User Manual & Installation Instructions

Similar documents
CS+ Series. Pure Sine Wave Inverter/Charger User s Manual. Version 1.0 DIF

APS & APS

AP Series Pure Sine Wave Inverter/Charger User s Manual. Version 1.0

Global LF Series Pure Sine Wave Inverter Charger User s Manual PICOGLF12W12V120AL & PICOGLF25W12V120AL

R series solar charger inverter 1000W to 6000W

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

Global LF Series Pure Sine Wave Inverter/AC Charger User s Manual. Version 7.0

PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS

SP Series 600W&1,000W Pure Sine Wave Inverter/Charger User s Manual. For Models SP SP SP SP

USER MANUAL. GS Series Hybrid Inverter

Pure Sine Wave Inverter Charger

General Precautions. Personnel Precautions

AP/APP/APS/APV Series

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Global LF Series Pure Sine Wave Inverter/ Charger User s Manual

USER MANUAL. PW Series Inverter / Charger

MASTERsine Inverter PXA Series Installation Guide

AC CONVERTER / BATTERY CHARGER

Global LF Series Pure Sine Wave Inverter Charger User s Manual. Version 2.0 PICOGLF10KW48V240VS

USER S MANUAL SOLAR POWER INVERTER KW-6KW

MINI/ PSW7 Series. Pure Sine Wave Inverter/Charger User s Manual. Version 1.0

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Global LF Series Pure Sine Wave Inverter/ Chargers 5-12KW User s Manual. Version 4.0 (Code: / Updated on NOV 14 th 2013)

MINI/ PSW7 Series. Pure Sine Wave Inverter/Charger User s Manual. Version 1.0. Your Best Partner for Power

PureSine 150/300 Pure Sine Wave Inverter User s Manual

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Global LF Series Pure Sine Wave Inverter Charger User s Manual

TXF Series. Pure Sine Wave Inverter/AC Charger User s Manual. Version 1.0. TorTech. Designed to ISO9001 manufacturing standard

Pure Sine Wave Inverter/Charger

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

Pure Sine Wave DC TO AC Power Inverter. User s Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

SA-1000K & SA-3000K Series Pure Sine Wave Inverter User s Manual

Solar Charge Controller

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

SCC-MPPT Solar Charge Controller

CX-SERIES ADVANCED BATTERY CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER

Alphapower HTU UPS. Some key features include:

Spartan Power Pure Sine Wave Inverter/Charger User Manual. Version 1.0

S150,S300 Series Pure Sine Wave Inverter User s Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Global LF Series Pure Sine Wave Inverter Charger User s Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

DP Series Pure Sine Wave Inverter/Charger User s Manual

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

S600,S600R Series Pure Sine Wave Inverter User s Manual

Table of Contents 文管中心 發行章

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Solar Hybrid Inverter SP Efecto Series

Solar Hybrid Inverter SP Brilliant Series

S600,S600R Series Pure Sine Wave Inverter User s Manual

IPS3000P 3KVA INVERTER / CHARGER. Version 1.00 (English) BEFORE GETTING STARTED

UL458 Listed 1.5KW 2KW 3KW Pure Sine Wave Inverter/Charger User s Manual

Global LF Series Pure Sine Wave Inverter/ Charger User s Manual PICOGLF6W12V120V

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

DC TO AC POWER INVERTER

User Manual. Solar Charge Controller 3KW

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Solar Hybrid Inverter SP Efecto Series

Cruising Charger Series OWNER S MANUAL

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

1KW to 6KW Pure Sine Wave Inverter/Charger User s Manual

Duo Battery Charge Controller

400 Watt Backup Power System Owner s Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Solar Inverter Manual

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Compact Sine Inverter

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

IPS5000 5KVA INVERTER / CHARGER. Version 1.00 (English) BEFORE GETTING STARTED

User Manual WT Combi-S Pure Sinus Wave Inverter

User Manual Solar Charge Controller 3KW

IC Series THIC THIC THIC PROFESSIONAL GRADE POWER INVERTER. Low Frequency Inverter Charger

