APCO Rack System. A unique solution for the elimination of viruses, bacteria and VOC s. and saving energy FRESH-AIRE UV

Similar documents
Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

Installer s Manual. PCO/UV N-Duct Model

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Safety, Installation and Service Manual Models 1952, 1953 & 1972

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

MINISTICK TM UV Germicidal Ultraviolet Light

HARDWARE KIT INSTALLATION GLOVES

21", 33", 45", & 61" Installation & Operation Manual

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

INSTALLATION INSTRUCTIONS

2 Installation Notes

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

MCI. SynAIRgPURE. Owner s Manual

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

LUNA Air for life. Featuring: NASA Developed Technology. Owner s Manual. Photocatalytic Oxidation Induct Air Purification System.

Operating and Installation Instructions

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

WARNING Risk of property damage, injury, or death.

Installation Instructions

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Air Curtain. Installation, Operating and Maintenance Instructions

Installation & Operation Manual Chef Base

UV-AIRE AIR PURIFYING SYSTEM

CRD610 Automatic Fitting Inserter

STC2 Car Kit. Installation Guide

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

CAUTION: Read manual carefully for proper procedures and operation.

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Model G14SD Vapor Management System

Model 8144NC Fresh Air Ventilator

Item no Smart AC 200 USB. User s Manual

Installation / Operation Instructions Sunnex ORION Series Exam Lights

60 Watt Industrial LED Low Bay Light

Installation Instructions

User Guide IGD Series

User s Manual for Tennessee Chill Box System P/N CB8000

CRD600 Automatic Fitting Inserter

Electric Chainsaw Sharpener With Bar Mount

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Air-Operated Waste Oil Drainer

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

FADE Series Wall Axial Fans

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Viking Use/Installation Guide

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Customer Support

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

gamma uv Aquarium Ultraviolet Sterilizers

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Please activate my limited warranty for WAGAN Corp.

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

PVI 60KW, PVI 82KW, PVI 95KW

Female Plug. connecting to Fuel Quantity

1000-lb Hydraulic Truck Crane

HP190SL Series Slimline Radon Fans

16 Inch Hanging Pendant Barn Light

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

Owner s Installation Guide

110 Volt/12 Volt Portable Inflator

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

LIGHTNING PROTECTION UNIT (LPU)

AUTOMATIC SUBMERSIBLE UTILITY PUMP

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

UV-AIRE AIR PURIFYING SYSTEM

UNPACKING THE UNIT. Alcohol cleaning pad

SPC-PANEL Simplex, Single Phase Pump Control Panel

12 Volt Heavy-Duty Air Inflator

Field Lite. Ozone Generator. Instruction Manual. CAUTION: Read manual carefully for proper procedures and operation. V071818

PATRIOT INSTRUCTION MANUAL FMGRID-16, FMGRID-24, FMGRID-30 ELECTRIC GRIDDLES

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Remove packaging and place your SunTouch Plus on a level surface.

Installation Power Management Unit Battery Cables and Battery Harness

Power Inverter 400 MW Owner s Manual

FD Conveyor for FD 260 Tabber

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Kitchen Tech Series Air Curtain

Charging with AC (wall) Charger

Transcription:

FRESH-AIRE UV APCO Rack System A unique solution for the elimination of viruses, bacteria and VOC s 81cm - 117cm - 152cm UV-C lamps available and saving energy With the APCO Rack System it is also possible to reduce airborne odors and toxic fumes associated with volatile organic compounds (VOCs). Contaminants are captured by the activated carbon cells then photocatalyized into harmless water vapor and carbon dioxide. The carbon cells never photocatalysis. A refrigeration unit is a haven for bacteria, viruses, moulds and fungus. The problem arises when the unit s coiler become damp, while air condenses as the temperature falls. The damp environment on the coiler surface provides perfect growth conditions for the microorganisms. In contrast to sporadic cleaning, UVC system is an automatic and continuous cleaning method, which is largely maintenance-free. Coils with Mold Coils with UV Light Bennefits Kills mold, bacteria, and viruses in the HVAC system Eliminates VOC s Saves energy by keeping components cleaner Lowers maintenance costs reduced cleanings Less sickleave Increased food safety Guaran- UV-C light suppresses microbial growth on HVAC coils and surrounding areas +45 51 73 91 73 michael@airvention.com www.airvention.com

