PNEUMATIC MANIFOLD VALVE PMV08

Similar documents
AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

Solenoid Valve Output Module IC693MDL760 Product Description

Operating Manual for the RE-19 Multi-pin Valve Terminal

Adjustable Differential Relay A1

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Installation Manual For ISL98, ISL03, ISL07, ISC07

TECHNICAL MANUAL ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FOR

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

One-Gun Add-On Kit For Smart-Coat Controllers

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

the systems people Owners Manual VCMS Switch Panel System Model VCMS-SP34

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

INTAKE MANIFOLD COLLECTOR. 1. Electric throttle control actuator 2. Gasket 3. Vacuum hose

ROLL UP DOOR TRADITIONAL HANDLE BAR INSTALLATION INSTRUCTIONS

Genesis Series Valves Parts List / Service Instructions

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Series AN /Series AMC

Installation Instructions for. For Use When Converting Model (V)M42(B) Vented Decorative Fireplace. Fold Bi-Fold Door After Releasing

IDEAL Stripmaster Model 950 Wire Stripper #45-950

APS SERIES. Air Pump Shut Off Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS

Series 581 ISO Pneumatic Directional Control Valves

SERVICE PROCEDURES FOR CLUTCH HYDRAULIC UNITS

SBM TECHNOLOGY Cooling / Air Recovery Valve

Vacuum Release Valve with Restrictor

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Pantera Electronics LED Taillight Installation Manual

ILCS EDGE System Installation Manual

Identify and Assemble the Pneumatic Components

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Pneumatic Connector, Tubing, and Accessory Catalog

Pantera Electronics LED Taillight Conversion Installation Manual

Protection Systems. 3-Way Directional Ball Valve P/Ns: X and X. A UTC Fire & Security Company FEATURES

REPAIR PROCEDURES MANUAL

Protection Systems. 3-Way Directional Valve P/N: XX-00X. A UTC Fire & Security Company FEATURES

Type 2000 Transducer Product Instructions

ARGONITE Fire Protection Systems

Model INT July 2010

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Pressure Sensor No Series

Model APS-101N Installation Manual

Coolant Refill - Installation

ILCS EDGE Jr EDP Installation Manual

Easytork Vane Actuator IOM

AIR DRIVEN TUBE CLEANER

ASSEMBLY INSTRUCTIONS

SUPER 30 AUTO EJECT -AE

A REPAIR KIT PART NUMBER IS AVAILABLE AND CONTAINS ALL THE PARTS NORMALLY REPLACED DURING A STANDARD MAINTENANCE REPAIR.

Edelbrock Victor II Intake Manifold. For Chrysler 5.7L (Eagle), 6.1L and 6.4L Gen III HEMI Engines Part #7179

Solenoid Valve Island Type 3965

3 Phase Smart Controller

Introduction Safety precautions for connections... 3 Series 3700 documentation... 4 Model 3732 overview... 5 Accessories...

ISSUER: WRC 10/29/10 ENGINEERING: PROD/MTL: QA APPROVAL: REVISION HISTORY

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

INSTRUCTION MANUAL ENGINE IDLER MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.


771 XS BALL VALVE WITH ADA PNEUMATIC ACTUATOR

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

REC-11+ REMOTE RECEIVER UNIT

OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

EVP SERIES PROPORTIONAL CONTROL VALVES

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

10 mm solenoid valves on manifold with multiconnection D-SUB

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

8/6/2013 LX-30 MACHINES: COPYRIGHT 6/10/10 ALL RIGHTS RESERVED

715 XS BALL VALVE + ADA PNEUMATIC ACTUATOR

Dispensing. Monitoring Systems. Loctite Fluorescence Detector, Item 98083

Fuel Charging and Controls

Pneumatic Actuators Quarter Turn Rack & Pinion Double Acting and Spring Return

RCL-600A PRODUCT SUPPORT MANUAL. Y Rev. B. Remote Control Searchlight with Joystick Remote Control Panel. Product No.

