three times each Temperature characteristics Over ambient temperature range to + C + to + F: within ±. % F.S. of pressure at + C +77 F (not including sensor head) Material Front case: ABS, LCD display section: PET, Rear case: PBT Connecting method Connector Conductor cross-section area.6 to. mm (AWG# to #) (Note ) Lead wire diameter ø. to ø.8 mm ø.47 to ø.7 in Wire material Tin plated, soft, twisted copper wire Cable length Total length up to m 8.84 ft (less than m.88 ft when conforming to CE marking) is possible with. mm, or more, cable. Weight Net weight: g approx. Accessories Panel mounting bracket (MS-DP-): set, Connector: set (Housing: pc., Connector pin: 6 pcs.), Pressure unit label: set., Connector cap: pc. Environmental resistance Suitable cable Notes: ) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +68 F. ) The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. ) If the wiring is longer than m 6.4 ft, use a cable with a diameter of. mm or more.
7 I/O CIRCUIT DIAGRAMS DP-C NPN output type I/O circuit diagram main circuit D kω ZD4 +V Type setting / indicator signal 4 4 Analog voltage input V Controller main circuit Tr ZD Tr Color code of cable with connector (Brown) +V (Pink) External input (Note) 6 (Gray) Analog voltage output Load (Black) Load + Output 4 (White) ma max. Output ma max. (Blue) V internal circuit Controller internal circuit Users circuit Intermediate cable Note: Select and use the auto-reference function and remote zero-adjustment function. Terminal arrangement diagram Connector for sensor head connection 4 4 6 Connector for power supply / D kω Symbols D, D: Reverse supply polarity protection diode ZD to ZD4: Surge absorption zener diode Tr, Tr: NPN output transistor DP-C-P I/O circuit diagram ZD ZD Connector for power supply / +V Analog voltage output V 4 Output Output 6 External input (Auto-reference / Remote zero-adjustment function) to 4 V DC + % For independent use of Main circuit D kω ZD Color code (Brown) +V (White) Not connected (Note) (Black) Analog + voltage output ( to V) (Blue) V to 4 V DC + % Users circuit internal circuit Notes: ) In case the sensor head is used independently, insulate the white lead wire (terminal No.4) and keep it open. ) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at kω or more. Symbols D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Connector for sensor head connection +V Analog voltage output V 4 Not connected PNP output type For independent use of main circuit D kω ZD4 +V Type setting / indicator signal Analog voltage input V Controller main circuit Z D Tr Tr Color code of cable with connector (Brown) +V D (Pink) External input (Note) (Black) Output ma max. + Z D ma max. (White) Load kω Output (Gray) Analog Load voltage output Z D (Blue) V to 4 V DC + % Main circuit D kω ZD Color code (Brown) +V (White) Not connected (Note) (Black) Analog + voltage output ( to V) (Blue) V to 4 V DC + % internal circuit Intermediate cable Controller internal circuit Symbols D, D: Reverse supply polarity protection diode ZD to ZD4: Surge absorption zener diode Tr, Tr: PNP output transistor Terminal arrangement diagram Users circuit Note: Select and use the auto-reference function and remote zero-adjustment function. Connector for power supply / Users circuit internal circuit Notes: ) In case the sensor head is used independently, insulate the white lead wire (terminal No.4) and keep it open. ) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at kω or more. Symbols D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Connector for sensor head connection Connector for sensor head connection 4 4 6 Connector for power supply / +V Analog voltage output V 4 Output Output 6 External input (Auto-reference / Remote zero-adjustment function) +V Analog voltage output V 4 Not connected
7 PRECAUTIS FOR PROPER Refer to General precautions. Operation Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The series is designed for use with noncorrosive gas. It cannot be used with liquid or corrosive gas. If setting is impossible even with pressing the MODE key, verify whether the key-protect function is enabled. Please note that pressing down on the MODE key for an extended moment will enable the key-protect function as soon as the key is released. If using the window comparator mode, set the pressure values so that there is a difference of digits, or more, between Set Value (P-) and Set Value (P-) and between Set Value (P-) and Set Value 4 (P-4). The output does not operate if the interval is between and digits. Functional description Description Function Displays measured pressure, settings, error / digit LCD messages and key-protect status. display Its lighting up can be set as Red when / with red and Green when with respect to either green backlight Output or Output, according to the backlight relation selection during the supplementary setting mode. Output operation indicator (Orange) Lights up when Output is. Output operation