Optional control panel POWER. Voltage

Similar documents
D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

K12. Optional Control Panel POWER K12

Optional Control Panel POWER

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV550C2. Optional control panel POWER

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K20UM POWER 240 MONO-BI

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

K17M POWER 240 MONO 230 MONO 220 MONO

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

K26M POWER 240 MONO 230 MONO 220 MONO

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

ENGINE CHARACTERISTICS

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM2500. Engine type Alternator type Performance class

GZ25 POWER. Fuel System 50 Hz:

GZ50 POWER. Fuel System 50 Hz:

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

GZ40 POWER. Fuel System 50 Hz:

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

USP&E Cummins Series Diesel Generator Set

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

USP&E Cummins Series Diesel Generator Set

USP&ECummins Series Diesel Generator Set

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

WPS20/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

USP&E Cummins Series Diesel Generator Set

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

USP&E Cummins Series Diesel Generator Set

WPS60/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Low Voltage Alternators - 4 pole LSA 44.3

WPS350/S EP Series. Features:

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Transcription:

Engine ref. P126TI Alternator ref. AT0T Performance class G3 GENERAL CHARACTERISTICS Frequency (Hz) 50 Voltage (V) 400/230 Standard Control Panel APM303 Optional control panel TELYS Optional Control Panel APM802 Basic terminal block Optional control panel POWER Voltage DESCRIPTIVE Electronic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for core temperature of 48/50 C max with mechanical fan Protective grille for fan and rotating parts (CE option) ESP PRP Standby Amps kwe kva kwe kva /115 794 240 TRI 213 266 193 242 640 230 TRI 690 TRI 722 415/240 213 266 193 242 370 400/230 397 380/ 418 9 db(a) silencer supplied separately Charger DC starting battery with electrolyte 24 V charge alternator and starter Delivered with oil and coolant -30 C Manual for use and installation POWER DEFINITION DIMENSIONS COMPACT VERSION 2900 1300 1670 2310 390 DIMENSIONS SOUNDPROOFED VERSION M227 4004 2145 3160 390 ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions. You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. 73 PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 100 kpa (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ENGINE CHARACTERISTICS

GENERAL ENGINE DATA EXHAUST Engine brand DOOSAN Exhaust gas temperature @ ESP 50Hz ( C) 560 Engine ref. P126TI Exhaust gas flow @ ESP 50 Hz (L/s) 715,00 Air inlet system Turbo Max. exhaust back pressure (mm H2O) 600 Cylinders configuration L Number of cylinders 6 FUEL Displacement (L) 11,05 Consumption @ 110% load (L/h) 66,20 Charge Air coolant Air/Air DC Consumption @ 100% load (L/h) 58,10 Bore (mm) x Stroke (mm) 123,00 x 155,00 Consumption @ 75% load (L/h) 43,60 Compression ratio 17 : 1 Consumption @ 50% load (L/h) 30,00 Speed (RPM) 1500 Maximum fuel pump flow (L/h) 270,00 Pistons speed (m/s) 7,75 Maximum stand-by power at rated 272,00 RPM (kw) Frequency regulation, steady state +/- 0.5% OIL Oil capacity (L) 25,00 BMEP (bar) 17,45 Min. oil pressure (bar) 0,50 Governor type Electronic Max. oil pressure (bar) 10,00 Oil consumption 100% load (L/h) 0,063 Oil sump capacity (L) 23,0 COOLING SYSTEM Radiator & Engine capacity (L) 50,50 Max water temperature ( C) 103,00 Outlet water temperature ( C) HEAT BALANCE Heat rejection to exhaust (kw) 254 Fan power (kw) 7,00 Radiated heat to ambiant (kw) 35,20 Fan air flow w/o restriction (m3/s) Available restriction on air flow (mm H2O) Type of coolant 5,00 Haet rejection to coolant (kw) 107,00 76,00 Glycol-Ethylene Thermostat modulating range HT ( C) 71-85 AIR INTAKE Max. intake restriction (mm H2O) Intake air flow (L/s) 635 273,00 EMISSIONS Emission PM (g/kw.h) 0,14 Emission CO (g/kw.h) 0,11 Emission HC+NOx (g/kwh) Emission HC (mg/nm3) 5% O2