Pure Sine Wave Inverter User Manual

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

INTELLIGENT BATTERY CHARGER/MAINTAINER

LESTRONIC II BATTERY CHARGER MODEL 07210

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

AUTO CHARGE D PUMP PLUS

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

GSL Electronics Modified Sine Wave Power Inverters

Intelligent Charging System Series

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

BATTERY CHARGER CHR-1445

The Traveler Series: Wanderer

Transcription:

12KW Inverter Charger Residential & Commercial User Manual & Installation Instructions Model SEI 12 Off Grid + On Grid + AC Charger + MPPT + AGS +ATS + UPS

1-1. General Safety Precautions 1. Before installing and using the Inverter/Charger, read all instructions and cautionary markings on the Inverter /Charger and all appropriate sections of this guide. 2. This unit is designed for indoor use only. Do not expose the Inverter/Charger to rain, snow, or spray. 3. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the Inverter/Charger in a zero-clearance compartment. Overheating may result. 4. Use only attachments recommended or sold by the manufacturer. Doing otherwise may result in a risk of fire, electric shock, or injury to persons. 5. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not undersized. Do not operate the Inverter/Charger with damaged or substandard wiring. 6. Do not operate the Inverter/Charger if it has received a sharp blow, been dropped, or otherwise damaged in any way. 7. Do not disassemble the Inverter/Charger. It contains no user-serviceable parts. Attempting to service the Inverter/Charger yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is disconnected. 8. The Inverter contains more than one live circuit (batteries and AC line). Power may be present at more than one source. To reduce the risk of electrical shock, disconnect both AC and DC power from the Inverter/Charger before attempting any maintenance or cleaning or working on any circuits connected to the Inverter/Charger. Turning off controls will not reduce this risk. 9. Use insulated tools to reduce the chance of short-circuits when installing or working with the inverter, the batteries, or PV array. CAUTION: Equipment damage The output side of the inverter s AC wiring should at no time be connected to public power or a generator. This condition is far worse than a short circuit. If the unit survives this condition, it will shut down until corrections are made. Installation should ensure that the inverter s AC output is, at no time, connected to its AC input. Warning: Limitations On Use SPECIFICALLY, PLEASE NOTE THAT THE INVERTER/CHARGER SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. 1-2. Precautions When Working with Batteries 1. Make sure the area around the battery is well ventilated. 2. Never smoke or allow a spark or flame near the batteries. 3. Use caution to reduce the risk or dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion. 4. Remove all metal items, like rings, bracelets, and watches when working with lead-acid batteries. Lead-acid batteries produce a short circuit current high enough to weld metal to skin, causing a severe burn. 5. Have someone within range of your voice or close enough to come to your aid when you work near a lead-acid battery. 6. Have plenty of fresh water and soap near by in case battery acid contacts skin, clothing, or eyes. 7. Wear complete eye protection and clothing protection. Avoid touching your eyes while working near batteries.

8. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least twenty minutes and seek medical attention immediately. 9. If you need to remove a battery, always remove the grounded terminal from the battery first. Make sure all accessories are off so you don t cause a spark. 10. Always use identical types of batteries. 11. Never install old or untested batteries. Check each battery s date code or label to ensure age and type. 12. Batteries are temperature sensitive. For optimum performance, it should be installed in a stable temperature environment. 13. Always recycle old batteries. Contact your local recycling center for proper disposal information. 2. Introduction 2-1. General Information The Pure Sine Wave Inverter is a combination of an inverter, battery charger, and auto-transfer switch in one complete system with high conversion efficiency. It is one of the most advanced inverter/chargers on the market today. It features MPPT solar charge controller, power factor correction, automatic generator start, sophisticated multi-stage AC charger and a pure sine wave output. Grid priority/ups: When grid AC power cuts off or (falls out of acceptable range) the transfer relay is deenergized and the load is automatically transferred to the Inverter output. Once the qualified AC grid is restored, the relay is energized and the load is automatically reconnected to AC grid. The surge capacity is 300% of continuous output for up to 20 seconds to reliably support large loads with a high surge on startup such as pumps, air conditioners and industrial equipment. Battery Priority: The inverter can be easily customized to Battery priority via a DIP switch, this helps to extract maximum power from the battery. Thus, the Pure Sine Wave Inverter is suitable for Off grid, RV, Marine and Emergency appliances using grid/generator as a backup power supply. To get the most out of the power inverter, it must be installed, used and maintained properly. Please read the instructions in this manual before installing and operating. 2-2. Application Power tools circular saws, drills, grinders, sanders, buffers, air compressors ect. Office equipment computers, printers, monitors, facsimile machines, scanners ect. Household items vacuum cleaners, fans, lighting, air conditioners, heating ect. Kitchen appliances coffee makers, blenders, cook top, toasters, refrigerator ect. Industrial equipment metal halide lamp, high pressure sodium lamp ect. Home entertainment electronics television, stereos, gaming consoles ect.

