Housings and Miscellaneous Parts Standard and Special Valve Housings, Orifice Disks, Orifice Sizing harts, Pilot Pistons, dapters, djustment Kits and Seal Kits ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-1
Housings and Miscellaneous Parts Section contents Page Standard housings -**-...luminum (Light duty)... -3 -**-...luminum (NFP fatigue rated)... -4 -**-...Steel (NFP fatigue rated)... -5 -**-3/3S...luminum (Light duty)... -6 -**-3/3S...luminum (NFP fatigue rated)... -7 -**-3...Steel (NFP fatigue rated)... -8 -**-3S...Steel (NFP fatigue rated)... -9-16-3S...Steel (NFP fatigue rated) special housings for EPV16 only... -10 -**-4...luminum (Light duty)... -11 -**-4...luminum (NFP fatigue rated)... -1 -**-4...Steel (NFP fatigue rated)... -13 -**-5S...Steel and aluminum (NFP fatigue rated) (special housings for PFRD/S only)... -14 Port dimensions - all housings... -15 Special Housings - Load control valves Part numbers - V, PO, V housings... -15-10 size V, PO housings... -18-1 size V, PO housings... -1-10 size V housings... -5-1 size V housings... -7 Special Housings - olt on manifold for Eaton spool and disk motors Overview... -9 Dual V package with brake release shuttle for H & T series Eaton motors... -30 Dual PO package with brake release shuttle for H & T series Eaton motors... -31 ross over relief valve package for H & T series Eaton motors... -3 ross over relief valve package for 000 series Eaton motors... -33 Dual V package with brake release shuttle for 000 series Eaton motors... -34 Dual PO package with brake release shuttle for 000 series Eaton motors... -35 avity plugs Standard cavity plugs... -36 Special cavity plugs... -37 Orifice discs and orifice sizing chart Orifice discs... -38 Orifice sizing chart (Metric)... -39 Orifice sizing chart (US units)... -40 Miscellaneous parts Pilot pistons... -41 Sense check kits and panel mount adapters... -4 Miscellaneous parts / adjustment kits... -43 djustment kits... -43 Seal kits... -45 - ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**- luminum housings (Light duty) HOUSING PORTS 1 & PRT NUMER ODE 10 3/8 SPP 0-17546 ()3 SE 6 566151 ()6T 16 3/4 SPP 0-175463 ()6 SE 1 566149 ()1T 0 1 SPP 0-175464 ()8 SE 16 566409 ()16T E D Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. G 1 F I H DIMENSIONS D E F G H I MSS kg (lb) -10-50,8 19,0 50,8 31,7 15,9 19,0 7,1 3,1 1,7 0,1 (.00) (0.75) (.00) (1.5) (0.6) (0.75) (0.8) (0.1) (0.50) (0.35) -16-76, 8,5 76, 47,6 3,8 5,4 8,6 4,0 19,0 0,5 (3.0) (1.1) (3.00) (1.87) (0.94) (1.00) (0.34) (0.16) (0.75) (1.1) -0-88,9 34,3 88,9 68,5 34,3 36,8 8,6 4,0 1,6 0,8 (3.5) (1.35) (3.50) (.70) (1.35) (1.45) (0.34) (0.16) (0.85) (1.90) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-3
-**- luminum housings (NFP fatigue rated) HOUSING PORTS 1 & PRT NUMER ODE 8 1/4 SPP 0 16077 ()G 3/8 SPP 0 16078 ()3G SE 4 0 160730 ()4H SE 6 0 160731 ()6H SE 8 0 16073 ()8H 10 1/4 SPP 87670 ()G 3/8 SPP 876703 ()3G SE 6 876700 ()6H SE 8 876701 ()8H 1 1/ SPP 0 161118 ()4G 3/4 SPP 0 161117 ()6G SE 10 0 160640 ()10H SE 1 0 160644 ()1H HOUSING PORTS 1 & PRT NUMER ODE 1 U 1/ SPP 0 161116 ()4G 3/4 SPP 0 161115 ()6G SE 10 0 160641 ()10H SE 1 0 160645 ()1H 16 1/ SPP 876716 ()4G 3/4 SPP 876718 ()6G SE 10 876717 ()10H SE 1 566113 ()1H 0 3/4 SPP 87673 ()6G 1 SPP 876734 ()8G SE 1 876733 ()1H