Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Similar documents
Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical data sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TLE Series UPS 400/500 kw With eboost Technology

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Technical data sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

EFFEKTA Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

PowerValue 11/31 T kva

TECHNICAL DATA SHEET KVA UPS Systemss

PowerScale kva Technical Specifications

Industrial PFC UPS System

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

POWERTRONIX QUASAR 5-40 KVA

PowerScale TECHNICAL SPECIFICATIONS

ConceptpowerTM Modular kVA

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

TECHNICAL SPECIFICATIONS

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

UPS Multi Sentry 10-20kVA

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

60 to 160 kva.

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

MASTERYS IP+ 10 to 80 kva

1.1 GENERAL CHARACTERISTICS

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Master Plus kva

Green Power 2.0 MASTERYS GP

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Master Plus kva

D Series: UPS UPTO - 300KVA - Three / Three Phase

Three Phase UPS Systems Range: 10 to 500kVA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Master DIALOG INDUSTRY RANGE

Technical Specification SENTINEL PRO

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

SR series. on-line

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Marketing Management Team of Europe

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

AME. Rectifier - Battery charger. Industrial applications: Key features:

MKN-DSP SERIES - THREE PHASE

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

User Manual. GE Critical Power. imagination at work. Uninterruptible Power Supply

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Master MPS kva kva 3:1 3:3 VFI TYPE

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Liebert. FP 50Z kva

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

DC POWER SUPPLY SYSTEMS

Transcription:

Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf: 02 3936 400 CELULAR: 09 9610 8549 GUAYAQUIL: Vernaza Norte Mz. 13 Solar 22 Telf: 04 2596 400 CELULAR: 09 8929 9999 CUENCA: Luis Moscoso s/n y Manuel Ignacio Ochoa Telf: 07 2854 045 CELULAR: 09 9570 0700

Model: Issued by: Approved by: LP33 Series 10 & 20 CE S6 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 25.02.2014 File name: GE_UPS_TDS_LPS_33E_10K_20K_6GB_V020 Revision: 2.0 Identification No.: Up-dating Revision Concern Date 2.0 ECN 1945 (EAC conformity) + GE Template 25.02.2014 COPYRIGHT 2014 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6

GENERAL DATA Topology VFI-SS-111, double conversion Output power kva 10 20 Output nominal power factor (lag.) 1.0 1.0 Max. active power at nominal operating conditions kw 10 20 Overall efficiency at 100% load in VFI mode % 92.0 92.4 Overall efficiency at 100% load in ECO mode % 98.2 98.6 Heat dissipation at 100% load in VFI mode, Nominal load and charged battery kw 0.87 1.65 Cooling air (25 C 30 C) m 3 /h 260 490 Audible noise level db(a) 53 53 Battery type Operating temperature range Storage temperature range Storage time of the battery without recharge at 20 C Relative humidity Max. altitude without power derating Power derating (according to EN/IEC 62040-3) Valve regulated lead-acid (VRLA) UPS: Battery: -25 C +55 C Max. 6 months 0 C 40 C (nominal 25 C) 20 C 25 C recommended Max. 95% (non-condensing) Protection degree IP 20 (IEC 60529) Standards EMC Electrostatic discharge immunity Internal protection Enclosure Transport Colour Installation External cable connections Cooling Paralleling (RPA version) (higher the temperature, shorter the storage time of the battery) 1000m 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% EN 50091 / EN/IEC 62040, CE marking EN 50091-2 / EN/IEC 62040-2 Class A 4kV contact / 8kV air discharge All live parts shrouded Metal sheet and castors Cabinet suitable for handling by forklift RAL 9003 (white) Minimum distance from the wall 5 cm Bottom left Forced from bottom side to left upper side by internal blower Up to 4 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Standard input voltage Input frequency Input power factor Input current distortion (THD) <8% Three phase, overtemperature protection Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 323V 460V (ph-n 186V 265V) 50/60Hz +/-10% (45 66 Hz) >0.98 lag. Output voltage tolerance +/- 1% Battery ripple current Battery charging characteristic Battery charging current limit <40 ma (pk-pk) IU (DIN 41773), T compensated floating voltage Selectable: 1.4A, 2.8A, 4.2A (option up to 8.4A) Input power data kva 10 20 Input power at inverter nominal load, PF=1.0 and charged battery Max. input power at inverter nominal load and max. battery charging current (default setting) kw 10.9 21.6 kw 11.6 23.1 Max. battery charging current (default setting) A 1.4 2.8 Modifications reserved Page 3/6