2.3 Features Smart Remote Control (RMT) Battery Temperature Sensor (BTS) Automatic Generator Starting (AGS) High Speed Automatic Transfer Switch (ATS) Uninterrupted Power Supply (UPS) High/low voltage, over temp, over load, protection High surge ability up to 300% Designed for off grid, residential and commercial applications Durable industrial design Powerful AC charge rate up to 120A, selectable from 10%-100% Built in high efficiency 2x 40A MPPT solar charge controllers 8 preset battery type selector 4-step intelligent AC battery charging,(pfc Power Factor Correction) for charger Less than 8ms transfer time between grid/generator mode & off grid mode, ensuring power continuity 15s delay before transfer when AC resumes, protection for load when used with generator 2.3.1 The Mechanical Drawing of the Inverter

2.4 Electrical Performance 2.4.1 Inverter Topology The inverter/charger is built according to the following topology. Inverter: Full Bridge Topology. AC Charger: Isolate Boost Topology Because of high efficiency Mosfets and 16bit, 4.9MHz microprocessor and heavy transformers, it outputs PURE SINE WAVE AC with an average THD of 10% (Min5%, Max 15%) depending on load connected and battery voltage. Overload Capacity The inverters have different overload capacities, making it ideal to handle demanding loads. 1 For 110%<Load<125%(±10%), no audible alarm in 14 minutes, beeps 0.5s every 1s in the 15th minute, and Fault(Turn off) after the 15th minute. 2 For 125%<Load<150%(±10%), beeps 0.5s every 1s and Fault(Turn off) after the 1 minute. 3 For 300%<Load>150%(±10%), beeps 0.5s every 1s and Fault(Turn off) after 20s. 2.4.2 AC Charger The inverter is equipped with an active PFC (Power Factor Correction) multistage battery charger. The PFC feature is used to control the amount of power used to charge the batteries in order to obtain a power factor as close as possible to 1. Unlike other inverters whose max charging current decreases according to the input AC voltage, This inverter charger is able to output max current as long as input AC voltage is in the range of 184-253VAC and AC frequency is in the range of 48-54Hz Choosing 0 in the battery type selector will disable charging function. The 3 AC charging stages: Bulk Charging: This is the initial stage of charging. While Bulk Charging, the charger supplies the battery with controlled constant current. The charger will remain in Bulk charge until the Absorption charge voltage (determined by the Battery Type selection) is achieved. Software timer will measure the time from A/C start until the battery charger reaches 0.3V below the boost voltage, then take this time ast0 and T0 2 = T1. Absorb Charging: This is the second charging stage and begins after the absorb voltage has been reached. Absorb Charging provides the batteries with a constant voltage and reduces the DC charging current in order to maintain the absorb voltage setting. In this period, the inverter will start a T1 timer; the charger will keep the boost voltage in Boost CV mode until the T1 timer has run out. Then drop the voltage down to the float voltage. The timer has a minimum time of 1 hour and a maximum time of 12 hours. Float Charging: The third charging stage occurs at the end of the absorb Charging time. While Float charging, the charge voltage is reduced to the float charge voltage (determined by the Battery Type selection*). In this stage, the batteries are kept fully charged and ready if needed by the inverter.

If the A/C is reconnected or the battery voltage drops below 48Vdc the charger will reset the cycle above. If the charge maintains the float state for 10 days, the charger will deliberately reset the cycle to protect the battery.