indicator (Green) Lights up when Output is. In the initial setting mode and supplementary setting mode, pressing the key changes the setting item. 4 In the pressure value setting mode, Increment pressing the key changes the set (UP) key value. In the sensing mode, pressing the key continuously for 4 sec., or more, displays the peak hold value. Decrement (DOWN) key 6 MODE key 7 8 DP OUT MODE Connector for power supply / Connector for sensor head connection UP OUT DOWN 6 4 8 7 In the initial setting mode and supplementary setting mode, pressing the key changes the set conditions. In the pressure value setting mode, pressing the key changes the set value. In the sensing mode, pressing the key continuously for 4 sec., or more, displays the bottom hold value. In the sensing mode, if both keys are simultaneously pressed continuously, zero-point adjustment is done. In the pressure value setting mode, pressing the key changes the setting item. In the sensing mode, pressing the key continuously for 4 sec., or more, can set / cancel the key-protect. In the sensing mode, pressing both UP key and MODE key simultaneously changes the mode to the initial setting mode. Whereas, pressing both DOWN key and MODE key simultaneously changes the mode to the supplementary setting mode. It is the connector for connection of power supply / I-O cable. It is the connector for connection of sensor head. Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this controller, connect the frame ground (F.G.) terminal of the equipment to an actual ground. If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. In order to reduce noise, make the wiring as short as possible. Take care that wrong wiring will damage the sensor. Conditions in use for CE conformity The controller is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 6-6- and the following condition must be met to conform to that standard. Conditions The controller should be connected less than m.88 ft from the power supply. The signal line to connect with the controller should be less than m 98.4 ft. Setting The set conditions are written and stored into an EEPROM. However, note that the EEPROM has a life span and its guaranteed life is, write operation cycles. Further, since the Set Value P-A is not stored in the EEPROM, they are not included in the number of write operation cycles.
7 PRECAUTIS FOR PROPER Refer to General precautions. Auto-reference function Auto-reference function corrects Set Value P- and Set Value P-4 of Output by taking the pressure measured at the time of auto-reference input as the reference pressure. Please select the auto-reference function at the supplementary setting mode when using this function. <Before auto-reference input> Output Atmospheric pressure P- P-4 Pressure When there is no auto-reference input, the atmospheric pressure is taken as the reference pressure for Set Value P- and Set Value P-4. <After auto-reference input> Auto-reference input Output Pressure change Atmospheric pressure P-A P- P-4 Pressure P- = P- + P-A P-4 = P-4 + P-A At the time of auto-reference input, the pressure value detected at that instant is temporarily recorded as Set Value P-A and becomes the reference pressure. With Set Value P-A as the reference pressure, Set Value P- and Set Value P-4 are automatically corrected to Set Value P- + Set Value P-A and Set Value P-4 + Set Value P-A, respectively. Settable range and set pressure range after correction The settable range of Set Value P- and Set Value P-4 is wider than the rated pressure range to cater to the auto-reference function. At the time of auto-reference input, if the corrected set value exceeds the set pressure range, the set value is automatically corrected to be within the set pressure range. Hence, please see that the set pressure range is not exceeded. Operation chart <Normal operation (comparative outputs set to NO)> Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) 6 7 8 9 6 7 8 9 P- P- P- P-4 <With auto-reference input (comparative outputs set to NO)> Auto-reference input: kpa Output mode: Hysteresis mode Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) 6 7 8 9 6 7 8 9 P- P- P-A P- P-4 8 9 Note: As in the case of the hysteresis mode, Set Value P- and Set Value P-4 are shifted also in case the output is set to the window comparator mode or the leak test mode. Maintain the pressure at a constant level for at least ms after the auto-reference input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use Output at least set response time + ms after the auto-reference input is made Low (High in case of PNP output type). At the time of auto-reference input, is displayed on the / digit display for sec. approx. The auto-reference input value (Set Value P-A) becomes zero when the power supply is switched off and then on again. Although it is not possible to display the corrected Set Value P- and Set Value P-4, it is possible to display the auto-reference input value (Set Value P-A).