SE 16 876735 ()16H Notes SPP porting is designated by G in the model code SE porting is designated by either H or T in the model code. E D E D Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. G G I H 1 I 1 F ll except 1 (U) H 1 (U) F DIMENSIONS D E F G H I MSS kg (lb) -8-50,8 19,0 51,0 38,1 19,0 3,4 15,5 7,1 1,7 0, (.00) (0.75) (.00) (1.50) (0.75) (0.13) (0.61) (0.8) (0.50) (0.46) -10-63,5 5,4 63,5 50,8 5,4 9,5 0,8 7,1 19,0 0,4 (.50) (1.00) (.50) (.00) (1.00) (0.37) (0.81) (0.8) (0.75) (1.00) -1-(U) 88,9 44,5 88,9 50,8 5,4 1,7 8,7 63,5 63,5 0,8 (3.50) (1.75) (3.50) (.00) (1.00) (0.50) (1.13) (.50) (.50) (1.96) -16-88,9 34,9 88,9 63,5 31,7 10,3 8,4 8,7 5,4 1, (3.50) (1.37) (3.50) (.50) (1.5) (0.40) (1.11) (0.34) (1.00) (.75) -0-101,6 38,1 101,6 8,5 41,3 10,3 36,0 8,7 5,4 1,8 (4.00) (1.50) (4.00) (3.5) (1.6) (0.40) (1.41) (0.34) (1.00) (4.00) -4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**- Steel housings (NFP fatigue rated) HOUSING PORTS 1 & PRT NUMER ODE 8 1/4 SPP 0 160733 (S)G 3/8 SPP 0 160734 (S)3G SE 4 0 160736 (S)4T SE 6 0 160737 (S)6T SE 8 0 160738 (S)8T 10 1/4 SPP 0 17510 (S)G 3/8 SPP 0 175103 (S)3G SE 6 0 175100 (S)6T SE 8 0 175101 (S)8T 1 1/ SPP 0 1706 (S)4G 3/4 SPP 0 169665 (S)6G SE 10 0 169744 (S)10T SE 1 0 16978 (S)1T HOUSING PORTS 1 & PRT NUMER ODE 1 U 1/ SPP 0 1751 (S)4G 3/4 SPP 0 169 (S)6G SE 10 0 169817 (S)10T SE 1 0 169790 (S)1T 16 1/ SPP 0 175106 (S)4G 3/4 SPP 0 175107 (S)6G SE 10 0 175104 (S)10T SE 1 0 175105 (S)1T 0 3/4 SPP 0 175110 (S)6G 1 SPP 0 175111 (S)8G SE 1 0 175108 (S)1T SE 16 0 175109 (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. E D E D Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. F I G F G 1 1 I H H I Ø 1 (U) DIMENSIONS D E F G H I MSS kg (lb) -8-* 50,8 19,0 50,8 38,1 19,0 15,5 38,1 3,3 43,9 7,1 0,5 (.00) (0.75) (.00) (1.50) (0.75) (0.61) (1.50) (0.13) (1.73) (0.8) (1.19) -10-63,5 5,4 63,5 44,4, 19,0 50,8 9,5 44,4 7,1 0,3 (.50) (1.00) (.50) (1.75) (0.87) (0.75) (.00) (0.37) (1.75) (0.8) (0.83) -1-(U) 88,9 8,5 88,9 50,8 5,4 8,7 76, 1,7 63,5 10,3 1,9 (3.50) (1.1) (3.50) (.00) (1.00) (1.13) (3.00) (0.50) (.50) (0.40) (4.8) -16-88,9 38,1 76, 50,8 5,4 5,4 63,5 1,7 63,5 10,3, (3.50) (1.750) (3.00) (.00) (1.00) (1.00) (.50) (0.50) (.50) (0.40) (5.00) -0-101,6 41, 88,9 63,5 31,7 31,7 76, 1,7 76, 10,3 3,6 (4.00) (1.6) (3.50) (.50) (1.5) (1.5) (3.00) (0.50) (3.00) (0.40) (7.96) * 8 series housing utilize a slot instead of a mounting hole. ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-5
-**-3/3S luminum housings (Light duty) PORTS PRT HOUSING 1, & 3 NUMER ODE 10 3 3/8 SPP 0 173358 ()3 SE 6 56616 ()6T 10 3S 3/8 SPP 0 175470 ()3 SE 6 566413 ()6T 16 3 3/4 SPP 0 175465 ()6 SE 1 56615 ()1T 16 3S 3/4 SPP 0 175471 ()6 SE 1 566414 ()1T 0 3 1 SPP 0 175466 ()8 SE 1 566408 ()1T 0 3S 1 SPP 0 17547 ()8 SE 16 566415 ()16T Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. G I 3 F 1 E H D DIMENSIONS D E F G H I MSS -10-3 63,5 31,7 66,6 31,7 15,8 3,1 19,0 34,9 7,1 1,7 0,3 (.50) (1.5) (.6) (1.5) (0.6) (0.1) (0.75) (1.37) (0.8) (0.50) (0.64) -10-3S 63,5 34,9 69,8 38,1 19,1 3,1 1,7 31,7 7,1 1,7 0, (.50) (1.37) (.75) (1.50) (0.75) (0.1) (0.50) (1.5) (0.8) (0.50) (0.51) -16-3 101,6 50,8 107,9 50,8 5,4 4,0 5,4 53,9 8,6 5,4 1,0 (4.00) (.00) (4.5) (.00) (1.00) (0.16) (1.00) (.1) (0.33) (1.00) (.3) -16-3S 88,9 