ALTERNATOR CHARACTERISTICS GENERAL DATA OTHER DATA Alternator ref. AT0T Continuous Nominal Rating 40 C (kva),0 Number of Phase Three phase Power factor (Cos Phi) 0,8 Standby Rating 27 C (kva) Efficiencies 100% of load,0 93,4 Altitude (m) 0 to 1000 Air flow (m3/s) 0,533 Overspeed (rpm) 2 Short circuit ratio (Kcc) 0,440 Number of pole Capacity for maintaining short circuit at 3 ln for 10 s Insulation class 4 Direct axis synchro reactance unsaturated (Xd) 214,2 Yes Quadra axis synchro reactance unsaturated (Xq) 121,1 Open circuit time constant (T'do) (ms) 1300,00 T class (H/125 ), continuous 40 C H / 125 K Direct axis transcient reactance saturated (X'd) 12,0 T class, standby 27 C H / 163 K 85,000 AVR Regulation Total Harmonic Distortion in no-load DHT Total Harmonic Distortion, on load DHT Wave form : NEMA=TIF Yes Short circuit transcient time constant (T'd) (ms) Direct axis subtranscient reactance saturated (X''d) Subtranscient time constant (T"d) (ms) Quadra axis subtranscient reactance saturated (X"q) Subtranscient time constant (T"q) (ms) Wave form : CEI=FHT <2 Zero sequence reactance unsaturated (Xo) 2,48 Number of bearing 1 Negative sequence reactance saturated (X2) 13,70 Coupling Voltage regulation at established rating (+/- %) Recovery time (Delta U = 20% transcient) (ms) Indication of protection Direct Armature time constant (Ta) (ms) 17,000 No load excitation current (io) (A) 0,71 Full load excitation current (ic) (A) 2,80 44,0 Technology Without collar or brush Full load excitation voltage (uc) (V) Engine start (Delta U = 20% perm. or 50% trans.) (kva) Transcient dip (4/4 load) - PF : 0,8 AR H 2,0 2,9 <40 1,00 IP 23 No load losses Without collar or (W) brush Heat rejection (W) Unbalanced load acceptance ratio 6,2 13,000 18,90 12,0 185,00 13,87 3425,00 14133,0 0 100 DIMENSIONS Containment DW Containment DW 48H M227 DW 4056 2340 3600 950 72 M227 DW48 4056 2618 3960 2130 72

CONTROL PANEL APM303, comprehensive and simple TELYS, ergonomic and user-friendly The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features: Measurements: phase-to-neutral and phase-to-phase voltages, fuel level (In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels) Supervision: Modbus RTU communication on RS485 Reports: (In option : 2 configurable reports) Safety features: Overspeed, oil pressure,coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power P<66kVA) Traceability: Stack of 12 stored events For further information, please refer to the data sheet for the APM303. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. The TELYS offers the following functions: Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. For more information on the product and its options, please refer to the sales documentation.

APM802 dedicated to power plant management Basic terminal block The new APM802 command/control system is specifically designed for operating and monitoring power plants for markets including hospitals, data centres, banks, the oil and gas sector, industries, IPP, rental and mining. This unit is available as standard on all generating sets from Kva designed for coupling. It is optional on the rest of our range. The Human Machine Interface, designed in collaboration with a company specialising in interface design, facilitates operations with a large 100% touch screen. The preconfigured system for power plant applications features a brand new customisation function which complies with the international standard IEC 61131-3. New communication functions (PLC and regulation), improve the high level of equipment availability in the installation. The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button, customer connection terminal block, CE. Advantages: Dedicated to power plant management. Specially researched ergonomics. High level of equipment availability. Modularity and long service life guaranteed. Making it easy to extend the installation For more information, please refer to the sales documentation.