electrical data depending on insolation * 10 mw / cm² 100 mw / cm² open-circuit voltage 4,1 V 4,9 V voltage at nominal power Uoc

Similar documents
Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

Photovoltaic systems. Dr. Ervin Rácz, Ph.D. associate professor Óbuda Univesity Bécsi u. 94., Budapest H-1034 Hungary

November 2016 SOLIBRO GMBH COMPANY PRESENTATION RENEWABLE ENERGY DELEGATION FROM GERMANY. M.Sc.-Ing. Mostafa Kamal

Introduction to Solar PV. Basics

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Product Manual. Installation Instructions for CHSM-230M Series Solar Module


Energy.ca. www. Energy.ca. www. .GreenerEnergy.

Enabling Utility Scale PV: Challenges for Glass Makers

SOLON SOLbond Integra. The Innovative Solar Rooftop System.

User Manual. SōlStar T-12g (12-Watt) Folding Solar Charger for the Globalstar GSP-1600 Satellite Phone. Important Notice:

Components, Mounting Systems, In-roof PV Solutions FATH Solar About us Page 3

Final Report. Competitive Analysis: Levelized Cost of Electricity (LCOE) Rev C: January 24, 2008

GUIDELINE G1039 DESIGNING SOLAR POWER SYSTEMS FOR MARINE AIDS TO NAVIGATION (SOLAR SIZING TOOL)

Solutions for a Solar Powered World From R&D to Production

Lead-free modules with low silver content and innovative busless cell grid

Solar Electric Modules

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

CPV Industry Overview

X-SERIES SOLAR PANELS

Product Catalogue. Europe

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

PV System Components. EE 495/695 Spring 2011

White Paper. How Do I Know I Can Rely on It? The Business and Technical Cases for Solar-Recharged Video Surveillance Systems

Crane Inspection Log. Mailing Address: P.O. Box Tulsa, OK Phone: (918) Fax: (918)

HIT Photovoltaic Panels

Whether it s a harsh outdoor environment or an indoor desktop, PowerFilm has an optimal solution for your application.

Off-grid Power for Wireless Networks. Training materials for wireless trainers

PV Module Installation Manual

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

INSTALLATION AND SAFETY MANUAL for Cigs-2000A1 and Cigs-2000E1 Solar Photovoltaic Modules Release Date: Version: 1.1

Water temperature: Dirt loss: Total dynamic head:

NEW-TEK SCHMID R Company High-tech enterprise for the production of PV solar modules

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

Adélio Mendes. Light, from the Earth to the Stars Lisbon, July 2 nd, Chemical Engineering Department

PHOTOVOLTAIC SOLAR PANELS

INSTALLATION MANUAL ECOSOLARGY SOLAR MODULE

E-SERIES RESIDENTIAL SOLAR PANELS

HydroLynx Systems, Inc. Model 5033-XX Solar Panel. Instruction Manual

Q-CELLS CIGS THIN FILM MODULES: HIGHEST EFFICIENCY IN THE MARKET

UPGRADE OF AN INDUSTRIAL Al-BSF SOLAR CELL LINE INTO PERC USING SPATIAL ALD Al 2 O 3

THE NEW POWER TO FUEL OUR FUTURE

OUR PARTNERS. More: Please note: All product illustrations in this brochure may differ from the original.

- SPECIFICATIONS - - GREEN

Q-CELLS. Company Presentation Lisboa

Up to 45% more yield - possible only with the DEGERconecter.

Solar Power. Demonstration Site. Annual Performance Report 2017

1. Passive Solar Design

Ramp-up years: Q-Cells AG L3(2004) Focussed, specialised, independent producer of high performance crystalline solar cells

THE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY. PARTIAL STREET LIGHTING SERVICE RATE 117 Page 1 of 5

Ecole ECOCLIM2018 Le solaire photovoltaïque.

BIPV Training - B&C meeting

Back Contact Module Technology

Potential-induced degradation of n-type crystalline silicon photovoltaic modules

Concepts and Installation of Grid Connected PV Systems NIUE, July 2009

OVERSIZING WHITEPAPER

TSM-DC01A. The Solution NEW. linear performance warranty. Module can bear snow loads up to 5400Pa and wind loads up to 2400Pa

THINERGY MEC220. Solid-State, Flexible, Rechargeable Thin-Film Micro-Energy Cell

4 submersible pumps powered by renewable energy sources

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

SOLAR. Decorative solar lights LIGHTS

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

INSTALLATION MANUALFOR RISEN SOLAR MODULE

Introducing the world's most reliable solar panel. Company presentation / Solar panels

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

,!-"#ASCU 3 V TFT KUP / T/.,- * 5+47 =SBU>9L "# $& '% "#,!-"#ASCU,- M?OUP.

