Tag: RTU-1 Comments: Unit Information Cooling Performance Heating Performance Model: Horizon (B/G) Unit Length: 208 in Size: G120 Unit Width: 74 in Quantity: 1 Unit Height: 67 in Supply Airflow: 4,000 CM Elevation: 0 ft Outside Airflow: 1,800 CM Ambient Air 95 Minimum Airflow: 1,475 CM Weight Operating: Gross Total Capacity: 126.8 MBh Evaporator ace Area: 10 sq ft Gross Sensible Capacity: 88.1 MBh Evaporator Rows / PI: 4 / 12 Net Total Capacity: 118.4 MBh Condenser ace Area: 25 sq ft Net Sensible Capacity: 79.7 MBh Condenser Rows / PI : 2 / 14 Entering Air DB / WB (Coil): 75.5 / 65.3 Air Velocity: 400 fpm Leaving Air DB / WB (Coil): 55.6 / 54.9 Coil Air PD: 0.37 in H2O Leaving Air DB / WB (Reheat): / EER: 9.7 Note: Leaving Air DB / WB (Unit): 57.9 / 55.8 Watts: 14902 MRE: 2.36 lb/kwh MRC: 35.21 lb/h Heat Type: Gas urnace Entering Air 58.3 Input Capacity 200 MBh Leaving Air 95.3 Output Capacity: 160 MBh Coil Air PD: 0.36 in H2O 4336 lb* Weight does not include CURB weight. See CURB submittal for actual Refrigerant Charge Circuit 1: Circuit 2: 15.6 lbs 15.6 lbs Energy Recovery Wheel ERC-4136C Summer Conditions Ventilation Supply Outside ** TAB Outside airflow through OA Intake to this value Winter Conditions Ventilation Supply Outside Airflow: 1,800 CM Airflow: 1,950 CM** Airflow: 1,800 CM Airflow: 1,950 78.8 88.0 46.4 0.0 66.9 71.0 40.8-1.0 PD: 0.41 in H20 PD: 0.41 in H20 CM** Return Exhaust Return Exhaust Airflow: 1,500 CM Airflow: 1,650 CM Airflow: 1,500 CM 75.0 65.0 84.9 69.5 68.0 55.0 ESP: 0.75 in H20 ERV PD: 0.35 in H20 ESP: 0.75 in H20 Airflow: ERV PD: 1,650 CM 15.6 17.1 0.35 in H20 Total Capaciy: 25.67 MBH Total Capaciy: 124.10 MBH Sensible Capacity: 19.44 MBH Eff. 0.83 Sensible Capacity: 97.68 MBH Eff: 0.84 Latent Capacity: 6.23 MBH Eff: 0.76 Latent Capacity: 26.42 MBH Eff: 0.77 1 of 4 12/5/2017 2:24:40 PM
Tag: RTU-1 Supply an GKHM_450x2 Supply Pressure Drop Summary Supply an Conditions External Static Pressure: 1.00 in H2O an Motor BHP: 3.29 BHP Internal Pressure Drop: 1.50 in H2O Operating RPM: 1581 RPM Total Static Pressure: 2.50 in H2O Minimum RPM: 829 RPM 2 of 4 12/5/2017 2:24:40 PM
Tag: RTU-1 Exhaust an GKHM_450 Exhaust Pressure Drop Summary Exhaust an Conditions Return External Static Pressure: 0.75 in H2O an Motor BHP: 0.69 BHP Exhaust Internal Pressure Drop: 0.55 in H2O Operating RPM: 1164 RPM Total Exhaust Static Pressure 1.30 in H2O Unit Electrical Data Unit Voltage-Ph-Hz: 208-3-60 Min Circuit Ampacity - MCA: 96.5 Amps Unit Amps - LA: 87.17999 Amps Maximum use Size - MS: 125 Amps Electrical Summary Component an Service Qty HP (ea.) LA (ea.) RLA (ea.) LRA (ea.) ERV/HRV 1 0.17 0.88 Exhaust 1 4 7.6 Scroll 1 15.6 110 Variable Speed Scroll 1 37.1 58 Supply 2 4 7.6 Condenser 2 1 4.2 Controls 1 2.4 Standard Radiated Sound Power Level (dba) 63 125 250 500 1000 2000 4000 8000 Total dba 53.1 77.8 87.1 90 89.1 85.7 79.4 71.4 94.6 Sound power levels are listed for informational purposes only and are not guaranteed. 3 of 4 12/5/2017 2:24:40 PM
Tag: RTU-1 Notes 1. See option list schedule for selected options. 2. See catalog for dimension and weight 3. or single point power connection, Unit Electrical amps include the greater of compressor or electrical heat amps 4. or dual point power connections (electrical heat), Unit Electrical Data does not include electric heat power requirements 4 of 4 12/5/2017 2:24:40 PM