BATTERY Battery type Valve regulated lead-acid (VRLA) Number of blocks mounted inside the UPS cabinet (12V / 7Ah) 10kVA: 40 (2x20) 20kVA: 80 (2x2x20) Float voltage at 20 C 2 x 273 Vdc Min. discharge voltage 2 x 198 Vdc (1.65 V/cell) Recharge time 6 8 hours Automatic and manual battery test Standard Battery power data kva 10 20 DC power at full load and PF=0.8 lag. kw 8.8 17.5 Standard autonomy time at 100% load and PF=0.8 lag. Min. 10 10 Standard autonomy time at 50% load and PF=0.8 lag. Min. 26 26 Battery autonomy time at 100% load and PF=0.8 lag., only with High Rate Battery. Matching battery cabinets See optional features on page 6 INVERTER Nominal output power 10 & 20 kva at PF=0.6 1.0 lag. Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge IGBT technology Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... <2% - output voltage THD for 100% non-linear load (EN 62040) <3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 100 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection - Common input (Rectifier & Bypass) - Dual input (optional) - Thyristors (SSM - Static Switch Module) Primary components - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass Voltage limits for inverter/bypass load transfers +/- 10% Overload on bypass 200% for 2 min. and 1000% for 10 ms, non repetitive INTERFACING Potential free contacts Serial channel RS232 (on Delta 9 pin connector) EPO (Emergency Power Off) Extended Customer Interface Card (optional) Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6-4 - 28 user settable signals Standard Standard - Genset-On contact - 6 potential free alarm contacts - 1 auxiliary contact

CONTROL PANEL The Control Panel, positioned on the UPS front-top, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Synoptic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS BUILT-IN UPS OPTIONS: 1. RPA kit 2. Separate mains input (one for rectifier / one for bypass) 3. Additional battery charger COMMUNICATION: 1. Customer Interface Board 2. 3-ph SNMP/WEB plug-in adapter 3. GE Power Diagnostics 4. GE Data Protection 5. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: 1. Battery cabinets (see page 6) 2. Battery fuse box Modifications reserved Page 5/6

1320 1320 TECHNICAL DATA LP33 Series 10 & 20 LPS33_010-020_S6_UPS dimensions_ge_01 UPS rating UPS UPS without battery UPS floor loading UPS with st. shipping WEIGHT UPS with battery UPS with battery Floor loading UPS with standard shipping 10 kva 140 kg 359 kg/m 2 170 kg 270* - 370 kg 693* - 949 kg/m 2 300* - 400 kg 20 kva 150 kg 385 kg/m 2 180 kg 375 kg (14 Ah) 962 kg/m 2 (14 Ah) 405 kg (14 Ah) (*) Battery 7Ah ( ) Battery 14Ah (2x7Ah) BATTERY TABLE UPS rating Battery capacity Autonomy time WEIGHT Cabinet & Battery Floor loading Standard shipping 780 LPS33_010-020_S6_Battery cabinet_01 500 Battery cabinet 10 kva 7 Ah 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 14 Ah (2 x 7 Ah) 25 min. 21 Ah (3 x 7 Ah) 45 min. 450 kg 760 kg/m 2 480 kg 28 Ah (4 x 7 Ah) 60 min. 570 kg 962 kg/m 2 600 kg 35 Ah (5 x 7 Ah) 80 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 100 min. 810 kg 1367 kg/m 2 840 kg 14 Ah (2 x 7 Ah) 10 min. Mounted inside the UPS cabinet (see WEIGHT table) 21 Ah (3 x 7 Ah) 20 min. 450 kg 760 kg/m 2 480 kg 20 kva 28 Ah (4 x 7 Ah) 28 min. 570 kg 962 kg/m 2 600 kg 780 780 35 Ah (5 x 7 Ah) 37 min. 690 kg 1164 kg/m 2 720 kg 42 Ah (6 x 7 Ah) 45 min. 810 kg 1367 kg/m 2 840 kg Battery autonomy time at 100% load and PF=0.8 lag., only with High Power Battery. UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass (optional) kva Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections recommended by European Standards Alternatively, local standards to be respected Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 (battery) A / B /C D E K 10 3 x 25 A 3 x 25 A 3 x 20 A 3 x 25 A 5 x 4 4 x 2.5 5 x 2.5 4 x 4 20 3 x 50 A 3 x 50 A 3 x 35 A 3 x 50 A 5 x 10 4 x 6 5 x 6 4 x 10 Cable sections recommended in Switzerland (mm 2 ) F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer kva A / B /C D E K K: supplied by GE only with battery 10 5 x 6 4 x 4 5 x 4 4 x 6 F4: can be supplied by GE 20 5 x 16 4 x 10 5 x 10 4 x 16 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6