Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design Available only on request

Similar documents
Proportional relief valves

Proportional relief valves with integral pressure transducer

Proportional reducing valves

Proportional reducing valves with integral pressure transducer

Proportional relief valves with integral pressure transducer

Proportional reducing valves

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Proportional directional valves digital, direct operated, open loop, with positive spool overlap

Proportional reducing valves

Proportional relief valves with integral pressure transducer

Proportional flow valves

Proportional pressure control cartridges with integral pressure transducer

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

CONTINENTAL HYDRAULICS VED03MX

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

ISO cartridge valves type LIM*, LIRA, LIC*

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Safety directional valves with spool position monitoring

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

Safety cartridge valves with poppet position monitoring

SOLENOID DIRECTIONAL VALVE

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

Pilot-Operated Proportional DC Valve Series D*1FH

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

Proportional directional valve, direct operated, with pq functionality

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

ISO cartridge valves type LIDEW* and LIDBH*

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Proportional pressure relief valve Type DBETRE

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Mounting Position Any Ambient Temperature Range -20 C to +60 C (-4 F to +140 F) Protection Class IP 20 acc. DIN 40050

4/3-Proportional Solenoid Valve direct acting with integrated Electronics Subplate to ISO4401 P4WEE 10

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

4/3 proportional directional valve, direct operated, with pq functionality and field bus interface (IAC-P)

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Directional servo-valve of 4-way design

Pressure relief valves type ARAM

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Q max (see specifications table)

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Hydraulic Valves «DSV»

Directional servo-valve in 4-way design

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

High-response valve with integrated digital axis controller (IAC-Multi-Ethernet)

GEMÜ 549 esydrive Motorized globe valve

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Butterfly valve control system Series 61

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Proportional pressure relief valve Types DBE(M) and DBE(M)E

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Proportional pressure relief valve Types DBE(M) and DBE(M)E

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Pressure and flow control system. Type SYDFE1-2X, SYDFEE-2X, SYDFEC-2X, SYDFEn-2X, SYDFED-2X. Features. Contents

Proportional pressure reducing valve, pilot operated, with inductive position transducer

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Pendulum valve control system Series 65

Safety valves direct, pilot operated and cartridge execution

Servo solenoid valves with on-board electronics (OBE)

Inductive conductivity meter

Proportional pressure reducing valve, pilot operated

4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING

Electronic Ballast EVG 2000-T

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve, pilot operated

Pressure and flow control system. Type SYDFE1-3X, SYDFEE-3X, SYDFEC-3X, SYDFEn-3X, SYDFED-3X. Features. Contents

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

Proportional pressure relief valve, pilot operated

Servo solenoid valves with positive overlap and on-board electronics

Proportional pressure reducing valve, in 3-way version

VER03M CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES VER03M - PROPORTIONAL PRESSURE RELIEF VALVES

Transcription:

