Conduit Bushings for Rigid Metal Conduit and IMC

Similar documents
Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Taxonomies, Classifications, and Categories MYER'S HUB, 3-PIECE COUPLINGS, THREADLESS COUPLINGS AND THREADLESS CONNECTORS

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Cable Connectors & Conduit Sealing Bushings

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

General Cable Support Information

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Ground Connectors All Copper Alloy Specification Grade

Cable Connectors & Conduit Sealing Bushings

Thin Wall Conduit Fittings (For EMT Conduit)

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Non-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

CP Myers Hubs. Class I, Div. 2 Class II, Div. 1 and 2 Class III. when installed in accordance with the NEC. Features. Material.

Rigid Metal Conduit, IMC or EMT K-Clamps

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

americanfittingscorp.com t: e:

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Commercial Products. New Products in the Commercial Products Product Line

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

U-18. Company furnishes and installs: 10. Service lateral and connectors. 11. Conduit package, Amperes.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

EC&N. Elbows, Couplings & Nipples

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:

320A Single Phase URD Meter Loop Installations

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Customer Requirements Meter Socket Configurations

CONDUIT BODIES CONDUIT BODIES. Phone:

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

GSC CONDUIT FITTING SOLUTIONS PRODUCT CATALOG

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

PRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

DEMANDING CONDITIONS, DEMAND THE BEST!

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

Spring-loaded cover seats against neoprene gasket.

ALUMINUM OUTLET BODIES

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Armoured Cable/Flex. Conduit

Areamaster LED Flood/High Bay Luminaires

Aluminium Conduit. Kopex Martel. Fittings. Liquid Tight Fittings Coupler Connector. PVC Coated Conduit. Fittings. Egatu

Condulet Cast Device Boxes and Covers Application and Selection

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits

Product Catalog. Rev. 612 r1

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

American made. American strong. The mark of a true craftsman. A strong history. Mission. . Republic Steel acquires facility from Elyria Iron and Steel

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Junction Boxes Hazardous and Non-Hazardous

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Lighting and Power Distribution Panelboards

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

AMERICAN FITTINGS Corporation

Corrosion Protection for Electrical Conduit and Fittings

UNDERGROUND SERVICES - SECONDARY

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

In This Section. and. Fittings & Non-Metallic Rigid Conduit Fittings and Accessories. Steel City Fittings

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

General Specifications for Lighthouse Power Pedestal

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

PV Vault Yielding safety quickly

Enclosures. Section E

SECTION PANELBOARDS

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

ELECTRICAL CONDUIT. EMT IMC Rigid Aluminum

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Note: Supply from an underground network often requires use of stud type connector. Consult your local utility.

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Transcription:

Applications Used with a locknut to terminate rigid metal conduit or IMC conduit to a box or enclosure. Features Provides a smooth pulling surface. Material/Finish BU: malleable iron/zinc electroplated BBU: impact resistant plastic or thermoplastic Certifications and Compliances UL Standard: 514B UL Listed: E14814 CSA Standard: C22.2 No. 18.3 CSA Certified: 065178 NEMA: FB-1 Threaded s Malleable Iron, Zinc Electroplated 1/2 26.2 (1.03) 9.7 (0.38) 1.36 (3.00) BU50 3/4 31.8 (1.25) 11.2 (0.44) 1.81 (4.00) BU75 1 39.6 (1.56) 12.7 (0.50) 3.18 (7.00) BU100 1-1/4 50.8 (2.00) 16.0 (0.63) 5.90 (13.00) BU125 1-1/2 54.9 (2.16) 16.0 (0.63) 6.35 (14.00) BU150 2 66.8 (2.63) 16.0 (0.63) 8.62 (19.00) BU200 2-1/2 81.0 (3.19) 19.1 (0.75) 19.50 (43.00) BU250 3 96.8 (3.81) 23.9 (0.94) 25.40 (56.00) BU300 3-1/2 112.8 (4.44) 23.9 (0.94) 34.47 (76.00) BU350 4 125.5 (4.94) 26.9 (1.06) 49.44 (109.00) BU400 5 152.4 (6.00) 30.2 (1.19) 65.32 (144.00) BU500 6 187.5 (7.38) 33.3 (1.31) 110.22 (243.00) BU600 Threaded s Insulated 150 C Temperature Rating Malleable Iron, Zinc Electroplated 1/2 30.2 (1.19) 12.7 (0.50) 1.81 (4.00) BU50I 3/4 36.6 (1.44) 14.2 (0.56) 2.72 (6.00) BU75I 1 44.5 (1.75) 16.0 (0.63) 4.08 (9.00) BU100I 1-1/4 54.1 (2.13) 19.1 (0.75) 4.54 (10.00) BU125I 1-1/2 58.7 (2.31) 22.4 (0.88) 8.62 (19.00) BU150I 2 71.4 (2.81) 23.9 (0.94) 10.89 (24.00) BU200I 2-1/2 85.9 (3.38) 25.4 (1.00) 21.32 (47.00) BU250I 3 103.1 (4.06) 28.7 (1.13) 27.22 (60.00) BU300I 3-1/2 114.3 (4.50) 30.2 (1.19) 31.30 (69.00) BU350I 4 131.8 (5.19) 33.3 (1.31) 45.36 (100.00) BU400I 5 153.9 (6.06) 33.3 (1.31) 90.72 (200.00) BU500I 6 184.2 (7.25) 33.3 (1.31) 110.22 (243.00) BU600I 2241

