MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Similar documents
UMBW-UL489 and UL1077 Listed

AF40... AF96 3-pole contactors Technical data

Thermal Overload Relays

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

ASL09..S 3-pole Contactors - Spring Terminals

Electronic overload relays EF205 and EF370

CI-TI Contactors and motor starters Types CI 61 - CI 98

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

SD Series Non-Fused Load Switches

Product Specification Sheet #3LD2.1

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Electronic overload relay EF65, EF96 and EF146

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

Contents. Volume 5 Motor Control and Protection CA E December

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

UL 508 Non-Fusible Disconnect Switches

Thermal Overload Relays - WEG RW Series, 2 Pole

Short form catalogue. Motor protection & control

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Protection Equipment

UL 508 Non-Fusible Disconnect Switches

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Switch Disconnectors

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF65 and TF96

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Phone: Fax: Web: -

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

KT4 Manual Motor Starter

Protection Equipment. 5/2 Introduction

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Thermal overload relay TF140DU and TF140DU-V1000

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Micro Contactor MA Series

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Overloadrelay,10-16A,1N/O+1N/C. Articleno

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Control switch/load disconnect switch Series 8008

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

BETA Switching Switches and Light Indicators

D509E. Manual Motor - Starters

Motors Automation Energy Transmission & Distribution Coatings UBW. Molded-Case Circuit Breaker UL 489 Listed

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400


Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SWITCH FUSES 3KL71 from 32A to 800A Description

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Controls. CONTACTORS CWB Line (up to 40A)

Ideal for use as a manual starter

Contactor Types CI 61-98

Vistop TM isolating switches 63 to 160A

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Technical Information

Manual Motor Starters. Meta-MEC

Technical Information

Bulletin 193-T1 Bimetallic Overload Relays

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Application Mini Contactors for Motors and Resistive Loads

TAE pole Contactors

KT4 Manual Motor Starters

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Control and Load Switch Specifications Bulletin Number 194E, 194L

Cylindrical fuse-link

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Star Series Motor protection & control

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

ZS4-SF1 Screw Clamp Terminal Block

Capacitor Switching Contactors Type K3...-A, K3...-K

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

K50H004UP cam changeover switch - 4-pole A - screw mounting

Transcription:

Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the panel. The has a range of 25 to 160Amps, panel or door mount options, and offers a variety of accessories. Standard Features Suitable as Motor Base or Door mounting options DIN or base mounted Through the door or direct mount handles Touch Safe IP20 Catalog Number Sequence Overview Mounting 25 B- 3 -H Amperage Ratings/ Accessories Door Mount- 25A, 40A, 63A, 80A, 100A, Panel Mount- 25A, 40A, 63A, 80A, 125A, 160A AP- Neutral Pole AC- Auxiliary Contact TS- Cover Current (A) Number of Poles Poles- 3 Mounting P- Panel Door Mount B- Base Mount Chart intended as reference only and not to create part numbers. Accessories H- Red/Yellow Handle, + Shaft (Base Mount) B- Black/Grey Handle, + Shaft (Base Mount) NA- Neutral Pole 1NO- Auxiliary Contact 1NC - Auxiliary Contact Handle Shaft (mm) Neutral Auxiliary contact Red/yellow Black/gray 85 185 300 pole 1NO 1NC 1NO/1NC 32 40 Panel door 63 80 100 32 t 40 t 63 t Base 80 t 125 160 Notes: t - Only available as part of the standard configuration. - Available as part of the standard configuration or it can be supplied separately. - Only available to be supplied separately. cover Relays Enclosed Overloads Contactors Motor Pushbuttons A B WEG Automation - Products and Solutions 73

