Project Name: Brooks Landing Banquet Center

Similar documents
Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

PHR5. Product Specifications

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

PACKAGE AIR CONDITIONERS

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

CHP SERIES FEATURES. High Pressure Control Three Phase Models. Low Ambient Fan Cycle Control Three Phase Models

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

DCH Commercial Contents Standard Features Cabinet Features

PCB COMMERCIAL SERIES

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

Package Air Conditioners

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

PACKAGE GAS / ELECTRIC ROOFTOP UNITS FORM NO. EXR REV. 4 Supersedes Form No. EXR Rev. 3

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Appendix A. Cooling Coil

Job Name: Tag# 3 Port, 2-Ton Outdoor Heat Pump

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

PRAC14 PRODUCT SPECIFICATIONS

CAS. Product Specifications

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

New Stylus. Product Catalog. Split System, 1-5 Tons Convertible Type MCX Series 60 Hz MS-PRC015-EN. May 2009

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION

N4A6. Product Specifications

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Concealed Ducted Split Series R22

PHB SERIES 7-1/2 and 10 TON

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

WCA4**4. Product Specifications

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

D M S 760 C01 A A 1 1

HCH6. Product Specifications

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Ruud Commercial Achiever Series Package Air Conditioner. Package Air Conditioner

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

CAS. Product Specifications

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Shandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

RGMA Series Package Gas Electric SPECIFICATIONS

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

CSA6. Product Specifications. SoftSound SXC 2600

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data 558J COOLING ONLY/ELECTRIC HEAT PACKAGED ROOFTOP 3 TO 15 TONS. (Unit shown with optional louvered hail guard.) C08515

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

N2AE - 50 Hz PRODUCT SPECIFICATIONS

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Transcription:

Tag: RTU-1 Comments: Unit Information Cooling Performance Heating Performance Model: Horizon (B/G) Unit Length: 208 in Size: G120 Unit Width: 74 in Quantity: 1 Unit Height: 67 in Supply Airflow: 4,000 CM Elevation: 0 ft Outside Airflow: 1,800 CM Ambient Air 95 Minimum Airflow: 1,475 CM Weight Operating: Gross Total Capacity: 126.8 MBh Evaporator ace Area: 10 sq ft Gross Sensible Capacity: 88.1 MBh Evaporator Rows / PI: 4 / 12 Net Total Capacity: 118.4 MBh Condenser ace Area: 25 sq ft Net Sensible Capacity: 79.7 MBh Condenser Rows / PI : 2 / 14 Entering Air DB / WB (Coil): 75.5 / 65.3 Air Velocity: 400 fpm Leaving Air DB / WB (Coil): 55.6 / 54.9 Coil Air PD: 0.37 in H2O Leaving Air DB / WB (Reheat): / EER: 9.7 Note: Leaving Air DB / WB (Unit): 57.9 / 55.8 Watts: 14902 MRE: 2.36 lb/kwh MRC: 35.21 lb/h Heat Type: Gas urnace Entering Air 58.3 Input Capacity 200 MBh Leaving Air 95.3 Output Capacity: 160 MBh Coil Air PD: 0.36 in H2O 4336 lb* Weight does not include CURB weight. See CURB submittal for actual Refrigerant Charge Circuit 1: Circuit 2: 15.6 lbs 15.6 lbs Energy Recovery Wheel ERC-4136C Summer Conditions Ventilation Supply Outside ** TAB Outside airflow through OA Intake to this value Winter Conditions Ventilation Supply Outside Airflow: 1,800 CM Airflow: 1,950 CM** Airflow: 1,800 CM Airflow: 1,950 78.8 88.0 46.4 0.0 66.9 71.0 40.8-1.0 PD: 0.41 in H20 PD: 0.41 in H20 CM** Return Exhaust Return Exhaust Airflow: 1,500 CM Airflow: 1,650 CM Airflow: 1,500 CM 75.0 65.0 84.9 69.5 68.0 55.0 ESP: 0.75 in H20 ERV PD: 0.35 in H20 ESP: 0.75 in H20 Airflow: ERV PD: 1,650 CM 15.6 17.1 0.35 in H20 Total Capaciy: 25.67 MBH Total Capaciy: 124.10 MBH Sensible Capacity: 19.44 MBH Eff. 0.83 Sensible Capacity: 97.68 MBH Eff: 0.84 Latent Capacity: 6.23 MBH Eff: 0.76 Latent Capacity: 26.42 MBH Eff: 0.77 1 of 4 12/5/2017 2:24:40 PM

Tag: RTU-1 Supply an GKHM_450x2 Supply Pressure Drop Summary Supply an Conditions External Static Pressure: 1.00 in H2O an Motor BHP: 3.29 BHP Internal Pressure Drop: 1.50 in H2O Operating RPM: 1581 RPM Total Static Pressure: 2.50 in H2O Minimum RPM: 829 RPM 2 of 4 12/5/2017 2:24:40 PM

Tag: RTU-1 Exhaust an GKHM_450 Exhaust Pressure Drop Summary Exhaust an Conditions Return External Static Pressure: 0.75 in H2O an Motor BHP: 0.69 BHP Exhaust Internal Pressure Drop: 0.55 in H2O Operating RPM: 1164 RPM Total Exhaust Static Pressure 1.30 in H2O Unit Electrical Data Unit Voltage-Ph-Hz: 208-3-60 Min Circuit Ampacity - MCA: 96.5 Amps Unit Amps - LA: 87.17999 Amps Maximum use Size - MS: 125 Amps Electrical Summary Component an Service Qty HP (ea.) LA (ea.) RLA (ea.) LRA (ea.) ERV/HRV 1 0.17 0.88 Exhaust 1 4 7.6 Scroll 1 15.6 110 Variable Speed Scroll 1 37.1 58 Supply 2 4 7.6 Condenser 2 1 4.2 Controls 1 2.4 Standard Radiated Sound Power Level (dba) 63 125 250 500 1000 2000 4000 8000 Total dba 53.1 77.8 87.1 90 89.1 85.7 79.4 71.4 94.6 Sound power levels are listed for informational purposes only and are not guaranteed. 3 of 4 12/5/2017 2:24:40 PM

