Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Similar documents
Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva

POWER kva

EFFEKTA Power Supplies

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

PowerValue 11/31 T kva

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

TECHNICAL DATA SHEET KVA UPS Systemss

PowerScale kva Technical Specifications

ConceptpowerTM Modular kVA

POWERTRONIX QUASAR 5-40 KVA

PowerScale TECHNICAL SPECIFICATIONS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Industrial PFC UPS System

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TECHNICAL SPECIFICATIONS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

60 to 160 kva.

1.1 GENERAL CHARACTERISTICS

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

UPS Multi Sentry 10-20kVA

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Power+ CLASSIC. 20/30 kva, 3x208 Vac

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

MASTERYS IP+ 10 to 80 kva

Master DIALOG INDUSTRY RANGE

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Master Plus kva

Master Plus kva

Green Power 2.0 MASTERYS GP

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

Technical Specification SENTINEL PRO

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

AME. Rectifier - Battery charger. Industrial applications: Key features:

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Three Phase UPS Systems Range: 10 to 500kVA

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Liebert. FP 50Z kva

SR series. on-line

MKN-DSP SERIES - THREE PHASE

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Marketing Management Team of Europe

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

LanPro 11 U. Product Description. GE Digital Energy. Uninterruptible Power Supply. LanPro UPS. Technology for the Digital World.

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Master MPS kva kva 3:1 3:3 VFI TYPE

User Manual. GE Critical Power. imagination at work. Uninterruptible Power Supply

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Transcription:

Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gepowerquality.com g imagination at work

Digital Energy Model: Issued by: Approved by: LP33 Series 10 & 20 CE S6 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 01.07.2012 File name: GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010 Revision: 1.0 Identification No.: Up-dating Revision Concern Date COPYRIGHT 2012 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE Dgital Energy. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6 GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010.docx Technical Data Sheet LP33 Series 10 & 20 CE S3

Digital Energy GENERAL DATA Topology VFI-SS-111, double conversion Output power kva 10 20 Output nominal power factor (lag.) 1.0 1.0 Max. active power at nominal operating conditions kw 10 20 Overall efficiency at 100% load in VFI mode % 92.0 92.4 Overall efficiency at 100% load in ECO mode % 98.2 98.6 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw 0.87 1.65 Cooling air (25 C 30 C) m 3 /h 260 490 Audible noise level db(a) 53 53 Battery type Operating temperature range Storage temperature range Storage time of the battery without recharge at 20 C Relative humidity Max. altitude without power derating Power derating (according to EN/IEC 62040-3) Valve regulated lead-acid (VRLA) UPS: Battery: -25 C +55 C Max. 6 months 0 C 40 C (nominal 25 C) 20 C 25 C recommended Max. 95% (non-condensing) Protection degree IP 20 (IEC 60529) Standards EMC Electrostatic discharge immunity Internal protection Enclosure Transport Colour Installation External cable connections Cooling Paralleling (RPA version) (higher the temperature, shorter the storage time of the battery) 1000m 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% EN 50091 / EN/IEC 62040, CE marking EN 50091-2 / EN/IEC 62040-2 Class A 4kV contact / 8kV air discharge All live parts shrouded Metal sheet and castors Cabinet suitable for handling by forklift RAL 9003 (white) Minimum distance from the wall 5 cm Bottom left Forced from bottom side to left upper side by internal blower Up to 4 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Standard input voltage Input frequency Input power factor Input current distortion (THD) <8% Three phase, overtemperature protection Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 323V 460V (ph-n 186V 265V) 50/60Hz +/-10% (45 66 Hz) >0.98 lag. Output voltage tolerance +/- 1% Battery ripple current Battery charging characteristic Battery charging current limit <40 ma (pk-pk) IU (DIN 41773), T compensated floating voltage Selectable: 1.4A, 2.8A, 4.2A (option up to 8.4A) Input power data kva 10 20 Input power at inverter nominal load, PF=1.0 and charged battery Max. input power at inverter nominal load and max. battery charging current (default setting) kw 10.9 21.6 kw 11.6 23.1 Max. battery charging current (default setting) A 1.4 2.8 Modifications reserved Page 3/6 GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010.docx Technical Data Sheet LP33 Series 10 & 20 CE S3

