sl. No Description Unit Qty Rate (Rs) Amount (Rs)

Similar documents
1 SITC of Surge protector OBO BETTERMAN V25-B+C/3+NPE with manufacturer's enclosure, 3 phase 415 V. no 1. No 1

SCHEDULE OF QUANTITY

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ)

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

PART B: FINANCIAL BID

TENDER DOCUMENT PART-II

PART A: FINANCIAL BID

SCHEDULE OF QUANTITIES OF ELECTRICAL WORKS FOR BOI, ZO, JODHPUR. PART - II

STATE BANK OF INDIA INFRA MANAGEMENT SOLUTION (P) LTD BOQ- ELECTRICAL WORKS OF KATKOL BRANCH, RBO-2, AO-7

ESTIMATE PROPOSED ELECTRICAL & ALLIED WORKS FO INDIA ONE AVIGHNA PARK, CURREY ROAD BRANCH AT C MUMBAI

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR

Amount (Rs) 1.5 sq. mm ISI marked, FR

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. PART B: FINANCIAL BID. Proposed Electrical Work For SBI Ramdaspeth Branch, Nagpur. S. NANDEDKAR & ASSOCIATES

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. CIRCLE OFFICE, AHMEDABAD STATE BANK OF INDIA, RBO-II, C.N. VIDYALAYA CAMPUS, AMBAWADI, AHMEDABAD

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

STATE BANK OF INDIA BOQ FOR THE ELECTRICAL 74 JANPATH BRANCH. S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

FORMAT-III B - ANNEXURE-III

T. No 03/ /Eldb

SBI, DHROLL BRANCH, DIST. JAMNAGAR - ELE. INST. WORK - OCT. 2018

MAIN INCOMER -1 (500 KVA TRF.)

FORMAT B (Annexure-III)

STATE BANK OF INDIA ESTIMATE FOR THE ELECTRICAL

Corrigendum-I. Bill of Quantity

Electrical BOQ for P Block Connaught Place Branch S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

FORMAT-III B - ANNEXURE-IV

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

: Material Description Quantity UOM

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

PUNE EAST ZONE - BANK OF MAHARASHTRA Kesari Wada, Narayan Peth, Pune

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

TENDER DOCUMENTS FOR ELECTRICAL WORKS STATE BANK OF INDIA

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS :

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

SCHEDULE OF QUANTITIES ITEM DESCRIPTION

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

West Bengal State Electricity Distribution Co. Ltd.


ESTIMATE: ELECTRICAL AND DATA CABLING WORK SBI Panchanan Bhawan Bhopal (M.P)

TECHNICAL SPECIFICATIONS OF PCC PANEL

KERALAM MUSEUM OF HISTORY & HERITAGE

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

Set /

ENGINEERING PROJECTS INDIA LIMITED HAL PROJECT, NASIK BOQ FOR ELECTRICAL WORKS IN PACKAGE II

Item Code Description Unit Qty Total

ZONAL OFFICE KEONJHAR ZONE

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

Section VI: List of Requirements (REVISED)

Rate. Sl No. Description of item Unit Qty

SNO DESCRIPTION QTY UNIT RATE AMOUNT MAIN PUMP 1

Polycab, Havell's pair Mtr

AN ISO 9001:2015 COMPANY

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

GRAMIN BANK OF ARYAVART

Hkkjrh; izca/k lalfkku dksf"kddksm

QUOTING SHEET BIDDER'S PRICE % QUOTE ABOVE / AT PAR / BELOW In figures

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

NOTICE INVITING QUOTATIONS

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Technical Specifications

Estimate of Under Ground Electrification Work

POLYCAB WIRES PVT. LTD.

NS Feeder pillar up to 3200A

S P E C I F I C A T I O N

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

POLYCAB WIRES PVT. LTD.

S P E C I F I C A T I O NS

novello SPN distribution boards


REGIONAL MANAGER (VADODARA REGION)

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

A. Submit manufacturer's literature and technical data before starting work.

Transcription:

