V200 USER MANUAL SWING GATE OPENER 100kg 1.m 100kg 1.m
Content Important Safety Advice... Content of the Kit... Connection Diagram... Installation Guide... Actuator... Control box... AC cable wiring... Transformer... Connection PCBA... Actuator... Warning light... Photocells... Function of photocells... Opening/Closing learning... Remote learning... Remote control... Auto close function... Manual gates control on the PCBA... Clear RF memory... Reset... Setting of the Dip Switches... Specifications... Declaration of CE Conformity... 03 03 03 0 0~07 08 09 10 11 12 13 1 1 16 16 17 17 17 17 17 18 19 20 2
Important Safety Advice 1. Knowledge of relevant electro-technical regulations is required. 2. Training in use and maintenance of safety equipments is necessary. 3. Professional assistance is required when some mechanism adjustment is needed.. Always lay mains and control cables separately.. Test every equipment before initial operation. 6. Make familiar with the use of the system before initial operation. Content of the Kit x2 Gate side brackets x2 Actuator x2 Pivot part for actuator x2 Pillar side brackets Control box x2 Remote control Warning light Battery wire Wire conduit (PG11) Connection Diagram Warning light Control box Photocells Photocells Actuator Actuator 3
Installation Guide Actuator: The maximum opening angle depends on the distance (D) between the gate hinge to the edge of the pillar. The table below gives the opening angle according to (D) Pillar Angle (º) 90 Distance D (mm) D < 180 D Angle 100 0 < D < 110 Pillar D 1 2 3 B Angle max. (º) 90 9 100 Distance D (mm) Distance B (mm) The bracket holes (Gate side bracket) The bracket holes (Pillar side bracket) 180 170 160 10 10 130 120 110 100 90 6 70 7 80 8 9 9 100 1 1 1 1 1 1 1 2 2 2 80 10 3 70 10 3 60 110 0 110 0 11 30 120 20 120 10 120 0 120 IMPORTANT: If the hinge of your gate is more than 180mm from the edge of the pillar, it is necessary to adapt the pillar to ensure the hinge is less than 180mm from the edge of the pillar, to reach a 90º opening. hinge pin hinge pin Pillar Pillar > 180mm INCORRECT mm = 180mm CORRECT
Pillar side: Find the desired value B, according to the value D, as described in the previous table explaining the opening angle. Make sure the pillar side bracket is placed horizontally, with the use of a spirit level, before you drill the holes for the bracket. Use a spirit level to be sure that the mounting bracket can be placed horizontally. 16mm B
Gate side: Make sure the gate side bracket is placed horizontally, with the use of a spirit level, before you drill the holes for the bracket. Use a spirit level to be sure that the mounting bracket can be placed horizontally. Put the fixing bolt downwards through the hole of the actuator, and the hole of the pillar side bracket. And use the snap pin to keep them in place. 3 2 1 Fasten the wing nut in this direction. 6
Normally the nut is at a distance of mm from the fully close position. You can drive the nut to this position, in case the nut is not at the proper position. - Move the nut with a battery. The below diagrams indicate which direction the nut moves when the motor wires are connected directly to a 12VDC battery. Black Red 0mm mm Black bottom view Red 7
AC12V 1 2 3 6 LED1 Auto RF2 Clear J1 LED O/C1 O/C2 GND ANT O / C Lamp RF1 AC12V 1 2 3 6 LED1 J1 O / C Lamp Auto RF2 Clear RF1 Control box: 1. Use a screw driver to unfasten the screws of the cover and open the control box. 2. Unfasten the two screws and remove the cover. BAT - + -M2+ -M1+ -Warm+ +12V COM GND NC LED O/C1 O/C2 GND ANT 3. Fix the control box on the wall. M8 screws are suggested (not provided). BAT - + -M2+ -M1+ -Warm+ +12V COM GND NC Min. 60cm 8
1 2 3 6 1 2 3 6 1 2 3 6 AC cable wiring: Connect the AC cable as shown below. 1. Mount the wire conduit at the left side of the control box. AC12V BAT - + Auto RF2 Clear RF1 LED1 -M2+ -M1+ -Warm+ +12V COM GND NC J1 LED O/C1 O/C2 GND ANT O / C Lamp 2. AC cable goes at the left side of the control box through the wire conduit. AC12V BAT - + Auto RF2 Clear RF1 LED1 -M2+ -M1+ -Warm+ +12V COM GND NC J1 LED O/C1 O/C2 GND ANT O / C Lamp 3. Connect the AC plug to the power AC12V and check th if the LED on the board is. BAT - + Auto RF2 Clear 1 2 3 6 RF1 AC12V BAT - + Auto RF2 Clear RF1 LED1 LED -M2+ -M2+ -M1+ -Warm+ +12V COM GND NC J1 LED O/C1 O/C2 GND ANT O / C Lamp -M1+ -Warm+ +12V COM GND NC J1 LED O/C1 O/C2 GND ANT O / C Lamp BAT *If the LED is, remove - + the AC plug, and put back the cover of the transformer. AC12V Auto RF2 Clear 1 2 3 6 9 RF1