Threadless s Insulated 150 C Temperature Rating Malleable Iron, Zinc Electroplated 1/2 30.2 (1.19) 9.7 (0.38) 1.36 (3.00) BU50SI 3/4 36.6 (1.44) 11.2 (0.44) 1.81 (4.00) BU75SI 1 44.5 (1.75) 12.7 (0.50) 3.18 (7.00) BU100SI 1-1/4 54.1 (2.13) 16.0 (0.63) 5.90 (13.00) BU125SI 1-1/2 58.7 (2.31) 16.0 (0.63) 6.35 (14.00) BU150SI 2 71.4 (2.81) 16.0 (0.63) 8.62 (19.00) BU200SI 2-1/2 85.9 (3.38) 19.1 (0.75) 19.50 (43.00) BU250SI 3 103.1 (4.06) 23.9 (0.94) 25.40 (56.00) BU300SI 3-1/2 114.3 (4.50) 23.9 (0.94) 34.47 (76.00) BU350SI 4 131.8 (5.19) 26.9 (1.06) 49.44 (109.00) BU400SI Threaded Capped s Malleable Iron, Zinc Electroplated, Polyethylene Cap 1/2 26.2 (1.03) 9.7 (0.38) 1.36 (3.00) BUC50 3/4 31.8 (1.25) 11.2 (0.44) 2.27 (5.00) BUC75 1 39.6 (1.56) 12.7 (0.50) 3.63 (8.00) BUC100 Commercial Products 1-1/4 50.8 (2.00) 16.0 (0.63) 5.44 (12.00) BUC125 1-1/2 54.9 (2.16) 16.0 (0.63) 7.71 (17.00) BUC150 2 66.8 (2.63) 16.0 (0.63) 9.07 (20.00) BUC200 2-1/2 81.0 (3.19) 19.1 (0.75) 18.14 (40.00) BUC250 RIGID AND IMC FITTINGS 3 96.8 (3.81) 23.9 (0.94) 23.59 (52.00) BUC300 3-1/2 112.8 (4.44) 23.9 (0.94) 34.47 (76.00) BUC350 4 125.5 (4.94) 26.9 (1.06) 51.71 (114.00) BUC400 5 152.4 (6.00) 30.2 (1.19) 67.59 (149.00) BUC500 6 187.5 (7.38) 33.3 (1.31) 113.40 (250.00) BUC600 2242

Threaded Impact Resistant Plastic 105 C Temperature Rating 1/2 26.9 (1.06) 10.4 (0.41) 0.27 (0.60) BBU50 3/4 33.3 (1.31) 10.4 (0.41) 0.36 (0.80) BBU75 1 39.6 (1.56) 14.2 (0.56) 0.68 (1.50) BBU100 1-1/4 48.5 (1.91) 14.2 (0.56) 1.04 (2.30) BBU125 1-1/2 55.6 (2.19) 14.2 (0.56) 1.36 (3.00) BBU150 2 68.3 (2.69) 16.0 (0.63) 1.81 (4.00) BBU200 2-1/2 81.0 (3.19) 18.3 (0.72) 3.54 (7.80) BBU250 3 97.5 (3.84) 19.1 (0.75) 4.54 (10.00) BBU300 3-1/2 110.2 (4.34) 19.1 (0.75) 5.90 (13.00) BBU350 4 122.9 (4.84) 19.8 (0.78) 4.99 (11.00) BBU400 Threaded Thermoplastic 150 C Temperature Rating 1/2 26.9 (1.06) 10.4 (0.41) 0.36 (0.80) BBU50H 3/4 33.3 (1.31) 10.4 (0.41) 0.41 (0.90) BBU75H 1 39.6 (1.56) 14.2 (0.56) 0.82 (1.80) BBU100H 1-1/4 48.5 (1.91) 14.2 (0.56) 1.27 (2.80) BBU125H 1-1/2 55.6 (2.19) 14.2 (0.56) 1.50 (3.30) BBU150H 2 68.3 (2.69) 16.0 (0.63) 2.00 (4.40) BBU200H 2-1/2 81.0 (3.19) 18.3 (0.72) 6.49 (14.30) BBU250H 3 97.5 (3.84) 19.1 (0.75) 4.99 (11.00) BBU300H 3-1/2 110.2 (4.34) 19.1 (0.75) 6.49 (14.30) BBU350H 4 122.9 (4.84) 19.8 (0.78) 8.48 (18.70) BBU400H 2243