Table 2.5.1 Battery Charging Processes Table 2.5.2 Battery Type Selector Switch Setting Description Fast Mode / VDC Float Mode / VDC 0 Charger Off 1 Gel USA 14.0 13.7 2 AGM 1 14.1 13.4 3 LiFePO4 14.6 13.7 4 Sealed Lead Acid 14.4 13.6 5 Gel EURO 14.4 13.8 6 Open Lead Acid 14.8 13.3 7 Calcium 15.1 13.6 For 12Vdc Batteries (4 for 48Vdc Model) Table 2.5.3 AC Charging Current Model SEI 12 Battery Voltage Max AC Charge Current 12000W 48Vdc 120±5A The charging capacity will go to peak in around 3 seconds. This may cause a generator to drop frequency, making inverter transfer to battery mode. It is suggested to gradually put charging load on the generator by switching the charging switch from min to max, together with the 15s switch delay, the inverter gives the generator enough time to spin up. This will depend on the size of the generator and rate of charge.

2.4.3 Transfer While in the Standby Mode, the AC input is continually monitored. Whenever AC power falls below the VAC Trip voltage (164 VAC, default setting for 230VAC or 240VAC), the inverter automatically transfers back to the inverter Mode with minimum interruption to your appliances - as long as the inverter is turned on. The transfer from Standby mode to Inverter mode occurs in less than 8 milliseconds. And it is the same time from Inverter mode to Standby mode.

There is a 15-second delay from the time the inverter senses that continuously qualified AC is present at the input terminals to when the transfer is made. This delay is built in to provide time for a generator to spin-up to a stable voltage and avoid relay chattering. The inverter will not transfer to generator until it has locked onto the generator s output. This delay is also designed to avoid frequent switching when grid input is unstable. 2.4.4 Auto frequency adjust The inverter has an Auto Frequency adjust function. The factory default configuration for 220/230/240VAC inverter is 50Hz, while the output frequency can be easily changed once a qualified frequency is applied to the inverter. If you want to get 60Hz from a 50Hz inverter, just input 60Hz power, and the inverter will automatically adjust the output frequency to 60Hz and vice versa. 2.4.5 Charge Controllers Parameter of the 2x Built in MPPT Charge Controllers Rated Voltage 48Vdc Rated charge current 2X 40Amp 12Vdc Load current 10Amp Input voltage range 55-105Vdc Max. PV open circuit array voltage 105Vdc 2.0 * I(Rated)>5s Overload protection (DC load) 1.5 * I(Rated) >20s 1.25 * I(Rated) temperature controlled Typical idle consumption At idle < 10mA Bulk charge 57.2Vdc (default) Floating charge 54.4Vdc (default) Equalization charge 56.0Vdc (default) Over charge disconnect 64.0Vdc Over charge recovery 56.0Vdc

Over discharge disconnect 43.5Vdc (default) Over discharge reconnect 49.5Vdc Temperature compensation -26.4mV Lead acid battery settings Adjustable NiCad battery settings Adjustable Low voltage reconnect 48.0-56.0Vdc Low voltage disconnect Ambient temperature 42.0-50.0Vdc 0-40 (full load) 40 60 (de-rating) Altitude Operating 5000 m, Non-Operating 16000 m Protection class IP21 Battery temperature sensor Terminal size (fine/single wire) BTS - optional remote battery temperature sensor for increased charging precision #8 AWG

Maximum Power Point Tracking (MPPT) Function Maximum Power Point Tracking, frequently referred to as MPPT, is an electronic system that operates the Photovoltaic (PV) modules in a manner that allows the modules to produce all the power they are capable of. The PV-seeker Charge controller is a microprocessor-based system designed to implement the MPPT. And it can increase charge current up to 30% or more compared to traditional charge controllers. (see figure 1). Figure 1 Current, Power vs. Voltage Characteristics. For 48VDC inverter, the qualified DC input volt range is 55v-105VDC. If the voltage falls out of this range, the charger will not work properly. Special attention should be paid to this when configuring the solar array. 2.4.6 Compatible Battery Type Agm, Gel, NiCad, Calcium, Sealed Lead Acid, Open Lead Acid. See MPPT charge controller user manual for more information.