7 PRECAUTIS FOR PROPER Remote zero-adjustment function The remote zero-adjustment function forcibly displays the pressure value at the time of application of an external input signal to zero. Please select the remote zeroadjustment function at the supplementary setting mode when using this function. At the time of remote zero-adjustment input, the set values are not corrected. When using the remote zeroadjustment function, make sure that the pressure and the set values do not exceed the rated pressure range. Operation chart <Normal operation (comparative outputs set to NO)> Output Output Set value (kpa) Applied pressure (kpa) 6 7 8 9 Display value (kpa) 6 7 8 9 P- P- P- P-4 <With remote zero-adjustment input (comparative outputs set to NO)> Remote zero-adjustment input: kpa Output mode: Hysteresis mode Output Output Set value (kpa) Applied pressure (kpa) 6 7 8 9 Display value (kpa) P- P- P- P-4 Note: As in the case of the hysteresis mode, the displayed values and the / points of the output are shifted also in case the output mode is set to the window comparator mode. Remote zero-adjustment input: kpa Output mode: Leak test mode Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) 6 7 8 9 P- P- P- P-4 Note: In the leak test mode, the zero-adjustment function is applied only to Output. Output operates with the atmospheric pressure as the reference. Maintain the pressure at a constant level for at least ms after the remote zero-adjustment input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use the comparative outputs at least set response time + ms after the remote zero-adjustment input is made Low (High in case of PNP output type). At the time of remote zero-adjustment input, is displayed on the / digit display for sec. approx. If the power supply is switched off and then on again, the remote zeroadjustment input value (set Value P-A) is cleared and the sensor returns to normal operation with atmospheric pressure as the reference. Forced output mode Key-protect function Refer to General precautions. In the initial setting mode, if the output mode is set to the forced output mode ( ), the comparative outputs are forcibly maintained at level in the sensing mode, irrespective of Set Values P- to P-4. Further, if the keys are operated as per the procedure given below, the comparative outputs can be forcibly switched either or without applying pressure at the pressure port. This is convenient for an operation check of the comparative outputs or for an inspection before commencing work. Peak hold & bottom hold functions Peak hold and bottom hold functions enable the display of the peak value (maximum pressure value) and the bottom value (minimum pressure value) of the varying measured pressure. These functions are convenient for finding the pressure variation range or determining the reference for pressure settings. Please note that the peak value and the bottom value data is erased when it is no longer displayed. s Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (DP: sec. approx., : ms approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. Key-protect is a function which prevents any unintentional change in the conditions which have been entered in each setting mode by making the sensor not to respond to the key operations. Since the key-protect information is stored in an EEPROM, it is not erased even if the power supply is switched off. Please take care to remember if the key-protect function has been set. When the keys are to be operated, make sure that keyprotect is released.
74 PRECAUTIS FOR PROPER Piping When connecting a commercial coupling to the pressure port, hold the hexagonal section of the pressure port with a mm.4 in (-A, -A : mm.47 in) spanner, and make sure that the tightening torque is N m (male thread type of -A, -A : N m) or less. If excessive tightening torque is applied, the M male thread of the commercial coupling or the pressure port will get damaged. Connecting To connect the sensor head to the controller, the optional intermediate cable (-CC ) must be used. Take care that stress is not directly applied to the cable joint or the connector. If the sensor head is to be mounted on a movable part, make sure to use a flexible intermediate cable. When connecting the intermediate cable to the controller, make sure to fit the connector cap, supplied as an accessory with the controller, by sliding it as shown in the figure below. If the connector cap is not fitted, there is a danger of the intermediate cable getting disconnected from the sensor. Mounting Refer to General precautions. Install the enclosed panel mounting bracket (MS-DP-) as shown in the figure below. The tightening torque should be. N m or less. Further, tighten both the right