AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

Similar documents
ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

APD-ULJ250. Standby Power

APD-NG400. NG Standby Power

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

70 KW / 90 KVA POWERED by

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

57 KW / 71 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

60 KW / 75 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

28 KW / 28 KVA POWERED by

18 KW / 18 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

2000 KW / 2500 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

600 KW / 750 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

300 KW / 375 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

55 KW / 70 KVA POWERED by

130 KW / 165 KVA POWERED by

WPS60/S EP Series. Features:

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

130 KW / 165 KVA POWERED by

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

80 KW / 100 KVA POWERED by

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

30 KW / 40 KVA POWERED by

204 KW / 254 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1000 KW / 1250 KVA POWERED by

20 KW / 25 KVA LIQUID COOLED POWERED by

WPS100/S EP Series. Features:

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

WPS20/S EP Series. Features:

64 KW / 80 KVA POWERED by

WPS350/S EP Series. Features:

Standby Amper VOLTAGE

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

640 KW / 800 KVA POWERED by

WPS150/S EP Series. Features:

Standby Amper VOLTAGE

16 KW / 20 KVA POWERED by

500 KW / 625 KVA POWERED by

45 KW / 55 KVA POWERED by

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1800 KW / 2250 KVA POWERED by

WPS250/S EP Series. Features:

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Standby Amper VOLTAGE

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

RENTAL DIESEL GENERATOR SET

700 KVA / 550 KW POWERED by

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Model NA 2 L

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

GMS100C/S EC Series. Features:

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

19 KW / 24 KVA POWERED by

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Rating Definitions and Conditions

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Model MP150 W W

TPD2250H6.3 TECHNICAL DATA

Rating Definitions and Conditions

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Rating Definitions and Conditions

Rating Definitions and Conditions

PGDLS352KW 380/ / / / / / / / /

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

PGDLS / / / / / / / / /

Diesel Generator Set S3.8 Series Engine

GMS200C/S EC Series. Features:

GMS350C/S EC Series. Features:

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Transcription:

AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main production plants and over 15 branch offices worldwide. General Characteristics Model Name Frequency / PF 60Hz, 1800 rpm, 0.8pf Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford Control Panel Model DSE 6020 Base Frame / Enclosure AKSA AK21 Genset Rating 60Hz, 1800rpm, 0.8pf Engine Alternator Voltage Standby Power Prime Power Standby Current PI144K 480 / 277V 59kVA 53kVA 70 A 1103A-33TG1 UCI224D 380 / 222V 59kVA 53kVA 89 A UCI224D 220 / 127V 59kVA 53kVA 154 A UCI224D 208 / 120V 59kVA 53kVA 163 A Stand-by Power (Maximum): Power available at variable load in the event of main power network failure. No over load is permitted. Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours of operation. The above ratings represent the engine performance capabilities to conditions specified in accordance with ISO 8528/5 & ISO3046. Derating may be required for conditions outside of the test conditions. Codes & Standards The Generator set is designed and manufactured in a facility certified to ISO9001 standards. The Generator set is designed and manufactured in a facility certified to ISO14001:2015 standards. AKSA Power Generation provides single source responsibility for the generator set & accessories. The generator set, with its components, are prototype tested and production tested

Engine Data Electric System Perkins Engine Cranking Motor 12V Model 1103A-33TG1 Engine Battery Charge System Negative Ground Displacement & Cylinders Engine Speed 3.3 L / 3 Cylinders 1800rpm Battery Qty, Rating, CCA 1 x 54Ah Engine Standby Power 53.9 Kw Cooling System Engine Prime Power 48.8 kw Radiator Face Area 0.276 m 2 Aspiration Turbocharged Fan Number of Plates/Material 7 / Composite Compression Ratio 17.25 : 1 Bore / Stroke 105 mm / 127 mm Break Mean Effective Pressure 1124 kpa Engine Coolant Flow 151 l/min Total System Capacity Max Top Tank Temperature Thermostat Range 10.2 L 110 C 82 93 C Combustion Air Flow 3.9 m 3 /min Exhaust System Exhaust Gas Flow 9.5 m 3 /min Maximum Back Pressure 10 kpa Exhaust Gas Temperature 551 C Exhaust Outlet Size 56 mm Overall Thermal Efficiency 39.1 % Speed Variation at Constant Load Fuel System ±0.75 % Lubrication System Total System Capacity Minimum Capacity 8.3 L 6.2 L Type of Injection Direct Injection Max Oil Temp 125 C Fuel Injection Pump Rotary Oil Pressure relief valve opens 415 470 kpa Nozzle Opening Pressure 29 Mpa Oil Consumption at full load as a % of fuel consumption 0.15 % Fuel Lift Pump Flow/hour 120-150 liters/hr Energy Balance Fuel Consumption Energy in fuel 142 kw Standby Power (110%) 14.3 L/h Energy in power output gross 55.6 kw Prime Power (100%) 12.9 L/h Energy to cooling fan 1.7 kw Prime Power (75%) 9.9 L/h Energy to coolant and oil 34 kw Prime Power (50%) 7.1 L/h Energy to exhaust 43 kw