The Fresh-Aire UV APCO Rack System is designed for installation into commercial air handling units for both surface disinfection and the reduction of odor-causing and potentially toxic volatile organic compounds (VOCs) in the air. The system is equipped with adjustable extenders for maximum installation flexibility. The weather-resistant power supply can withstand the wet environment found inside HVAC enclosures or the exposed conditions of outdoor packaged air conditioning systems. The number and placement of UV lamp/carbon cell modules is determined by several factors including coil dimensions and odor reduction priorities. COMMERCIAL SERIES APCO RACK SYSTEM INSATALLATION & MAINTENANCE A Fresh-Aire UV commercial UV specialist can help configure the best system for your application. WARNING DISCONNECT IMPORTANT! Qualified technicians should install this product* Install in accordance with relevant building codes Read instructions carefully including safety warnings Parts Included A UV Lamp(s) 1 Year B UV Lamp(s) 2 Year C Lamp Cable D Power Supply(s) 10 * E Power Supply(s) 14 ** F H - Bracket G UV Lamp Mount with APCO Cells H UV Warning Sticker I Black Nylon Zip Ties J Sight Glass 1 K Self-Tapping Screws L ½ Pipe Strap M ½ EMT Tubing (not included) A *Installation of this product by anyone other than licensed HVAC or electrical contractors voids warranty. B C D E F G H WARNING I Optional Parts N 12 Stand-off TUVC-CMBRKT O Vertical Support Kit TUVC-VS J K L P Cable Strain Relief TUVC-SR½, ¾, 1 Q Mounting Magnet TUVC-LBRKT-MG R Door Interlock Switch TUVC-INTLCK S View Port TUVC-VP-D T Cable Extensions TUV-CBL5, 10 U Stainless Steel Tubing TUVC-SST¾ * 10 Power Supply 32 lamp single & dual M ** 14 Power Supply 32 lamp triple & quad 32 lamp High Output single & dual 46 lamp single & dual 60 lamp single & dual N O P Q R S T Vertical Support Kit requires ½ EMT Tubing (not included) U

System Configuration 1. Determine the dimensions of the coils or area to be irradiated. 1. Width 2. Use the following guidelines to estimate the number of lamps needed for proper coverage. Height Depth UV Lamp Configuration Guidelines Maximum germicidal effectiveness is within an 18 radius from UV lamp center axis The optimal distance between UV lamp(s) and the irradiated surface is 12 The distance between stacked UV lamps should not exceed 35 The distance between end to end UV lamps should not exceed 12 The distance of UV lamp ends to the edge of irradiated surface should not exceed 6 Fresh-Aire UV offers a free system configuration consultation service for commercial projects. Contact Fresh-Aire UV for details. Optimal Irradiation Distance 12 Lamp to Coil Coil 3. Before attaching the L-Brackets for mounting use the Optimal Irradiation Distance and Lamp Spacing diagrams to confirm that when installed the UV Lamps will be positioned properly. Lamp Spacing 35 Lamp to Lamp 12 Max. space between lamps 6 Max. space to end of coils 18 UV Effective Radius Overlap lamps where necessary 4. The APCO Rack System can be configured to fit virtually any commercial/industrial HVAC application. Modules can be daisy-chained end to end or offset to achieve the desired width. Rack Configurations Single UVC/APCO module Modules daisy-chained end to end Multiple offset modules 2

1 Assembly & installation Optional 12 Stand-Off First, determine the ideal mounting location within the air system then configure the APCO Rack System accordingly. The APCO Rack System can be mounted to the air handler wall or similar support several ways depending on the size, orientation, and distance of the mounting surfaces and surfaces to be irradiated. ½ EMT Tubing Optional 12 stand-offs can be used in place of L-Brackets. APCO Module L-Bracket UVC Lamp Optional 12 Stand-Off L-Bracket 1. L-Bracket mounting 1. In most situations, when the system is mounted to surfaces perpendicular to the surface to be irradiated, L-Brackets are attached to the wall or support with Self-Tapping Screws. 2. Optional 12 Stand-off adaptors are available if there is no suitable wall surface for mounting parallel to the coil. Use self-tapping screws to attach a ½ Pipe Strap onto the end of the stand-off then mount using Self-Tapping Screws. 2a. Alternate Mounting: Attach L-Bracket with ½ Pipe Straps to interior of Stand-off. This allows lamps to be positioned less than 12 from coil. 3. Optional Vertical Support 2. Optional 12 Stand-off ½ Pipe Coupling Conduit Conduit/ conduit Clamp Conduit 2a. Alternate Mounting of 12 Stand-off Conduit ½ Pipe Coupling 3. Optional Vertical Support adds strength to the conduit tubing support framework and prevents sagging on installations with two or more lamps per tubing length. Measure the distance from floor to ceiling then measure and cut tubing 1.75 less than that length. Use the ½ Pipe Couplings to extend the Vertical Support to floor and ceiling for a snug fit. Vertical Support 3