Table TFS100-1/E Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design Available only on request T P RZMO-RES-N-NP-010 Proportional pressure relief and reducing valves with closed loop integral digital driver and remote pressure transducer. Executions: RE-N with basic integral digital electronic driver, analog reference signals and US port for software functional parameters setting RES-N with full integral digital electronic driver and fieldbus interface for functional parameters setting, reference signals and real-time diagnostics The integral digital electronic driver performs the valve s hydraulic regulation according to the reference signal and assures valve-to-valve interchangeability thanks to the factory presetting. Valve body Poppet Proportional solenoid Remote pressure transducer (to be ordered separately) Integral electronics US connector Fieldbus connector Main connector Screw for air bleeding The remote pressure transducer type E-ATR-8 must be ordered separately, see section 10 Typical application: installations where the proportional valve is far from the point of the hydraulic circuit in which the pressure has to be monitored. 1 MOEL COE OF PRESSURE RELIEF AN COMPENSATOR VALVES RE = basic integral driver RES = full integral driver RZMO - RE - N - NP - * / * / * * / * RZMO = size 06 (ISO 4401) AGMZO = size 10, 20, 32 (ISO 6264) LIMZO = size 16 80 (ISO 7368) LICZO = size 16 50 (ISO 7368) N = remote pressure transducer Fieldbus interfaces - US port always present (1): NP = Not present P = PROFIUS P C = CANopen EH = EtherCAT Valve size configuration, max regulated pressure, see tech. table of relevant RE/RES-P valves, as indicated in sect. 18 (1) RE available only in version NP; RES available only in version C, P, EH Series number Seals material, see sect. 7, 8: - = NR PE = FKM T = HNR ynamic response preset see section 9: - = omit for PI 1 fast (default) 2 = PI 2 standard 3 = PI 3 smooth Electronic options: C = current feedback for remote transducer 4 20 ma (omit for feedback signal 0 10 V) I = current reference input and monitor 4 20 ma (omit for standard voltage reference input and monitor ±10 V) Q = enable signal Z = double power supply, enable, fault and monitor signals (12 pin connector) 2 MOEL COE OF PRESSURE REUCING VALVES RZGO - RE - N - RZGO = size 06 (ISO 4401) AGRCZO = size 10, 20 (ISO 6264) LIRZO = size 16 40 (ISO 7368) RE = basic integral driver RES = full integral driver N = remote pressure transducer NP - * / * / * * Series number / * Seals material, see sect. 7, 8: - = NR PE = FKM T = HNR ynamic response preset see section 9: - = omit for PI 1 fast (default) 2 = PI 2 standard 3 = PI 3 smooth Fieldbus interfaces - US port always present (1): NP = Not present P = PROFIUS P C = CANopen EH = EtherCAT Valve size configuration, max regulated pressure, see tech. table of relevant RE/RES-P valves, as indicated in sect. 18 (1) RE available only in version NP; RES available only in version C, P, EH Electronic options: C = current feedback for remote transducer 4 20 ma (omit for feedback signal 0 10 V) I = current reference input and monitor 4 20 ma (omit for standard voltage reference input and monitor ±10 V) Q = enable signal Z = double power supply, enable, fault and monitor signals (12 pin connector) TFS100

3 HYRAULIC SYMOLS PRESSURE RELIEF VALVE RZMO-RE-N-*-010 RZMO-RES-N-*-010 RZMO-RE-N-*-030 RZMO-RES-N-*-030 AGMZO-RE-N-* AGMZO-RES-N-* T A P LIMZO-RE-N-* LIMZO-RES-N-* LICZO-RE-N-* LICZO-RES-N-* 4 HYRAULIC SYMOLS PRESSURE REUCING VALVE RZMO-RE-N-*-010 RZMO-RES-N-*-010 RZMO-RE-N-*-030 RZMO-RES-N-*-030 LIRZO-RE-N-* LIRZO-RES-N-* T A P AGRCZO-RE-N-*-010 AGRCZO-RES-N-*-010 5 GENERAL NOTES Proportional valves are CE marked according to the applicable irectives (e.g. Immunity/Emission EMC irective and Low Voltage irective). Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes supplied with relevant components. The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions or components, as prescribed by the European standards (Safety requirements of fluid technology systems and components-hydraulics, EN-982). 6 FIELUS - only for RES Fieldbus allows the direct communication of the proportional valve with machine control unit for digital reference signal, diagnostics and settings of functional parameters. Analog reference signal remain available on the main connector for quick commissioning and maintenance. For detailed information about fieldbus features and specification see tech table GS510.