Alternator Data Controller Data Stamford DSE Standards BS EN 60034 Model 6020 Control System Self Excited Type Auto Mains Failure Control A.V.R. AS480 / SX460 Voltage Regulation ± 1 % Insulation System Class H Controller Features & Benefits Microprocessor controlled Protection IP21 / IP23 License free PC Software Rated Power Factor 0.8 IP65 rating offers increased resistance to water ingress Stator Winding Winding Pitch Double Layer Concentric Two Thirds Front Panel Editing Event log Winding Leads 12 Telephone Interference THF < 2 % Waveform Distortion No Load < 1.5 % Back-lit icon LCD display LED and LCD alarm indication Power save mode Maximum Over speed 2250 rev/min PC and front panel configuration Battery Charger & Electrical System Data AKSA Model SmartGen BAC06A Input Voltage 100V ~ 250V AC Output Voltage / Current 13,8V DC / 6A Jacket Water Heater Data Configurable timers and alarms Alternative configuration Three phase generator monitoring Current monitoring and protection Power monitoring (kw, kva, kvar) Reverse power (kw & kvar) protection Three phase utility monitoring AKSA Test feature Model HTR1000W 100-120F Battery voltage monitoring Input Voltage Power 1 ph, Based on gen voltage 1000W Hours counter Comprehensive warning or shutdown on fault condition

Enclosure Features Heavy Duty Steel Structure E-Stop on Enclosure Control Panel Eliminated from Engine Vibrations Plastic Covered Corrosion Resistant Locks & Hinges Internally Mounted Exhaust System with Rain Cap Coolant Fill Cap Enclosure Top Lifting Hooks Base Fuel Tank Easy Access for Maintenance Sound Absorb High Density Foam Open Skid Gen-Set Dimensions Length 1780 mm Width 950 mm Height 1206 mm Dry Weight 850 kg Tank Capacity 100 L Enclosed Gen-Set Dimensions Length 2466 mm Width 1010 mm Height 1461 mm Dry Weight 1030 kg Tank Capacity 100 L Sound Pressure @ 7 meters 70 db(a)

Standard Features & Accessories Heavy Duty Steel Base Frame Integral Fuel Tank, Single Wall Fuel Drain Plug Engine Jacket Water Heater Battery and Battery Rack Battery Charger Radiator fill cap on enclosure Anti Vibration Pads between Engine/Alternator & Base Frame Residential Grade Silencer Inside Enclosure Industrial Grade Silencer Set for Open Skid Sets Sound Absorb Foam for Enclosure Air Inlet & Outlet Rodent Guards Oil Drain Valve Coolant Drain Valve Flex Fuel Lines Air Filter Restriction Gauge Engine Manifold Cover Turbocharger Cover Protection Covers for Rotating Parts Exhaust Insulation Cover Operations Manual 24 Months / 2000 hours Limited Standby Warranty Optional Accessories Main Line CB (3 / 4 Poles) EBS / PMG Anti-condensation Heater Single wall fuel tank 24hours capacity Double wall fuel tank Fuel Level Display & Alarm on Controller Low / High Fuel Alarms Fuel Water Separator Filter Auto Fuel Fill Control System Oil Temperature Display on Controller Manual Speed Adjust Rheostat Manual Voltage Adjust Rheostat Remote Annunciator Panel Remote Control & Monitoring Panel Advanced SMS Messaging Control Panel Heater Battery Disconnect Switch Battery Heater 10A Battery Charger Battery Charge Ammeter Tool Kit for Maintenance Power Plug Outlet Kit Automatic Transfer Panel (ATS) Contactor Design Automatic Transfer Panel (ATS) Changeover Design Aksa Power Generation USA 371 Exchange Street, West Monroe, LA 71292 T: + 1 318 8558377 sales@aksausa.com Aksa Power Generation USA & LATAM a member of Aksa Power Generation LATAM 12320 NW 116 th Street, Miami, FL 33178 T: + 1 786 4936857 sales@aksausa.com