Operating Manual. Type: Hydraulic Submersible Pump 3 inch WARNING! PN: H % electric shock proof. explosion proof.

Similar documents
HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

HCS14/16/18 Hydraulic Cut-off Saw. Prior to Operation. We thank you for choosing a HYCON cut-off saw.

HH10/HH10RV Hydraulic Breaker

HPD Hydraulic Post Driver

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

Rhino HBR 60 Hydraulic Breaker

Operating Manual TYROLIT ( ) A Company within the SWAROVSKI Group

HPP13D Hydraulic Powerpack

HPP09E Hydraulic Powerpack

HPP18V MULTI FLEX Hydraulic Powerpack

Rhino HPP13 Flex Hydraulic Powerpack

Rhino HPP18V FLEX Hydraulic Powerpack

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

Safety and operating instructions

LWP 2, LTP 3. Safety and operating instructions. Submersible pumps Construction Tools EOOD No f Original instructions

3 SUBMERSIBLE HYDRAPUMP INSTRUCTIONS

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

LP 9-20 E PAC. Crowder Supply Co., Inc Roslyn St., Commerce City, CO Toll Free:

50:1 Grease Pump Kits

HIGH VISCOSITY FILTER SYSTEMS

Safety instructions. Always... Never... Fire hazard! Dear customer,

Daily verifications : 1. Function and completeness of all operating and security equipment

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Slidelift. Operator`s handbook GPS 44 X1 GPS 55 X1. Lift CORP Slauson Avenue. Santa Fe Springs, CA (800)

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

LH 25 S/E HYDRAULIC BREAKER OPERATING MANUAL Serial Nos Issued 22/10-03 Revised 11/06-04

Technical Information for PVX Series Pumps

NV452 Monoblock directional control valve

PUMPS Construction Sites Mining Barges and Ships Utilities Industrial Applications Municipalities Sewage Systems

M-3025CB-AV Fuel Pump

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

PNEUMATIC PUMP Series

Operator s Manual. Sabre Crop Divider

ZDM Positive Displacement Flow Meter User Instructions

HYDRAULIC POWER PACK

ALFRA Akku-Compact Flex Handstanze Art.-Nr / Prod.-No / N art / Nº de prod

BASIC CONSTRUCTION AND FUNCTION The basic DYNASET FLOW LIMITER corresponds to the glow limiting cartridge valve, which can be fitted into different co

SYDEX / MAINTENANCE AND OPERATION MANUAL

Contents. Directional Control Valve 3 Series CV 452. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves.

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

Winch Trouble Shooting Guide

Instruction Manual. Sewage lifting station compli 300

456 Series Hydra-Lift Drum Rollers Operator s Manual for Morse Hydra-Lift Drum Rollers 456 Series

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

Trencher Dingo Attachment

SUPERIOR PERFORMANCE

F SERIES GEAR PUMP. 2 Muncie Power Products, Inc Muncie Power Products, Inc.

Instruction Manual. * We reserve the right to amend specification without prior notice.

Installation, Operation, Repair and Parts Manual

IMPORTANT NOTE The warranty will be void if the pump has been altered in any way

Active Controlled Cooling System

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SUBMERSIBLE DIRTY WATER PUMP

This picture shows CT 6,5 10 D INSTRUCTION BOOK FARMA T 9 SERVICE AND SPARE PARTS

MP18 Stacking Valve System Technical Information Manual

#9040 FUEL TANK SWEEPER

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Pneumatic High-Viscosity Filtration System Instruction Manual

SOLAR CHARGE CONTROLLER

KESSEL-Grease Separator Under sink

Operator s Manual. GreenTek Ltd Rudgate Walton Leeds LS23 7AU UK

OPERATION & MAINTENANCE MANUAL

TPHK Series Immersible Pump

GROUND ROD DRIVER 5/8 & 1 INSTRUCTIONS

This picture shows CT 6,5 10 D INSTRUCTION BOOK FARMA T 8 SERVICE AND SPARE PARTS

HALLMARK INDUSTRIES INC

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

Installation, operation and maintenance manual

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

M4 Troubleshooting 42

230V 60Hz LINE FUSES AM CLASS:

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

- the choice of. professionals...

1 MECHANICAL FUEL METER

SUBMERSIBLE WATER PUMP

TABLE OF CONTENTS GENERAL INFORMATION

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Instruction Manual. Maple 7/15 Pump. Model

Installation, Operating and Maintenance Manual

Instruction Manual. * We reserve the right to amend specification without prior notice.