Tag: RTU-1 Notes 1. See option list schedule for selected options. 2. See catalog for dimension and weight 3. or single point power connection, Unit Electrical amps include the greater of compressor or electrical heat amps 4. or dual point power connections (electrical heat), Unit Electrical Data does not include electric heat power requirements 4 of 4 12/5/2017 2:24:40 PM

Tag: RTU-2 Comments: Unit Information Cooling Performance Heating Performance Model: Horizon (B/G) Unit Length: 208 in Size: G120 Unit Width: 74 in Quantity: 1 Unit Height: 67 in Supply Airflow: 3,500 CM Elevation: 0 ft Outside Airflow: 1,200 CM Ambient Air 95 Minimum Airflow: 1,106 CM Weight Operating: Gross Total Capacity: 124.7 MBh Evaporator ace Area: 10 sq ft Gross Sensible Capacity: 82.7 MBh Evaporator Rows / PI: 4 / 12 Net Total Capacity: 117.7 MBh Condenser ace Area: 25 sq ft Net Sensible Capacity: 75.7 MBh Condenser Rows / PI : 2 / 14 Entering Air DB / WB (Coil): 75.4 / 65.2 Air Velocity: 350 fpm Leaving Air DB / WB (Coil): 54.0 / 53.4 Coil Air PD: 0.31 in H2O Leaving Air DB / WB (Reheat): / EER: 9.4 Note: Leaving Air DB / WB (Unit): 56.2 / 54.3 Watts: 14483 MRE: 2.59 lb/kwh MRC: 37.44 lb/h Heat Type: Gas urnace Entering Air 61.5 Input Capacity 150 MBh Leaving Air 93.2 Output Capacity: 120 MBh Coil Air PD: 0.54 in H2O 4232 lb* Weight does not include CURB weight. See CURB submittal for actual Refrigerant Charge Circuit 1: Circuit 2: 15.6 lbs 15.6 lbs Energy Recovery Wheel ERC-4136C Summer Conditions Ventilation Supply Outside ** TAB Outside airflow through OA Intake to this value Winter Conditions Ventilation Supply Outside Airflow: 1,200 CM Airflow: 1,405 CM** Airflow: 1,200 CM Airflow: 1,405 78.3 88.0 49.1 0.0 66.7 71.0 42.6-1.0 PD: 0.29 in H20 PD: 0.29 in H20 CM** Return Exhaust Return Exhaust Airflow: 1,000 CM Airflow: 1,205 CM Airflow: 1,000 CM 75.0 65.0 86.3 70.1 68.0 55.0 ESP: 1.50 in H20 ERV PD: 0.26 in H20 ESP: 1.50 in H20 Airflow: ERV PD: 1,205 CM 8.4 9.9 0.26 in H20 Total Capaciy: 18.00 MBH Total Capaciy: 87.03 MBH Sensible Capacity: 14.73 MBH Eff. 0.87 Sensible Capacity: 74.46 MBH Eff: 0.88 Latent Capacity: 3.26 MBH Eff: 0.8 Latent Capacity: 12.57 MBH Eff: 0.81 1 of 4 12/5/2017 2:25:50 PM

Tag: RTU-2 Supply an GKHM_450 Supply Pressure Drop Summary Supply an Conditions External Static Pressure: 1.00 in H2O an Motor BHP: 2.75 BHP Internal Pressure Drop: 1.42 in H2O Operating RPM: 1821 RPM Total Static Pressure: 2.42 in H2O Minimum RPM: 1021 RPM 2 of 4 12/5/2017 2:25:50 PM

Tag: RTU-2 Exhaust an GKHM_450 Exhaust Pressure Drop Summary Exhaust an Conditions Return External Static Pressure: 1.50 in H2O an Motor BHP: 0.93 BHP Exhaust Internal Pressure Drop: 0.46 in H2O Operating RPM: 1372 RPM Total Exhaust Static Pressure 1.96 in H2O Unit Electrical Data Unit Voltage-Ph-Hz: 208-3-60 Min Circuit Ampacity - MCA: 88.9 Amps Unit Amps - LA: 79.57999 Amps Maximum use Size - MS: 125 Amps Electrical Summary Component an Service Qty HP (ea.) LA (ea.) RLA (ea.) LRA (ea.) ERV/HRV 1 0.17 0.88 Exhaust 1 4 7.6 Scroll 1 15.6 110 Variable Speed Scroll 1 37.1 58 Supply 1 4 7.6 Condenser 2 1 4.2 Controls 1 2.4 Standard Radiated Sound Power Level (dba) 63 125 250 500 1000 2000 4000 8000 Total dba 53.1 77.8 87.1 90 89.1 85.7 79.4 71.4 94.6 Sound power levels are listed for informational purposes only and are not guaranteed. 3 of 4 12/5/2017 2:25:50 PM

Tag: RTU-2 Notes 1. See option list schedule for selected options. 2. See catalog for dimension and weight 3. or single point power connection, Unit Electrical amps include the greater of compressor or electrical heat amps 4. or dual point power connections (electrical heat), Unit Electrical Data does not include electric heat power requirements 4 of 4 12/5/2017 2:25:50 PM