47,6 88,9 60,3 30,1 4,0 17,4 38,1 8,7 19,0 0,7 (3.50) (1.87) (3.50) (.37) (1.63) (0.16) (0.68) (1.50) (0.34) (0.75) (1.66) -0-3 114,3 57,1 139,7 63,5 31,7 4,0 31,7 7,1 10,4 5,4 1,7 (4.50) (.5) (5.50) (.50) (1.5) (0.16) (1.5) (.84) (0.41) (1.00) (3.9) -0-3S 101,6 57,1 107,9 69,8 34,9 4,0 0,6 50,8 8,7 19,0 1, kg (lb) -6 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**-3/3S luminum housings (NFP fatigue rated) PORTS PRT HOUSING 1, & 3 NUMER ODE 8 3 1/4 SPP 0 160739 ()G 3/8 SPP 0 160740 ()3G SE 4 0 160741 ()4H SE 6 0 16074 ()6H 10 3 1/4 SPP 876705 ()G 3/8 SPP 876714 ()3G SE 6 876704 ()6H SE 8 876711 ()8H 10 3S 1/4 SPP 876707 ()G 3/8 SPP*** 876710 ()3G SE 6 876706 ()6H SE 8** 87671 ()8H 1 3 3/8 SPP 0 161816 ()3G 1/ SPP 0 161817 ()4G SE 10 0 16064 ()10H SE 1 0 160646 ()1H 1 3S 1/ SPP* 0 17870 ()4G 3/4 SPP* 0 17871 ()6G SE 10** 0 17868 ()10H SE 1** 0 17869 ()1H PORTS PRT HOUSING 1, & 3 NUMER ODE 16 3 1/ SPP 87670 ()4G 3/4 SPP 8767 ()6G SE 10 87671 ()10H SE 1 87673 ()1H 16 3S 1/ SPP 0 160676 ()4G 3/4 SPP 87676 ()6G SE 10 87675 ()10H SE 1 87677 ()1H 0 3 1/ SPP 876737 ()4G 3/4 SPP*** 876738 ()6G SE 10 876757 ()10H SE 1 876739 ()1H 0 3S 3/4 SPP 876740 ()6G 1 SPP 87674 ()8G SE 1 876741 ()1H SE 16 876743 ()16H * Port 3 = 3/8 SPP ** Port 3 = SE 6 *** Port 3 = 1/4 SPP Notes SPP porting is designated by G in the model code SE porting is designated by either H or T in the model code. Note Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. E D G I 3 F 1 H DIMENSIONS D E F G H I MSS kg (lb) -8-3 63,5 31,8 66,6 38,1 19,0 3,4 15,5 9,8 7,1 13,0 0,4 (.50) (1.5) (.6) (1.50) (0.75) (0.13) (0.61) (1.17) (0.8) (0.51) (0.83) -10-3 76, 38,1 76, 50,8 5,4 9,5 0,8 36,6 7,1 19,0 0,7 (3.00) (1.50) (3.00) (.00) (1.00) (0.37) (0.81) (1.44) (0.8) (0.75) (1.65) -10-3S 76, 38,1 76, 50,8 5,4 9,5 16,8 33,5 7,1 19,0 0,7 (3.00) (1.50) (3.00) (.00) (1.00) (0.37) (0.66) (1.3) (0.8) (0.75) (1.65) -1-3 88,9 44,5 107,9 50,8 5,4 1,7 8,7 51,6 10,3 1,7 0,8 (3.50) (1.75) (4.5) (.00) (1.00) (0.50) (1.13) (.03) (0.41) (0.50) (1.80) -1-3S 88,9 44,5 101,6 50,8 5,4 1,7 3,0 4,1 10,3 1,7 0,8 (3.50) (1.75) (4.00) (.00) (1.00) (0.50) (0.91) (1.66) (0.41) (0.50) (1.80) -16-3 114,3 60,3 114,3 63,5 31,7 10,3 8,4 57,0 8,7 5,4,0 (4.50) (.37) (4.50) (.50) (1.5) (0.40) (1.1) (.4) (0.34) (1.00) (4.50) -16-3S 114,3 60,3 114,3 63,5 31,7 10,3 0,4 41,1 8,7 5,4,0 (4.50) (.37) (4.50) (.50) (1.5) (0.40) (0.80) (1.6) (0.34) (1.00) (4.40) -0-3 17,0 63,5 139,7 8,5 41, 10,3 36,0 76,5 8,7 5,4 3,5 (5.00) (.50) (5.50) (3.5) (1.6) (0.40) (1.4) (3.01) (0.34) (1.00) (7.71) -0-3S 17,0 63,5 17,0 8,5 41, 10,3 4,9 55,0 8,7 5,4 3,6 (5.00) (.50) (5.00) (3.5) (1.6) (0.40) (0.98) (.17) (0.34) (1.00) (8.00) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-7
-**-3 Steel housings (NFP fatigue rated) PORTS PRT HOUSING 1, & 3 NUMER ODE 8 3 1/4 SPP 0 160745 (S)G 3/8 SPP 0 160746 (S)3G SE 4 0 160743 (S)4T SE 6 0 160744 (S)6T 10 3 1/4 SPP 0 17517 (S)G 3/8 SPP 0 17518 (S)3G SE 6 0 17514 (S)6T SE 8 0 17515 (S)8T 1 3 1/ SPP 0 169815 (S)G 3/8 SPP 0 169814 (S)3G SE 10 0 161070 (S)10T SE 1 0 169816 (S)1T 16 3 1/ SPP 0 175131 (S)4G 3/4 SPP 0 17513 (S)6G SE 10 0 17519 (S)10T SE 1 0 175130 (S)1T 0 3 3/4 SPP 0 175135 (S)6G 1 SPP 0 175136 (S)8G SE 1 0 175133 (S)1T SE 16 0 175134 (S)16T K H 1 I 3 E D F G