Page 1 of 6 1 MAIN PANEL : Fabrication, Supply, Installation, Testing and commissioning of 415V,50 no 1 Hz, 3 phase,4 wire, Self standing, dust and vermin proof front operated, cubicle type distribution panel, made out of 16 SWG CRCA sheet fully compartmentalised, duly rust inhibited, degreasing, zinc phosphated etc; siemens grey color powder coated, with hinged and earthed front doors, heavy duty rubber gasgets, removable gland plates made out of 2 mm thick sheet steel, with appropriate rated bus bars & earth bus. The bus bars should be of suitable rated TPN aluminium, having specified normal and short circuit capacities and should be insulated with heat shrinkable color coded PVC sleeves and supported DMC/SMC pillars/pillar type busbar supports. Dimensions, design and fabrication of the entire panel should be as per standards of Kerala State Electrical Inspectorate, K.S.E.B. And Bureau of Indian Standards(with minimum of 250 mm depth). The panel drawings should get prior approval from the Bank' Electrical Engineer bee fabrication. Cable entry shall be according to site conditions. The panel comprising of the specific components as below: Incomer: One 200 A 4 pole MCCB, 35 KA(Ics), Microprocessor based, variable setting with in-built EF release, OC &SC protection, Rotary Operating Mechanism (ROM) and Outgoings 1. one 100 A, 4PMCCB 25 KA 2. Two nos. 63 A 4P MCCB 25 KA 3. Two nos, 50 A 4P MCCB 25 KA and one mulitifunction Digital meter and one set 3ph LED indication Supply, Installation, Testing and Commissioning (SITC) of factory made 3 ph. 63A, 8 no 2 way VDB double door with 63A, 4P MCCB (25 ka) as Incomer and one 40A, 3P MCB, four nos. 32 A 3P MCB & remaining 20-25A SP MCBs as out-goings. 2a b UPS output splitter DB : no 1 SITC SITC of 1 ph.63a 4 way DB double door with 63A, 2P MCB as Incomer and four 32A SP MCB as out-goings. c Splitter DB AC : no 1 SITC of factory made 3ph.&N DB with 63A 3P MCB as Incomer and two 40A 3P RCBO as out-goings. d SITC of factory made 3 ph. 4 way TPN VDB double door with 40A 4P100mA RCBO as no 1 Incomer and two 25A 3P MCB and remaining 10/16AMCBs as out-goings. ( power plugs) 4a b 5a b SITC of wall mounting type double door, dust & vermin proof 12 way SPN MCB DB no 2 comprising one 2 pole 25, 30 ma high immunity type RCBO suitable UPS operation as in comer and 6-16 A SP MCB outgoings UPS output. SITC of wall mounting type double door, dust & vermin proof 6 way 3 phase, MCB DB no 3 comprising one 3 phase 25A 4P 30 ma RCBO as in comer and 6-20 A SP MCB (18 nos) outgoings.(ldb) SITC of wiring using 4 run10 sq.mm & on run 6 sqmm PVC insulated, 1100 V grade, FRLS stranded, cu wire and 25mm dia flexible PVC conduit SITC of wiring using 4 run 6 sq.mm & one run 4sq.mm PVC insulated, 1100 V grade, FRLS stranded, cu wire and 25mm dia PVC conduit m 30 m 50 c SITC of wiring using 2 run 6 sq.mm & one run 4 sq.mm PVC insulated, 1100 V grade, FRLS stranded, cu wire and 25mm dia PVC conduit/flexible conduit m 150 d SITC of wiring using 3 run 4 sq. mm PVC insulated, 1100 V grade, stranded FRLS cu wire and 25 mm dia PVC conduit m 200 e SITC of wiring using 3 run 2.5 sq. mm PVC insulated, 1100 V grade, stranded FRLS m 800 cu wire and 25 mm dia PVC conduit ( circuit wiring UPS stations, light, fan,plug sockets etc) Rate is inclusive of charges chipping the wall/floor and making to original m.

Page 2 of 6 f SITC of one 25/20A motor starter with 20A socket and 20/25A 3 pin top single phase airconditioners. (socket shall be near indoor unit) no 7 g SITC of one 32A, 100mA sensitivity TP ELCB in metalic enclosure single phase AC input /sign board etc no 2 h SITC of one 25A, 100mA sensitivity DP ELCB in metalic enclosure single phase AC input /sign board etc no 8 I SITC of 63A, 100mA sensitivity 4P, RCBO with metalic enclosure. no 2 K SITC of 40A, 100mA sensitivity 4P, ELCB with metalic enclosure. no 2 L SITC of 40A4P isolator with metalic enclosure no 2 M SITC of 32A MCB 4P isolator with metalic enclosure no 2 6 Supply, laying, dressing,connecting and commissioning of 1100V grade PVC insulated armoured power cable (XLPE) with aluminium conductor concealed on wall/ceiling/trench with clamps including charges making trench(if any) by supplying necessary fixing materials. A 3.5 x 95 sq.mm m 10 b 3.5 x 70 sq.mm m 30 c 3.5 x 35 sq.mm m 75 d 4X25 sq.mm m 75 e 4X16 sq.mm m 100 f 4X 10 sq. mm m 150 7 SITC of end terminations of the following XLPE cables using flange type cable glands and heavy duty tinned aluminium type crimping cable sockets with gland earthing A 3.5x95 sq.mm no 2 b 3.5 x70 sq mm no 2 c 4X35 sq.mm no 2 d 4X25 sq.mm no 4 e 4X16 sq.mm no 4 f 4X 10 sq. mm no 8 8 SITC of 2x4 sq.mm armoured 1100V grade copper cable UPS earthing including end terminations m 150 9 SITC of bare earthing copper 0