2 Install UV Lamps Snap UV Lamps into the Lamp Clamps. Be sure to clamp to the rubber lamp connector on one end and the ceramic lamp tip on the other end. DO NOT clamp onto the lamp glass. Use Black Nylon Zip-Ties to secure lamp cables to rack components and/or supports. 3 Mount Power Supply(s) Mount the power supply in a location (inside or outside of the HVAC system) that is convenient for access to the main power supply and for connection to the UV lamps. The power supply is weather resistant and is suitable for mounting inside or outside of the air handler. An Optional Power Supply Panel Mount (part # TUVC-P) is available for mounting two or more power supplies. UV Lamp 1. Use the supplied self-taping sheet metal screws to mount the power supply in place through the mounting holes on the sides of the base. It is recommended to use wire boxes, our Optional 3/4 or 1 Cable Strain Relief, or other sealing methods in order to pass the power cord and lamp cables into the interior of the air handler for connections. 2. IMPORTANT! Turn off main power before making electrical connections. Refer to the Electrical Diagram for proper connection of the power supply to the main power. Electrical Diagram UV LAMP UV LAMP CONNECTORS L1 BLACK L2 or N WHITE GND GREEN 120-277 VAC POWER SUPPLY IMPORTANT! Connect in accordance with all state and local electrical and building codes. Proper voltage is automatically selected by the unit between 120 277 VAC Single Phase 50/60 hz. IMPORTANT! An external power suppressor is suggested if power surges occur often. 3. Use of Optional Door Interlock Switches is highly recommended to prevent accidental exposure to UV Light. Interlock switches are mounted on the access panels and doors so the UV lights turn off when the entryway is opened. 4. Use the Optional UV Output Monitor, to monitor and alert maintenance personnel when UV lamps should be replaced. Optional Power Supply Panel Mount 4 Connect Lamps & Cables Arrange cables as needed for installation. If necessary use the Optional 3/4 or 1 Cable Strain Relief to pass cables through cabinets, air system walls, etc. Optional 5, 10, 20 Cable Extensions are available for longer runs. When UV lamps, power supplies, and cables are in place join the lamp and power supply cables by aligning the electrical pins and flanges on the rubber connectors and pushing them firmly together. Align Pins & Lamp Key Lamp Key UV Lamp 4 Push Firmly Together Power Supply Cable

5 Sight Glass Installation 1. The sight glass allows safe viewing of the UV light system when in operation. Find a suitable location such as a door to the HVAC system for the sight glass. 2. Drill a 1 hole and press the base of the sight glass through it. 6 Power-up System Caution: UV-C light that can cause Serious Eye Burns and Temporary Blindness, Ensure all access panels have been replaced and doors closed before powering-up the system. Turn on the main power then switch on the UV light power supply(s). Use the sight glass to confirm that the UV Lamp(s) is operating. 7 UV System Maintenance Periodically wipe the UV lamps with a clean cloth or alcohol swab to remove any accumulated dust or dirt. This should be performed at least every 6-9 months or during routine maintenance intervals. Fouling could occur if lamps are installed under chilled water lines. Wipe clean or install optional shield. 8 UV Lamp Replacement Fresh-Aire UV lamps are rated for either one or two years germicidal effectiveness. The lamps will continue to glow after they have passed their rated life span but their germkilling effectiveness diminishes with time so they must be replaced on schedule for the system to function properly. Contact your local dealer for replacement lamps. Important! Use only Fresh-Aire UV replacement lamps. Use of replacement lamps from other manufacturers voids the warranty. 9 Trouble Shooting Part# TUVCL-132 Part# TUVCL-132HO Part# TUVCL-232-TF Part# TUVCL-146 Part# TUVCL-246-TF Part# TUVCL-160 Part# TUVCL-260-TF 1 Year Effective Lamp Life High Output - 1 Year Effective Lamp Life 2 Year Effective Lamp Life 46 1 Year Effective Lamp Life 46 2 Year Effective Lamp Life 60 1 Year Effective Lamp Life 60 2 Year Effective Lamp Life Problem UV Lamp(s) Not Lighting UV Lamp(s) Flickering UV Lamps Have burned Out Prematurely Power Supply Will Not Light UV Lamps even after new lamps are installed Solution 1. Check that power is applied. 2. Check that the unit is turned ON. 3. Ensure the remote lamp cables are properly connected. 4. Check the fuse. Replace only with same size and type. 5. Reset power switch on power supply (off then on). 6. Install New UV Lamp(s). 7. Consult Factory. 1. UV Lamp(s) have reached end of effective service life. Install new lamp(s) of same type. 2. If unit is new, check remote cables to ensure they are properly connected. 3. Reset power switch on power supply (off then on). 4. If new lamps still flicker, consult factory. 1. Consult Factory. 1. Consult Factory. 2. External power suppressor may be needed if power surges occur. 5