Ø Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Notes Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. DIMENSIONS D E F G H I K MSS kg (lb) -8-3* 63,5 31,8 66,0 38,1 19,0 15,5 53,0 3,3 56,6 7,1 9,8 0,9 (.50) (1.5) (.75) (1.50) (0.75) (0.61) (.1) (0.13) (.3) (0.8) (1.17) (.15) -10-3 76, 38,1 76, 44,4, 19,0 63,5 9,5 57,1 7,1 34,9 1,7 (3.00) (1.50) (3.00) (1.75) (0.87) (0.75) (.50) (0.37) (.5) (0.8) (1.37) (3.75) -1-3 88,9 44,4 101,6 50,8 5,4 8,7 88,9 1,7 63,5 10,3 51,5 3,0 (3.50) (1.75) (4.00) (.00) (1.00) (1.13) (3.50) (0.50) (.50) (0.40) (.03) (6.75) -16-3 101,6 50,8 107,9 50,9 5,4 5,4 88,9 1,7 76, 10,3 53,9 3,4 (4.00) (.00) (4.5) (.00) (1.00) (1.00) (3.50) (0.50) (3.00) (0.40) (.1) (7.70) -0-3 114,3 57,1 139,7 63,5 31,7 31,7 114,3 19,0 76, 11,9 7, 6,4 (4.50) (.5) (5.50) (.50) (1.5) (1.5) (4.50) (0.75) (3.00) (0.47) (.84) (14.30) * 8 Series housings utilize a slot instead of mounting holes. -8 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**-3S Steel housings (NFP fatigue rated) PRT HOUSING PORTS 1 & PORT 3 NUMER ODE 10 3S 3/8 SPP 1/4 SPP 0 163313 (S)3G 1/ SPP 1/4 SPP 0 16334 (S)4G SE 6 SE 6 0 171961 (S)6T SE 8 SE 6 0 1633 (S)8T SE 10 SE 6 0 16333 (S)10T 1 3S 1/ SPP 3/8 SPP 0 160994 (S)4G 3/4 SPP 3/8 SPP 0 160995 (S)6G SE 10 SE 6 0 160996 (S)10T SE 1 SE 6 0 160997 (S)1T 16 3S 1/ SPP 3/8 SPP 0 175118 (S)6G 3/4 SPP 3/8 SPP 0 175119 (S)6G SE 10 SE 6 0 175116 (S)10T SE 1 SE 6 0 175117 (S)1T 0 3S 3/4 SPP 3/8 SPP 0 1751 (S)6G 1 SPP 3/8 SPP 0 17513 (S)8G SE 1 SE 6 0 17510 (S)1T SE 16 SE 6 0 17511 (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. E D E D Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. K G 3 I F K 3 F G 1 LØ -10 & -1 H H 1 I -16 & -0 LØ DIMENSIONS D E F G H I K LØ MSS kg (lb) -10-3S 63,5 31,8 76, 41,3 0,7 36,6 53,8 11, 53,8 9,7 19,8 8,7 1,08 (.50) (1.5) (3.00) (1.63) (0.8) (1.44) (.1) (0.44) (.1) (0.38) (0.78) (0.34) (.40) -1-3S 88,9 44,5 101,6 50,8 5,4 41,9 76, 31,7 57,1 1,7 3,1 10,3,4 (3.50) (1.75) (4.00) (.00) (1.00) (1.65) (3.00) (1.5) (.5) (0.50) (0.91) (0.40) (5.40) -16-3S 88,9 41, 88,9 50,8 5,4 38,1 69,8 1,7 63,5 19,0 17,4 10,3,6 (3.50) (1.6) (3.50) (.00) (1.00) (1.50) (.75) (0.50) (.50) (0.75) (0.68) (0.40) (5.90) -0-3S 101,6 44,4 114,3 63,5 31,7 50,8 88,9 1,7 76, 5,4 0,6 10,3 4,6 (4.00) (1.75) (4.50) (.50) (1.5) (.00) (3.50) (0.50) (3.00) (1.00) (0.81) (0.40) (10.4) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-9
-16-3S Steel (NFP fatigue rated) Special housings for EPV16 only For use with EPV16- or only HOUSING NUMER LUMINUM STEEL ODE PORT SIZE EPV16- EPV16- EPV16- EPV16-4G 1/ SPP 0-185448 0-166607 0-180050 0-165500 6G 3/4 SPP 0-185449 0-16158 0-180051 0-164931 10H SE 10 0-185446 0-17038 1H SE 1 0-185447 0-166609 10T SE 10 0-180048 0-161983 1T SE 1 0-180049 0-16198 5 ETOP5 (NFP D05) interface (Requires steel housing) MODEL D E F G ØH MSS kg (lb) lum Steel Modified -16-3S 76, 30, 79, 100,8 38,1 1,7 1,6 8,7 60,4,0 6,0 body (3.00) (1.19) (3.1) (3.97) (1.50) (0.50) (0.85) (0.34) (.38) (4.50) (13.5) Modified housing for use with EPV16-. ØH ( places) Port G F ( places) E Modified housing for use with EPV16-. ØH ( places) Port D "" G F ( places) -10 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**-4 luminum housings (Light duty) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE 10 4 3/8 SPP 0-179705 ()3 SE 6 566161 ()6T 16 4 3/4 SPP 