Page 3 of 6 A 10 SWG m 400 b 8 SWG. m 150 C 4 SWG m 150 d c. 25mm 3 mm flat m 70 10 SITC of earthing station using 600 x 600 x 3mm copper plate buried in ground, 20 mm dia no 1 3 m long perated GI pipe with funnel and constructing inspection chamber by masonry work with concrete inspection cover conming to IS 3043 including civil work complete. 11a Point wiring light, fan etc;(from switch-board to fittings only): 0 SITC of all materials and wiring through wall, floor, ceiling concealed using color coded 1.5 sq.mm PVC insulated, 1100V grade, FRLS stranded copper wire point and same size no wire with green color as continuous earth points with independent earth wire each circuit through ISI grade 25mm PVC conduit including all accessories as per IS 9537 part I, factory made MS boxes, modular type 5A switches& switchboards and ceiling rose/connectors etc., of approved make controlling one light/fan/exhaust fan/calling bell etc., Number of wire to be used in the conduit should be limited to the IS standards. Rate is inclusive of cost of chipping floor/wall using machine and re-plastering to original m..all switches/sockets/switch boards shall be of modular type. Wherever wires are drawn on walls, it shall be concealed by chipping the plaster using proper machines. Where conduits are drawn above false ceiling, it shall be firmly clamped on the concrete ceiling/wall using clamps at regular interval (maximum one meter) or laid through rack/tray as per site condition. Rate shall be all inclusive. 50 b Same as above but controlling two lights by one switch. no 20 c Same as above but controlling three lights by one switch no 1 d Same as above but controlling four lights by one switch. no 5 e 12a SITC of wiring 6 nos LED down lighters in parallel connected to UPS supply with single control using 5A modular switch and plate with identification Same as above (item no. 11a ) but ceiling fans including supply & installing stepped type 250 W electronic fan regulator of approved make no 4 no 6 b Same as above but 6A 3 pin plug points combined (in switchboard) no 10 13 SITC of 6A modular switch &3 pin sockets in separate location wall fan etc( switch shall no 20 be installed at reachable height) including charges chipping the wall/floor and making to original m. 14 SITC of 2 plate 15/5A modular switch & sockets no 8 15 a UPS Power stations : SITC of 4 nos. 5A, 3 pin sockets controlled by one 15A master no. 30 switch (modular) in metal box. Number of wires in one conduit shall be limited as per standards. Master switch shall be in separate box at easily accessible position to operate by sitting on the chair.

Page 4 of 6 b Same as above but six socket with two master switches no 6 16 Supply,assembling, installation connection and commissioning of following light fittings including cost of fixing materials: 0 A 2' x 2', 31 Watt, square, recessed mounted LED luminaire, glare free light fittings with luminaire efficiency minimum of 100lm/watt with integral driver, flat diffuser and other controls (and mounting frame if required) complete (as per approved list - Philips RC380BLED 36S-6500 G3PSU OD or equivalent OSRAM) 40 b 4', 18 W LED tube light fittings integral driver and other controls..(as per approved list Philips BN 021) no 15 c 16 W LED down light fittings with driver and accessories complete (as per approved list- DN194B LED 16S-6500 PSU WH S1) no 38 d 10 W LED wall mounting/bulk head light fittings with driver and accessories complete - Philips WP202 no 4 e 9 W LED bulb (Philips) with angle holder no 4 17a Supply assembling, installation and commissioning of 48" high breeze ceiling fans with no 6 white color with all accessories including down rods ( and angle fastener if required as per site condition) b SITC of 300 mm heavy duty exhaust fan no 1 c SITC of 300 mm light duty exhaust fan no 2 d SITC of swivelling type 1200 sweep wall fans ivory color no 15 18 Supply and laying of ISI marked 25mm dia PVC conduit with accessories along floor/wall/partitions with termination box and GI lead wire as per site condition. m 100 19 SITC of flexible 3 core chord wire with copper conductor (2.5 sq. mm) with 15/5 A 3 pin top no 2 20 SITC of RJ11 telephone jack in modular box with wiring using 0.5sq. Mm 2 pair telephone cable with 20 mm dia PVC conduits converging to EPABX no 25 21 SITC of 20 pair KRONE connector no 1 22 Supply, laying & termination and commissioning of 0.5 sq.mm., 10 pair telephone cable with all accessories m 150 23 SITC of ceiling mounted speakers (Ahuja/Philips make) including supply, laying & no 14 connecting using 2Cx 1sq.mm.PVC insulated copper wire with 20 mm dia PVC conduit. All wires to converge to a suitable point at a convenient place keeping the PA system