Digital Energy BATTERY Battery type Valve regulated lead-acid (VRLA) Number of blocks mounted inside the UPS cabinet (12V / 7Ah) 10kVA: 40 (2x20) 20kVA: 80 (2x2x20) Float voltage at 20 C 2 x 273 Vdc Min. discharge voltage 2 x 198 Vdc (1.65 V/cell) Recharge time 6 8 hours Automatic and manual battery test Standard Battery power data kva 10 20 DC power at full load and PF=0.8 lag. kw 8.8 17.5 Standard autonomy time at 100% load and PF=0.8 lag. Min. 10 10 Standard autonomy time at 50% load and PF=0.8 lag. Min. 26 26 Battery autonomy time at 100% load and PF=0.8 lag., only with High Rate Battery. Matching battery cabinets See optional features on page 6 INVERTER Nominal output power 10 & 20 kva at PF=0.6 1.0 lag. Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge IGBT technology Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... <2% - output voltage THD for 100% non-linear load (EN 62040) <3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 100 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection - Common input (Rectifier & Bypass) - Dual input (optional) - Thyristors (SSM - Static Switch Module) Primary components - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass Voltage limits for inverter/bypass load transfers +/- 10% Overload on bypass 200% for 2 min. and 1000% for 10 ms, non repetitive INTERFACING Potential free contacts Serial channel RS232 (on Delta 9 pin connector) EPO (Emergency Power Off) Extended Customer Interface Card (optional) Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6 GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010.docx - 4-28 user settable signals Standard Standard - Genset-On contact - 6 potential free alarm contacts - 1 auxiliary contact Technical Data Sheet LP33 Series 10 & 20 CE S3

Digital Energy CONTROL PANEL The Control Panel, positioned on the UPS front-top, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Synoptic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS BUILT-IN UPS OPTIONS: 1. RPA kit 2. Separate mains input (one for rectifier / one for bypass) 3. Additional battery charger COMMUNICATION: 1. Customer Interface Board 2. 3-ph SNMP/WEB plug-in adapter 3. GE Power Diagnostics 4. GE Data Protection 5. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: 1. Battery cabinets (see page 6) 2. Battery fuse box Modifications reserved Page 5/6 GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010.docx Technical Data Sheet LP33 Series 10 & 20 CE S3

1320 1320 Digital Energy TECHNICAL DATA LP33 Series 10 & 20 LPS33_010-020_S6_UPS dimensions_ge_01 UPS rating UPS UPS without battery UPS floor loading UPS with st. shipping WEIGHT UPS with battery UPS with battery Floor loading UPS with standard shipping 10 kva 140 kg 359 kg/m 2 170 kg 270* - 370 kg 693* - 949 kg/m 2 300* - 400 kg 20 kva 150 kg 385 kg/m 2 180 kg 375 kg (14 Ah) 962 kg/m 2 (14 Ah) 405 kg (14 Ah) (*) Battery 7Ah ( ) Battery 14Ah (2x7Ah) BATTERY TABLE UPS rating Battery capacity Autonomy time WEIGHT Cabinet & Battery Floor loading Standard shipping 780 LPS33_010-020_S6_Battery cabinet_01 500 Battery cabinet 10 kva 7 Ah 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 14 Ah (2 x 7 Ah) 25 min. 21 Ah (3 x 7 Ah) 45 min. 450 kg 760 kg/m 2 480 kg 28 Ah (4 x 7 Ah) 60 min. 570 kg 962 kg/m 2 600 kg 35 Ah (5 x 7 Ah) 80 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 100 min. 810 kg 1367 kg/m 2 840 kg 14 Ah (2 x 7 Ah) 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 21 Ah (3 x 7 Ah) 20 min. 450 kg 760 kg/m 2 480 kg 20 kva 28 Ah (4 x 7 Ah) 28 min. 570 kg 962 kg/m 2 600 kg 780 780 35 Ah (5 x 7 Ah) 37 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 45 min. 810 kg 1367 kg/m 2 840 kg Battery autonomy time at 100% load and PF=0.8 lag., only with High Power Battery. UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass (optional) kva Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections recommended by European Standards Alternatively, local standards to be respected Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 (battery) A / B /C D E K 10 3 x 25 A 3 x 25 A 3 x 20 A 3 x 25 A 5 x 4 4 x 2.5 5 x 2.5 4 x 4 20 3 x 50 A 3 x 50 A 3 x 35 A 3 x 50 A 5 x 10 4 x 6 5 x 6 4 x 10 Cable sections recommended in Switzerland (mm 2 ) F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer kva A / B /C D E K K: supplied by GE only with battery 10 5 x 6 4 x 4 5 x 4 4 x 6 F4: can be supplied by GE Digital Energy 20 5 x 16 4 x 10 5 x 10 4 x 16 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6 GE_UPS_TDS_LPS_33E_10K_20K_6GB_V010.docx Technical Data Sheet LP33 Series 10 & 20 CE S3

GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

Model: LP 33 Series 10 20 30-40 kva, Series 5 Date of issue: 15.01.2008 File name: TDS_LPS_33E_10K_40K_5GB_V010 Revision: 1.0 Identification No. Up-dating Revision Concern Date COPYRIGHT 2008 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6 TDS_LPS_33E_10K_40K_5GB_V010.doc Technical Data Sheets LP 33 Series 10-20-30-40 kva / S5

GENERAL DATA Topology VFI-SS-111, double conversion Output power kva 10 20 30 40 Output nominal power factor (lag.) 1.0 1.0 1.0 0.8 Max. active power at nominal operating conditions kw 10 20 30 32 Overall efficiency at 100% load in VFI mode % 91.1 91.6 91.0 91.7 Overall efficiency at 100% load in ECO mode % 98.2 98.6 98.5 98.0 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw 0.78 1.47 2.37 2.90 Cooling air (25 C 30 C) m 3 /h 235 430 700 850 Audible noise level db(a) 53 55 60 65 Battery type Valve regulated lead-acid (VRLA) Operating temperature range UPS: 0 C 40 C (nominal 25 C) Battery: 20 C 25 C recommended Storage temperature range -25 C +55 C (higher the temperature, shorter the storage time of the battery) Storage time of the battery without recharge at 20 C Max. 6 months Relative humidity Max. 95% (non-condensing) Max. altitude without power derating 1000m Power derating (according to EN/IEC 62040-3) 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) Standards EN 50091 / EN/IEC 62040, CE marking EMC EN 50091-2 / EN/IEC 62040-2 Class A Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All live parts shrouded Enclosure Metal sheet and castors Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Minimum distance from the wall 5 cm External cable connections Bottom left Cooling Forced side to top by internal blower Paralleling (RPA version) Up to 4 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Three phase, overtemperature protection Standard input voltage Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 323V 460V Input frequency 50/60Hz +/-10% (45 66 Hz) Input power factor >0.98 lag. Input current distortion (THD) <8% Output voltage tolerance +/- 1% Battery ripple current <40 ma (pk-pk) Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Selectable: 1.4 A, 2.8 A, 4.2 A Input power data kva 10 20 30 40 Input power at inverter nominal load, PF=0.8 lag. and charged battery kw 8.78 17.47 26.37 34.90 Max. input power at inverter nominal load and max. kw battery charging current (selectable) 9.68 19.27 29.07 37.12 Max. battery charging current (default inside battery) A 1.4 2.8 4.2 4.2 Modifications reserved Page 3/6 TDS_LPS_33E_10K_40K_5GB_V010.doc Technical Data Sheets LP 33 Series 10-20-30-40 kva / S5

BATTERY Battery type Valve regulated lead-acid (VRLA) Number of blocks mounted inside the UPS cabinet (12V / 7Ah) 10kVA: 40 (2x20) 20kVA: 80 (2x2x20) 30-40kVA: 120 (3x 2x20) Float voltage at 20 C 2 x 273 Vdc Min. discharge voltage 2 x 198 Vdc (1.65 V/cell) Recharge time 6 8 hours Automatic and manual battery test Standard Battery power data kva 10 20 30 40 DC power at full load and PF=0.8 lag. kw 8.8 17.5 26.4 35.0 Standard autonomy time at 100% load and PF=0.8 lag. Min. 10 10 10 7 Standard autonomy time at 50% load and PF=0.8 lag. Min. 26 26 26 15 Battery autonomy time at 100% load and PF=0.8 lag., only with High Rate Battery. Matching battery cabinets See optional features on page 6 INVERTER Nominal output power 10 20 30 kva at PF=0.6 1.0 lag. 40 kva at PF=0.6 0.8 lag. Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge IGBT technology Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... <2% - output voltage THD for 100% non-linear load (EN 50091) <3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 100 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection - Common input (Rectifier & Bypass) - Dual input (optional) - Thyristors (SSM - Static Switch Module) Primary components - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass Voltage limits for inverter/bypass load transfers +/- 10% Overload on bypass 200% for 2 min. and 1000% for 10 ms, non repetitive INTERFACING - 4 Potential free contacts - 28 user settable signals Serial channel RS232 (on Delta 9 pin connector) Standard EPO (Emergency Power Off) Standard - Genset-On contact Extended Customer Interface Card (optional) - 6 potential free alarm contacts - 1 auxiliary contact Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6 TDS_LPS_33E_10K_40K_5GB_V010.doc Technical Data Sheets LP 33 Series 10-20-30-40 kva / S5

