POW72V35A/BMS CHARGER SPECIFICATION

Similar documents
GWL/ Power Group Technology Solutions Stay Powered for the Future

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW48V10A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW24V20A-D1 Charger. LFP/LTO + BMS connector

Specification of Battery Charger

GWL/ Power Group Technology Solutions Stay Powered for the Future

Specification of Battery Charger

Specification of Soneil Battery Charger

Specification of Soneil Battery Charger

SPECIFICATIONS LOW COST 2404R CHARGER

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

SPECIFICATIONS SR CHARGER

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

SPECIFICATIONS SR

SPECIFICATIONS SRL CHARGER

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Energy Storage System for Home

SPECIFICATIONS SRF

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Cellwatch Battery Monitoring Systems

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

GB60S 60W Single Output General Purpose Series

All In one uninterruptible power supply solutions

Open Frame Power Supplies

SPECIFICATIONS SRF SuperchargerPlus

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Emergency lighting units PC COMBO

GWL/Power GWL/Power i4wifi a.s.

Model Number Structure

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

C B. Operating up to 5000m altitude 5 year product warranty Models

Emergency lighting units PC COMBO

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Scheda prodotto Relè Series E

Amperis battery regenerator

Indoor Linear 50W Driver SI-CU WW

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

EMO-21. Specifications. Elcom International Pvt. Ltd. Approvals: Screw mounting IEC outlet. Terminals: 6.3 mm Quick Disconnect Tabs.

Top Microsystems Proprietary Specification P/N: A190047LV6 FSM RB VA.1 SPECIFICATION

AC/DC Converter MBP250-2A13D13M

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

SPECIFICATION FOR VH F CONTENTS

ISTEK-C A 750V DC Contactor

TrustSight LED Emergency Lighting

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Features. Description. Table of Contents

Scheda prodotto Relè Series B

GWL/Power GWL/Power i4wifi a.s.

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

2012 Battery Chargers Program

Series AM1G-NZ 1 Watt DC-DC Converter

LFP(12-16 ( CE

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Input Current at 240V (A) Max. Input Power (W) Enclosure

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Max. Input Power (W) Input Current V Isolated DALI

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

DART Charger Product Description, Information and Specification

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SPECIFICATIONS LOW COST 2404S CHARGER

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

InteliCharger V 20A Intelligent Automatic Battery Charger

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

Switching Power Supplies

The Battery Saving Charger

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

X600. Technical Sheet

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Application. Battery. Public Grid GS HYBRID INVERTER

ZWD100PAF. Conformity to RoHS Directive

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Emergency lighting units EM powerled

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

EMC Filter FC-CxxD Series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

PRODUCTS: POWER SUPPLY

Emergency lighting units EM powerled

Emergency lighting units EM converterled

Emergency lighting units EM converterled

User Manual. 3/1 10K~30K Online UPS

Transcription:

POW72V35A/BMS CHARGER SPECIFICATION 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage 47-63 Hz frequency 1-4 Inrush current < 100 A A @ 264Vac start-up in cold condition 1-5 Max input current 16 A A 2. Output characteristics 2-1 Nominal charge voltage 72V Vdc 24 cells @ 3.00V 6 batteries @ 12.00V 2-2 Fast charge voltage (V-max) 88V Vdc 24 cells @ 4.00V 6 batteries @ 16.00V 2-3 Maintain voltage 88V Vac (Float voltage, same as V-MAX) 2-4 Constant current 35A A Maximal current during full charge (I-CC) 2-5 Deep voltage level (V-deep) 65V Vac Deep discharge voltage level, bellow this voltage, the current is limited to I-min 2-6 Deep discharge 8A A The limited current bellow V-Deep current (I-min) 2-7 BMS limit current (I-BMS) 3A A The limited current for cell balancing (controlled by BMS) 2-8 Power efficiency >80% @ 230Vac 3. Protection characteristics 3-1 Output over voltage 104 V Vdc protection 3-2 Software over voltage protection The charger software limits the maximum output voltage to a level suitable for the connected battery system 3-3 Thermal cutback The internal monitor reduces the charger output power in extreme operational to prevent damage 3-4 Output current limiting protection 3-5 Output short circuit protection 3-6 Electronic reverse battery protection 40 A A @ CC Mode Short circuit protection at the output terminals. Automatic recovery after restoring to normal conditions. The charger is electronically protected against permanent reversed battery connection.

4. Charge indicator (LED) 4-1 Deep charging LED flashing (slow) 4-2 Fast charging LED flashing (fast) 4-3 Complete charge LED on 4-4 Voltage indicator LED display (00.00 to 99.99) V Not calibrated measuring, 4-5 Current indicator LED display (00.00 to 99.99) A indication only 5. Safety & EMC (CE Conformity Requirements) 5-1 Electric strength test input output 1500 V / 10 ma /1 minute Vac No breakdown 5-2 Isolation resistance > 10 MOhm @ 500 Vdc MOhm Input ground () 5-3 Isolation resistance > 10 MOhm @ 500 Vdc MOhm Output ground () 5-4 Leakage current < 3.5 ma A Vin = 264Vac, 50-60 Hz 5-5 Safety EU standards for CE MARK small electrical appliances 5-6 EMC RE Class B EN55014 5-7 EMC CE Class B EN55014 5-8 EMC air discharge Level 3 EN61000-4-2 (dis. B) 5-9 EMC contact discharge Level 3 EN61000-4-2 (dis. B) 5-10 EMC RS Level 3 EN61000-4-6 (dis. A) 5-11 EMC CS Level 3 EN61000-4-3 (dis. A) 5-10 EMC EFT Level 3 EN61000-4-4 (dis. B) 5-10 EMC Surge Level 3 EN61000-4-5 (dis. A) 1 kv, 2 kv (dis. B) 6. Environmental test requirements 6-1 High ambient operating +40 C deg C continuous operation 6-2 Low ambient operating -10 C deg C continuous operation 6-3 Highest storage +70 C deg C allow 2 hours to recover to normal 6-4 Lowest storage -40 C deg C allow 2 hours to recover to normal 6-5 Drop shock 40 g peak EN60068-2-32:1993

7. Charging curve (current A red, voltage V - blue)

8. BMS connector operation VC12V the charger works the standard way at MAX power VC12V +12V the charger works the standard way at MAX power VC12V +12V the charger stops working any VC12V +12V the charger works the standard way at REDUCED power (10%)

9. Product photos A (The delivered product may differ from the image)

9. Product photos B (The delivered product may differ from the image) EV-Power.eu managed by i4wifi a.s. (member of GWL/Power group) Prumyslova 11, CZ-10219 Prague 10, CZECH REPUBLIC (EU) phone: +420 277 007 500, fax: +420 277 007 529, email: export@i4wifi.cz