2.4.7 Protections The inverter is equipped with extensive protections against various harsh situations/faults. These protections include: * AC Input over voltage protection/ac Input low voltage protection * Low battery alarm/high battery alarm * Over temperature protection/over load protection * Short Circuit protection (1s after fault) * Back feeding protection When Over temperature /over load occur, after the fault is cleared, the master switch has to be reset to restart the inverter. The Low battery voltage trip point can be customized from defaulted value 46VDC to 48VDC thru the SW1 on DIP switch. The inverter will go to over temp protection when heat sink temp. 105ºC, and go to Fault (shutdown Output) after 30 seconds. The switch has to be reset to activate the inverter. The inverter has back feeding protection which avoids presenting an AC voltage on the AC input terminal in inverter mode. 2.4.8 LED Indicator & LCD Table 2.5.5 LED Indicators LINE MODE YELLOW LED lit in Line Mode INVERTER MODE GREEN LED lit in Inverter Mode FAST CHARGE YELLOW LED lit in Fast Charging Mode FLOAT CHARGE GREEN LED lit in Float Charging Mode

OVER TEMP RED LED lit in Over Temperature OVER LOAD RED LED lit in Over Load 2X MPPT 2X GREEN LED lit MPPT Charge Controllers On

Table 2.5.6 LCD Indicator AC Display AC Input/AC Output/AC Frequency/Load DC Display Battery Voltage/Battery State of Charge Warnings Alarm/Fault Work Modes Online Mode/Inverter Mode LCD Automatic Sleep Mode LCD on Button 2.4.9 Warning Alarm Table 2.5.7 Warning Alarm Spec Battery Voltage Low Inverter green LED lit, and the buzzer beeps 0.5s every 5s. Battery Voltage High Inverter green LED lit, and the buzzer beeps 0.5s every 1s and Fault after 60s. (1)110%<load<125%(±10%), No Warning alarm in 14 minutes, Invert Mode Over-Load Beeps 0.5s every 1s in 15 th minute and Fault after 15 minutes; (2)125% <load<150%(±10%), Beeps 0.5s every 1s and Fault after 60s; (3)Load>150%(±10%), Beeps 0.5s every 1s and Fault after 20s; Over Temperature Heat sink temp. 105ºC, Over temp red LED Lighting, beeps 0.5s every 1s;

2.4.10 DIP Switches On the DC end of inverter, there are 5 DIP switches which enable users to customize the performance of the inverter. Table 2.5.8 Dip Switch Function Setting Switch no# Switch Function Position: 0 Position: 1 SW1 Low Battery Trip Volt 46VDC 48VDC SW2 AC Input Range 184-253VAC 140-270VAC SW3 AC Output Voltage 230VAC 240VAC SW4 AC Output Frequency 50Hz 60Hz SW5 Grid/Battery Priority Grid Priority Battery Priority SW1: Low Battery Trip Point: The Low Battery Trip point is set at 46Vdc or can be customized to 48Vdc using SW1, this is to prevent batteries from over-discharging. SW2: AC Input Range: There are different acceptable AC input ranges for different kinds of loads. For some relatively sensitive electronic devices, a narrow input range of 184-253VAC is required to protect the devices. While for some resistive loads which work in a wide voltage range, the input AC range can be customized to 140-270VAC, this helps to power loads with the most AC input power without frequent switching to the battery bank. SW3: AC Output Voltage: The inverter can output either 230VAC or 240VAC outputting 230VAC will increase the output efficiency with a maximum constant output of 11.5KW suitable for off grid and residential applications. Outputting 240VAC is suitable for large loads and commercial applications with a maximum constant output of 12KW. SW4: AC Output Frequency: The inverter can be easily customized to output either 50Hz or 60Hz depending on your location or appliances using SW4. SW5: Grid Priority/Battery Priority: When using grid priority the inverter will transfer to battery when the AC grid cuts out to power the loads until the AC grid returns then transfer back to AC grid to power the loads.

