Technical Data Sheets

Similar documents
Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical data sheets

POWER kva

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

EFFEKTA Power Supplies

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

PowerScale kva Technical Specifications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

PowerValue 11/31 T kva

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PowerScale TECHNICAL SPECIFICATIONS

TECHNICAL DATA SHEET KVA UPS Systemss

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

POWERTRONIX QUASAR 5-40 KVA

ConceptpowerTM Modular kVA

Industrial PFC UPS System

TECHNICAL SPECIFICATIONS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Master DIALOG INDUSTRY RANGE

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Master Plus kva

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

D Series: UPS UPTO - 300KVA - Three / Three Phase

Master Plus kva

UPS Multi Sentry 10-20kVA

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Specification SENTINEL PRO

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Three Phase UPS Systems Range: 10 to 500kVA

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

1.1 GENERAL CHARACTERISTICS

LanPro 11 U. Product Description. GE Digital Energy. Uninterruptible Power Supply. LanPro UPS. Technology for the Digital World.

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

60 to 160 kva.

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MKN-DSP SERIES - THREE PHASE

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

PowerWave 33 Efficient power protection for today s IT and process-related work environments

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Marketing Management Team of Europe

Liebert. FP 50Z kva

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Master MPS kva kva 3:1 3:3 VFI TYPE

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Master MPS kva kva 3:1 3:3 VFI TYPE

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Green Power 2.0 MASTERYS GP

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

MASTERYS IP+ 10 to 80 kva

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

SR series. on-line

DC POWER SUPPLY SYSTEMS

Transcription:

GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE Digital Energy General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com

GENERAL DATA Topology VFI-SS-111, double conversion Output power kva 10 20 30 Max. active power at nominal operating conditions kw 10 20 30 Overall efficiency at 100% load in VFI mode % 91.1 91.6 91 Overall efficiency at 100% load in ECO mode % 98.2 98.6 98.5 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw 0.78 1.47 2.37 Cooling air (25 C 30 C) m 3 /h 235 430 700 Audible noise level db(a) 53 55 60 Battery type Operating temperature range Storage temperature range Storage time of the battery without recharge at 20 C Relative humidity Valve regulated lead-acid (VRLA) : Battery: -25 C +55 C Max. 6 months 0 C 40 C (nominal 25 C) 20 C 25 C recommended Max. 95% (non-condensing) (higher the temperature, shorter the storage time of the battery) Max. altitude without power derating Power derating (according to IEC 62040-3) 1000m 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) s EMC Electrostatic discharge immunity Internal protection Enclosure Transport Colour Installation External cable connections Cooling Paralleling (RPA version) EN 50091 / IEC 62040, CE marking EN 50091-2 / IEC 62040-2 Class A 4kV contact / 8kV air discharge All live parts shrouded Metal sheet and castors Cabinet suitable for handling by forklift RAL 9010 (white) Minimum distance from the wall 5 cm Bottom left Forced side to top by internal blower Up to 4 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge input voltage Input frequency Input power factor Input current distortion (THD) <8% Three phase, overtemperature protection Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 323V 478V 50/60Hz +/-10% (45 66 Hz) >0.98 lag. Output voltage tolerance +/- 1% Battery ripple current Battery charging characteristic Battery charging current limit <40 ma (pk-pk) IU (DIN 41773), T compensated floating voltage Selectable: 1.4 A, 2.8 A, 4.2 A Input power data kva 10 20 30 Input power at inverter nominal load, PF=0.8 lag. and charged battery Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 8.96 17.83 26.91 kw 9.86 19.63 29.61 Max. battery charging current (default) A 1.4 2.8 4.2 Modifications reserved Page 2/5

BATTERY Battery type Valve regulated lead-acid (VRLA) Number of blocks (12V / 7Ah) 1 x 40 (10 kva) 2 x 40 (20 kva) 3 x 40 (30 kva) Float voltage at 20 C 2 x 273 VDC Min. discharge voltage 2 x 192 VDC Recharge time 6 8 hours Automatic and manual battery test Battery power data kva 10 20 30 DC power at full load and PF=0.8 lag. kw 8.42 16.84 25.26 autonomy time at 100% load and PF=0.8 lag. Min. 10 10 10 autonomy time at 50% load and PF=0.8 lag. Min. 26 26 26 Matching battery cabinets See optional features on page 4 INVERTER Nominal output power at PF=0.6... 1.0 lag. 10 20 30 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge IGBT technology Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... <2% - output voltage THD for 100% non-linear load (EN 50091) <3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... +/- 1% - at 100% unbalanced load... +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 100 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection - Common input (Rectifier & Bypass) - Dual input (optional) - Thyristors (SSM - Static Switch Module) Primary components - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass Voltage limits for inverter/bypass load transfers +/- 10% Overload on bypass 200% for 2 min. and 1000% for 10 ms, non repetitive INTERFACING - 4 Potential free contacts - 28 user settable signals Serial channel RS232 (on Delta 9 pin connector) EPO (Emergency Power Off) - Genset-On contact Extended Customer Interface Card (optional) - 6 potential free alarm contacts - 1 auxiliary contact Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 3/5