DKD/CP DN PVC-U. Direct action pneumatically actuated 2-way diaphragm valve

Edelbrock Victor II Intake Manifold. For Chrysler 5.7L (Eagle) and 6.1L Gen III HEMI Engines Part #7179

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Banks Techni-Cooler Intercooler Assembly Ford Power Stroke 6.0L Turbo-Diesel F250/F350/F450/F550 Trucks & Excursions

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

Illustrated Catalog of Components

Installation, Operation and Maintenance Manual for Flame Check

LIMIT SWITCH Prism - PI

EI, EIO INTRINSICALLY SAFE VALVES

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

BEAMER Tilt Beam Sensor

The New Filter Valve Technology

Instructions for repairing the F-Body Hatch Pull-Down Unit By Lon Salgren (ls90rs)

1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST

TECHNICAL INSTRUCTIONS

Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22

COIL OPTIONS Besides coils ranging from volts AC & DC, the construction varieties are: non-molded, molded, high temperature, potted coil & ho

SloanLED THINLED. Constant Current. Installation Guide

SST & PRO II Media Filtration Systems Installation and Operation Instructions

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

Pneumatic Division North America Richland, MI 49083

Overview. Bosch Rexroth Corp /11 Aluminum Framing. Linear Motion and Assembly Technologies. Section 8: Air Supply Elements

Banks Brake. with installation instructions EXHAUST BRAKE SYSTEM Dodge 5.9L Cummins (12-valve) Turbo-Diesel Pickups with Manual Transmissions

DPX - DPAX butterfly valve technical description

HIPSTER'S ALUMINUM POWERGLIDE TRANSBRAKE (P/N: 12748A) CAUTION

PNEUMATICALLY ACTUATED 2-WAY

Note: the numbers in parenthesis refer to the components in the exploded view of page 3 for UT-0 thru UT-6.5 and page 4 for UT-7 and UT-8.

INSTALLATION INSTRUCTIONS FOR PCDE-36VA CONVERSION KIT

Transcription:

Huron Net Works PNEUMATIC MANIFOLD VALVE PMV08 (Rev 1.00) Operating Manual P/N: 2505005 Rev 1.00 771 Airport Blvd., Suite 2 Page 1 of 8

Introduction The PMV08 Pneumatic Manifold Valve module is designed to eliminate any potential of fire or explosion hazard from the manufacturing environment. The module is intended to be located outside of and away from any hazardous areas. Only the pneumatic output of the module should be used inside of a hazardous environment. Also, the electrical and pneumatic connections to the manifold identified in this PMV08 Operating Manual should be strictly adhered to insure safe operation. Before installing the PMV08 module: READ AND UNDERSTAND THE CONTENTS OF THIS OPERATING MANUAL BEFORE INSTALLING OR OPERATING THE EQUIPMENT CONTROLLED BY THIS MODULE The PMV08 has been designed and manufactured without silicone or any other potential contaminates. The manifold consists of PVC (Poly-Vinyl Chloride) and two-part epoxy plastics. The solenoid consists of aluminum valves and body with polymeric seals. No lubricants are used anywhere within the pneumatic system. System Overview The PMV08 module consists of three major sub-systems. The electronic PCB (Printed Circuit Board), the solenoid valves, and the pneumatic manifold. The electronic PCB is controlled with a 24-volt input from an external controller. The 24-volts actuates the solenoid through control circuits on the PCB. A PCB mounted LED (light emitting diode) is used to identify when the solenoid is actuated and that circuit may be pressurized. An integral push button switch is used to manually actuate the solenoid for electrical testing and system checks. An additional LED is provided to define when an external MANUAL ON command is supplied. The solenoid controls the pressure supplied to the PMV08 through the manifold to the Apply port and exhausts the apply pressure when the electrical command is removed. This particular solenoid is a normally closed valve. Pilot pressure control of the slave valve in the solenoid is obtained internally from the supply port. A minimum supply pressure is required to control the operation of the solenoid. The pneumatic manifold consists of several layers of PVC Type I material. The PVC is machined with several ports and channels to direct the externally supplied air pressure. The ports are: 771 Airport Blvd., Suite 2 Page 2 of 8

Supply The Supply port accepts externally supplied pre-conditioned air as required by the system to be controlled. The only requirement of the PMV08 is air that is clean and free of foreign particles. The PMV08 module does not require a dry air to function. Apply Directed output from the Supply port to control the manufacturing system. The Apply port is normally connected to the Exhaust port. Only a commanded signal to the solenoid will apply a pressure to this port. Exhaust - Port used to release pressure from the controlled manufacturing system. While a backpressure can be maintained at the Exhaust port, this is not recommended. Without an electrical signal applied to the solenoid the Apply port is connected to the Exhaust port. Manifold Solenoid Printed Circuit Board PMV08 Module Systems 771 Airport Blvd., Suite 2 Page 3 of 8