7 MAIN CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 C Assembly position Any position Subplate surface finishing Roughness index, Ra 0,4 flatness ratio 0,01/100 (ISO 1101) MTTFd valves according to EN ISO 13849 See technical table P007 Ambient temperature range RE, RES: standard = -20 C +60 C, /T option = -40 C +60 C Storage temperature range RE, RES: standard = -20 C +70 C, /T option = -40 C +70 C Coil resistance R at 20 C 3 3,3 Ω Max. solenoid current 2,6 A Max. power RE, RES = 50 Watt Remote pressure transducer Power supply: +24VC @ max 100 ma Pressure input: voltage, maximum range ±10 VC Input impedance, Ri > 50 Ω Insulation class Protection degree to IN EN60529 Tropicalization uty factor EMC, climate and mechanical load Communication interface Communication physical layer current, maximum range ±20 ma Input impedance, Ri = 500 Ω H (180 ) ue to the occuring surface temperatures of the solenoid coils, the European standards ISO 13732-1 and EN982 must be taken into account IP66/67 with mating connectors Tropical coating on electronics PC Continuous rating (E=100%) See technical table G004 US Atos ASCII coding not insulated US 2.0 + US OTG CANopen EN50325-4 + S408 optical insulated CAN ISO11898 PROFIUS P EN50170-2/IEC61158 optical insulated RS485 EtherCAT IEC 61158 Fast Ethernet, insulated 100 ase TX (1) Average response time value; the pressure variation in consequence of a modification of the reference input signal to the valve is affected by the stiffness of the hydraulic circuit: greater is the stiffness of the circuit, faster is the dynamic response, see section 9. 8 SEALS AN HYRAULIC FLUI - for other fluids not included in below table, consult our technical office Seals, recommended fluid temperature NR seals (standard) = -20 C +60 C, with HFC hydraulic fluids = -20 C +50 C FKM seals (/PE option) = -20 C +80 C HNR seals (/T option) = -40 C +60 C, with HFC hydraulic fluids = -40 C +50 C Recommended viscosity 20 100 mm 2 /s - max allowed range 15 380 mm 2 /s Fluid contamination class Hydraulic fluid ISO 4406 class 20/18/15 NAS 1638 class 9, achievable with in line filter - 10 μm (β10 _>75 recommended) Suitable seals type Classification Ref. Standard Mineral oils NR, FKM, HNR HL, HLP, HLP, HVLP, HVLP IN 51524 Flame resistant without water Flame resistant with water FKM NR, HNR HFU, HFR HFC ISO 12922 9 YNAMIC RESPONSE - 4 pressure PIs The valve is provided with 4 PIs configurations to match different hydraulic conditions. The required PI configuration can be selected before the valve commissioning, through Atos E-SW software via US port. Only for RES the PI can be also selected in real time, through PLC via fieldbus. PI ynamic response example diagrams at side 100 80 Ref PI1 PI2 PI3 100 80 Ref PI1 PI2 PI3 1 Fast - default 2 Standard 3 Smooth Pressure [%] 60 40 high stiffness low flow small volume Pressure [%] 60 40 low stiffness high flow large volume 20 20 4 Open Loop Time Time Above indications have to be considered as a general guideline, being affected by hydraulic circuit stiffness, working flow and dead volume. The valve's dynamics can be further optimized on the specific application, customizing PIs parameters. TFS100

10 REMOTE PRESSURE TRANSUCER 10.1 Pressure transducer failure - only for /C option In case of pressure transducer failure, only for 4 20 ma pressure transducer feedback, the valve's reaction can be configured through Atos E-SW software to: - cut off the current to solenoid, therefore the regulated pressure will be reduced to minimum value (default setting) - automatically switch the pressure control from closed loop (PI1,2,3) to open loop (PI4), to let the valve to temporarily operate with reduced regulation accuracy 10.2 Remote pressure transducer factory preset The valve is factory preset to operate with pressure transducer type E-ATR-8 having a standard measuring range specifically sized to match the valve max regulated pressure. Please refer to below table to select the correct E-ATR-8 measuring range: Valve model Valve max regulated pressure E-ATR-8 standard pressure measuring range (table GS465) RZGO 32 = 32 bar 60 = 0 60 bar RZGO, RZMO 100 = 100 bar 160 = 0 160 bar 210 = 210 bar 250 = 0 250 bar AGMZO, AGRCZO 315 = 315 bar LIMZO, LIRZO, LICZO 400 = 0 400 bar 350 = 350 bar In case the selected pressure transducer has a measuring range different to the above standard, the valve pressure feedback scale must be set according to the new measuring range, using E-SW software. Please consider that a different pressure measuring range respect to the standard may cause following situations: - selected range higher than standard = the valve regulation accuracy will be reduced in consequence of the lower pressure feedback resolution - selected range lower than standard = the transducer could be damaged if the system pressure will exceed transducer max measuring range 11 ELECTRONIC OPTIONS Standard driver execution provides on the 7 pin main connector: Power supply - 24 VC must be appropriately stabilized or rectified and filtered; a 2,5 A fuse time lag is required in series to each driver power supply. Apply at least a 10000 μf/40 V capacitance to single phase rectifiers or a 4700 μf/40 V capacitance to three phase rectifiers Reference input signal - analog differential input with 0 +10 VC nominal range (pin,e), proportional to desired valve pressure regulation Monitor output signal - analog output signal proportional to the actual valve pressure regulation = 0 +10 VC nominal range Note: a minimum booting time of 500 ms has be considered from the driver energizing with the 24 VC power supply before the valve has been ready to operate. uring this time the current to the valve coils is switched to zero. 11.1 Option /I It provides 4 20 ma current reference and monitor signals, instead of the standard 0 +10 VC. Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 ma. It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by electrical noise; the valve functioning is disabled in case of reference signal cable breakage 11.2 Option /Q To enable the driver, supply 24 VC on pin C referred to pin : Enable input signal allows to enable/disable the current supply to the solenoid, without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1). 11.3 Option /Z It provides, on the 12 pin main connector, the following additional features: Enable Input Signal To enable the driver, supply 24 VC on pin 3 referred to pin 2: Enable input signal allows to enable/disable the current supply to the solenoid, without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1). Fault Output Signal Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4 20mA input, etc.). Fault presence corresponds to 0 VC, normal working corresponds to 24 VC (pin 11 referred to pin 2): Fault status is not affected by the Enable input signal Power supply for driver s logics and communication Separate power supply (pin 9,10) allow to cut solenoid power supply (pin 1,2) while maintaining active diagnostics, US and fieldbus communication. A safety fuse is required in series to each driver power supply: 500 ma fast fuse. 11.4 Options /C Option /C is available to connect pressure transducers with 4 20 ma current output signal, instead of the standard ±10 V. Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 ma. 11.5 Possible combined options: /CI, /IQ, /IZ, /CIQ, /CIZ