0-175468 ()6 SE 1 566411 ()1T 0 4 1 SPP 0-175469 ()8 SE 16 56641 ()16T HOUSING (FD*-**ONLY) 10 4 3/8 SPP 0-175467 ()3 SE 6 56634 ()6T 16 4 3/4 SPP 0-175468 ()6 SE 1 56600 ()1T Notes SPP porting is designated by in the model code SE porting is designated by T in the model code. Note Light duty aluminum housings are intended for applications up to 10 bar (3000 psi) with light to moderate duty cycles. E D E D H H G 3 4 K G 3 4 K I F 1 I F (FD*-**only) DIMENSIONS D E F G H I K MSS -10-4 63,5 31,7 8,5 31,7 15,8 3,1 34,9 19,0 7,1 9,5 50,8 0,3 (.50) (1.5) (3.5) (1.5) (0.6) (0.1) (1.37) (0.75) (0.8) (0.37) (.00) (0.7) -16-4 106,6 50,8 133,3 50,8 5,4 3,8 53,9 5,4 8,7, 8,5 1,4 (4.00) (.00) (5.5) (.00) (1.00) (0.15) (.1) (1.00) (0.34) (0.87) (3.5) (3.4) -0-4 114,3 57,1 117,8 63,5 31,7 4,0 7,1 31,7 10,4 5,4 113,5,6 (4.50) (.5) (7.00) (.50) (1.5) (0.16) (.84) (1.5) (0.41) (1.00) (4.47) (5.76) Note For -10-4 housings for V valves see page -5. kg (lb) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-11
-**-4 luminum housings (NFP fatigue rated) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE 8 4 1/4 SPP 0 160747 ()G 3/8 SPP 0 160748 ()3G SE 6 0 160749 ()6H SE 8 0 160750 ()8H 10 4 1/4 SPP 876709 ()G 3/8 SPP 876715 ()3G SE 6 876708 ()6H SE 8 876713 ()8H 16 4 1/ SPP 87678 ()4G 3/4 SPP 876730 ()6G SE 10 87679 ()10H SE 1 876731 ()1H 0 4 3/4 SPP 876744 ()6G 1 SPP 876746 ()8G SE 1 876745 ()1H SE 16 876747 ()16H G I 3 F 1 4 E D H K G I 4 3 F ( FD* **only) E D H K HOUSING (FD*-**ONLY) 10 4 1/4 SPP 0 185804 ()G 3/8 SPP 0 185805 ()3G SE 6 0 18580 ()6H SE 8 0 185803 ()8H Notes SPP porting is designated by G in the model code SE porting is designated by either H in the model code. Fatigue rated aluminum housings are intended for applications up to 10 bar (3000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. For -10-4 and -1-4 housings for V valves see pages -5 & -7 respectively. DIMENSIONS D E F G H I K MSS -10-4 76, 38,1 88,9 50,8 5,4 9,5 36,6 0,8 7,1 1,7 5,5 0,9 (3.00) (1.50) (3.50) (.00) (1.00) (0.37) (1.44) (0.8) (0.8) (0.50) (.07) (.00) -16-4 114,3 60,3 139,7 63,5 31,7 10,3 57,0 8,4 8,7 5,4 85,5,4 (4.50) (.37) (5.50) (.50) (1.5) (0.40) (.4) (1.1) (0.34) (1.00) (3.37) (5.9) -0-4 17,0 63,5 177,8 8,5 41, 10,3 76,5 36,0 8,7 19,0 117,8 4,7 (5.00) (.50) (7.00) (3.5) (1.6) (0.40) (3.01) (1.4) (0.34) (0.75) (4.63) (10.5) kg (lb) -1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
-**-4 Steel housings (NFP fatigue rated) PORTS 1, PRT HOUSING, 3 & 4 NUMER ODE 8 4 1/4 SPP 0 160753 (S)G 3/8 SPP 0 160754 (S)3G SE 4 0 160751 (S)4T SE 6 0 16075 (S)6T 10 4 1/4 SPP 0 175139 (S)G 3/8 SPP 0 175140 (S)3G SE 6 0 175137 (S)6T SE 8 0 175138 (S)8T 16 4 1/ SPP 0 175143 (S)4G 3/4 SPP 0 175144 (S)6G SE 10 0 175141 (S)10T SE 1 0 17514 (S)1T 0 4 1/ SPP 0 175147 (S)4G 3/4 SPP 0 175148 (S)6G SE 1 0 175145 (S)1T SE 16 0 175146 (S)16T Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code 8 series utilize slot in place of mounting hole. Fatigue rated steel housings are intended for applications up to 350 bar (5000 psi) with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. For -10-4 and -1-4 housings for V valves see pages -4 & -7 respectively. L H 3 1 I 4 E D F G Ø K DIMENSIONS D E F G H I K L MSS -8-4* 63,5 31,8 8,6 38,1 19,0 15,5 44,1 3,3 57,1 7,1 73,0 9,8 