1 2 3 6 1 2 3 6 Transformer: AC12V BAT - + Auto RF2 Clear RF1 -M2+ -M1+ -Warm+ +12V COM GND NC J1 LED1 LED O/C1 O/C2 GND ANT Put back the cover. O / C Lamp Use a screw driver to fasten the 2 screws of the cover. AC12V BAT - + Auto RF2 Clear RF1 LED1 -M2+ -M1+ -Warm+ +12V COM GND NC J1 LED O/C1 O/C2 GND ANT O / C Lamp Use a screw driver to fasten the screws of the control box. 10
PCBA: To transformer (12V AC) To backup battery (12V DC)(Option) Dip Switches AUTO RF 2 Clear RF 1 + Red - Black + Red - Black Motor connection See P.11 Remove this jumper when photocells are connected. Put this jumper back if photocells are removed. Photocells connection See P.13 Warning light connection See P.12 Dual-gate operation manual button Single-gate operation manual button For external LED display To external dual-gate operation To external single-gate operation Antenna 11
Actuator: Connect the four wires on the connector -M2+ -M1+. Motor 1 Motor 2 Motor 1 Motor 2 Black Red Black Red Red Black Red Black -M2+ -M1+ -M2+ -M1+ Inward opening Outward opening For gates that open inwards, as shown below, connect the motor wires according to the diagram above. For gates that open outwards, as shown below, connect the motor wires according to the diagram above. M1 M2 M1 M2 12
Warning light: 1. Open the warning light, in this direction. 2. Remove the screws. 3. Connect the warning light wires in the connector.. Fix the warning light on the pillar. (screws not provided).. The warning light wires come out from here. (wires not provided). 6. Close the warning light in this direction. 7. Connect the two wires on the connector -Warm+. (wires not provided) -Warm+ 13
Photocells (optional): See the picture on the right for installation. Fix the photocells on the pillar. Min. 30cm Connect the wires following the below diagram. (wires not provided) IPH6 IPH1 PHOTOCELL TX +12VGND PHOTOCELL RX +12VGNDCOM NC / OR / PHOTOCELL TX PHOTOCELL RX +12V COM GND NC +12V Sensor +12V COM GND NC The short wire connecting GND and COM is not provided. +12V Sensor 1
Function of photocells: Select a proper installation site, where the transmitter and receiver can align well. Connect to the opener s PCBA as wiring diagram on page 13. Power on the system, try and see if it works properly by intercepting the IR between transmitter and receiver for times. The relay in the receiver should respond accordingly while LED switches and OFF. During Opening: When the loop of photocells is intercepted, system will: A. ignore, if Motor 2 is activated. OR B. half, if Motor 2 is not activated. During Closing: When the loop of photocells is intercepted, the system will stop closing the gate and then to open both leaves simultaneously until the set position. Before Opening and closing: Both leaves of the gate won t move until the photocells are well-aligned. *For IPH6, please note the following, TX RX This jumper is by default NC. Do not change at will or the system might not function correctly. 1
Opening / Closing learning: Please proceed with this function before using this product; otherwise the system will drive the gates improperly. E.g.: The gate can t close completely or can t open to the intended degree with some stroke length left unused. To activate this function, press Auto button on the PCBA until it starts the learning mode as below: - The system will close the gates first. Please remove any obstacles that could possibly block the gate. Before the motors start, the warning light will blink first. Then Motor 2 will close first, and then Motor 1 will close 1 second later. - Both M1 and M2 will take turn opening, and closing, and they will move together again, until they reach the fully stop position. - The warning light will stop blinking once the auto-learning finishes. - After the learning process succeeds, the system is ready for use. AUTO NOTE: The Opening/Closing Learning might not be done successfully due to the over-weight of the gates. Then, the Current Limit needs to be adjusted. Please refer to P10 of this manual. If any assistance is needed, please contact the technicians of our agent. Remote Learning (activation of remote control for gate operation) To activate the remote control, please proceed with the following steps: A. RF dual-gate learning (dual-gate operation): - Press RF2 key on the PCB for over 2 seconds while the PCB is on. - You ll see the LED light on (learning mode entered). Please press any key on the remote controls. LED will now blink for 3 times (learning succeeds) or light is off after 10 seconds without blinking. (learning fails, please try again the whole process). - Please repeat Step 1 and 2 to activate another remote control; otherwise the unlearnt remote control won t be recognized by the system. B. RF single-gate learning (single-gate operation): - Proceed with RF1 key on the PCB and another key on the remote control as Step 1~3 above. RF 2: Dual-gate RF 1: Single-gate 16
