System Connection Box. Engine Connection Box. Engine. Legend. VP Wiring. VP Supply. Yard Wiring SEM C. File Name: SEM C

Similar documents
ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

Flight Systems. Replacement for KASSEC DESCRIPTION

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE A121A / A241A

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Model H30 Operation Manual

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

DKG-109J AUTOMATIC MAINS FAILURE UNIT

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

DEEP SEA ELECTRONICS PLC

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

60 Series Engine Controls

DKG-509 AUTOMATIC MAINS FAILURE UNIT

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

GCU-10. Automatic Engine Control Unit Operators Manual

DKG-109 AUTOMATIC MAINS FAILURE UNIT

Service Bulletin Trucks

DEEP SEA ELECTRONICS PLC

ANALOG CONTROL PANEL

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Rev 29. Caution

12,78 779, Bore , ,22 Compression ratio. 18,1:1 Wet weight. Engine incl. cooling system, air filtration system, and frame

7,15 436, Bore , ,12 Compression ratio 18 Wet weight. Engine incl. cooling system and air filtration system

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

7,15 436, Bore , ,12 Compression ratio. 17 Wet weight

7,15 436, Bore , ,12 Compression ratio. 18 Wet weight

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Installation Instructions

Telephonic Car Alarm and Remote Starter Wiring Schematics

Engine incl. cooling system and air filtration system Engine incl. cooling system, air filtration system, and frame. Standby Power

Senior Swing Control Box. Table of Contents

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

VARIFAN ELECTRONIC TEMPERATURE/ SPEED CONTROLS

Lotus Service Notes Section MVc

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

Option M4 Engine control and protection Functional description Modes and sequences General product information PID controller Additional functions

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

with discrete output (Overspeed) with auxiliary input (Synchronizer and Load Sharing)

INSTALLATION INSTRUCTIONS

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

ICON 2 1. FEATURES AND CHARACTEIRICS

GSC300 Auto Start Engine Controller

Engine incl. cooling system and air filtration system Engine incl. cooling system, air filtration system, and frame. Standby Power.

Application Engineering

HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL

4,76 290,7 Firing order Bore

Generator Sets Controller 210. Operation Manual. Ver1.0

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.6

DKG-114 MANUAL AND REMOTE START UNIT

BLOWER VACUUM SWITCH FAILED OPEN

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Alarms, remote indications and safeguards for main reciprocating I.C. engines installed in unattended machinery spaces

DPS Telecom Your Partners in Network Alarm Management

KNC-SRV-FD123-CA-000 Series Servo Driver

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.5

PowerCommand 1.2 control system

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

KNC-SRV-FD123-EA-000 Series Servo Driver

Technical data TAD1641GE

Caddy/Polo Classic. Current Flow Diagram No. 3 / 1. Edition Glow plug relay (104)

6 Displacement, total Compression ratio 16,5:1 Dry weight. Engine only, excluding cooling system GenPac

Technical data TAD1642GE

Audi A4 Fitting Locations No. 803 / 1

PSM72H Push-Button Start Module

EPM72 Engine Protection Module

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Technical data TAD1641VE

DKG-317 MANUAL AND REMOTE START UNIT

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

Auto Mains Failure AMF Controller AE10113

HGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology

PowerCommand 2.2 control system

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Deep Sea Electronics Plc

Designed for ease of integration with automation systems

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

GENSET CONTROL MODULE

Komatsu Power Generation Systems

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

TG410 User Manual. Manual Revision: Min. FW Revision: Date Released: 18/12/ DynaGen Technologies Inc

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

DKG-215 MANUAL AND REMOTE START UNIT

Technical data TAD1353GE

GSC300 Auto Start Engine Controller

Transcription:

Modbus on RS To yard System Connection Box Marine Control Unit MCU Potential free relay contacts X... X6 Signals from VP system to yard IDCOM Shut Down Unit SDU Terminal Block X9 Signals to VP system from yard Power Module PM Engine Shut Down Switches Fuel Valve Engine Connection Box Legend VP Wiring Engine Sensors EMS Terminal Block X0 VP Supply Shut down Reset Yard Wiring 4VDC Main voltage supply 4VDC Backup voltage supply Yard Supply Page Title: Single line diagram System layout Date For Last Change: 00809 0:57:4 Page of 8

Inputs X9 B6 B7 B8 B9 B0 B B B B4 Customer Interface A5 A5 All terminals X through X9 are located in the system connection box mounted on a bracket at the rear of the genset. Optional rpm signals from load sharing and synchr. units. Implemented by Volvo Penta on request Contacts for speed up and down (default) Voltage: ±V Resistance: 050 Ohm, 0.4 kohm Current: ±0 ma Outputs SD Override Idle Start blocking Acknowledge Blackout start Remote start Remote stop Speed up Speed down Potential free relay contacts X X X X4 X5 X6 X7 X8.5 Shutdown override function All shutdown's (SDU input's SS5) possible to override except overspeed shutdown, which are not possible to override 5.4 EMERGENCY STOP (OPTIONAL) Yard supply SD override indication Local Mode Indication Disconnect Genbreaker EMS communication failure Start Failure Alarm Potential free relay contacts Horn Common shut down Common alarm Max 4VDC, 0VAC not allowed, on relay contacts X9 X0 X X X X4 X5 X6 Not controlled by the MCU. Use as general purpose relay Not controlled by the MCU. Use as general purpose relay For internal use (SD override) Disconnect wires 4 and and use relay as spare Disconnect wires 4 and and use relay as spare Engine running Ready to start Ready to take load Page Title: Customer Interface Date For Last Change: 00 7:0:4 Page of 8