1, (.50) (1.5) (3.5) (1.50) (0.75) (0.61) (1.74) (0.13) (.5) (0.8) (.88) (1.17) (.70) -10-4 76, 38,1 88,9 44,4, 19,0 50,8 9,5 57,1 7,1 76, 34,9 1,9 (3.00) (1.50) (3.50) (1.75) (0.87) (0.75) (.00) (0.37) (.5) (0.8) (3.00) (1.37) (4.35) -16-4 101,6 50,8 139,7 50,8 5,4 5,4 8,5 1,7 76, 10,3 10,6 53,9 5,6 (4.00) (.00) (5.50) (.00) (1.00) (1.00) (3.5) (0.50) (3.00) (0.40) (4.75) (.1) (1.40) -0-4 114,3 57,1 177,8 63,5 31,7 31,7 113,5 19,0 76, 11,8 15,4 7,1 8, (4.50) (.5) (7.00) (.50) (1.5) (1.5) (4.47) (0.75) (3.00) (0.47) (6.00) (.84) (18.0) * 8 Series housings utilize slot instead of mounting holes. kg (lb) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-13
-**-5S Steel and aluminum housings (NFP fatigue rated) Special housings for PFRD/S only PORTS LUMINUM PRT STEEL PRT HOUSING,3,4 PORT 5 NUMER ODE NUMER ODE 1 5S SE 10 SE 4 4993511-001 ()10T 4994808-001 (S)10T SE 1 SE 4 4993511-00 ()1T 4994808-00 (S)1T 1/ SPP 1/4 SPP 4993511-003 ()04G 4994808-003 (S)04G 3/4 SPP 1/4 SPP 4993511-004 ()06G 4994808-004 (S)06G 16 5S SE 1 SE 4 499351-001 ()1T 4994809-001 (S)1T SE 16 SE 4 499351-00 ()16T 4994809-00 (S)16T 3/4 SPP 1/4 SPP 499351-003 ()06G 4994809-003 (S)06G 1 SPP 1/4 SPP 499351-004 ()08G 4994809-004 (S)08G 0 5S SE 1 SE 4 4993513-001 ()1T 4994810-001 (S)1T SE 16 SE 4 4993513-00 ()16T 4994810-00 (S)16T 3/4 SPP 1/4 SPP 4993513-003 ()06G 4994810-003 (S)06G 1 SPP 1/4 SPP 4993513-004 ()08G 4994810-004 (S)08G Notes SPP porting is designated by G in the model code SE porting is designated by T in the model code. Fatigue rated aluminum and steel housings are intended for applications up to 10 bar (3000 psi) and 350 bar (5000 psi) respectively with harsh duty cycles. These housings have been fatigue rated to NFP standards to one million cycles. 4 -**-5S avity 5 Note Port 1 unused, blind cavity is machined into this housing. ETON HYDRULIS, IN. Model Number 3 "499XXXX-XXX" This number will depend on which manifold is ordered DIMENSIONS D E F G H I K L M DIM. N -1-5S 100,8 50,4 96,3 37,3 18,7 16,7 54,0 34,1 73,8 10, 88,9 1,7 88,9 8,7 (3.97) (1.99) (3.79) (1.47) (0.74) (0.66) (.13) (1.34) (.91) (0.40) (3.50) (0.50) (3.50) (0.34) -16-5S 100,8 51,4 113,5 50,0 5,0 16,9 58,8 36,1 81,3 10, 101,6 1,7 88,9 8,7 (3.97) (.0) (4.47) (1.97) (0.99) (.066) (.34) (1.4) (3.0) (0.40) (4.00) (0.50) (3.50) (0.34) -0-5S 113,5 56,8 16, 75,4 37,7 16,8 6,3 37,6 87,4 10, 114,3 1,7 101,6 8,7 (4.47) (.4) (4.97) (.97) (1.49) (0.66) (.45) (1.48) (3.44) (0.40) (4.50) (0.50) (4.00) (0.34) -14 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Port Key dimensions in all standard housings MINIMUM MINIMUM FULL SE SIZE THRED SIZE SPOTFE Ø THD DEPTH 4 0.437-0 UNF- 1,1 (0.8) 11,5 (0.45) 6 0.563-18 UNF- 4,7 (0.96) 1,7 (0.50) 8 0.750-16 UNF- 30, (1.18) 14, (0.56) 10 0.875-14 UNF- 34, (1.34) 16,6 (0.65) 1 1.06-1 UN- 41,3 (1.6) 19,0 (0.75) 16 1.31-1 UN- 48,6 (1.91) 19,0 (0.75) MINIMUM MINIMUM FULL SPP THRED SIZE SPOTFE Ø THD DEPTH 1/4 4 (0.94) 1, (0.48) 3/8 7 (1.06) 1, (0.48) 1/ 33 (1.9) 15,0 (0.59) 3/4 4 (1.65) 16,3 (0.64) 1 47 (1.85) 19,1 (0.75) Spotface Ø 0,8 (0.03) Min. full thread depth V, PO and V Housings Housing part numbers shown on the following pages are for the counterbalance, vented counterbalance, and pilot-toopen check valves (V1/, V1, PO1). Housing dimensions for inline housings are shown on pages 6, 7 and 9. for