Remote Control: Each remote control has keys. Choose two of them to proceed with RF learning for gate control and garden lamp control separately. Operation (open, close and stop) by remote control: The remote operation is very simple: one key press on the key will open the gate, the next press to stop, next to close the gate, the next to stop...and so on. When the gate is opening: - The warning light will blink first, then Motor 1 opens, and later Motor 2 opens. - If the gate hits something, motor will reverse a little with the warning light blinking until the next com mand received. When the gate is closing: - The warning light will blink first, then Motor 2 closes, and later Motor 1 closes. - If the gate hits something, motors will reverse for 3 seconds with the warning light blinking until the next command received. Auto close function: 30 seconds or 60 seconds later (only when this function is enabled, depending on your setting of key 1 of dip switch), the warning light will blink first, then Motor 2 closes, seconds later Motor 1 closes. When the process finishes, the warning light will be switched off. Manual gates control on the PCBA: - The operation is the same as using remote, one key press will open the gate, next to close the gate, next to stop...and so on. - Optional remote controls or external wall button is available. (Connected to O/C & GND terminals) Clear RF memory: Press Clear key on the PCBA for over 2 seconds while the PCB is on. You ll see the LED blinking times then the RF memory will be cleared. Reset: Press Clear key on the PCB and input AC power; keep pressing Clear key for over 2 seconds. You ll see the LED blink for 2 seconds and light on for 3 seconds then light off. Once the mentioned actions are carried out, all RF data willl be cleared. AUTO RF 2: Dual-gate Clear RF 1: Single-gate Single-gate operation manual button Dual-gate operation manual button 17
Setting of the Dip Switches: 1 2 3 6 Current limit Gate Type Auto-Close timer Auto-Close The default setting of dip switches: Key No. Function OFF 1 Auto-Close Yes No 2 Auto-Close timer 60 Sec 30 Sec 3 Gate Type Heavy Gate Light Gate ~ 6 Current Limit Selected Unselected *Do not change the setting of Gate Type unless you have problem finishing the auto-learning process. Approx. current limit values for different dip switch setting: Switch 1.A Switch 2.7A Switch 6.0A 1 2 3 6 Maximum current limit (means also the worst sensibility, which could shorten the life of motor, please try lower current limit first) Second highest current limit. 1 2 3 6 Minimum current limit. 1 2 3 6 18
Specifications Actuator: Model Input voltage Power consumption Macimum gate weight Macimum gate width Speed Duty cycle Overload protection Strock length Protection V200 12V DC 1.0 ~ 2.A 100Kg Max. x 2 1.M x 2 23.mm/sec (no load) 20% Current detection 329mm IP Control box: Model Input Output RF Remote Recharging function Approx. weight Dimension GCG1-SWD2 110 / 230V AC ; 60 / 0Hz 12V DC / 72W Max. 33.92MHz w / Rolling code Built-in (12V DC battery is optional) 2.6Kgs 220(L) x 20(W) x 90(H) mm 19
Declaration of CE Conformity The purchased gate opener kit V200 is compliant with the following regulations, in terms of the essential conformity requirements of the R&TTE directives of 201/3/EU and related directives, - EN30189-1 V1.9.2, 2011 - EN30189-3 V1.6.1, 2013 - EN300220-1 V2..1, 2012 - EN300220-2 V2..1, 2012 also based on the essential conformity requirements of EMC Directive of 201/30/EU - EN01-1: 2006 + A1: 2009 + A2: 2011 - EN01-2: 1997 + A1: 2001 + A2: 2008 - EN61000-3-2: 2006 + A1: 2009 + A2: 2009 Class A - EN61000-3-3: 2013 and in terms of the provisions of the relevant specific standards and the Directive 201/3/EU. - EN6033-1, 2012 - EN6033-2-103, 2003 + A11: 2009 - EN6090-1:2006+A11:2009+A1:2010+A12:2006+A2:2013 20