Page 5 of 6 II Items related to obtaining separate KSEB connection to the site (under LT category) Note: Bee quoting, contractor should visit the site to understand the cable rout and provisions in the landlord's existing Main LT panel of Transmer LT side and other site conditions. 0 24 SITC of CT operated Kwh meter (1 no), and 4 nos 150/5, class 0.5 Cts no 1 conming to KSEB standards in the meter cubicle of Landlord's main LT panel by making necessary minor alterations as per site requirement. Contractor shall arrange/obtain necessary testing & certification from KSEB. Quoted rate is inclusive of transport & all incidental charges. Fee paid to KSEB/ Govt agencies will be reimbursed by the Bank separately on submission of the receipt from them) 25 SITC of metering cubicle consisting of one 200A 35KA MCCB with front no 1 operating mechanism so as to accommodate the above Kwh meter & CTs. (this item is provisional. To be supplied only if the LT Main panel have no space accommodating the Kwh meter with CT & after obtaining permission from the Bank) 26 Supply, laying, dressing,connecting and commissioning of 1100V grade, 3.5 x 150 sq mm m 125 PVC insulated armoured power cable (XLPE) with aluminium conductor through duct/ on wall/ceiling/trench with clamps /supports as per standards by supplying necessary fixing materials complete from Landlord's LT Main panel near their transmer to the electrical room of our site. 27 SITC of end terminations of the above XLPE cable using flange type cable glands and heavy duty tinned aluminium type crimping cable sockets with gland earthing no 2 28 Prepare & submit required drawing / as built drawing (of the electrical work carried out at lumps the site ) as per KSEB standards and application power allocation to KSEB, obtain um power allocation from KSEB in time, collect necessary drawings & consent from landlord (through AGM -Commercial branch) and obtain KSEB Sanction the connected load after completing the work. The drawings shall fulfill the requirement of the power supplying Agency of the site ( ie; KSEB) and the same shall be warded to the AGM Comm.Br. Ernakulam). Contractor should carry out necessary liaisoning and coordination with the landlord of the building obtaining necessary drawing/consent obtaining KSEB power connection to the site through AGM Comm.Br. Ernakulam. No separate charges will be paid this purpose. Quoted amount is inclusive of this also. (Note : Fee paid to KSEB/Govt agencies will be reimbursed by the Bank separately on submission of the receipt from the respective Govt. Agency) 29a Supply & providing electrical grade rubber floor mats sq. ft 60 1 b Supply & providing caution boards no 4 30 Prepare required drawing / as built drawing (of the electrical work carried out at the site ) lumpsum & also obtain its approval and sanction/license from the Kerala State Electrical Inspectorate and all other Govt. agencies including diesel generator(if any). The drawings shall fulfill the requirement of the power supplying Agency of the site ( ie; KSEB) and the same shall be warded to the AGM Comm.Br. Ernakulam). Contractor should carry out necessary liaisoning and coordination with the landlord of the building obtaining necessary drawing/consent obtaining KSEB power connection to the site. One copy of the above drawing shall be laminated and displayed in the electrical room. No separate charges will be paid this purpose. Quoted amount is inclusive of this also. (Note : Fee paid to Govt agencies will be reimbursed by the Bank separately on submission of the receipt from the respective Govt. Agency) 1

Page 6 of 6 NOTE: i. After completing the installation & commissioning work, the contractor shall prepare check-list (in the prescribed mat) of various parameters, carry-out electrical safety audit of the complete electrical installations and submit electrical safety audit report in the Bank's standard mat and a certificate stating that the work is carried out by conming to all safety standards and tender specifications. TOTAL : GST : i. CGST @... ii. SGST @... Grand Total In Words :