Solar Power for Emergency Communications

ESCI 61- PV Cells Modules and Arrays April 21- Week 3 Agenda

Hybrid Solar Panel Fuel Cell Power Plant

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

Details and specification for 30 W solar powered LED street lights.

Impact of Reflectors on Solar Energy Systems

Junction boxes. X series

Installation Manual. Opal Solar QSA Series

Designing Stand Alone Systems. Overview, components and function, Elements in Design

Heterojunction cells combined with smart wire bifacial modules

idealpv SSP1 220/270 Solar Panel

Ian Jones, TWI Ltd ITMA 2015, Milan

Montana State University: Solar Cells Lecture 9: PV Systems. Montana State University: Solar Cells Lecture 9: PV Systems

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

Description. Applications

Warranty on production defects: 12 years WP YEARS WARRANTY. CLASS 1 CLASS 1 Reaction to fire according to the UNI 9177 UNI standard IEC 61215

SOLAR PHOTOVOLTAIC V-SYS ULTRA - FLEXI - ON FLOOR - ON TOP. MADE IN FRANCE

Applications F 622 J F 104 M 050 C. Capacitance Code (pf) First two digits represent significant figures. Third digit specifies number of zeros.

PM220P00 / PM240P00 Installation Guide for Users

Introduction to Solar Cell Materials

PRESENTATION ON HYBRID SOLAR SYSTEM BASED ON SUN SINE SMART MICRO INVERTERS

Photovoltaic Solar Energy Unit EESFB

Dye sensitized solar cells - a successful research

Applied Materials is accelerating Solar

Philadelphia Solar Installation and Operation Manual

RENEWABLE ENERGY. Domestic Solar Solutions

Namibian Standards Institution (NSI) Standards Development Work Programme. August 2018

Photovoltaic Solar Energy Modular Trainers

Description. Applications

Canadian Solar Australia Australian Solar Council Professional Development Day INNOVATION QUALITY VALUE

Technical Series, Edition 16

VALTHERMO Contact Wires and Stranded Conductors

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Transcription:

-OEM-Module ASI 3 Oo 03 / 122 / 115 FA RWE SCHOTT Solar GmbH (a-si/a-si tandem cell technology) Phototronics glass thickness... 3,2 mm X2 overall dimension...parallel to cell (stripe)... 115 mm X1 overall dimension...normal to cell (stripe)... 122 mm X3 apertur dimension... minus edge area (minim. 2x1.5mm)... 110 mm X4 apertur dimension... normal to cell (stripe)... 108 mm area -pole... K- Code (with Code: "P" = isolated pole, "K -" = width of contact area) K- width of contact area -pole... 4,50 mm K+ width of contact area +pole... 4,50 mm edge... parallel to cell (stripe)... 2,50 mm L edge... normal to cell (stripe)... 2,50 mm position soldering terminal / cable... m code (with code: "2m" = contacted twice, "m" = contacted in the middle; "r" = contacted at the edge; f = contacted on whole contact area) number of cells... 3 pcs width of cells... 35,40 mm losses... - due to width of cell at 100mW/cm²... 22,28 % losses... - due to width of cell at 10mW/cm²... 2,23 % losses... - due to contact area / contact position at 100mW/cm²... 3,63 % active area... per cell... 38,94 cm² total active area... 116,82 cm² electrical data depending on insolation * 10 mw / cm² 100 mw / cm² open-circuit voltage Uoc 4,1 V 4,9 V voltage at nominal power Umpp 3,0 V 3,6 V short-circuit current Isc 24,9 ma 255,1 ma current at nominal power Impp 19,0 ma 154,6 ma nominal power Pmpp 57,1 mw 556,5 mw temperature coefficients temperature coefficient of V oc α - 0,33 %/K temperature coefficient of j sc β + 0,08 %/K temperature coefficient of P dmax γ - 0,2 %/K *) Stabilized electrical data, under spectrum AM 1.5; T c = 25 C = cell temperature, IEC 904 at 100mW/cm². The electrical values can vary by ± 10 %. The output power can be initially about 18 % higher than the figures in the data sheet. Consider the initial power gains when designing the system. subject to change without notice ASI 3 Oo 03-122-115 FA (87.232) 07.11.2008