other housings are shown on pages -18 to -35. V1/, PO1 VLVE HOUSINGS SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I 3 (3/8 SPP) 0-175470 Inline 6H (SE 6) 876706 Mounted 8H (SE 8) 87671 6T (SE 6) 566413 0-171961 8T (SE 8) 0-1633 10T (SE 10) 0 16333 0 17868 0 160996 1T (SE 1) 0 17869 0 160997 G (1/4 SPP) 876707 3G (3/8 SPP) 876710 0 163313 4G (1/ SPP) 0 16334 0 17870 0 160994 6G (3/4 SPP) 0 17871 0 160995-4-olt Pad 6T (3/4 SE code 61 flange, SE4 pilot port) 0 160801 0 160800 N 6H (SE 6) 0 160853 lose oupled, 6T (SE 6) 0 160851 Nipple Mounted 8T (SE 8) 0 16080 0 160818 3G (3/8 SPP) 0 1734 0 1733 4G (1/ SPP) 0 16081 0 160819 G 6H (SE 6) 0 160845 Gasket 6T (SE 6) 0 160848 Mounted, 8T (SE 8) 0 16084 0 1608 Single 3G (3/8 SPP) 0 160844 0 160847 4G (1/ SPP) 0 16085 0 16083 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-15
V, PO and V Housings (cont.) V1/, PO1 SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL D 6H (SE 6) 0 16089 Dual Line 8H (SE 8) 0 160830 Mounted 10H (SE 10) 0 160831 6T (SE 6) 0 160838 8T (SE 8) 0 160839 10T (SE 10) 0 160840 0 160811 0 160808 1T (SE 10) 0 16081 0 160809 G (1/4 SPP) 0 17191 0 160841 3G (3/8 SPP) 0 160833 0 16084 4G (1/ SPP) 0 160834 0 160843 0 160813 0 160810 P 6H (SE 6) 0 160876 Dual Gasket 6T (SE 6) 0 160873 Mounted 8T (SE 8) 0 160816 0 160814 3G (3/8 SPP) 0 160877 0 160874 4G (1/ SPP) 0 160817 0 160815 M 6H (SE 6) 0 160857 Dual 8H (SE 8) 0 160858 ounterbalance 10H (SE 10) 0 160859 Line Mounted 6T (SE 6) 0 160866 w/integral 8T (SE 8) 0 160867 Shuttle Valve 10T (SE 10) 0 160868 0 160805 0 16080 1T (SE 10) 0 160806 0 160803 G (1/4 SPP) 0 160860 0 160869 3G (3/8 SPP) 0 160861 0 160870 4G (1/ SPP) 0 16086 0 160871 0 160807 0 160804 H 10T (SE 10) 499707-0001 K 10T (SE 10) 4997070-0001 Dual ounterbalance olt on Manifolds for Eaton Hydraulic Motors V VLVE HOUSINGS SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I 6H (SE 6) 876708 Inline 8H (SE 8) *0-178190 Mounted 10H (SE 10) *01-17819 6T (SE 6) 566160 8T (SE 8) *0-178191 10T (SE 10) *0-178193 0-178739 0-17873 1T (SE 1) - *0-178740 *0-178733 -16 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
V, PO and V Housings (cont.) V valve housings SIZE 10 HOUSING PORT LUMINUM SIZE 10 SIZE 10 SIZE 1 SIZE 1 TYPE SIZE LIGHT DUTY LUMINUM STEEL LUMINUM STEEL I G (1/4 SPP) 876709 3G (3/8 SPP) *0-178194 *0 178195 4G (1/ SPP) *0-178741 *0-178734 G 6H (SE 6) 0 160986 Gasket 8H (SE 8) 0 160987 Mounted, 6T (SE 6) 0 178166 Single 8T (SE 8) 0 178167 0 178905 0 178904 3G (3/8 SPP) 0 160989 0 178169 4G (1/ SPP) 0 178903 0 178906 D 6H (SE 6) 0 160990 Dual Line 8H (SE 8) 0 160991 Mounted 6T (SE 6) 0 178170 8T (SE 8) 0 178171 10T (SE 10) 0-178915 0-178916 1T (SE 1) *0-178917 *0-178918 3G (3/8 SPP) 0 160993 0 178173 4G (1/ SPP) - *0 178919 *0 17890 * Housings with slot PPROXIMTE WEIGHT KG. (LS) FOR V, PO & V VLVE HOUSINGS LUMINUM STNDRD LUMINUM STNDRD LUMINUM STEEL STEEL V/PO V LIGHT DUTY V/PO V SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE SIZE HOUSING 10 1 16 10 1 10 10 1 16 10 1 I 0,75 0,8 1,18 0,85 0,95 0,3 1,08,63 3,40 1,3 3,05 (1.65) (1.80) (.60) (1.87) (.09) (0.51) (.40) (5.40) (7.50) (.71) (6.7) 0,86,61 (1.90) (5.75) N 0,49 0,91 1,49,7 (1.10) (.00) (3.30) (6.00) G 0,67 0,73 0,85 0,95,49,15 1,3 3,05 (1.85) (1.60) (1.87) (.09) (5.50) (4.75) (.71) (6.7) D 0,79 1,11 1,77 1,60 1,10,38 3,33 5,14,55 3,70 (1.75) (.45) (3.90) (3.5) (.4) (5.5) (7.35) (11.30) (5.6) (8.15) P 0,7,0,17 5,90 (1.60) (4.40) (4.80) (10.00) H 1,4 (.73) K 1,67 (3.67) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-17
