AccuPower AQU128B Installation Instructions

Similar documents
AccuPower AQU126B Installation Instructions

Installation Instructions

Installation Instructions

SMP3CTX Series Power Supply/Charger

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

AL600ULX Series. Power Supply/Charger Installation Guide

Package Contents. Mounting Hardware

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

2904 Power Supply Installation Instructions I-EA00041

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

M670/M680BD MAGNALOCK SERIES Installation Instructions

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

MODEL NUMBER: APS2448UL

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

SmartLock Accessories

Special Specification 6058 Battery Back-Up System for Signal Cabinets

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

Industrial Power Supplies

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

MODEL NUMBER: APS2012

MODEL NUMBER: APS3636VR

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Specification of Soneil Battery Charger

Product Installation Document

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

TRAC-Station BT Installation Instructions

Power Supplies DORMA PS

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

MODEL NUMBER: APS2424

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

PSU EN54-4 Power Supplies

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Solar Hybrid Inverter SP Brilliant Series

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Uninterruptible Power Supplies

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

General Precautions. Personnel Precautions

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Operating and Installation Instruction Manual

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

MODEL NUMBER: APS750. Highlights. Package Includes. Description

Uninterruptible Power Systems

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA-5KVA INVERTER / CHARGER

SE8300 Series Installation Guide 24 Vac Low Voltage

Model LA 4100 Time Delay OFF Controller

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Dry Contact Closure Interface

AWZ 110. AWZ 13,8V/1A/7Ah/LM

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

User Manual. Solar Charge Controller 3KW

ID ID. Series 19. Mechanical Products Company

Powerware Vdc Extended Battery Cabinet User s Guide.

Accessories 286 SDC SECURITY DOOR CONTROLS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

Excel Series Value Engineered Access Hardware

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Digital/Analog Amplifiers Installation Instructions

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

3 Uninterruptible Power Systems

SECURITRON POWER SUPPLIES MODELS: BPS-12-3, , 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS

Innovative Circuit Technology Ltd.

SECURITY DOOR CONTROLS

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Specification of Soneil Battery Charger

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

630 Series Power Supplies

INVERTER/CHARGERS Off-Grid Power Solutions

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

POWER CONTROL. Enclosed Power Control Centers. Prepackaged Switches. UPS Interface. Track Mount Circuit Breaker Switches

Transcription:

Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU128B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead Acid or Gel Cell Batteries* 1/16 Flat head Screw Driver 6-32x1/4 Mounting screws (QTY4) *See Battery sizing guide on page 6. Physical Size: AccuPower AQU128B Specifications Mechanical Electrical Environmental Regulatory Board: 3 15/16 x 7 3/8 x 2 3/8 Mounting: 3 1/2 x 6 13/16 Weight* AQU128B 1.5 lbs Input Voltage Operating Range 110-240VAC 47-63Hz Maximum Output Voltage 120 VA 10 Amps @ 12VDC Continuous Output Voltage: 96VA 8 Amps @ 12VDC Voltage Range: 9.7-14 VDC/ 13.75VDC typical Frequency 23 KHz Operating Temperature 0ºF to 130ºF [-17 to 54ºC] Humidity 10% to 95% RH For Indoor use Recognized Component: UL294 Listed UL603 Listed cul Listed RoHS Compliant Copyright, 2013, all rights reserved Page 1 P/N 500-30045

Overview of AQU128B Series Power Module The Securitron AccuPower AQU128B offers clean, steady and accurate power output for peak performance of access control equipment plus flexibility unmatched by any power supply/battery charger on the market today. Universal AC input with brownout tolerance to 60VAC Tolerates and protects against input voltage fluctuations. External LED AC power indicator Form C contact for AC power fail notification Dedicated voltage for battery charging even under full load Low battery disconnect prevents deep discharge of batteries PTC protection for Thermal Runaway and Current Overload Short Circuit and Reverse Battery protection - will auto restart without removing load. AQU128B and AQU128 provide a single output. The output can be divided into additional channels using any of the optional power distribution boards: PDB-4, PDB-8, PDB-8F8R, PDB-8C8R, PDB-8C1R or PDB-1R. Applications The AQU128 Series can be used with electrified access control equipment in conjunction with access control systems and fire/burglary systems including most electrified locking hardware and latches, card readers, keypads, electric strikes, controller panels, REX and motion detectors and more. Pre-Installation Survey Before installing the AQU128 Series, the mounting location should be determined and assessed for the following: Availability of AC power service Protection from vandalism and tampering Sufficient clearance for air circulation and heat dispersal CAUTION: Check with your local code inspectors to ensure your compliance with the National Electrical Code (ANSI/NFPA 70), (Canadian Electrical Code for Canada) or equivalent and any additional licensing and wiring requirements for your jurisdiction. Page 2 P/N 500-30045

A. Installing the Power Module 1. Select mounting location so that AC input conduit can be aligned to maintain separation with DC power outputs. Ensure unit is mounted with sufficient airflow to prevent heat buildup. IMPORTANT: AC Power input is not power limited. AC lines must be enclosed in approved conduit. AC Input lines must be separated by at least ¼ from Class 2 power limited output wires. Mark board mounting hole locations and drill. Install mounting screws appropriate for the mounting location, leaving enough hardware exposed to install standoffs. Install standoffs. Place starwheel on any one of the three standoff locations corresponding to a mounting location on the board that has a metal ring. Affix board to standoffs with provided metal screws. IMPORTANT: User is responsible for observing all electrical and code requirement when installing in self-provided enclosure or mounting location. B. Make Electrical Connections 1. Component Locations Page 3 P/N 500-30045