CONTROL PANEL The control panel, positioned on the UPS front-top, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Synoptic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS BUILT-IN UPS OPTIONS: 1. Customer Interface 2. RPA kit 3. Separate mains input (one for rectifier / one for bypass) 4. Additional battery charger COMMUNICATION: 1. Advanced SNMP Card 2. GE Power Diagnostics 3. GE Data Protection 4. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: 1. Battery cabinets (see page 6) 2. Battery fuse box Modifications reserved Page 5/6 TDS_LPS_33E_10K_40K_5GB_V010.doc Technical Data Sheets LP 33 Series 10-20-30-40 kva / S5

TECHNICAL DATA LP 33 Series 10 20 30 40 kva Battery cabinet UPS rating UPS UPS without battery UPS floor loading UPS with st. shipping WEIGHT UPS with battery UPS with battery Floor loading UPS with standard shipping 10 kva 140 kg 359 kg/m 2 170 kg 270* - 370 kg 693* - 949 kg/m 2 300* - 400 kg 20 kva 150 kg 385 kg/m 2 180 kg 375 kg (14 Ah) 962 kg/m 2 (14 Ah) 405 kg (14 Ah) 30 kva 195 kg 379 kg/m 2 230 kg 555 kg (21 Ah) 1078 kg/m 2 (21 Ah) 590 kg (21 Ah) 40 kva 200 kg 389 kg/m 2 235 kg 560 kg (21 Ah) 1088 kg/m 2 (21 Ah) 595 kg (21 Ah) (*) Battery 7Ah ( ) Battery 14Ah (2x7Ah) BATTERY TABLE UPS Battery Autonomy WEIGHT rating capacity time Cabinet & Battery Floor loading Standard shipping 7 Ah 10 min. 14 Ah (2 x 7 Ah) 25 min. Mounted inside the UPS cabinet (see WEIGHT table) 10 kva 21 Ah (3 x 7 Ah) 45 min. 450 kg 760 kg/m 2 480 kg 28 Ah (4 x 7 Ah) 60 min. 570 kg 962 kg/m 2 600 kg 35 Ah (5 x 7 Ah) 80 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 100 min. 810 kg 1367 kg/m 2 840 kg 14 Ah (2 x 7 Ah) 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 21 Ah (3 x 7 Ah) 20 min. 450 kg 760 kg/m 2 480 kg 20 kva 28 Ah (4 x 7 Ah) 28 min. 570 kg 962 kg/m 2 600 kg 35 Ah (5 x 7 Ah) 37 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 45 min. 810 kg 1367 kg/m 2 840 kg 21 Ah (3 x 7 Ah) 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 30 kva 28 Ah (4 x 7 Ah) 15 min. 570 kg 962 kg/m 2 605 kg 35 Ah (5 x 7 Ah) 22 min. 690 kg 1164 kg/m 2 725 kg 42 Ah (6 x 7 Ah) 28 min. 810 kg 1367 kg/m 2 845 kg 21 Ah (3 x 7 Ah) 7 min. Mounted inside the UPS cabinet (see WEIGHT table) 40 kva 28 Ah (4 x 7 Ah) 11 min. 570 kg 962 kg/m 2 605 kg 35 Ah (5 x 7 Ah) 14 min. 690 kg 1164 kg/m 2 725 kg 42 Ah (6 x 7 Ah) 18 min. 810 kg 1367 kg/m 2 845 kg Battery autonomy time at 100% load and PF=0.8 lag., only with High Power Battery. UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass (optional) Protections and cable sections Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Cable sections recommended by European Standards Alternatively, local standards to be respected kva Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 (battery) A / B /C D E K 10 3 x 25 A 3 x 25 A 3 x 20 A 3 x 25 A 5 x 4 4 x 2.5 5 x 2.5 4 x 4 20 3 x 50 A 3 x 50 A 3 x 35 A 3 x 50 A 5 x 10 4 x 6 5 x 6 4 x 10 30 3 x 63 A 3 x 63 A 3 x 50 A 3 x 80 A 5 x 10 4 x 10 5 x 10 4 x 16 40 3 x 63 A 3 x 63 A 3 x 63 A 3 x 80 A 5 x 10 4 x 10 5 x 10 4 x 16 Cable sections recommended in Switzerland (mm 2 ) kva A / B /C D E K 10 5 x 6 4 x 4 5 x 4 4 x 6 F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer 20 5 x 16 4 x 10 5 x 10 4 x 16 K: supplied by GE only with battery 30 5 x 16 4 x 16 5 x 16 3 x 25 + 1 x 16 F4: can be supplied by GE 40 5 x 16 4 x 16 5 x 16 3 x 25 + 1 x 16 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6 TDS_LPS_33E_10K_40K_5GB_V010.doc Technical Data Sheets LP 33 Series 10-20-30-40 kva / S5

GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 60 80 100 120 kva 400 Vac CE Series 2 LP 33 Series 100-120 kva LP 33 Series 60-80 kva LPS33_060-120_S2_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

Model: LP 33 Series 60 80 100-120 kva / Series 2 Issued by: Product Document Department Riazzino - CH Date of issue: 01.15.2009 File name: TDS_LPS_33E_60K_M12_2GB_V010 Revision: 1.0 Identification No. Up-dating Revision Concern Date COPYRIGHT 2009 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6 TDS_LPS_33E_60K_M12_2GB_V010.doc Technical Data Sheets LP 33 Series 60-80-100-120 kva / S2

GENERAL DATA Topology VFI-SS-111, double conversion Nominal output apparent power at PF=0.6...0.8 lag. kva 60 80 100 120 Nominal output effective power at PF=0.8 lag. kw 48 64 80 96 Overall efficiency at 100% load in VFI mode % 93.3 92.8 92.8 92.8 Overall efficiency at 100% load in ECO mode % 98.8 99 98.8 98.8 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw 3.45 4.97 6.21 7.45 Cooling air (25 C 30 C) m 3 /h 1010 1450 1815 2175 Audible noise level Battery type Operating temperature range UPS: 0 C 40 C Storage temperature range Relative humidity db(a) 67 67 70 70 Valve regulated lead-acid (VRLA) -25 C +55 C Max. 95% (non-condensing) Max. altitude without power derating Power derating (according to EN/IEC 62040-3) 1000m 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) Standards EN 50091 / EN/IEC 62040, CE marking EMC EN 50091-2 Class A / EN/IEC 62040-2 Category C2 Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Can be positioned against a wall and floor fixed Service access Front access only External cable connections Bottom Cooling Forced front to top by internal blower Paralleling (RPA version) Up to 4 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Three phase - Active IGBT Rectifier Standard input voltage Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 323V 460V Input frequency 50/60Hz +/-10% (45 66 Hz) Input power factor 0.98 lag. Input current THD Active IGBT Rectifier: <9% Active IGBT Rectifier - Clean Input Module: <4.5% (<3.5% @ 75% load) Output voltage tolerance +/- 1% Battery ripple current <200 ma (pk-pk) Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 60 80 100 120 Input power at inverter nominal load, PF=0.8 lag. and charged battery kw 51.5 69 86 103.2 Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 60.1 77.6 94.6 111.8 Max. battery charging current (programmable) A 15 15 15 15 Modifications reserved Page 3/6 TDS_LPS_33E_60K_M12_2GB_V010.doc Technical Data Sheets LP 33 Series 60-80-100-120 kva / S2

BATTERY Battery type Valve regulated lead-acid (VRLA) Number of 12V blocks, 6 cells/block 40, placed in exte rnal cabinets Float voltage at 20 C 2 x 273 VDC Min. discharge voltage (programmable) 1.65V / cell Recharge time 6 8 hours Automatic and manual battery test Standard Common battery in parallel system Up to 4 units Battery power data kva 60 80 100 120 DC power at full load and PF=0.8 lag. kw 51 68 85. 1 102.2 DC power at full typical computer load (PF=0.66 lag.) kw 42.1 56.2 70.2 84.3 Matching battery cabinets See optional feat ures on page 5 INVERTER Nominal output power at PF=0.6... 0.8 lag. 60 80-100 - 120 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge IGBT technology Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (a t load step 0 100 0%)...... +/- 1% - dyn amic (at load step 0 50 0%)...... +/- 0.5% - recovery time to +/-1%...... <3 ms - output voltage THD for 100% linear load... <1% - output voltage THD for 100% non-linear load (EN 50091) <2.5% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchroni sation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... Overload capability (at PF=0.8) 120 : +/- 2% 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 100 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) C rest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass - Common input (Rectifier & Bypass) - Dual input (optional) - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes 45 times In for 10 ms, non repetitive INTERFACING - 4 Potential free contacts - 28 user settable signals Serial channel RS232 (on Delta 9 pin connector) Standard EPO (Emergency Power Off) Standard - Genset-On contact Extended Customer Interface Card (optional) - 6 potential free alarm contacts - 1 auxiliary contact Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6 TDS_LPS_33E_60K_M12_2GB_V010.doc Technical Data Sheets LP 33 Series 60-80-100-120 kva / S2