Insulated Grounding s for Threaded Rigid Metal Conduit and IMC GIB-LS-AC and GIB-L-AC Series - with Aluminum Lay-In-Lug for Copper or Aluminum Conductors. GIB-LS-BC and GIB-L-BC Series - with Bronze Lay-In-Lug for Copper Conductors Only. Wire Size Trade Size Min. Max. A B C Turning Radius w/lug Aluminum Lug Bronze Lug 1/2 14 SOL 4 STR 35.8 (1.41) 11.2 (0.44) 30.2 (1.19) GIB-50L-4AC GIB-50L-4BC 3/4 14 SOL 4 STR 36.6 (1.44) 12.7 (0.50) 33.3 (1.31) GIB-75L-4AC GIB-75L-4BC 1 14 SOL 4 STR 44.5 (1.75) 14.2 (0.56) 36.6 (1.44) GIB-100L-4AC GIB-100L-4BC 1 14 SOL 2/0 STR 44.5 (1.75) 14.2 (0.56) 42.9 (1.69) GIB-100L-20AC GIB-100L-20BC 1-1/4 14 SOL 4 STR 54.1 (2.13) 16.0 (0.63) 41.4 (1.63) GIB-125L-4AC GIB-125L-4BC 1-1/4 14 SOL 2/0 STR 54.1 (2.13) 16.0 (0.63) 35.8 (1.41) GIB-125L-20AC GIB-125L-20BC 1-1/2 14 SOL 4 STR 58.7 (2.31) 17.5 (0.69) 44.5 (1.75) GIB-150L-4AC GIB-150L-4BC 1-1/2 14 SOL 2/0 STR 58.7 (2.31) 17.5 (0.69) 50.8 (2.00) GIB-150L-20AC GIB-150L-20BC 2 14 SOL 4 STR 71.4 (2.81) 19.1 (0.75) 50.8 (2.00) GIB-200L-4AC GIB-200L-4BC Commercial Products 2 14 SOL 2/0 STR 71.4 (2.81) 19.1 (0.75) 57.2 (2.25) GIB-200L-20AC GIB-200L-20BC 2-1/2 14 SOL 4 STR 85.9 (3.38) 22.4 (0.88) 57.2 (2.25) GIB-250L-4AC GIB-250L-4BC 2-1/2 14 SOL 2/0 STR 85.9 (3.38) 22.4 (0.88) 63.5 (2.50) GIB-250L-20AC GIB-250L-20BC RIGID AND IMC FITTINGS 2-1/2 6 STR 250 STR 85.9 (3.38) 22.4 (0.88) 62.7 (2.47) GIB-250L-25AC GIB-250L-25BC 3 14 SOL 4 STR 103.1 (4.06) 33.3 (1.31) 66.8 (2.63) GIB-300L-4AC GIB-300L-4BC 3 14 SOL 2/0 STR 103.1 (4.06) 33.3 (1.31) 71.4 (2.81) GIB-300L-20AC GIB-300L-20BC 3 6 STR 250 STR 103.1 (4.06) 33.3 (1.31) 84.1 (3.31) GIB-300L-25AC GIB-300L-25BC 2244

Insulated Grounding s for Threaded Rigid Metal Conduit and IMC GIB-LS-AC and GIB-L-AC Series - with Aluminum Lay-In-Lug for Copper or Aluminum Conductors. GIB-LS-BC and GIB-L-BC Series - with Bronze Lay-In-Lug for Copper Conductors Only. Wire Size Trade Size Min. Max. A B C Turning Radius w/lug Aluminum Lug Bronze Lug 3-1/2 14 SOL 4 STR 114.3 (4.50) 25.4 (1.00) 73.2 (2.88) GIB-350L-4AC GIB-350L-4BC 3-1/2 14 SOL 2/0 STR 114.3 (4.50) 25.4 (1.00) 77.7 (3.06) GIB-350L-20AC GIB-350L-20BC 3-1/2 6 STR 250 STR 114.3 (4.50) 25.4 (1.00) 88.9 (3.50) GIB-350L-25AC GIB-350L-25BC 4 14 SOL 4 STR 131.8 (5.19) 26.9 (1.06) 79.5 (3.13) GIB-400L-4AC GIB-400L-4BC 4 14 SOL 2/0 STR 131.8 (5.19) 26.9 (1.06) 85.9 (3.38) GIB-400L-20AC GIB-400L-20BC 4 6 STR 250 STR 131.8 (5.19) 26.9 (1.06) 96.8 (3.81) GIB-400L-25AC GIB-400L-25BC 5 14 SOL 4 STR 153.9 (6.06) 31.8 (1.25) 92.2 (3.63) GIB-500L-4AC GIB-500L-4BC 5 14 SOL 2/0 STR 153.9 (6.06) 31.8 (1.25) 98.6 (3.88) GIB-500L-20AC GIB-500L-20BC 5 6 STR 250 STR 153.9 (6.06) 31.8 (1.25) 109.5 (4.31) GIB-500L-25AC GIB-500L-25BC 6 14 SOL 4 STR 184.2 (7.25) 33.3 (1.31) 108.0 (4.25) GIB-600L-4AC GIB-600L-4BC 6 14 SOL 2/0 STR 184.2 (7.25) 33.3 (1.31) 112.8 (4.44) GIB-600L-20AC GIB-600L-20BC 6 6 STR 250 STR 184.2 (7.25) 33.3 (1.31) 124.0 (4.88) GIB-600L-25AC GIB-600L-25BC 2245