Motor Contactors Overloads Relays Pushbuttons Enclosed for Panel Door Mounting Standard Configuration ( Switch + Handle Red/Yellow) Catalog Number Ith (A) Ie (A) AC21 (690 V) AC22 (690 V) AC23 (690 V) Poles List Price Multiplier 25 P-3 H 32 32 25 16 $80 40 P-3 H 40 40 32 20 $85 63 P-3 H 63 63 63 26 3 $137 80 P-3 H 80 80 80 32 $148 100 P-3 H 100 100 86 38 $185 and Accessories Switch Catalog Number Ith (A) Ie (A) Poles List Price Multiplier AC21 (690 V) AC22 (690 V) AC23 (690 V) 25 P-3 32 32 25 16 $53 40 P-3 40 40 32 20 $58 63 P-3 63 63 63 26 3 $110 80 P-3 80 80 80 32 $122 100 P-3 100 100 86 38 $158 Rotary Handle Catalog Number Switch Color List Price Multiplier H 40 P 25/40 Red/Yellow $27 H 100 P 63/80/100 Red/Yellow $30 H 40-P-B 25/40 Black/Gray $27 H 100-P-B 63/80/100 Black/Gray $30 Neutral Pole Catalog Number Switch Contact List Price Multiplier AP 25-P-1 NA 25 1 NO early make $42 AP 40-P-1 NA 40 1 NO early make $42 AP 63-P-1 NA 63 1 NO early make $49 AP 80-P-1 NA 80 1 NO early make $49 Auxiliary Contact Catalog Number Switch Contact List Price Multiplier AC-40 P 1NC 25/40 1NC $35 AC-40 P 1NO 25/40 1NO $35 AC-80 P 1NC 63/80 1NC $37 AC-80 P 1NO 63/80 1NO $37 Cover Catalog Number Switch Poles List Price Multiplier TS-40 P 25/40 $14 3 TS-80 B/P 63/80 $28 TS-100 P 1) 100 2 $70 Note: 1) Necessary 2 pieces of TS-100P to cover 3 poles. cover to line or load side (1 piece supplied). A B 74 1-800-ASK4WEG www.weg.net/us

Switch for Base Mounting (Screw or Din Rail) Standard Configuration ( Switch + Handle Red/Yellow + Shaft) Catalog Number Ith (A) Ie (A) Shaft length AC21 (690 V) AC22 (690 V) AC23 (690 V) (mm) Poles List Price Multiplier 25 B-3 H 32 32 25 16 85 $96 40 B-3 H 40 40 32 20 85 $102 63 B-3 H 63 63 63 26 85 $156 3 80 B-3 H 80 80 80 32 85 $167 125 B-3 H 125 125 125 80 300 $352 160 B-3 H 160 160 160 100 300 $490 and Accessories Catalog Number Ith (A) Ie (A) AC21 (690 V) AC22 (690 V) AC23 (690 V) 25 B-3 32 32 25 16 Poles List Price Multiplier 40 B-3 40 40 32 20 $59 63 B-3 63 63 63 26 $112 3 80 B-3 80 80 80 32 $124 125 B-3 125 125 125 80 $286 160 B-3 160 160 160 100 $435 Rotary Handle + Shaft Catalog Number Switch Color Shaft (mm) List Price Mulitplier H 40 B 25/40 Red/Yellow 85 $42 H 80 B 63/80 Red/Yellow 85 $45 H 160 B 125/160 Red/Yellow 300 $65 H 40-B-B 25/40 Black/Gray 85 $42 H 80-B-B 63/80 Black/Gray 85 $45 Shaft Catalog Number Switch Length (mm) List Price Multiplier HS 185-40 25/40 185 $12 HS 300-40 25/40 300 $17 HS 185-160 63/80/ 125/160 185 $20 HS 300-160 63/80/ 125/160 300 $26 Neutral Pole Catalog Number Switch Contact List Price Multiplier AP 25-B-1 NA 25 1 NO early make $42 AP 40-B-1 NA 40 1 NO early make $42 AP 63-B-1 NA 63 1 NO early make $49 AP 80-B-1 NA 80 1 NO early make $49 Auxiliary Contact Catalog Number Switch Contact List Price Multiplier AC-40 B 1NC 25/40 1NC $35 AC-40 B 1NO 25/40 1NO $35 AC-80 B 1NC 63/80 1NC $37 AC-80 B 1NO 63/80 1NO $37 AC-160 B 1NONC 125/160 1NO/NC $70 $53 Relays Enclosed Overloads Contactors Motor Pushbuttons Cover Catalog Number Switch Poles List Price Multiplier TS-40 B 25/40 $16 TS-80 B/P 63/80 3 $32 TS-160 B 125/160 $78 Note: cover to line or load side (1 piece supplied). A B WEG Automation - Products and Solutions 75