SOLAR PHOTOVOLTAICS ASI OEM OUTDOOR E ASI OEM Outdoor Solar Modules for innovative autarchic electronic devices More Energy Double-stacked cells Stable performance Reliability and Quality Made in Germany Easy integration Excellent value for money No toxic materials Any shape and sizes in low or high volumes Back contact (metal) a-si PIN TCO Glass SCHOTT Solar is a leading OEM-supplier of solar modules for the electronics industry, offering a large variety of offthe-shelf modules and custom designed solar modules, adapted in size, shape and voltage to the needs of your product. With ASI OEM technologies we can provide adequate solar modules either for outdoor or for indoor applications. The technology of the ASI OEM Outdoor solar modules is mainly intended for light conditions as found outdoors. Power classes are available in nearly each size. The patented ASI -technology with its special stacked-cell design on the basis of silicon thin film guarantees years of unfaltering high performance. ASI OEM Solar Modules are intended for use by Original Equipment Manufacturers for the power supply of autarchic electronic and electrical devices and systems. Typical applications are Lighting, wireless application, traffic systems, security technology, telecommunication, mini solar home systems among others. Sunlight Application examples Cell construction More energy: Independent surveys have shown that - under realistic weather conditions such as low light or high temperature - ASI -technology produces approximately +20% more energy per rated Wp than other solar technologies. Double stacked cells: Covers more light spectra from the sun light to provide best power converting. Stable performance: ASI -technology provides most stable performance over many years, in comparison to most competitors. Reliability and Quality Made in Germany : The patented ASI -technology with its much defined circuit and laser structuring made by automated manufacturing processes ensures favourable prices, high performance and best reliability Made in Germany. Easy integration: The ready made ASI -OEM construction ensures easy integration and high resistance against UV, temperature and weather, even in the most extreme conditions. Excellent value for money: The optimal use of raw materials and automated manufacturing processes ensures favourable prices, high performance and environmental viability for all ASI OEM modules. No toxic materials: In comparison to CdTe or CIS solar technology, ASI - OEM components contain no toxic materials. Any shape and sizes: Manufacturing capabilities enable a wide range of module designing, voltage and current in low or high volumes.

S (λ), Intensity [rel. units] Spectral response Technical Data Characteristic data Base material Type of solar cells Spectral response Connections Polarity Glass Amorphous silicon (ASI ) on float glass a-si/a-si double stacked cells (PINPIN) 350 750 nm (Peak at 550 nm) Contact areas for soldering, spring or other connections Negative label visible on front Untrimmed edges, max. surface loading s = 14 N/mm 2 1.0 0.8 0.6 0.4 0.2 0 Sunlight spectrum, spectral response of ASI solar cells 400 Qualitative diagram a-si / a-si (stacked cell) Sunlight AM 1.5 600 800 1000 Wavelength λ [nm] Electrical cell data* Typical data at at 10 mw/cm 2 at 100 mw/cm 2 (low light) (STC) Voltage at nominal power U mpp 1000 mv 1200 mv Current density at nominal power I mpp 0.50 ma/cm 2 5.30 ma/cm 2 Open-circuit voltage U oc 1350 mv 1630 mv Short-circuit current density I sc 0.64 ma/cm 2 6.55 ma/cm 2 Nominal power density P nom 0.48 mw/cm 2 6.36 mw/cm 2 100 120 mw/cm 2 * 80 100 mw/cm 2 * *) The module voltage is given by multiplying the cell voltage by the number of cells. The absolute currents for a specific module type can be obtained by multiplying the respective cell area by the current density shown in the above given electrical data. 20 80 mw/cm 2 * 3 20 mw/cm 2 * *) Approximation: 1 mw/cm 2 =^ ca. 1250 Lux Stabilized data to standard test conditions (STC) with spectrum AM 1.5; at a cell temperature of 25 C. The nominal power may be initially approx. 18% higher The quoted power figures are subject to a production tolerance of 10%. The current values may be lower for certain design variants. Quality assurance: Automated check during production (100%) of the fill factor FF and opencircuit voltage at 10.000 Lux (approx. 8 mw/cm 2 ), FF = I mpp x U mpp I sc x U oc Check of module power P max at 100 W/m 2 (STC by using an IEC certified solar simulator and measurement of the open-circuit voltage at 2.800 Lux (aprox. 2.2 mw/cm 2 ). For module areas above 900 cm 2 these checks represent a 100% inspection, for smaller areas spot checks are performed. Other criteria upon mutual agreement. ma/ cm 2 6 5 4 3 2 1 I E=100 mw/cm 2 E=10 mw/cm 2 T c = 25 C Intensity dependence V 0 200 400 600 800 1000 1200 1400 1600 mv Benchmark: In comparison to other manufacturers which are offering initial data, ASI is always given stabilized. Also the energy yield performance of ASI is best under low light illumination conditions. Please ask for studies of independent institutes which are showing these benefits. Cell temperature coefficients Power TK (P nom ) -0.2 %/K Open-circuit voltage TK (U oc ) -0.33 %/K Short-circuit current TK (I sc ) +0.08 %/K Benchmark: Other solar technologies have temperature coefficient on power of -0.5 %/K wich effects power losses in high temperature. ma/ cm 2 6 5 4 3 2 1 I E=100 mw/cm 2 T c = 60 C 25 C 0 C Power density V 0 200 400 600 800 1000 1200 1400 1600 mv