When using battery priority the inverter will output power from the battery until the battery is depleted then it will transfer to grid/generator until the battery is charged then transfer back to the battery. When using the grid or a generator you can use the AC charger and PV to charge the battery. For off grid with no generator you can charge the battery solely from PV input.

2.4.11 Fan operation For 12KW, there is one multiple controlled DC fan and one AC fan. The AC fan will work once there is AC output from the inverter. And DC fan work according to following logic. Table 2.5.9 Fan Operation Logic Condition Enter Condition Leave condition Speed HEAT SINK TEMPERATURE T < 85 T 85 50% T 85 T < 80 100% CHARGER CURRENT I 50%Max I > 50%Max 50% I > 50%Max I 40%Max 100% LOAD Percentage Load < 50% Load 50% 50% (INV MODE) Load 50% Load 40% 100% Allow at least 30CM of clearance around the inverter for air flow. Make sure that the air can circulate freely around the unit. Fan noise level is a maximum 60db at a distance of 1m 2.4.12 Other features Battery voltage recovery After low battery voltage shut down 46VDC or 48VDC, the inverter is able to return battery mode after the battery voltage recovers to 56Vdc (with power switch still in the On position). This function helps to save the user extra labor to reactivate the inverter when the low battery voltage recovers to an acceptable level. Also the low voltage trip point will vary depending on load 44VDC or 46VDC with no load and 46VDC or 48VDC with load. Auto Gen Start The inverter can be customized to start up a generator when battery voltage goes low. When the inverter goes to low battery alarm, it can send a signal to start a generator, and turn the generator off after battery charging is finished. The auto gen start feature will only work with generators designed to work with this feature. There is an open/closed relay that will complete the circuit from a generator for start and stop. The DC input voltage can vary, but the Max current the relay can carry is 16Amp.

2.4.13 Specification Electrical Specifications Model SEI 12 12KW Continuous Output Power 12KW Surge Rating(20s) 36KW Output Waveform Pure Sine wave/same as input Nominal Efficiency >88% Line Mode Efficiency >95% Power Factor 0.9-1.0 Inverter Output Nominal Output Voltage rms 230Vac/240Vac Output Voltage Regulation ±10% RMS Output Frequency 50Hz/60Hz ± 0.3Hz Short Circuit Protection Yes( 1sec after fault ) Typical transfer Time Less than 8ms THD < 10% Nominal Input Voltage 48Vdc Minimum Start Voltage 44Vdc Low Battery Alarm 46.5Vdc/48.5Vdc With load DC Input Low Battery Trip 46Vdc/48Vdc With load High Voltage Alarm 64Vdc Low Battery voltage recover 56Vdc Mechanical Specifications Mounting Aprox Dimensions(L*W*H) Aprox Inverter Weight Wall Mount 720*480*210mm 48KGS

3 Installation 3.1 Location Follow all the local regulations to install the inverter. Please install the equipment in a location that is Dry, Clean, Cool and that has good ventilation. Working temperature: 10>40+-5 Storage temperature: 40>70+-5 Relative Humidity: 0%>95% Cooling: Forced air 3.2 DC Wiring recommendation It is suggested the battery bank be kept as close as possible to the inverter. The following table is a suggested wiring option for 1 meter DC cable. Please find the following minimum wire size. In case of DC cable longer than 1m, please increase the cross section of cable to reduce the loss. Model Wire Gage SEI 12 Battery Voltage 12000W 48Vdc AWG 1/0

3.3 Warranty We offer a 1 year limited warranty. The following cases are not covered under warranty. 1 DC polarity reverse. The inverter is designed without DC polarity reverse protection. A polarity reverse may severely damage the inverter. 2 Wrong AC wiring 3 Operating in a wet environment. 4 Operating with an undersized generator or generator with unqualified wave form.