Technical Data Motor Contactors Overloads Relays Pushbuttons Enclosed A B IEC 60947-3 characteristics Units 25 40 63 80 100 125 160 Auxiliary contact Rated operating voltage U e V 690 Rated insulation voltage U i V 690 690 690 690 690 800 800 690 Rated impulse withstand voltage U imp (sectionable) kv 8 8 8 8 8 8 8 4 Rated thermal current Ith A 32 40 63 80 100 125 160 16 Rated thermal current in enclosed I the A 32 40 63 80 86 125 160 10 Frequency Hz 50/60 Rated operating current I e : alternate current AC-21A switching resistive loads 690 V A 32 40 63 80 100 125 160 AC-15 240 V-5 A AC-22A switching mixed resistive and inductive 500 V A - - - - 100 125 160 DC-13 250 V-0.44 A loads 690 V A 25 32 63 80 86 125 160-230 V A/kW 25/7.5 32/10 63/20 80/25 70/22 125/30 160/45 - AC-23A periodic switching of 3 phase 400 V A/kW 25/15 32/18.5 50/28 75/42 67/37 125/55 160/75 - motors 3 poles 500 V A/kW 22/15 27/18.5 50/35 75/52 67/45 100/63 125/80-690 V A/kW 16/15 20/18.5 26/25 32/31 38/37 80/75 100/90-230 V A/kW 22/5.5 27/7.5 45/14 60/19 60/18.5 - - - AC3 starting of cage motors 3 phase 400 V A/kW 22/11 27/15 40/22 55/30 55/30 - - - (interruption while running) 3 poles 500 V A/kW 22/11 22/15 35/24 45/31 55/37 - - - 690 V A/kW 16/11 16/15 22/21 25/24 32/30 - - - 230 V A 200 256 360 600 560 - - - Rated interruption 400 V A 200 256 320 536 536 1,000 1,280 - current AC-23A (cosfi 0.45) 500 V A 176 216 280 536 536 - - - 690 V A 128 160 176 256 304 800 800 - Short circuit characteristics Rated short-time short circuit withstand current Icw (1s) A 800 800 1,200 1,500 1,500 3,000 3,000 - Rated short circuit making capacity Icm A 1,500 1,500 2,200 2,800 2,840 4,500 4,500 - Conditional rated short circuit withstand current ka 10 10 10/5 10/5 10 15 15 1 Fuse rating gg 500 V A - - - - 100 125 125 10 690 V A 40 40 63/80 63/80 - - - - UL 508 characteristics use 600 V ac A 32 40 60 80 100 125 160 HD A600 ac Q600 dc Single phase 120 V ac HP (FLA) 1.5 (20) 2 (24) 2 3 3 (34) - - - 2 poles 240 V ac HP (FLA) 3 (17) 5 (28) 5 7.5 10 (50) - - - Standard motors load 240 V ac HP (FLA) 7.5 (22) 10 (28) 10 15 10 (28) 40 (104) 40 (104) - 3 phase 3 poles 480 V ac HP (FLA) 10 (14) 15 (21) 25 30 25 (34) 100 (124) 100 (124) - 600 V ac HP (FLA) 15 (17) 20 (22) 30 40 30 (32) 125 (125) 125 (125) - characteristics degree Handle EN 60529/UL 50 IP65 / Type 1-4-4X-NEMA 4X - s EN 60529 IP20 Material group EN 60947-1 - II IIIa IIIa II Pollution grade EN 60947-1 - 3 Flammability UL 94 - V0 Ambient temperature Operation C -25 +55 Storage C -30 +70 Climate withstand IEC 68 part 2-3 - Hot damp IEC 68 part 2-30 - Unsetted hot damp Switching force (3 poles) - - 0.8 Nm (7.1 lb.in.) 1 Nm (8.85 lb.in.) 1.5 Nm 2.6 (23 lb.in.) - Connections EN 60947-1 - - - - - - block caliber - - A6 A8 - - A2 screw - - M4 M5 M8 M8 M3.5 Tightening torque EN 60947-1 - 1.2 Nm 3 Nm 6 Nm 6 Nm 0.8 Nm - UL 508 10.6 lb.in. (1.2 Nm) 32 lb.in. (3.6 Nm) 53 lb.in. (6Nm) 7.1 lb.in. Main terminal capacity - mm² 1.5-10 6-25 10-70 10-70 1-2.5 Flexible conductors - AWG 12-6 10-2 3/0-6 3/0-6 18-12 - mm² 1.5-16 10-35 10-70 10-70 1-2.5 Solid conductors - AWG 12-6 10-2 3/0-6 3/0-6 18-12 Opening angles 90-76 1-800-ASK4WEG www.weg.net/us