Illumination Conditions The diagrams beside show the irradiation solar energy per day at two different locations and the seasonal differences due to the gegraphical latitude. 600 500 400 300 200 100 Irradiation in mwh/cm2 (monthly means) - Frankfurt / Germany Longitude [ E]: 8.68 / Latitude [ N]: 50.10 600 500 400 300 200 100 Irradiation in mwh/cm2 (monthly means) - Benin / Nigeria Longitude [ E]: 5.60 / Latitude [ N]: 6.32 0 January February March April May June July August September October November Dezember 0 January February March April May June July August September October November Dezember The following tables show the expected energy output of ASI OEM solar modules for two different locations under best and worst installation conditions. Frankfurt / Germany is representing Middle European irradiation conditions. Benin / Nigeria is representing irradiation conditions near the equator. The optimum conditions in the table are calculated for a fixed module installation with the best orientation to the sun. The shaded conditions are calculated for a year round shaded module. The tables show the daily energy output in mwh of an ASI Solar Module with an area of 25 cm 2. For Frankfurt in medium sun we will get in average 190 mwh/25cm 2 or on weakest month December approx. 50 mwh/25cm 2 : Daily energy output in mwh of an ASI solar panel with an area of 25 cm 2 Frankfurt Germany Benin Nigeria sun shading sun shading January 85 30 433 129 February 177 53 474 135 March 290 87 469 145 April 388 122 475 146 May 442 160 457 144 June 451 176 417 142 July 454 168 372 141 August 431 135 439 145 September 360 99 366 146 October 219 64 430 141 November 101 35 460 129 December 71 24 457 121 Average 289 96 437 139 The given energy outputs are approximate and may vary depending on weather conditions, tolerances and reflectivity of surroundings. Solar Module Calculation The autonomous photovoltaic system has to be designed according to the energy consumption (mwh), system voltage (V) and installation light conditions (mw/cm 2 ). An all the year operating system should be either designed according to the month with the lowest irradiation or the battery capacity is large enough to store sunny days energy for clowdy days. Calculation Example: Location: Frankfurt; sun and shadow average System Voltage: 6 V Electronic and Battery (8.4 Volt solar module is needed) Daily energy consumption (stand by): 1 ma x 8.4 V x 24 h = 202 mwh Daily energy consumption (operation):750 ma x 8.4 V x 0.1 h = 630 mwh Total energy consumption 832 mwh + 10% for electronic losses = 915 mwh In combination with a large capacity battery, which can overtake the sunny days energy for weak winter months the module size is: 915 mwh 190 mwh x 25 cm 2 = 120 cm 2 ; i.e. ASI 3 Oo 07/122/115 FA with active size 110 mm x 112 mm. In case the solar module should fully recharge every days consumption the module size is: 915 mwh 47 mwh x 25 cm 2 = 486 cm 2, i.e. ASI 3 Oo 07/144/325 FA with active size 132 mm x 322 mm