FRONT PANEL CONTROLS, SIGNALS AND ALARMS The control panel, positioned on the UPS front door, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following charact eristics: Multilanguage commu nication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Graphic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS BUILT-IN UPS OPTIONS: 1. Customer Interface 2. RPA kit 3. EMC filter EN/IEC 62040-2 Category C2 (Class A) for common o r separate mains input (one for rectifier / one for bypass) 4. Input THDI <4.5% COMMUNICATION: 1. Advanced SNMP Card 2. JUMP software suite 3. IRIS service 4. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: 1. Empty battery cabinets Dimensions (WxDxH): 430x725x1815 600x725x1815 780x725x1815 UPS rating Battery Capacity (High rate battery) BATTERY TABLE Autonomy time Cabinet Weight 1 2 3 60 kva 80 kva 33 Ah 9 minutes 520 Kg 50 Ah 12 minutes 775 Kg 66 Ah (2x33Ah) 19 minutes 960 Kg 50 Ah 10 minutes 775 Kg 66 Ah (2x33Ah) 12 minutes 960 Kg 100 k VA 66 Ah (2x33Ah) 10 minutes 1010 Kg LPS33_060-120_OPT_Cabinets battery_01 120 kva 66 Ah (2x33Ah) 9 minutes 1010 Kg Modifications reserved Page 5/6 TDS_LPS_33E_60K_M12_2GB_V010.doc Technical Data Sheets LP 33 Series 60-80-100-120 kva / S2

Inverter Total Off Inverter Total Off TECHNICAL DATA LP 33 Series 60-80 kva 745mm 600mm 725mm LP 33 Series 100-120 kva 745mm 720mm 725mm g g LPS33_060-080_S2_UPS dimensions_01 LPS3 3_100-120_S2_UPS dimensions_01 1815mm 1815mm UPS rating 60 kva 80 kva 100 kva 120 kva UPS weight 275 Kg 300 Kg 370 Kg 375 Kg UPS floor loading 633 Kg/m 2 690 Kg/m 2 709 Kg/m 2 719 Kg/m 2 UPS packed in carton 295 Kg 320 Kg 395 Kg 400 Kg UPS packed in wooden crate 370 Kg 395 Kg 475 Kg 480 Kg UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass (optional) Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections A, B, C, D, E and K recommended by European Standards Alternatively, local standards to be respected Cable sections (mm 2 ) kva Fuses AgL or equivalent MTCB F1 F2 F3 F4 A / B /C D E K 60 3 x 100 A 3 x 100 A 3 x 100 A 3 x 125 A 4 x 25 + 16 4 x 25 4 x 25 + 16 3 x 35 + 25 80 3 x 125 A 3 x 125 A 3 x 125 A 3 x 160 A 4 x 35 + 25 4 x 35 4 x 35 + 25 3 x 50 + 25 100 3 x 160 A 3 x 160 A 3 x 160 A 3 x 200 A 4 x 50 + 25 4 x 50 4 x 50 + 25 3 x 70 + 35 120 3 x 200 A 3 x 200 A 3 x 200 A 3 x 250 A 4 x 70 + 35 4 x 70 4 x 70 + 35 3 x 120 + 70 Cable sections recomm ended in Switzerland ( mm 2 ) kva A / B /C D E K 60 4 x 35 + 25 4 x 35 4 x 35 + 25 3 x 50 + 25 F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer 80 4 x 50 + 25 4 x 50 4 x 50 + 25 3 x 70 + 35 K: supplied by GE only with battery 100 4 x 70 + 35 4 x 70 4 x 70 + 35 3 x 95 + 50 F4: can be supplied by GE. 120 4 x 95 + 50 4 x 95 4 x 95 + 50 3 x 150 + 95 IMPORTANT NOTE! Th e UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6 TDS_LPS_33E_60K_M12_2GB_V010.doc Technical Data Sheets LP 33 Series 60-80-100-120 kva / S2