and the left screw gradually and equally, so that the panel mounting bracket does not tilt. M (length mm.9 in) panel fixing screw (Accessory) Panel mounting bracket (MS-DP-) (Accessory) Independent use of pressure sensor head In case of using the pressure sensor head independently, cutoff the connector attached to the cable of the pressure sensor head, and prepare the cable end with a stripper, etc. If the cable is to be extended, use the optional intermediate cable (-CC ). Further, if the extension is done without using the optional intermediate cable, use a.mm, or more, cable and the total cable length should be m.8 ft or less. Connector cap DIMENSIS (Unit: mm in) When extending the cable, the voltage will be decreased depending on the resistance of cable used. Make sure to insulate the white wire ( 4), and keep it open. When the pressure sensor head is used independently, devices connected to the analog voltage output must have an input impedance set at kω or more. When the pressure sensor head is used independently, the operation indicator (orange) does not light up. The CAD data in the dimensions can be downloaded from our website. DP-C DP-C-P Controller / digit LCD display (Green and Red) Output operation indicator (Orange) Mode selection key DP OUT MODE.7 Decrement key UP OUT DOWN Increment key Output operation indicator (Green) 7.76 (6) (.47) 9.4 Connector cap Connector for sensor head connection 6..6 6..47 Connector for power supply /
7 DIMENSIS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. -A -A..49..4 9..74.4 8.. 6..6.97 Pressure port.97 (8.) (.78) -A : M male thread -A: -UNF male thread ø.7 ø.46 cable () (.) () (.94) -A -A..49.4 8....6 6..6 9..74 ().97 (.97) Pressure port (8.) (.78) () (.) -A : R /8 male thead / M female thead -A : NPT /8 male thead / -UNF female thread ø.7 ø.46 cable Operation indicator (Orange) SMR-4V-N manufactured by J.S.T. Mfg. Co.,Ltd. Operation indicator (Orange) SMR-4V-N manufactured by J.S.T. Mfg. Co.,Ltd. MS-DP- Panel mounting bracket (Accessory for the controller) Assembly dimensions 6. 49.99.7 Panel (Note) Panel cut-out dimensions +. 7.669 +. 6.6 (.).9 (.848).47 DP OUT MODE Panel fixing screw Material: POM UP OUT DOWN 7.76 6.47 X X +. +. +. 7.47 +. +. 7.47 +. X when n unit is installed X = (n ) + 7 mm X = (n ) +.669 in Note: The panel thickness should be to 6 mm.94 to.6 in. Two M (length mm 9 in) screws for fitting are attached. MS-DP- Assembly dimensions Vertical mounting.9 DP OUT MODE..7 UP OUT DOWN.79 - ø4. ø.77 mounting holes.8 Variable range () (.94) 4.69 9.4 6.7.6.47 Suitable for mm.78 in width DIN rail Horizontal mounting Variable range 4.69 () (.94) - ø4. ø.77 mounting holes.7 DIN rail mounting bracket (Optional) 9.4 6.6.9..7.47.8 Suitable for mm.78 in width DIN rail DP OUT MODE UP OUT DOWN.78.9.4
76 DIMENSIS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. -CC Intermediate cable (Optional) CN-66 Connector (Optional) CN-66-C CN-66-C Cable with connector (Optional) Housing (9.) (.74) (7.) (.68) (.) (.49) (7.) (.87) (6) ø.7 ø.46 cable (.6) DF-4DS-C manufactured by Hirose Electric Co.,Ltd. (6.9) (.7) Connector pin (.9) (.7) (.) (.8) (.7) (.46) Note: The heat-shrink tube for the standard cable is black, and the heat-shrink tube for the flexible cable is gray. L (6.) (.6) Mating Connector Connector pin: BXA-T-P.6 manufactured by J.S.T. Mfg. Co., Ltd. Housing: XAP-6V- manufactured by J.S.T. Mfg. Co., Ltd. Crimping tool YC-69R manufactured by J.S.T. Mfg. Co., Ltd. (.) (.4) SMP-4V-NC manufactured by J.S.T Mfg. Co.,Ltd. (.7) (.68) (.8) (.8) (9.) (.74) Model No. -CC(-R) -CC(-R) -CC(-R), 78.7 (CN-66-C:, 96.8) XAP-6V- manufactured by J.S.T. Mfg. Co.,Ltd. Length L m 6.6 ft m 9.84 ft m 6.4 ft () (.969) ø4.8 ø.89 cable MS-DP- Controller mounting bracket (Optional) MS-DP-4 Controller mounting bracket (Optional) - ø4. ø.77 mounting holes 9.7.778 7.44.7 7.44 7.47.47 4.94 7 4.669.64 t t.79 Material: Cold rolled carbon steel (SPCC)(Uni-chrome plated) Note: Use together with panel mounting bracket (MS-DP-) included with controller. MS-DP- Assembly dimensions.7 7.76 panel 4.64.8.97 6..47 6.9 7.47 t t.79.8 6.6 R6 R.6 7 8.669. 6.6 ø4. ø.77 mounting holes 4..77 Material: Cold rolled carbon steel (SPCC)(Uni-chrome plated) Note: Use together with panel mounting bracket (MS-DP-) included with controller. Panel cut-out dimensions.7 or more 7 +..47 +. +. 7.669 +. Length L Horizontal multiple panel mounting bracket (Optional) X X +. +. 7 +..669 +. X when n unit is installed X = (n ) + 7 mm X =.7 (n ) +.47 in (n = or less) When installed laterally in sequence...9 8..4 When installing individually Note: The panel thickness should be to 6 mm.9 to.6 in. Applicable panel thickness dimensions t = to 6 mm t =.9 to.6 in Panel fixing screw