Optional Control Panel POWER

Similar documents
K12. Optional Control Panel POWER K12

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K20UM POWER 240 MONO-BI

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional control panel POWER. Voltage

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

K17M POWER 240 MONO 230 MONO 220 MONO

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

ENGINE CHARACTERISTICS

K26M POWER 240 MONO 230 MONO 220 MONO

KV550C2. Optional control panel POWER

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

GZ25 POWER. Fuel System 50 Hz:

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

GZ50 POWER. Fuel System 50 Hz:

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

GZ40 POWER. Fuel System 50 Hz:

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

KM2500. Engine type Alternator type Performance class

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

USP&E Cummins Series Diesel Generator Set

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

USP&E Cummins Series Diesel Generator Set

USP&ECummins Series Diesel Generator Set

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

USP&E Cummins Series Diesel Generator Set

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

USP&E Cummins Series Diesel Generator Set

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

WPS20/S EP Series. Features:

Transcription:

Engine ref. Alternator ref. Performance class KDW1003 AT00260T G2 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel Optional control panel Optional Control Panel APM303 TELYS Basic terminal block POWER Voltage ESP PRP kwe kva kwe kva Standby Amps DESCRIPTIVE Mechanic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for core temperature of 48/50 C max with mechanical fan Protective grille for fan and rotating parts (CE option) 9 db(a) silencer supplied separately Charger DC starting battery with electrolyte 12 V charge alternator and starter Delivered with oil and coolant -30 C Manual for use and installation POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 100 kpa (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. 240 TRI 7,1 8,9 6,5 8,1 21 230 TRI 7,1 8,9 6,5 8,1 22 220 TRI 7,1 8,9 6,5 8,1 23 220/127 7,1 8,9 6,5 8,1 23 415/240 7,1 8,9 6,5 8,1 12 400/230 7,1 8,9 6,5 8,1 13 380/220 7,1 8,9 6,5 8,1 14 DIMENSIONS COMPACT VERSION Length (mm) 1220 Width (mm) 700 Height (mm) 920 Dry weight (kg) 290 Tank capacity (L) 50 DIMENSIONS SOUNDPROOFED VERSION Commercial reference of the enclosure M125 Length (mm) 1482 Width (mm) 760 Height (mm) 1030 Dry weight (kg) 390 Tank capacity (L) 50 Acoustic pressure level @1m in db(a) 67 Sound power level guaranteed (Lwa) 83 Acoustic pressure level @7m in db(a) 54

ENGINE CHARACTERISTICS GENERAL ENGINE DATA Engine brand Engine ref. Air inlet system Cylinders configuration KOHLER DIESEL KDW1003 Athmo L EXHAUST Exhaust gas temperature @ ESP 50Hz ( C) 440 Exhaust gas flow @ ESP 50 Hz (L/s) 30,70 Max. exhaust back pressure (mm H2O) 750 Number of cylinders 3 Displacement (L) 1,03 Charge Air coolant Bore (mm) x Stroke (mm) 75,00 x 77,60 Compression ratio 22,8 : 1 Speed (RPM) 1500 Pistons speed (m/s) 3,88 Maximum stand-by power at rated RPM (kw) 8,50 Frequency regulation, steady state +/- 2.5% BMEP (bar) 5,99 Governor type COOLING SYSTEM Mechanical FUEL Consumption @ 110% load (L/h) 2,72 Consumption @ 100% load (L/h) 2,50 Consumption @ 75% load (L/h) 1,90 Consumption @ 50% load (L/h) 1,26 Maximum fuel pump flow (L/h) 50,00 OIL Oil capacity (L) 2,40 Min. oil pressure (bar) 1,40 Max. oil pressure (bar) 7,00 Oil consumption 100% load (L/h) Oil sump capacity (L) 2,3 Radiator & Engine capacity (L) 4,50 Max water temperature ( C) 110,00 Outlet water temperature ( C) Fan power (kw) 0,15 Fan air flow w/o restriction (m3/s) 0,85 Available restriction on air flow (mm H2O) Type of coolant Glycol-Ethylene Thermostat modulating range HT ( C) 80 HEAT BALANCE Heat rejection to exhaust (kw) 9 Radiated heat to ambiant (kw) 1,30 Haet rejection to coolant (kw) 8,50 AIR INTAKE Max. intake restriction (mm H2O) 200 Intake air flow (L/s) 12,80 EMISSIONS Emission PM (g/kw.h) Emission CO (g/kw.h) Emission HC+NOx (g/kwh) Emission HC (mg/nm3) 5% O2

ALTERNATOR CHARACTERISTICS GENERAL DATA Alternator ref. Number of Phase Power factor (Cos Phi) 0,8 AT00260T Three phase Altitude (m) 0 to 1000 Overspeed (rpm) 2250 Number of pole 4 Capacity for maintaining short circuit at 3 ln for 10 s Yes Insulation class H T class (H/125 ), continuous 40 C H / 125 K T class, standby 27 C H / 163 K AVR Regulation Yes Total Harmonic Distortion in no-load DHT 2,7 Total Harmonic Distortion, on load DHT 2,8 Wave form : NEMA=TIF <45 Wave form : CEI=FHT <2 Number of bearing 1 Coupling Direct Voltage regulation at established rating (+/- %) 1,00 Recovery time (Delta U = 20% 200 transcient) (ms) Indication of protection IP 23 Technology Without collar or brush W b OTHER DATA Continuous Nominal Rating 40 C (kva) 8,0 Standby Rating 27 C (kva) 8,8 Efficiencies 100% of load 83,7 Air flow (m3/s) 0,058 Short circuit ratio (Kcc) 0,800 Direct axis synchro reactance unsaturated (Xd) 186,6 Quadra axis synchro reactance unsaturated (Xq) 61,6 Open circuit time constant (T'do) (ms) 730,00 Direct axis transcient reactance saturated (X'd) 14,3 Short circuit transcient time constant (T'd) (ms) 17,000 Direct axis subtranscient reactance saturated (X''d) 10,3 Subtranscient time constant (T"d) (ms) 11,000 Quadra axis subtranscient reactance saturated (X"q) 56,00 Subtranscient time constant (T"q) (ms) 8,0 Zero sequence reactance unsaturated (Xo) 5,80 Negative sequence reactance saturated (X2) 14,10 Armature time constant (Ta) (ms) 12,000 No load excitation current (io) (A) 0,29 Full load excitation current (ic) (A) 0,80 Full load excitation voltage (uc) (V) 12,6 Engine start (Delta U = 20% perm. or 50% trans.) (kva) 26,00 Transcient dip (4/4 load) - PF : 0,8 AR 14,17 No load losses (W) 285,00 Heat rejection (W) 1246,00 Unbalanced load acceptance ratio 100

CONTROL PANEL APM303, comprehensive and simple TELYS, ergonomic and user-friendly The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features: Measurements: phase-to-neutral and phase-to-phase voltages, fuel level (In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels) Supervision: Modbus RTU communication on RS485 Reports: (In option : 2 configurable reports) Safety features: Overspeed, oil pressure,coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power P<66kVA) Traceability: Stack of 12 stored events For further information, please refer to the data sheet for the APM303. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. The TELYS offers the following functions: Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. For more information on the product and its options, please refer to the sales documentation.

Basic terminal block The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button, customer connection terminal block, CE.