Transforming Energy.. For Advanced Technology

Similar documents
2 SLR Series Line Reactors... 50

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

LV Capacitor CLMD03 Power Module Instruction manual

ABB n.v Power Quality in LV installations

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

ELECTRICAL POWER and POWER ELECTRONICS

AIR CORE REACTORS. Phoenix Electric Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Power System Solutions (PSS)

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

smartvar Dynamic VAR Compensator

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Solid-State Relays. Solid-State Relays. Features. Description. Overview

HARMONIC FILTER REACTOR

Solid-State Relays. Solid-State Relays. Features. Description. Overview

AC Line / Load Reactors

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Experience and History

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

POWERTRONIX QUASAR 5-40 KVA

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

DYNACOMP. The top-class reactive power compensator

RLW Reactors. Product Selector. Smaller. Lighter. mtecorp.com. Proven performance in the field. Reliable and economical. Compact and light-weight

High Reliable Components for Power Factor Correction and Power Quality

Impulse Voltage Test System, Q Structure, kV

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Ventilated Distribution Transformers

ENERGY EFFICIENT MOTORS AND POWER SAVING Dr. K. Brahmanandam E.E.E Department, M.V.S.R.E.C, Hyderabad, India

AIR COOLED RECTIFIER SPECIFICATION S-50-A

FUSES. Safety through quality

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

HIGH POWER RECTIFIER SYSTEMS

About us. Switchgear Factory, Mumbai

PRODUCT CATALOGUE 2016

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

MODVAR Low voltage reactive power compensation modules Installation manual

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

DC CIRCUITS ELECTROMAGNETISM

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Ventilated Distribution Transformers

Power Factor Correction

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Dry Type Distribution Transformers

Power Factor Correction Capacitors Harmonic Filter Reactors

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Since then, products have been introduced and expanded to include:

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Functions provided by measuring relays in railway equipment

ELG4125: Flexible AC Transmission Systems (FACTS)

PRODUCT SPECIFICATIONS

AF series contactors (9 2650)

Electrical Power Electric power electrical electric power Electric power electric electric

MGE TM Galaxy TM 7000 GFC

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

Three Phase UPS Systems Range: 10 to 500kVA

LG HRC Power Fuses ISO 9001 ISO 14001

Chapter 3.1: Electrical System

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

MGE TM Galaxy TM 7000

High Reliable Components for Power Factor Correction and Power Quality

years old German company involved in above mentioned two organizations for all Organization :- REO-GPD is supported by workforce of 15 workers.

Welcome. Power Survey International

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

1321 Power Conditioning Products

RECOMMENDATIONS FOR USING FREQUENCY INVERTERS WITH POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS

Current accuracy class. Sensor principles

Renewable Energy Systems 14

MTE AC Line / Load Reactors Price book

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

HV Compensation & Filtering Products

Description Reactor, Open; 460 V 3 Phase; Power Rating 30 HP; Impedance 3 Percent; Inductance 0.7 Millihenry; Baldor Brand; Current Rating 45 Ampere

ABB Wind Power Solution

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

LV Capacitor CLMD Reliability for Power Factor Correction

AF series contactors (9 2650)

2014 ELECTRICAL TECHNOLOGY

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Onfiniti. 1 Phase UPS

Three Phase Capacitors KNK

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Sources, Effect, and melioration. Power Quality Problems. Asnil Elektro FT UNP

Power Voltage Transformers for Air Insulated Substations

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Transcription:

Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial Area,Peenya 1 st Stage Bangalore 560058 Phone : 080-28391910,28391909, M 9845286892,9845546243,9880034892 Email :admin@tsius.in ts.us.marketing@gmail.com For Advanced Technology

Chokes DC Chokes AC Chokes Line Filters And all type of Line Chokes Details of Specialized Products Transformers Isolation Transformer Ultra Isolation Transformers Control Transformers High Voltage Transformers Auto Transformers Filament Transformers Lighting Transformers Furnace Transformers Thyristor Drive Transformers Rectifier Transformers 3Phase to 1Phase Conversion Transformers Charger Transformers Inverter Transformers Dry type Distribution Transformer Step up & Step Down Transformer Synchronization Transformers Reactors Detuned Reactors Block Reactors Discharge Reactors Power Factor Improvement Reactors Cont..

About our company T.S. International is a unit of Unit Services Group of Companies, located at Bangalore, India. This Group has been making significant contribution in the field of electrical transformers and reactors from last 3 decades with highly qualified and trained personnel. Our challenge is to bring to our customer, transformers and reactors that are as modern as their own products. Since our customers are all leaders in their own industry, rising to meet the global requirements every day, using the full potential of our people is what TS is all about. Details of Our Products 3 Phase to Single/Two Phase Conversion transformer up-to 1000KVA. Single Phase Transformer Range: 5 VA to 1000 KVA up-to 11KV Class Three Phase Transformers Range: 50 VA to 1000 KVA up-to 11KV Class Single Phase Auto Transformers Range: 10 VA to1000 KVA up-to 11KV Class Three Phase Auto Transformers Range: 100 VA to 1000 KVA up-to 11KV Class Three Phase Auto Transformers Range: 100 VA to1000 KVA up-to 11KV Class Single Phase Chokes & reactors Range: Up-to 5000AMPS Three Phase Chokes & Inductors Range: Up-to 5000AMPS