2. Understanding the Power Module Component Label AC L N PWR TROUBLE Component Name AC LED Connector AC In Terminal Block Trouble Status LED AC Status Relay Function 2-pin connector for plug-in onboard LED or remote LED harness (included). A 3-wire terminal block for AC power input. Handles 110-240 VAC. Accepts wire gauge 12AWG-18AWG. L = Line (+) N = Neutral = Ground Green LED indicating power condition of DC output. Green ON is normal. Over-voltage >28.1VDC or under-voltage/low battery < 24.2 will cause the LED to turn OFF. A 3-wire terminal block providing a SPDT-Form C contact that changes state when the AC power is interrupted. Provides 2amp@120VAC output for triggering alert notification. NO = Normally Open C = Common NC = Normally Close The switch is NO/C open when energized, C/NC closed when energized. During power loss, the switch changes state with NO/C closed and C/NC open. -DC+ Output -BAT+ DC LED DC On DC-Out Terminal Block Battery Backup Plug DC Output Power Indicator DC On/Off Switch A 2-wire terminal block for DC output voltage to devices, power distribution or accessory board. NOTE: DC output is not Class 2 power limited. A 2-pin plug for connecting battery cables for uninterruptable battery backup. Red LED indicator is lit when DC power is ON. Toggle on/off switch to enable disconnects output from power and battery. FAN + Fan Plug A 2-pin plug for Securitron optional cooling fan. 3. Make AC Power Input Connections IMPORTANT: VERIFY AC POWER IS OFF BEFORE MAKING CONNECTIONS The AQU128 has a universal transformer that accommodates 90-240 VAC input. Connect AC power wires as follows: Black/Positive = L White/Negative = N Green/Ground= G 4. Make DC Power Output Connections to Distribution or Accessory Boards Using 18 to 24 AWG wire, connect the DC OUT Positive (+) terminal to the positive (+) IN terminal on the distribution board. Connect the DC OUT Negative (-) terminal to the Negative/Common/C (-) IN terminal on the distribution board. It is recommended to pass the wires under the power module board before connecting to the accessory board in order to maintain separation from battery cables. Page 4 P/N 500-30045

5. Make DC Power Output Connections to Devices Using 10AWG to 24 AWG wire, connect the device wire run to the DC outputs. Maintain separation from battery cable placement by passing wires under power module before connecting to terminal screws. Connect the Positive wire to DC OUT Positive (+) terminal -/Negative Connect the Negative wire to DC OUT Negative (-) terminal +/Positive NOTE: Use appropriate wire gauge for the Amperage and distance of the run. For more info, see Wire Loss Calculator at http://www.securitypower.com/an2wire.html 6. Wiring for Status Monitoring Options Trouble NO C NC The diagram shows basic wiring to provide output to a control panel or local alarm for notification of over-voltage or under-voltage. AC-ON state energized the NO/C switch. Access Control System Panel The Switch changes state when voltage exceeds 14.1 VDC or falls below 12.1 VDC including voltage drop resulting from low battery power. 8. Turn on AC Power After making electric connections, turn on AC power before installing batteries. The AC LED power indicator should be lit. C. Install Batteries 1. Understanding Battery Charging and Backup Power The AQU128B is a backup battery charger with automatic fail over to battery power in case of primary AC power failure when batteries are installed and connected to the power module. The use of battery backup is optional - the unit will function without batteries installed, but no internal backup power will be available in case of AC power failure. Note: The battery circuit features automatic disconnect when the battery output falls to 9.9 VDC to prevent deep discharge and also protects the power module in case the battery is connection is reversed. For battery backup in 12VDC operation, a single 12V battery may be used, or two (2) 12V batteries may be used wired in parallel for longer run time. Backup power run time depends on the continuous output needed to support the load and the ambient temperature at the enclosure. Estimates are provided in the table below: Estimated Time (3 amp/5 minute reserve for alarm) Total Output Amps 4Ah Battery 7Ah Battery 12Ah Battery 24Ah 40Ah 6A.27 Hrs.49 Hrs.96 Hrs 2.4 Hrs 4.75 Hrs 7A.23 Hrs.42 Hrs.83 Hrs 1.9 Hrs 3.8 Hrs 8A.2 Hrs.4 Hrs.65 Hrs 1.6 Hrs 3.5 Hrs Larger batteries may be used external to the enclosure by running the battery cable through a dedicated knockout separate from the AC input and DC output. Charge current is not less than 2A @12VDC at peak load. Page 5 P/N 500-30045

2. Connecting the Battery Plug battery cable assembly into battery backup plug -BAT+. Install batteries. Mark batteries with Installed date and Replace By date according to manufacturer s battery life recommendations. Connect leads to batteries. For 12VDC operation: Connect red battery lead to the Positive (+) battery terminal. Connect black battery lead to the Negative (-) battery terminal. D. Testing 1. Test Input and Outputs AC Input: Enable AC power to input line. Confirm LED on front of enclosure is lit. DC output: If connected to load or distribution board, DC output indicator on power module will be lit. If not connected to load or distribution board, test output with Amp Meter to verify current. AC Fail Notification: Disable AC power to input line. If AC fail notification is configured, the switch will change state, triggering the notification output. Low Battery Notification: Disable AC power to input and allow batteries to run down to Low Battery Warning. Recommended Annual Maintenance Turn off AC power Battery Test AC Fail Test Check DC output voltage under battery operation. For fully charged batteries, voltage should be above 11.5V. If voltage is below this range, test batteries per battery manufacturer instructions and replace if needed. Turn off AC power. TROUBLE switch should trigger an alert upon disconnect or upon fail over to battery power. Problems with installation? Call Securitron: 1-800-MAG-LOCK For warranty information visit: www.securitron.com/en/site/securitron/about/magnacare-warranty Page 6 P/N 500-30045