Special Purpose Fuses

Similar documents
Special Purpose Fuses

Special Purpose Fuses

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Cylindrical fuse-link

Fuse switch-disconnectors

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Fuse switch-disconnectors

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

LV HRC fuse switch-disconnectors

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

MS General Information Extended Product Type: MS

FUSE BASES NH FUSE BASES 690V 160A 160A

K50H004UP cam changeover switch - 4-pole A - screw mounting

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

K30H001YP cam star-delta switch - 3-pole A - screw mounting


MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Low voltage NH knife-blade fuse-links

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Application Mini Contactors for Motors and Resistive Loads

TAE pole Contactors

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Cylindrical fuse-link

Electronic overload relays EF205 and EF370

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

Thermal Overload Relays - WEG RW Series, 2 Pole

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Horizontal fuse disconnects

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Fuse switch disconnectors

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

LINOCUR Size D02 63A 230VAC/440VAC

ASL09..S 3-pole Contactors - Spring Terminals

Micro Contactor MA Series

AF40... AF96 3-pole contactors Technical data

LK Position Switches TECHNICAL DATASHEET.

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

FL series position switches

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Motorized switch-disconnectors OTM 40 to 125 Amperes

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

vertical fuse switch disconnectors

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Vertical fuse disconnects

FUSE-LINKS GAUGE PIECES FUSE BASES SINGLE-POLE FUSE BASES THREE-POLE FUSE BASES LOW VOLTAGE FUSES POWER NEEDS CONTROL

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Solar Installer Range. Bright solutions

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

MULTIVERT 1000A Main Incomer, 690VAC

3NP1 Fuse Switch Disconnectors up to 630 A

Varius SUMMARY OF MODELS

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

Varius SUMMARY OF MODELS

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Electronic overload relay EF65, EF96 and EF146

Application Mini Contactors for Motors and Resistive Loads

General_technical_data Series

SENTRON Switching and Protection Devices Switch Disconnectors

Thermal-Magnetic Circuit Breaker 201/-WA

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

BETA Switching Switches and Light Indicators

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

B Mini Contactor V Hz

DC-Switch Disconnectors for Photovoltaic acc. to IEC

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Fuse switch disconnectors

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Varius SUMMARY OF MODELS

Position switches FD series

Transcription:

Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si

NH DC 80 V - Telecom fuse 80 V d.c. (L/R = 0 ms) 5 ka d.c. Standards IEC 09-1 Fuse-link for battery and UPS protection. 00 [A] standard indicator Code No. striker indicator [W] 01011 9,0 50 0017 001,5 00 0018 0013 17,5 30 0019 001 8,0 800 00115 37,5 Weight [g] 3/90 173 50 00 30 800

NV Telecom fuse disconnectors type Code No. HVL 00 Telecom 1P M8-M8, front connection, for striker 00190 HVL 00 Telecom 1P M8-M8, rear connection, for striker 00191 HVL 00 Telecom 1P M8-M8, front connection 0019 HVL 00 Telecom 1P M8-M8, rear connection 00193 Technical data for NV Telecom fuse disconnectors Technical Specifications HVL 00 Electrical Characteristics Rated operational voltage U e V DC 80 DC 80 DC 80 DC 80 Rated operational current I e A 50 00 30 800 Conventional free air thermal current with fuse I th A 50 00 30 800 Rated insulation voltage U i V 0 0 0 0 Rated conditional short-circuit current - ka eff 50 50 50 50 Utilization category I e A DC 0-B/50 A DC 1-B/ A DC 0-B/00 A DC 1-B/50 A DC 0-B/30 A DC 1-B/00 A DC 0-B/800 A DC 1-B/30 A Rated impulse withstand voltage U imp kv 8 8 8 8 Operating cycles with current - - 0 0 0 0 Total power loss at I th (without TM) O v W,9 1 3 Fuse links to DIN 30 - - oo oo oo oo Max. rated current (gl/gg) A 800 800 800 800 Max. permissible power loss per fuse links P v W 1 18 8 39 Mechanical characteristics Operating cycles without current - - 500 500 500 500 Weight - kg 0,37 0,55 0,75 0,75 Cable connection Flat terminal Bolt diameter - - s. drawings Cable lug (DIN 30) - mm 150 0 0 0 Flat bar - mm 7x 8x 9x0x Tightening torque M a Nm 1-15 30-35 30-35 30-35 Type of protection Front side Operational state - - IP 0 Device fitted Front cover open - - IP Operating conditions Ambient temperature T u O C -5 to +55 Rated operating mode - - Continuous operation Actuation - - dependent manual operation Mounting position - - vertical, horizontal Altitude - m up to 000 Pollution degree - - 3 Overvoltage category - III 3

NH DC 0 V 0 V d.c. (L/R = 0 ms) 50 ka d.c. Standards IEC 09- Fuse-link for DC application. [A] Code No. 00 C 00 1 C 1 Max. power [W] 0 00100 0010 00 C 7, 3/5 5 00101 0011 00 15,1 3/90 173 3 0010 001 C 1,9 3/5 33 0 00103 0013 1 31,3 3/ 30 50 0010 001 3 001015 80 00111 001 0 0011 0017 15 00113 0018 011 0019 00 00130 50 00131 98 type dimensions [mm] A B C D E F G H K 00 C 79 53 7 35 15 1 5 7,5 00 79 53 7 35 15 8 5 1 1 C 135 8 5 0 15 8 1 1 1 135 7 5 0 0 5 1 3 5 0 3 80 0 3 50 0 15 00 50 1 0 1 3