CNC Machines Control Panels Furnace PLC s Rectifiers Filament Applications Lighting UPS Servo Stabilizers Conveyors Packing Machines Spm Machines Safety Equipments Thyristor Drives (Snubbing) Power Factor Improvements Capacitor Discharging Scott Connections Filters Choppers Telecom (Mobile Towers) Major Applications Control Panels Drives Motors Steel plants Capacitor s filters

DRY TYPE FURNACE TRANSFORMERS Dry type transformers are advantageous compared with oil filled transformers. They avoid the perceived fire risk of oil filled transformers and thus be accommodated inside a building or even on the roof of an office block Dry type transformers is of low maintenance and high reliability Isolation Transformers Isolation Transformers are separate primary and secondary winding are intended to convert the input voltage to a more useful level and attenuate the passage of noise or transients from primary to secondary by the way of copper shielding between primary and secondary. Ultra Isolation Transformers will suppress all type of electrical noise predominantly common mode noises and normal mode noises since it isolates primary and secondary are separates neutral to ground bound on the secondary side, can be used to create separately derived source to fight current loops. Commonly used to protect computers, CNC machines and telecommunication equipments from damage due to electrical noise, spikes etc.,

DISCHARGE REACTORS PRINCIPLES Discharge Reactors satisfy the requirement for permanently connected discharging devices and for a discharge time of a few seconds Because of its high AC resistance discharge reactors generates extremely low loss during operation of the capacitor. When Capacitors are turned off there is very fast discharge over the low DC resistance FEATURES Fast discharge for fast reconnection of capacitors Reduced losses Shockproof case for din rail mounting Instead of single phase loading the load will be distributed 66% in all the 3 phase lines so that it creates maximum usage of connected electric power. This transformer is having four limbs and its magnetic properties selected to exhibit sufficient leakage inductance to provide greatest possible attenuation of normal mode power line noise 3PHASE TO SINGLE PHASE

LINE REACTORS It is installed between Electricity Supply and Thyristor drive. It proctect the drives short circuit current from load developed Which is normally used in Sugar, Paper, Cement, Pharmaceutical and Steel Plants Reduce Surge Currents Reduce Motor Temperature Reduce Motor Audible Noise Improve True Power Factor Reduce Output Voltage dv/dt Virtually Eliminate Nuisance Tripping About Salient Features of Products Rugged Construction for maintenance free performance Low Watt loss with high silicon steel. Extra sheet enclosure as per customer requirements Earthing Point Provided Confirms to relevant IS & International Standards Testing carried out by calibrated quality test equipments Our Ultra Isolation Transformer protects Strong Lightning, Impulse Noises.

T.S International 3PH FILTER REACTOR NEED 3PH filter Reactor are built with permeability iron sheet cores & copper Windings it provide a variety of protective functions- To limit short circuit currents to defined levels. To block Harmonics. To protect capacitors in Reactive current balancing systems. To reduce dv dt values in Drive Systems. In commutation notch protection The resonance phenomena can be avoided by connecting capacitors in series with filter Reactors, Detuned system are scaled so that the Self-resonant frequency is below the lowest line harmonic. Line Voltage for series combination of Reactor & capacitors: 380V, 415V, 433V, 440V AC.50H 3ph supply. Current : Continuous RMS value: 150% of the rated current. Winding: Electrolytic grade copper winding. Operating ambient temperature -10 to +50 Deg C. Storage temperature -10 to +75 Deg C. Supply frequency: 47Hz to 53Hz.

T.S International 3PHASE DETUNED FILTER REACTOR FEATURES (C.P.R.I Approved) High resistance to harmonics Very low losses High linearity to avoid choke tilt Low noise Simple mounting Long APPLICATION useful life OF FILTER REACTORS Protection of switchgear and contactors used in capacitor panels. Stabilization of system voltage. No overload on capacitors. Protection of capacitors against harmonics and improvement of systems power factor. Filter reactors Better impedance behavior of mains supply

Detuned Reactor Technical Data Specification : IS-5553-1990/IEC 60289 (1988) Range : Output up to 100KVAR : Filter factor 7%,14% : Rated voltage -440V.550V.690V Type : Detuned, copper wound-iron core dry type Features Reactors manufactured as per IS 5553/IEC 60289 (1988) Linearity more than 160% For Triplen and Non-Triplen Harmonic suppression though PF Capacitors. Copper wound reactors with 150% continuous RMS rating with 100% current THD-F factor. Line Voltage for series combination of Reactor & capacitors: 380V, 415V, 433V, 440V, 690V AC.50Hz 3ph supply. Current : Continuous RMS value: 150% of the rated current. Winding: Electrolytic grade copper winding. Operating ambient temperature -10 to +50 Deg C. Supply frequency: 47Hz to 53Hz. Coil wound with multiple conductor to reduce skin effect. Gives harmonic free supply to your equipment's. Mechanical sturdy design to withstand vibrations keep low noise level and ensure performance guarantee. Noise level less than 60dB at rated load

Our Services The driving force behind our performance has been our customer service ensuring prompt attention to customers. On-time delivery of orders, every dispatch is measured against commitment dates. Meeting the needs of the customer is major priority