L0S ANGELES COUNTY FIRE DEPARTMENT BASIC SKILLS TRAINING PROGRAM HYDRAULIC RESCUE SYSTEM

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

GPM Hydraulic Flow Meter User Manual

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

Webster S-Series Vertical Seal-Less Immersible Pumps. Rugged, Non-metallic Chemical Duty Pumps Against a Closed Valve

150 Gallon 3- Point Hitch Sprayer

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

Affordable portable filtration unit

Medium and high pressure pumps

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Hydraulic Bead Breaker Kit

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

MODEL EGA130 OWNERS MANUAL

100 Gallon Skid Sprayer

Operator s/parts Manual

Operating Instructions - Electric Pow'r-Riser Models

Transcription:

can operate in dry mode Operating Manual sanitary sewage 100% electric shock proof explosion proof Type: Hydraulic Submersible Pump 3 inch PN: H0403-3030003 operates with bio degradable oil can handle fluids up to 170 F 100% e-check free extremely quiet handles mud/sludge integrated grinding function little to no maintenance

Contents Safety Precautions 3 Important 3 Dimensions 4 Pumping Capacity 5 Technical Data 6 Oil Flow and Pressure 6 Useful Information regarding the Use of the Pump 6 Starting Instructions 7 Connection to Hydraulic Power Sources 7 Service and Maintenance 8 Oil Types 8 Warranty Terms 8 The Votex System - the physics behind it 9 Tips and tricks 10 2

Safety Precautions Read the pump and power source operating manuals prior to use. Check the oil flow to the submersible pump (see technical data). Please also refer to Pumping Capacity on page 5. A too high oil flow can cause the velocity on the pump to be too high and thereby involve a risk of defects. Make sure that the quick-release couplings are properly connected and locked. When disconnecting the couplings during operation, there is a risk of motor de-fects. Make sure that hose couplings and water hose are properly connected and locked. A fine jet of oil at pressure can penetrate the skin. It is therefore important never to use your fingers to check for oil leaks and never to hold your face close to su-spected leaks use a piece of cardboard instead. If oil has penetrated the skin, you should get medical treatment immediately. Always use approved hoses. Contact your dealer, if necessary. The operator must pay extra attention and show caution when working in difficult working areas, such as slopes and other dangerous nature of the ground. Do not reach too far with the submersible pump, but always maintain a good footing and keep your balance. In excavations there is always a risk of earth slips. The operator must always use protective goggles, earplugs, hard hat and shoes when operating the submersible pump. Inspection or cleaning of the submersible pump and change or disconnection of hoses may never be done while the pump is connected to the powerpack. Always connect hoses to the submersible pump before starting the powerpack. Be 3 sure that all couplings are tight. The pump may not be operated if the oil temperature is above 80 C (176 F). Operation at higher temperatures may result in the pump (the motor) getting warmer than normal and the operator risks getting burnt on it. To avoid all personal injury and damage to material, all repair, maintenance and service work must be carried out by authorized or properly trained persons only. Important A submersible pump not in use should always be kept in a safe and dry place. Always use hoses, couplings and spares as such recommend by HEPP. Always mount the hoses correctly, so that the pump runs the right way. If the pump runs the wrong way there is a risk of defects that are not covered by warranty. Repairs may only be carried out by experienced personnel. Make sure that all couplings are cleaned before connection. Always disconnect the hydraulic circuit before connecting or disconnecting the pump. If this is not done, there is a risk of damage to the quick release couplings or the motor or the hydraulic system getting superheated.

24 lbs Dimensions 15 imperial (US) Max. 8 gal/min 2175 PSI 3 BSP (F) 11 ¾ 8 2 /3 8 2 /3 metric 11 kg 38 cm Max. 30 l.p.m. 170 bar 30 cm 22 cm 22 cm 4

m 30 25 20 15 10 5 0 ft 100 80 65 50 30 15 0 G/min m 3 /h l/m l/s 3 inch 3 3 Pumping Capacity Performance 3 pump gallons 350 per minute maximum 5 GPM @ 2030 PSI 8 GPM @ 2030 PSI 3 3 2½ in 3 p u m p solids u p to Ø 0 44 88 132 176 220 264 308 352 396 440 484 528 572 616 660 704 748 793 837 881 imperial - gallons(us)/minute 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 0 167 333 500 667 833 1000 1167 1333 1500 1667 1833 2000 2167 2333 2500 2667 2833 3000 3167 3333 0 3 6 8 11 14 17 19 22 25 28 31 33 36 39 42 44 47 50 53 56 metric - m 3 /hour, liter/minute, liter/second Submersible pumps are perfect tools for pumping all kinds of fluids especially dirty fluids. The pumps are VORTEX pumps, which are desined specifically to pump dirty fluids, without a need for extra maintenance and without reducingthe lifetime of the pump and its components. More about The Votex System - the physics behind it on page 9. The the 3 pump solids up to ø63 mm (2½ inch). The pump can be used for many purposes and in many connections. In this respect an important feature of the pump is that it will not give any sparking. The construction of the pump allows it to run dry without damage. can operate in dry mode 5