for Panel Door Mounting 25...40P-3 (1.77) 45 45 B Pushbuttons A (0.94) 23,8 23.8 (1.87) 47,6 47.6 (2.06) 52,2 52.2 IN DIN - 35-35 mm MM EN50022) (EN Ø (2.64) 67 Ø67 (0.89) 22,522.5 (0.04) - (0.31) 1-8 1-8 (1.4) (1.09) (1.65) 27.6 27.6 42 42 (3.22) 81.9 81.9 40.5 (1.59) 40.5 (2.68) 68,1 68.1 (2.91) 73,8 73.8 d=8 Ø=8 3.2 (0.13 ) 3.2 24 Relays Enclosed Overloads Contactors Motor (0.94) 24 (0.89) Ø22.5 Ø 22.5 WEG Automation - Products and Solutions 77

63...80P-3 (1.43) 36,3 36.3 (2.85) 72,5 72.5 Motor (1.28) 32,5 32.5 (3.22) 81,9 81.9 (2.56) 65 65 Contactors Overloads Relays Pushbuttons Enclosed (1.4) (2.66) 67.5 51.25 (2.02) 51.25 PARAFUSO Screw 3,2X13 3.2x13 d=8 Ø=8 (0.14) Ø3.5 Ø 3.5 (1.42) / (1.89) Ø36 / Ø48 Ø 36 /Ø 48 Ø 10.5 (0.41) Ø10.5 A B PARAFUSO Screw 3X9,5 3x9.5 78 1-800-ASK4WEG www.weg.net/us

100P-3 (0.49) 12.5 12,5 (3.25) 82.5 82,5 A Pushbuttons (1.44) 36.5 3.54) 90 (3.74) 95 (4.17) 106 36,5 106 95 90 (2.52) 64 (2.64) Ø Ø67 67 (0.04) - (0.16) 1-4 1-4 (1.4) (2.95) 75 (3.38) 85.8 85,8 d=8 Ø=8 (1.42) 36 (0.13) Ø Ø3.3 (1.42) 36 (0.41) Ø Ø10.5 Relays Enclosed Overloads Contactors Motor PARAFUSO Screw 3.2X13 3.2x13 PARAFUSO Screw 3x9.5 3X9.5 B WEG Automation - Products and Solutions 79