Tag: RTU-2 Comments: Unit Information Cooling Performance Heating Performance Model: Horizon (B/G) Unit Length: 208 in Size: G120 Unit Width: 74 in Quantity: 1 Unit Height: 67 in Supply Airflow: 3,500 CM Elevation: 0 ft Outside Airflow: 1,200 CM Ambient Air 95 Minimum Airflow: 1,106 CM Weight Operating: Gross Total Capacity: 124.7 MBh Evaporator ace Area: 10 sq ft Gross Sensible Capacity: 82.7 MBh Evaporator Rows / PI: 4 / 12 Net Total Capacity: 117.7 MBh Condenser ace Area: 25 sq ft Net Sensible Capacity: 75.7 MBh Condenser Rows / PI : 2 / 14 Entering Air DB / WB (Coil): 75.4 / 65.2 Air Velocity: 350 fpm Leaving Air DB / WB (Coil): 54.0 / 53.4 Coil Air PD: 0.31 in H2O Leaving Air DB / WB (Reheat): / EER: 9.4 Note: Leaving Air DB / WB (Unit): 56.2 / 54.3 Watts: 14483 MRE: 2.59 lb/kwh MRC: 37.44 lb/h Heat Type: Gas urnace Entering Air 61.5 Input Capacity 150 MBh Leaving Air 93.2 Output Capacity: 120 MBh Coil Air PD: 0.54 in H2O 4232 lb* Weight does not include CURB weight. See CURB submittal for actual Refrigerant Charge Circuit 1: Circuit 2: 15.6 lbs 15.6 lbs Energy Recovery Wheel ERC-4136C Summer Conditions Ventilation Supply Outside ** TAB Outside airflow through OA Intake to this value Winter Conditions Ventilation Supply Outside Airflow: 1,200 CM Airflow: 1,405 CM** Airflow: 1,200 CM Airflow: 1,405 78.3 88.0 49.1 0.0 66.7 71.0 42.6-1.0 PD: 0.29 in H20 PD: 0.29 in H20 CM** Return Exhaust Return Exhaust Airflow: 1,000 CM Airflow: 1,205 CM Airflow: 1,000 CM 75.0 65.0 86.3 70.1 68.0 55.0 ESP: 1.50 in H20 ERV PD: 0.26 in H20 ESP: 1.50 in H20 Airflow: ERV PD: 1,205 CM 8.4 9.9 0.26 in H20 Total Capaciy: 18.00 MBH Total Capaciy: 87.03 MBH Sensible Capacity: 14.73 MBH Eff. 0.87 Sensible Capacity: 74.46 MBH Eff: 0.88 Latent Capacity: 3.26 MBH Eff: 0.8 Latent Capacity: 12.57 MBH Eff: 0.81 1 of 4 12/5/2017 2:25:50 PM
Tag: RTU-2 Supply an GKHM_450 Supply Pressure Drop Summary Supply an Conditions External Static Pressure: 1.00 in H2O an Motor BHP: 2.75 BHP Internal Pressure Drop: 1.42 in H2O Operating RPM: 1821 RPM Total Static Pressure: 2.42 in H2O Minimum RPM: 1021 RPM 2 of 4 12/5/2017 2:25:50 PM
Tag: RTU-2 Exhaust an GKHM_450 Exhaust Pressure Drop Summary Exhaust an Conditions Return External Static Pressure: 1.50 in H2O an Motor BHP: 0.93 BHP Exhaust Internal Pressure Drop: 0.46 in H2O Operating RPM: 1372 RPM Total Exhaust Static Pressure 1.96 in H2O Unit Electrical Data Unit Voltage-Ph-Hz: 208-3-60 Min Circuit Ampacity - MCA: 88.9 Amps Unit Amps - LA: 79.57999 Amps Maximum use Size - MS: 125 Amps Electrical Summary Component an Service Qty HP (ea.) LA (ea.) RLA (ea.) LRA (ea.) ERV/HRV 1 0.17 0.88 Exhaust 1 4 7.6 Scroll 1 15.6 110 Variable Speed Scroll 1 37.1 58 Supply 1 4 7.6 Condenser 2 1 4.2 Controls 1 2.4 Standard Radiated Sound Power Level (dba) 63 125 250 500 1000 2000 4000 8000 Total dba 53.1 77.8 87.1 90 89.1 85.7 79.4 71.4 94.6 Sound power levels are listed for informational purposes only and are not guaranteed. 3 of 4 12/5/2017 2:25:50 PM
Tag: RTU-2 Notes 1. See option list schedule for selected options. 2. See catalog for dimension and weight 3. or single point power connection, Unit Electrical amps include the greater of compressor or electrical heat amps 4. or dual point power connections (electrical heat), Unit Electrical Data does not include electric heat power requirements 4 of 4 12/5/2017 2:25:50 PM