12 ELECTRONIC CONNECTIONS 12.1 Main connector signals - 7 pin - standard and /Q options PIN Standard /Q TECHNICAL SPECIFICATIONS NOTES A V+ Power supply 24 VC Input - power supply V0 Power supply 0 VC Gnd - power supply C AGN Analog ground Gnd - analog signal ENALE Enable (24 VC) or disable (0 VC) the driver, referred to V0 Input - on/off signal P_INPUT+ Pressure reference input signal: ±10 VC / ±20 ma maximum range Input - analog signal E INPUT- Negative reference input signal for P_INPUT+ Input - analog signal F P_MONITOR referred to: Output - analog signal Pressure monitor output signal: 0 10 VC / 0 20 ma maximum range AGN V0 G EARTH Internally connected to driver housing 12.2 Main connector signals - 12 pin - /Z option PIN /Z TECHNICAL SPECIFICATIONS NOTES 1 V+ Power supply 24 VC Input - power supply 2 V0 Power supply 0 VC Gnd - power supply 3 ENALE Enable (24 VC) or disable (0 VC) the driver, referred to V0 Input - on/off signal 4 P_INPUT+ Pressure reference input signal: ±10 VC / ±20 ma maximum range Input - analog signal 5 INPUT- Negative reference input signal for P_INPUT+ Input - analog signal 6 P_MONITOR Pressure monitor output signal: 0 10 VC / 0 20 ma maximum range, referred to VL0 Output - analog signal 7 NC o not connect 8 NC o not connect 9 VL+ Power supply 24 VC for driver s logic and communication Input - power supply 10 VL0 Power supply 0 VC for driver s logic and communication Gnd - power supply 11 FAULT Fault (0 VC) or normal working (24 VC), referred to V0 Output - on/off signal PE EARTH Internally connected to driver housing 12.3 Communication connectors - US connector - M12-5 pin always present 1 +5V_US Power supply 2 I Identification 3 GN_US Signal zero data line 4 - ata line - 5 + ata line + C fieldbus execution, connector - M12-5 pin (2) 1 CAN_SHL Shield 2 NC do not connect 3 CAN_GN Signal zero data line 4 CAN_H us line (high) 5 CAN_L us line (low) P fieldbus execution, connector - M12-5 pin (2) 1 +5V Termination supply signal 2 LINE-A us line (high) 3 GN ata line and termination signal zero 4 LINE- us line (low) 5 SHIEL Notes: (1) shield connection on connector s housing is recommended EH fieldbus execution, connector - M12-4 pin (2) 1 TX+ Transmitter 2 RX+ Receiver 3 TX- Transmitter 4 RX- Receiver Housing SHIEL (2) only for RES execution 12.4 Remote pressure transducer connector - M12-5 pin PIN SIGNAL TECHNICAL SPECIFICATION NOTES Voltage Current 1 VF +24V Power supply +24VC Output - power supply Connect Connect 2 TR Signal transducer Input - analog signal ±10 VC / ±20 ma maximum range Connect Connect 3 AGN Common gnd for transducer power and signals Common gnd Connect / 4 NC Not Connect / / 5 NC Not Connect / / Remote pressure transducer connection - example 2 1 3 5 4 ZH-5PM/1.5 or ZH-5PM/5 Voltage signal Current signal 1 VF+ 24V 1 V+ 1 V+ 2 TR 4 TR 3 TR 3 AGN 3 V0 4 NC 4 NC 2 NC 2 NC 5 NC 5 NC 5 NC ZE-08 1 4 2 5 3 to be connected to electronic driver to be connected to pressure transducer E-ATR Note: connectors front view TFS100