Fresh-Aire UV Commercial Series Fresh-Aire UV lights save energy by reducing microbial growth inside HVAC systems, lower maintenance costs and reduce maintenance workers exposure to chemicals while improving indoor air quality. Our commercial systems are renowned for their quality materials, innovative features, ease of installation, and flexible mounting options. Most feature our advanced multi-voltage water-resistant power supply. All come with the Fresh-Aire UV Lifetime Warranty on all parts except lamps. Standard Commercial UV Light System Standard 32 lamps with L-brackets for easy installation. Choose 32, 46, 60 normal-output or 32 high-output lamps. Combine single, dual, triple, quad lamp configurations to suit any size HVAC installation. Tubular Rack System The Fresh-Aire UV Tubular Rack System offers easy, flexible installation of multi-lamp configurations. The Tubular Rack System is installed using supports made with standard ½ EMT tubing (not included). You can also choose to have custom steel tubing prepared for you by Fresh-Aire UV. The system includes all the hardware necessary for mounting. APCO Rack System Same as our Modular Rack System with the addition of activated carbon cells for photocatalytic VOC reduction. Airborne Duct System Features High-Output lamps for air-steam disinfection. Ideal for hospitals, clean-rooms, and other IAQ priority situations. Panel Mount System Installs in hard to reach areas by allowing access to the coil from the outside of the air system. Tight-Fit Kit Low-voltage UV disinfection for PTACs, fan coils, & wall-mount systems. Manufacturer s Warranty: This warranty supersedes and replaces any warranty statements orally made by the Sales Person, Distributor or Dealer or contained in the written instructions or other Brochures or informational documents in relation to this product. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. What Does This Warranty Cover? This lifetime limited manufacturer warranty covers any defects or malfunctions in material and workmanship under the normal use and service when operated and maintained in strict accordance with manufacturer s instructions for the Lifetime of the equipment. How Long Does The Coverage Last? 1) Fresh-Aire UV Power Supply: For as long as you own the real property where the product is installed. 2) TUVCL-1XX Series Ultraviolet Lamp is warranted for germicidal output for one-year from the date of installation. 3) TUVCL-2XX Series Ultraviolet Lamp is warranted for germicidal output for two (2) years from the date of installation. This warranty is not transferable. What Will Triatomic Environmental, Inc. Do? Triatomic Environmental, Inc. will replace any defective or malfunctioning part at no charge. You must pay any labor charges and shipping charges of defective product to our warranty department. What Does This Warranty Not Cover? THIS PRODUCT IS NOT INTENDED TO BE PURCHASED AND INSTALLED BY UNLICENSED HVAC OR ELECTRICAL CONTRACTORS. This warranty does not cover products or parts purchased from any source other than licensed HVAC or electrical contractors. This warranty does not cover parts installed by unlicensed HVAC or electrical contractors. This warranty does not cover parts damaged as a result of misuse, abuse, or any use other than its intended use, accident, acts of god, neglect, or from improper operation, maintenance, installation, modification or adjustments. Triatomic Environmental, Inc. shall have no responsibility for charges incurred by the customer for installation or removal of warranted items. This warranty does not cover parts or equipment used with the Fresh-Aire system that are not manufactured by Triatomic Environmental, Inc. **This warranty shall be void if UV lamps from manufacturer s other than Triatomic Environmental, Inc. are used with this equipment. Consequential and incidental damages are not recoverable under this warranty. Manufacturer assumes no liability for any harm, which may occur as a result of the use of the equipment herein and shall not be liable for consequential or any other damages whether or not caused by manufacturer s negligence or resulting from any express or implied warranty or breach thereof. Consequential damages for the purpose of this warranty shall include, but not be limited to, loss of use, income or profit, or loss of or damages to property or injury or death to persons or animals occasioned by or arising out of operation, use, the operation, installation, repair or replacement of the equipment or otherwise. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. There are no Warranties which extend beyond the description of the face hereof. How Do You Get Service? In order to be eligible for service under this warranty you MUST return the warranty registration card or register online at www.freshaireuv.com. If something is wrong with your product, call your installing contractor to receive a Return Merchandise Authorization (RMA) and instructions for returning the product to a licensed distributor in your area or the manufacturer. Once the product is returned, we will inspect your product and contact you within 10 business days of our receipt of the product to give the results of our inspection. If we determine that the product is covered under this warranty, we will ship to you at no additional cost a replacement part. Replacement parts may be refurbished. If we determine that the product is not covered under this warranty, or that this warranty is void, the product will be returned to you COD. There is no charge for inspection. How Does State Law Apply? This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 2015 SALES@FRESHAIREUV.COM TUVC-APCO-MAN 12.18.15