Technical Data 3 Pump metric 3 Pump imperial (US) Weight w/o hoses: 11 kg 24.58 lbs Oil flow: 20-30 l.p.m. 5-8 gallons/minute Working pressure nominal: 120-150 bar 1,740-2,175 PSI Pressure relief valve in power source: Max. 172 bar 2,495 PSI Max. return pressure: 40 bar 580 PSI Max. oil temperature: 80 C 176 F Max. water temperature: 80 C 176 F Max. solid size: ø63 mm 2 ½ inch Max. pumping capacity: 80 m³/hour 21,133 gallons/hour Max. head: 14 m 72.17 ft Connection water hose: 3 thread internal BSP 3 thread internal BSP May run dry: Yes Yes Oil Flow and Pressure Your new submersible pump is designed for a certain oil flow, working pressure and maximum pressure. A too high oil flow and/or a too high pressure results in overload of the pump, meaning that the lifetime of your new tool will not be as expected, and that your service and repair costs will be too high. It is important to check that the pump is not supplied with an oil flow beyond its design capacity, that the working pressure is correct and that the maximum allowed pressure is not exceeded. In Technical Data you will find the technical data, and in on Connection to Hydraulic Power Sources on page 7 there is a guide to connection to hydraulic power sources and how to ensure that the submersible pump is not overloaded. Useful Information regarding the Use of the Pump The 3 pump weighs 11 kg (24.58 lbs) and pumps up to 80 m³ per hour (350 gallons/minute). Only hydraulic submersible pumps have such high performance in relation to size. The pump can also be connected to excavators and other machines. We recommend the use of a oil flow divider to protect the pump against a too high oil supply, a too high pressure and backwards rotation. Please refer to Connection to Hydraulic Power Sources on page 7. For operation in sensitive environments, you should only use biodegradable oil. operates with bio degradable oil The submersible pump is compact and light and offers high performance. 6

Starting Instructions START Mount a water hose. Connect hoses clean couplings before connection. Get a good footing before you start pumping. Lower the pump into the fluid. Make sure that the water hose is fixed. Set the power source on ON. STOP Set the power source on OFF. Connection to Hydraulic Power Sources The submersible pump can be connected to various hydraulic power sources, such as excavators, trucks, loaders, tractors etc., and of course, HEPP 2 powerpacks, the design of which ensures your new pump the absolute best working conditions. It is important that the submersible pump is not subjected to an oil flow and a work ing pressure beyond its design capability. Please refer to the ID-tag. Check the oil flow and the working pressure by means of test equipment. The test equipment should comprise a pressure gauge, a flow meter and a valve for adjust- ment of pressure. Make sure that: the oil supply is not too high the working pressure is not too high the return pressure is not too high the pressure relief valve is not set higher than 172 bar (2,495 PSI) the internal diameter of the hoses is sufficient (min. ½ ) all couplings are in order the power source is equipped with an oil filter of min. 25 Micron Hoses with too small internal diameter and/or defect couplings cause the pump to work with incorrect working pressure. Your dealer can help you check this. If the output of the power source is too high: the power source must be adjusted to correct output or you can choose to mount a oil flow divider to protect the pump against overload or you can choose one of our powerpacks. Your dealer can guide you in choosing the right powerpack. In case of doubt, please contact your dealer 7

Service and Maintenance Warranty Terms Service/Maintenance Daily Weekly Yearly Check couplings and clean carefully Check hydraulic hoses X X little to no maintenance NB. At service/repair it is important that the quick-release couplings are mounted correctly. We grant 12 months warranty from the first date of operation however, not more than 18 months from the date of delivery. The warranty applies to faults that can be related to construction and production errors. Faults caused by incorrect operation, incorrect handling, lack of maintenance or the like, will not be accepted as warranty. The warranty covers the parts necessary for repair and the suggested average time needed for repair. For further warranty details, please contact your local dealer. operates with bio degradable oil Oil Types The submersible pump uses standard hydraulic oil, i.e. all types of mineral oil and biodegradable oil, which comply with the following values: Recommended viscosity: Permitted viscosity: 20-40 cst 15-1000 cst Viscosity index: Min. 100 Temperature area: -20 to +70 C (-4 to + 158 F) If using biodegradable oil, we recommend the use of oil based on rape. Other types of oil can be aggressive towards parts of the pump. 8

The Votex System - the physics behind it possible repairs can be done on site. Minimizes costs Little to NO maintenance. minimizes costs and downtime weights from 16 to 59 lbs minimizes transport and set-up. Easy handling max. efficiency Can operate in dry mode for extensive periods. Safe against misuse. Simple handling eliminates costs Handles solids from 1½ up to 3 inch without performance reduction. solids 1½- 3 in Drive wheel without "wings" generates eddy current in the pump Eddy current pushes solids to the edge of the pump. Dirty water with abrasive components hardly comes into contact with impeller. This significantly reduces wear and maintenance costs. Dark blue = high proportion of abrasive substances Medium blue = mean proportion of abrasive substances Light blue = low proportion of abrasive substances 9

Tips and tricks to maximize the performace of the pump and to minimize the cost of pumping please note: Use. Minimize the pump height. If possible get a negative height. Place the outlet below the inlet of the hose. outlet and the inlet of the hose at the same height. better performance low costs outlet of the hose at the highest point poorest performance highest costs Place the outlet of the hose below its inlet you get the best performance possible. After the hose is filled with water this system keeps on pumping also if you stop the pump. The water is running trough the pump without any further external energy. Lower the outlet of the hose for a better peformance. outlet of the hose above its inlet and below the highest point. good performance high costs outlet is below the inlet of the hose. best performance lowest costs Using further gets a better perfomance of the pump 10

11