Exhaust Apply Supply PMV08 Pneumatic Ports Installation The PMV08 module is designed to be a rack mount. Any rack similar to the Schroff Subracks europacpro can be used to mount the module. The procedure for installation of the PMV08 is as follows: 1. Install the pressure transfer gasket into the ports at the rear of the PMV08 module. (GASKET IS NOT PROVIDED WITH THE MODULE) 2. Lubricate the Outside Diameter of the exposed gasket transfer tubes with an approved lubricant. 771 Airport Blvd., Suite 2 Page 4 of 8

Extreme caution should be used in the selection of a lubricant to insure the manufacturing system does not become contaminated. 3. Insure the rack mounted mating electrical connector and pressure block is mounted to the rack at a total width of 14T. (ELECTRICAL CONNECTOR AND PRESSURE BLOCK ARE NOT PROVIDED) 4. Align upper and lower guide rails with the left side of the electrical connector. (GUIDE RAILS MUST BE PURCHASED AS ACCESSORIES TO THE RACK) 5. Slide PMV08 module into the rack using the PCB in the guide rails for alignment. 6. Push module firmly into place until gasket and electrical connector are completely seated. 7. Screw the four retaining screws (included with the PMV08 module) into the rack until seated. NOTE: A slot is provided at the bottom of the PMV08 module to allow easy removal for maintenance or repair. Insure that the retaining screws are fully removed from the rack before prying on the module at the slot. Damage to the module will occur if the screws are not removed before disassembly. Electrical Connection MANUAL ON LED Push Button Switch and LED 2 Pin Solenoid Connector 32 Pin Connector PMV08 Printed Circuit Board 771 Airport Blvd., Suite 2 Page 5 of 8

The PCB interfaces consist of a 32-pin connector, 8-2 pin solenoid connectors, and 8 push button manual switches with integral LED. Control of the PMV08 is provided through a 32 pin Harding 6921 male connector mounted to the PCB. Connection to the rack mounted female connector is accomplished when the module is inserted and seated into the rack. The electrical connector pin assignments are as follows: Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Manual On Manual On Manual On GND GND 32 Pin PCB Connector Electrical Pin Assignments Control of each of the eight solenoids is provided through a two-pin connector integrated into the PCB. The connection with the solenoid is completed during the assembly of the PCB to the module and secured with the four PCB mounting screws. The push button manual switches are accessible from the front panel. Depressing a button switch activates that particular solenoid. Simultaneously, the LED is illuminated. The LED is also illuminated when an external command is applied to the solenoid. An additional LED is used to indicate the MANUAL ON is applied through the 32- pin PCB connector. 771 Airport Blvd., Suite 2 Page 6 of 8

Pneumatic Control Eight SMC SYJ314 solenoids mounted to the manifold provide pneumatic control. The solenoid are Normally Closed to insure that the Apply circuit is connected to the Exhaust circuit until the electrical command is applied to the solenoid. With a command signal applied the Supply pressure is applied to the Apply circuit. Solenoids Manifold Transfer Ports PMV08 Assembly Showing Solenoids and Pneumatic Ports 771 Airport Blvd., Suite 2 Page 7 of 8

The transfer ports are designed to match an existing gasket used in paint booth systems. Unlike the existing control module the PMV08 module uses internal pilot pressure to control the solenoid. Therefore, the external pilot pressure is not required, or used. These are identified in the drawing as E1, and P10. The A19 is not used with either of the control modules. E P A 1 10 19 2 11 20 3 12 21 4 13 22 5 14 23 6 15 24 7 16 25 8 17 26 9 18 27 Gasket Locator Hole Pneumatic Transfer Port Identification An additional hole is used for locating the transfer gasket. While this hole does not affect the operation of the system it does insure that the transfer tubes are in the same location. Therefore, the lubricated surface of the gasket transfer tubes will always be inserted into the pressure block mounted to the sub-rack. This will insure that the gasket will stay with the module when separated. Maintenance No maintenance is required for any of the components in the PMV08. However, in the unlikely event that one of the components requires servicing you should contact Huron Net Works for the replacement part. This will insure the PMV08 will continue to operate at peak performance. 771 Airport Blvd., Suite 2 Page 8 of 8