Limits Permissible module temperature -40 to +85 C Relative humidity Higher rel. humidites permissible depending on encapsulation. Soldering conditions 300 C - 350 C; 3 s (flux-cored solder) solder wire recommendations on request Module integration - Examples House integration With transparent cover Embedding seal transparent plastic cover e.g. silicon rubber housing Attention should be paid to increased light reflection and reduced transmission module receptacle with holes for cables Moulded plastic frame Laminated transparent front foil Clamping Framed Gluing aluminium profile carrier housing Corrosion protection: Corrosion protection is essential to the lifetime of the solar module. ASI OEM modules are extremely resistant to temperature effects. Mounting of ASI OEM modules must particularly provide protection against humidity. The proper choice of suitable sealing material is important. Please request for detailed Handling Specification. Shading: During installation care should be taken to ensure that the active photovoltaic area is not shaded. The cells (strips), which produce the least current due to shading, determine the total module current. Contacting Preparation before soldering: The panels have several connections. All types have metal coatings as points (M) or stripes (J, JF, JJF). The wires can be soldered directly on blank coating. However type MF and JF have punched removable foil points or stripes. These have to be taking off before soldering! Soldering specification: The solder point exists of Nickel. An adequate solder wire is needed to get best results. Solder station: flat soldering tip temperature controlled Soldering temperature: 300 350 C, typically 325 C, max 350 C Soldering time: typical 3 s Please request for detailed Handling Specification.

Dimensions and weights Maximum module size Cell thickness Weight 976 mm x 576 mm 3.2 mm ± 0.3 mm (standard) 2.3 mm ± 0.3 mm (option) (thinner glass on request) Length (m) x width (m) x thickness (mm) x 2.5 = Weight in kg Nomenclature (for instance) ASI 3 Oo 05 / 048 / 096 M Module version Overall dimension in mm parallel to cell arrangement (x 2 ) Overall dimension in mm normal to cell arrangement (x 1 ) Number of cells (N) Technology designation referred to spectrum and intensity of illumination OEM outdoor Glass thickness in mm Please ask for detailed List of available designs Technology: ASI Dimensions and tolerances (in mm) Front view Version MF Version P Cross-section X 2 ± 1 L L X 3 ± 0,1 X 1 ± 1 K- X 4 ± 0,1 K+ Active area 1,5 ±1 consisting of 1,5 ±1 Isolation line N cells Label for pole pole Non-active marginal areas may be covered Active area Rear view MF/P Rear protective foil Solder point, neg. pole Isolated negative pole Solder point, pos. pole 3.2 ± 0.3 alternative: 2.3 ± 0.3 (± 6 ) GLASS Glass edge (cut, DIN 1249-11K-KG) Max. blooming or glass protuberance 1.0. SC-Layers Rear protective coating thickness < 0.1 X 1 ; X 2 = max. 576 mm x 976 mm X 1 ; X 2 = 20 mm for glass thickness 3.2 mm X 3 mult. by X 4 = active module area N = Number of cells Module versions (multiple versions possible) Rear side protection: Version F with transparent protection foil Standard Version C without protection foil Contact area (for Version F): Version M with removable foil points for contact areas Version J with removable foil stripes for contact areas Version JJ with free stripes for contact areas Extra options: Version A with extra wide surrounding laser isolation line Version I with isolation circle for a drilling hole Version K circular solar module Version N with cables and sealed solder area Version P isolation minus pole (to in large active area) Other options on request

Customized solar modules Besides a broad range of standard modules, customized versions in ASI thinfilm technology can be specially manufactured for series production. Here, the solar module is based on a dedicated semiconductor design. The glass base area of 1000 x 600 mm 2 is subdivided to form submodules according to the customer s layout specification. Electrically inactive regions are provided between these submodules, and a computer controlled glasscutting machine makes the cut without damaging the active layers. Due to the high degree of automation and the low setting up costs, the ASI thinfilm technology represents the most economic method of manufacturing small customized modules. 2006 SCHOTT Solar GmbH, TM 55 006 (15) ASI-OEM Outdoor The solar modules are available in a range of: Size (max. 576 x 976 mm 2 ) Shapes (rectangular (standard), round) Electrical voltages (number of cells) Even transparent and inactive areas can be incorporated! MANAGEMENTSYSTEM DQS-zertifiziert nach DIN EN ISO 9001:2000 Reg.-No. 2184 DIN EN ISO 14001:1996 Reg.-No. 2184 SCHOTT Solar GmbH Phototronics Hermann-Oberth-Strasse 11 85640 Putzbrunn Germany Phone: + 49 (0) 89/ 46264-100 Fax: + 49 (0) 89/ 46264-111 E-Mail: asi.solar@schott.com www.schott.com/solar