13 CONNECTIONS RE-N-NP RES-N-C / RES-N-P A COIL CONNECTION 7 PIN Standard and /Q option (male) RES-N-EH COIL CONNECTION 12 PIN /Z option (male) US (female) Note: river connectors front view REMOTE PRESSURE TRANSUCER (female) CANopen CONNECTOR (only for RES) PROFIUS P CONNECTOR (only for RES) EtherCAT (female - INPUT) EtherCAT (female - OUTPUT) 14 CONNECTORS ZM-7P 7 pin (Metallic) RE-N-NP RES-N-C / RES-N-P ZM-5PF CANopen ZM-5PM/P PROFIUS P ZM-12P 12 pin (Metallic) E-C-S-US/M12 US cable lenght 4m ZH-7P 7 pin (Plastic) ZM-4PM/E EtherCAT - INPUT A3 ZH-12P 12 pin (Plastic) RES-N-EH ZM-4PM/E EtherCAT - OUTPUT A4 ZH-5PM/1.5 or ZH-5PM/5 REMOTE PRESSURE TRANSUCER cable lenght 1,5m or 5m Note: use of metallic connectors is strongly recommended in order to fulfill EMC requirements 15 MOEL COES OF S AN COMMUNICATION CONNECTORS - to be ordered separately VALVE VERSION CONNECTOR COE PROTECTION EGREE ATA SHEET RE, RES RE/Z, RES/Z Remote Transducer C - CANopen P - PROFIUS P EH - EtherCAT ZM-7P (IN) ZH-7P (IN) A3 ZM-12P (IN) ZH-12P (IN) A4 ZH-5PM/1.5 ZH-5PM/5 ZM-5PF(IN) ZM-5PM/P (IN) ZM-4PM/E ZM-4PM/E IP67 TGS205, K500

16 PROGRAMMING TOOLS - see tech table GS500 Valve's functional parameters and configurations, can be easily set and optimized using Atos E-SW programming software connected via US port to the digital driver. For fieldbus versions, the software permits valve's parameterization through US port also if the driver is connected to the central machine unit via fieldbus. The software is available in different versions according to the driver s options: E-SW-ASIC support: NP (US) PS (Serial) IR (Infrared) E-SW-FIELUS support: C (CANopen) P (PROFIUS P) EH (EtherCAT) EW (POWERLINK) EI (EtherNet/IP) E-SW-*/PQ support: valves with SP, SF, SL alternated control (e.g. E-SW-ASIC/PQ) WARNING: drivers US port is not isolated! The use of isolator adapter is highly recommended for PC protection (see table GS500) US connection E-C-S-US/M12 E-A-S-US/OPT isolator 17 ELECTRONIC RIVERS Valve model rivers model RE E-RI-RE-N RES E-RI-RES-N Type Format ata sheet igital Integral to valve TGS205 Note: for main and communication connectors see sections 14, 15 18 INSTALLATION IMENSIONS Pressure relief RZMO-RE*-N-010 RZMO-RE*-N-030 AGMZO LIMZO Pressure compensator LICZO Pressure reducing RZGO-RE*-N-010 RZGO-RE*-N-033 AGRCZO LIRZO see technical table FS010 see technical table FS067 see technical table FS040 see technical table FS305 see technical table FS305 see technical table FS020 see technical table FS075 see technical table FS055 see technical table FS305 07/17