NH DC 750 V 750 V d.c. (L/R = 15 ms) 0 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK0 DC. 0 Code No. [W] 3 001308 7, 70 370 [A] Pre-arcing (A s) (L/R=15ms) Operating (A s) (L/R=15ms) 0 0013 8,8 135 50 50 001311 11,0 50 1.000 3 00131 13,5 50 1.790 80 001313 17,0 1.050 3.000 0 00131 1,0.580. 15 001315 5,.300 1.090 0131 31, 13.00 7.0 3 80 3 50 80 15 0 3 0 5

NH DC 750 V 750 V d.c. (L/R = 15 ms) 0 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK1 DC. 1C Code No. [W] 3 001300 7, 70 370 [A] Pre-arcing (A s) (L/R=15ms) Operating (A s) (L/R=15ms) 0 001301 8,8 135 50 50 00130 11,0 50 1.000 3 001303 13,5 50 1.790 80 00130 17,0 1.050 3.000 0 001305 1,0.580. 15 00130 5,.300 1.090 01307 31, 13.00 7.0 3 300 3 50 80 15 0 3 0

NH DC 750 V 750 V d.c. (L/R = 5 ms) 5 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK1- DC. 1 Pre-arcing (A s) (L/R=5ms) Operating (A s) (L/R=5ms) [A] Code No. [W] 35 001331 5 30 50 001333 0 80 70 3 00133 5 170 1.390 80 001335 31 50.550 0 00133 0 1.30.500 15 001337 50.00 9.700 01338 55 7.880 18.370 3 90 50 80 15 35 3 0 7

NH DC 00 V 00 V d.c. (L/R = ms) 0 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK0 DC. Pre-arcing (A s) (L/R=ms) Operating (A s) (L/R=ms) [A] Code No. [W] 3 001381 7, 5 30 0 001383 8,8 9 730 50 00138 11,0 155 90 0 3 001385 13,5 90 1.70 80 00138 17,0 50 3. 0 001387 1,0 1.1 5.80 15 001388 5,.800 11.30 * 001389 31, 5.950 0.750 *900 V d.c. 3 80 3 50 80 15 0 3 0 8

NH DC 00 V 00 V d.c. (L/R = ms) 0 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK1 DC. Pre-arcing (A s) (L/R=ms) Operating (A s) (L/R=ms) [A] Code No. [W] 3 001371 7, 5 30 0 001373 8,8 9 730 50 00137 11,0 155 90 1C 3 001375 13,5 90 1.70 80 00137 17,0 50 3. 0 001377 1,0 1.1 5.80 15 001378 5,.800 11.30 * 001379 31, 5.950 0.750 *900 V d.c. 3 300 3 50 80 15 0 3 0 9

NH DC 00 V 00 V d.c. (L/R = ms) 5 ka d.c. Standards IEC 09-, IEC 09- Fuse-link for DC application. Applied in fuse base PK1- DC. Pre-arcing (A s) (L/R = ms) Operating (A s) (L/R = ms) [A] Code No. [W] 35 001351 50 50 50 001353 0 95 880 3 00135 5 00 1.800 1 80 001355 31 530 3.30 0 00135 0 1.550 5.900 15 001357 50.570 1.700 * 001358 55 9.0.0 *900 V d.c. 3 90 50 80 15 35 3 0

PCF DC 900 V d.c. 00 V d.c. Rated current max. 5 A max. 0 A Max. fuse-link power disspation 3 W Cross-section of connecting wire 0,5 mm - mm (AWG 8-0 solid) Pole build-in width 18 mm Mounting on the rail EN 0715 (EN500) Utilization category DC-0B Standards - Fuse-links IEC 09-:00, UL8- Standards - Fuse-disconnector IEC 097-1 Ed..0, EN 097-1:1999+A1:000+A:001 IEC 097-3 Ed..1, EN 097-3:1999+A1:001 Number of poles U e /U i [V] I max [A] Code No. indicator 1P 900 5 00550301-1/33 58 P 900 5 00550303 - /18 1P 900 5 00550311 LED 1/33 58 P 900 5 00550313 LED /18 1P 00 0 0055001-1/33 58 P 00 0 0055003 - /18 1P 00 0 0055011 LED 1/33 58 P 00 0 0055013 LED /18 1

Fuse base PK 1 DC U n 00 V d.c. Rated current 50 A Insulation class C-VDE01 Standard EN 09, IEC 09, DIN VDE 03, DIN 30, DIN 33 type [A] Code No. Weight [g] PK 1 50 005 3/ 598 PK 1-50 00/30 5 type dimensions [mm] A B C D E F G H I J K L M PK 1 175 80 11 81 M Ø,5 30 55 5 0 PK 1-93 0 81 M Ø,5 30 55 5 15

www.eti.si