FRONT PANEL CONTROLS, SIGNALS AND ALARMS Warning SGT4000_010-020 GE_01 Metering Menu Operation Digital Energy TM LP Series + Enter LPS33_control panel_02 LCD SCREEN Shows the data system data, events messages and setting. The data is displayed on 4 rows, 20 characters each, allowing the operator to select between English, German, French, Spanish, Italian, Finnish or Polish language. CONTROL PANEL Metering Menu Electrical parameters, operating statistics and information screens. Events (alarms, messages, commands, handling, etc.) and resets general alarm / buzzer. Settings, LED-test and commands. + Scroll to following screen. - Scroll to previous screen. Enter Confirms the selected command. INDICATION LED S (red) On: No mains available. Load supply at risk due to: - Battery empty; - Overtemperature; - Overload. Warning (yellow) Blinking: not jeopardizing load supply. Operation (green) On: LOAD ON INVERTER Blinking: SERVICE REQUIRED OPTIONS BUILT-IN OPTIONS: 1. Customer Interface 2. RPA kit 3. Separate mains input (one for rectifier / one for bypass) 4. Additional battery charger COMMUNICATION: 1. Advanced SNMP Card 2. JUMP software suite 3. IRIS service 4. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: 1. Empty battery cabinets (see page 4) 2. Battery fuse box Modifications reserved Page 4/5

TECHNICAL DATA SGT4000_010-020_ dimensions_ge_01 LP 33 Series 10 20-30 kva 1310 rating without battery floor loading with st. shipping WEIGHT with battery with battery Floor loading with standard shipping 10 kva 135 Kg 347 Kg/m 2 165 Kg 269* - 367 Kg 690* - 941 Kg/m 2 299* - 397 Kg 20 kva 147 Kg 377 Kg/m 2 170 Kg 379 Kg (14 Ah) 972 Kg (14 Ah) 402 Kg (14 Ah) 30 kva 185 Kg 360 Kg/m 2 200 Kg 533 Kg (21 Ah) 1036 Kg (21 Ah) 548 Kg (21 Ah) (*) Battery 7Ah ( ) Battery 14Ah BATTERY TABLE rating Battery capacity Autonomy WEIGHT time Cabinet & Battery Floor loading shipping LPS33_battery cabinet dimensions_01 Battery cabinet 780 760 1050 10 kva 20 kva 7 Ah 10 min. 14 Ah (2 x 7 Ah) 25 min. Mounted inside the cabinet (see Weight table) 21 Ah (3 x 7 Ah) 45 min. 450 Kg 760 Kg/m 2 510 Kg 28 Ah (4 x 7 Ah) 60 min. 570 Kg 962 Kg/m 2 630 Kg 35 Ah (5 x 7 Ah) 80 min. 690 Kg 1164 Kg/m 2 750 Kg 42 Ah (6 x 7 Ah) 100 min. 810 Kg 1367 Kg/m 2 870 Kg 14 Ah (2 x 7 Ah) 10 min. Mounted inside the cabinet (see Weight table) 21 Ah (3 x 7 Ah) 20 min. 450 Kg 760 Kg/m 2 510 Kg 28 Ah (4 x 7 Ah) 28 min. 570 Kg 962 Kg/m 2 630 Kg 35 Ah (5 x 7 Ah) 37 min. 690 Kg 1164 Kg/m 2 750 Kg 42 Ah (6 x 7 Ah) 45 min. 810 Kg 1367 Kg/m 2 870 Kg 21 Ah (3 x 7 Ah) 10 min. Mounted inside the cabinet (see Weight table) 28 Ah (4 x 7 Ah) 15 min. 570 Kg 962 Kg/m 2 630 Kg 30 kva 35 Ah (5 x 7 Ah) 22 min. 690 Kg 1164 Kg/m 2 750 Kg 42 Ah (6 x 7 Ah) 28 min. 810 Kg 1367 Kg/m 2 870 Kg Battery autonomy time at 100% load and PF=0.8 lag., only with High Rate Battery. BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass (optional) Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections A, B, C, D, E and K recommended by European s Alternatively, local standards to be respected kva Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 (battery) A / B /C D E K 10 3 x 25 A 3 x 20 A 3 x 20 A 3 x 25 A 5 x 4 4 x 2.5 5 x 2.5 4 x 4 20 3 x 50 A 3 x 50 A 3 x 35 A 3 x 50 A 5 x 10 4 x 6 5 x 6 4 x 10 30 3 x 63 A 3 x 63 A 3 x 50 A 3 x 80 A 5 x 10 4 x 10 5 x 10 4 x 16 SEV/ASE cable sections recommended in Switzerland (mm 2 ) kva A / B /C D E K F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer 10 5 x 6 4 x 4 5 x 4 4 x 6 K: supplied by GE only with battery 20 5 x 16 4 x 10 5 x 10 4 x 16 F4: can be supplied by GE 30 5 x 16 4 x 16 5 x 16 4 x 256 Modifications reserved Page 5/5