Auxiliary Contact AC-40...80P1NC / AC-40...80P1NO (1.5) 38 Motor Cover TS-40P (1.77) 45 (0.05) 1.2 1,2 Contactors Overloads Relays Pushbuttons Enclosed TS-80B-P (2.07) 52,5 52.5 TS-100P (1.56) 39,5 39.5 (0.66) 16,7 16.7 (1.1) 28 (0.67) 17 (1.11) 28,3 28.3 (0.66) 16,8 16.8 (0.59) 15 15 (0.61) 15,5 15.5 (0.65) 16,5 16.5 (0.55) 14 14 14 (0.69) 17,5 17.5 (1.11) (0.75) 28.3 28,3 19 (0.55) 14 (0.69) 17,5 17.5 (1.63) 41,5 41.5 (1.73) 44 44 (1.67) 42,5 42.5 A B 80 1-800-ASK4WEG www.weg.net/us

for Base Mounting 25...40B-3 (0.17) Ø4.2 4,2 (1.77) 45 B A Pushbuttons (1.15) 29,3 29.3 (2.36) 60 (2.72) 69 (0.43) 11 (0.87) 22 (2.64) Ø Ø67 (2.93) 74,3 74.3 (0.2) 5 (0.04)-(0.31) (0.53) (2.37) 13.5 1-8 1-8 13.5 60.3 (1.4) (3.74)-(5.98) 95-152 152 max. max. (0.29) 7.3 (1.6) 40.6 d=8 Ø=8 (0.94) 24 (0.13) 3.2 (0.89) Ø Ø22.5 22.5 Relays Enclosed Overloads Contactors Motor WEG Automation - Products and Solutions 81

63...80B-3 (0.18) Ø4.5 4,5 (2.07) 52.5 52,5 (1.63) 41.3 41,3 (3.25) 82.5 82,5 (3.6) 91.5 91,5 DIN - - 35 35mm (EN (EN50022) Motor (0.86) 21,8 21.8 (3.59) 91,1 91.1 Contactors Overloads Relays Pushbuttons Enclosed (2.64) Ø Ø67 67 (0.04)-(0.31) 1-8 (1.4) (0.93) 23.6 (4.45)-(6.72) 113-113-170.65 170.65max. max. (2.67) 67.8 (0.29) 7.3 (2.02) 51.25 (0.2) 5 d=8 Ø=8 (0.94) 24 24 (0.89) Ø22.5 Ø 22.5 (0.13) 3.2 A B 82 1-800-ASK4WEG www.weg.net/us

125...160B-3 (0.18) Ø4.5 4,5 (2.57) 65,2 65.2 (4.02) 102,2 102.2 (4.46) 113,2 113.2 Pushbuttons DIN - 35mm (EN50022) Ø 67 (2.01) 51,1 51.1 (2.64) Ø67 (1.01) 25.6 25,6 (1.4) (0.04)-(0.16) 1-4 (5.71)-(16.36) 145-415.6 max. 3,150 (3.15) 80 145-415.6 max. (1.91) 48.5 48.5 (3.15) 80 (0.11) 2.8 (0.22) 5.5 d=8 Ø=8 Relays Enclosed Overloads Contactors Motor PARAFUSO Screw Screw 3,2X13 3.2x13 PARAFUSO Screw Screw 3X9.5 3x9.5 A B WEG Automation - Products and Solutions 83

Auxiliary Contact AC-40...80B1NC / AC-40...80B1NO (1.31) 33.3 33,3 Motor Cover TS-40B (0.53) 13,5 13.5 Contactors Overloads Relays Pushbuttons Enclosed (1.77) 45 TS-80B-P (2.07) 52.5 52,5 TS-160B (2.56) 65 65 45 (0.66) 16,7 16.7 (1.1) 28 (0.67) 17 (1.11) 28,3 28.3 (0.81) 20,5 20.5 (1.5) 38 (0.61) 15,5 15.5 (0.87) 22 (0.59) 15 15 (0.55) (0.55) 14 14 (0.69) (0.69) 17,5 17.5 17,5 17.5 (0.88) (0.88) 22,4 22.4 22.4 22,4 (1.39) 35,3 35.3 (1.67) 42,5 42.5 (2.07) 52,5 52.5 A B 84 1-800-ASK4WEG www.weg.net/us