System Connection Box 4. RB 5. BZ A5 A5 5.5 EA 5.4 DA 5. LA 5. KA 5.9 5..5,4.8,4.,5. 5.8 5. 5.7 B6 B7 5.7 B8 B9 5.7 B0 B 5.7 B B 5.7 B4 5.9 X9 A5 A5 EA DA LA KA B6 B7 B8 B9 B0 B B B B4 X9 A5 A5 EA DA LA KA B6 B7 B8 B9 B0 B B B B4 EA 6.4 DA 6. LA 6.9 KA 6.0 6.5 Speed down Speed up Remote stop Remote start Blackout start Acknowledge Start blocking Idle SD Override Page Title: User inputs, X9 terminals Date For Last Change: 09 08:8:04 Page of 8

System Connection Box Common alarm Common Shut down Horn Start Failure Alarm EMS Communication Failure Disconnect Genbreaker Local Mode Indication SD override indication X7 X X X X4 X5 X6 X7 X8 X8 5..5 BO9 5.8 9 SL 5.4 BO0 5.9 0 BO 5.9 BO 5.8 BO 5.8 BO 5.9 4 BO4 5.9 BO 5.8 5 BO5 5.8 BO4 5.9 4 6 BO6 5.9 5 7 BO7 5.8 6 8 BO8 5.9 X9 X0 X X X X4 X5 X6 Not controlled by the MCU Use as general purpose relay Not controlled by the MCU Use as general purpose relay OR 5. RB. Disconnect wires 4 and use relay as spare Disconnect wires 4 and and use relay as spare Engine running Ready to start Ready to take load SD override (Not for yard use) Page Title: Potential free contacts Date For Last Change: 09 08:0: Page 4 of 8

System Connection Box.7,6.5 4.8 SL 4 SL OR 4.. OR 4..4 BZ 5.0 BZ Buzzer MCU jumper settings Current mode: Voltage mode: Resistance mode: 4 Jumper is the most inner one and jumper 4 is the one closest to the edge of the circut board.6 IDCOM * SF SB OS 0 9 8 7 Shut Down Unit SDU T SA 66 65 S6 S5 S4 S S S 66 6.4 65 6. S 6.9 S 6.7.6,5. 4.8 BO 4.8 BO5 4.8 BO7.7 4.7 BO 4.7 BO4 4.7 5. BO6 BZ RPM RPM IN BI BI BI BI4 BI5 BO BO BO BO4 BO5 BO6 BO7 MCU A A A A4 A5.6 SHIELD COM AIN AIN AIN AIN4 AIN5 AIN5 AIN6 AIN6 AIN7 AIN7 AIN8 AIN8 BI6 BI7 BI8 A5.7 A7 A8 A7 A8 B7.9 B6.8 B8.0.0 LA L COM. KA H.9 DA B COM.8 EA A L COM CAN J708 CAN IDCOM H 4.7 BO8 BO8 BI9 B9. S S S S4 S5 S6 POWER OVERSPEED RUNNING S4 RUNNING S, S SHUTDOWN ALARM OR Shut Down Override Shut Down Reset SA Shut Down Acknowledge SB Shut Down Buzzer SF Broken Wire Alarm OS Overspeed SL Shut Down Lamp RESET BROKEN WIRE BROKEN WIRE ALARM OVERSPEED TEST FV RPM S6 S5 S4 S S S 4. BO9 4. BO 4. BO 4. BO0 4. BO 4. BO4 BO9 BO0 BO BO BO BO4 BI0 BI BI BI BI4 B. B.5 B0. B.4 B4.6.4. D RS Page Title: MCU, SDU and IDCOM Date For Last Change: 00 0:5:44 Page 5 of 8

Engine Connection Box.7,5.4 5. S 5. S 5. 65 5. 66.0 LA. KA.9 DA.8 EA.6 X0 S S S S4 S5 S6 65 66 LA KA FA DA EA X0 S S S S4 S5 S6 65 66 LA KA FA DA EA 0k 0k B 7.5 LA 8.0 KA 8. B 7.5 FA 8. DA 8. EA 8.4 Fuel stop valve Coolant temperature Shut down switch Lub oil pressure Shut down switch Speed pickup 4 4 Shutdown Reset Page Title: Terminals X0 Date For Last Change: 005 09:6:0 Page 6 of 8

Electric Starter 6.8 B Power Module PM 6. B 8.6 50 8.5 50 Optional starter contact S 68 Ohm, 7 W D The connection for Backup voltage supply is located on the right hand side of the engine below the start motor (red) is positive (black) is negative STARTER M = B B G = Emergency stop!6a FUSE Yard supply Alternator Alternator: Optional, Customer choice TO EMS TO EMS Engine 4VDC Main voltage supply 4VDC Backup voltage supply Page Title: Voltage supply, Electric Starter Date For Last Change: 00 0::06 Page 7 of 8

Engine 6.9 LA 6.0 KA 6. FA 6. DA 6.4 EA 7.0 50 7.9 50 Fuel pressure p Crank case pressure p Cyl 6 Coolant pressure p Cyl 5 Engine Management System EMS Cyl 4 Piston cooling pressure p Cyl Exhaust temp. t Cyl Coolant temp. t Cyl p,t p,t p L L L L Oil level Coolant Level Water in fuel (B) Water in fuel (A) Sea water pressure Boost temp & pressure Oil temp & pressure Crank speed Engine speed cam shaft Page Title: Engine sensors and EMS Date For Last Change: 00 7:06:00 Page 8 of 8