INSTALLATION INSTRUCTIONS Be sure to read the installation guide and user manual thoroughly. Installation must be carried out by a licenced electrician following all relevant AS/NZS standards and local regulations of your state/territory or country on installing this equipment. Failure to do so may result in electric shock, fire or death. Location Follow all the local regulations to install the inverter. Please install the equipment in a location that is Dry, Clean, Cool and that has good ventilation. Working temperature: 10>40+-5 Storage temperature: 40>70+-5 Relative Humidity: 0%>95% Cooling: Forced air Wiring recommendation It is suggested the battery bank be kept as close as possible to the inverter. The following table is the suggested wire gage for 1.5 meter of DC cable. Please use the following minimum wire size. If the DC cable is longer than 1.5m please increase the wire gage to reduce resistance and energy losses. Model SEI 12 Battery Voltage Wire Gage 12000W 48Vdc AWG 1/0 Battery cables must have crimped (or preferably, soldered and crimped) copper, steel and aluminium compression ring terminal lugs are acceptable. Cables must be colour coded with pressure crimped and sealed ring terminals. The larger the gage of cable and the shorter the length the better the performance.

$ WARNING: Battery Cable Connections CAUTION: Equipment Damage The inverter is not reverse polarity protected. Reversing the battery polarity on the DC input connections will cause permanent damage to the inverter which is not covered under warranty. Always check polarity before making connections to the inverter. All terminals must be clean and tight to reduce the resistance between wire and terminal to avoid overheating during periods of high current draw. Shock Hazard Ensure the inverter, solar array and AC power supply is turned off check all wiring and cable is in good condition and sized correctly before beginning installation. AC Wiring We recommend using 5AWG wire to connect to the AC terminal block

Inverter input & output Installation procedures 1.Check and make sure the unit is not damaged in any way before beginning installation. 2.Turn off all PV solar power and AC grid power then test to confirm isolation before beginning installation. 3.Attach the unit securely in place using adequate fixtures. 4.Check and make sure all AC and DC solar circuit breakers on the inverter are turned off. 5.Remove the protection cover from the terminal block. 6.Connect the AC grid/generator input and the AC load output wires in accordance with the instructions below the terminal blocks. 7.Connect the PV solar input wires in accordance with the instructions below the terminal blocks. 8.Restore the protection cover back over the terminal blocks. 9.Connect the negative and positive leads of the battery bank to the battery input of the inverter via a battery isolator/disconnect. 10.Turn on the battery isolator/disconnect then the inverter will power up then customise the setting to suite your applications in accordance with the user manual. 11.Turn on all AC input/output and PV solar input and commence operation and inspection.

Battery Information Battery Type There are two principal types of batteries: Starting type and Deep-Discharge type. Batteries can be either sealed or non-sealed(vented). A.Starting type: Automotive(Starting type) batteries are designed to provide high starting current for short periods of time and are not appropriate for solar systems. B.Deep-Discharge type: The battery types recommended for use with this inverter system are Flooded lead acid, Gel, Agm, Sealed lead acid, Ni-Iron, Calcium. * Sealed construction, safety and no leakage * Maintenance-free, convenient for installation * Broad operating temperature range * High capacity, high energy density * Long service life, Excellent recharge and discharge performance * Low self-discharge rate, more deep cycle times Battery Configurations The battery bank must be wired to match the inverter s DC input voltage specifications (48Vdc). In addition, the batteries can be wired to provide additional run time. Series Wiring batteries in series increases the total bank output voltage. This voltage MUST match the DC requirements of the inverter or inverter and/or battery damage may occur. Parallel Wiring the batteries in parallel increases the total run time the batteries can operate the AC loads. The more batteries connected in parallel the longer the loads can be powered from the inverter. Series-Parallel Series-parallel configurations increase both the battery voltage (to match the inverter s DC requirements) and run-time for operating the AC loads. This voltage must match the DC requirements of the inverter.

Wiring Batteries Important: Connecting the positive and negative wires to the inverter from different strings ensures a balanced charge/discharge through the batteries, resulting in longer run times and improved battery life. Batteries Maintenance To get the best performance from an inverter system, the batteries must be properly setup and maintained. Battery posts must be clean to reduce the resistance between the battery post and cable connection. A buildup of dirt or oxidation may eventually lead to the cable terminal overheating during periods of high current draw. Use a stiff wire brush and remove all dirt and corrosion from the battery terminals and cables. Use an alkaline solution of baking soda and water to clean the terminals and neutralize any battery acid on the terminals or cable lugs.