Size 10 Housings V1/ and PO1 I Inline, aluminum & steel PORT SIZE 1 3 6T SE 6 SE 6 SE 6 3 3/8 SPP 3/8 SPP 3/8 SPP See standard inline housings: Light duty housings - page -6 Fatigue rated housings - page -7 Steel housings - page -9 N - lose coupled nipple mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T SE 8 SE 6 3G 3G 3/8 SPP 3/8 SPP See page -15 for housing part numbers. 14, (0.56) 40,6 (1.60) 18,3 (0.7) 18,3 (0.7) 14, (0.56) V 65,5 (.58) 81,8 (3.) V1 37,8 (1.49) 1 59,4 (.34) 45,4 (1.79) avity 75,4 (.97) -18 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Size 10 Housings V1/ and PO1 G - Gasket mounted, single - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T Ø 1,7(0.5) SE 6 3G 3G Ø 1,7(0.5) 3/8 SPP See page -15 for housing part numbers. avity 41,3 (1.63) 56,4 (.) 19,8 (0.78) 7,8 (0.31) Dia. thru 1,7 (0.5) Dia c bore x 6,35 (0.5) places 1 V1 19,1 (0.75) 38,1 (1.50) 6,7 (.47) 94,5 (3.7) 57,9 (.8) V 17,5 (0.69) 15,9 (0.63) 57,9 (.8) 44,5 (1.75) 6,7 (.47) 15,7 (0.6) 38,1 (1.50) 1 Port -113 O-ring D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,,V1,V 6H 6T SE 6 8H 8T SE 8 10H 10T SE 10 G G 1/4 SPP 3G 3G 3/8 SPP 4G 4G 1/ SPP See page -15 for housing part numbers. 36,5 (1.44), (0.88) 77,1 (3.03) artridge cavity 44,5 (1.75) V1 75,4 (.97) 31,8 (1.5) Ø 8,6 (0.34) 63,5 through (.50) places 31,8 (1.5) V 44,5 (1.75),3 (0.88) 16,7 (0.66) 36,5 (1.44), (0.88) 80,6 (3.16) 113,5 (4.47) 77,1 (3.03), (0.88) 44,5 (1.75) 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-19
Size 10 Housings V1/ and PO1 P - Dual gasket mounted - aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL 1,V1,V 6H 6T Ø 1,7(0.5) SE 6 3G 3G Ø 1,7(0.5) 3/8 SPP See page -15 for housing part numbers. 49,5 (1.95) 55,9 (.0) avity 46,1 (1.8) 1 O-Ring 113 114,3 (4.50) 58,4 (.30) avity V 75,4 (.97) 49,5 (1.95) 36,6 (1.44) 31, (1.3) 14, (0.56) 6,7 (.47) 8,6 (0.34) diameter c'bore x 6,35 (0.5) deep plcs. 49.5 (1.95) 16,3 (0.64) 46,7 (1.84) V1,1 (0.87) M - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, LUMINUM STEEL V1,V S 6H 6T SE 6 SE 4 8H 8T SE 8 SE 4 10H 10T SE 10 SE 4 G G 1/4 SPP 1/4 SPP 3G 3G 3/8 SPP 1/4 SPP 4G 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. V1 31,8 (1.5) 75,4 (.97) avity 8,6 (0.34) Dia. thru plcs. S 31,8 44,5 (1.5) (1.75) 63,5 (.5) V 44,5 (1.75) 16,8,3 (0.66) (0.88) 93,5 (3.68) 63,5 (.5) 17,0 (5.00),3 (0.88),3 (0.88) 44,5 (1.75) 90,4 (3.56) 36,6 (1.44) 1-0 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Size 1 Housings V1/ and PO1 I - Inline body - aluminum and steel (NFP fatigue rated) PORT YLINDER- VLVE- PILOT- SIZE PORT (1) PORT () PORT (3) 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 3/8 SPP 6G 3/4 SPP 3/8 SPP See page -15 for housing part numbers. See standard inline housings: luminum housings - page -7 Steel housings - page -9-3/4 4-olt Pad - aluminum and steel (NFP fatigue rated) PORT SIZE 1 PILOT- PORT 6T 3/4 SE 4 bolt SE 6 ode 61 See page -15 for housing part numbers. V 1,7 (0.5) 0.375-16 x 0.875 deep, places 6,7 (.47) 47,6 (1.88) 31,8 (1.5) 7,9 (0.3) 100,8 (3.97) 5,4 (.06) 63,5 (.5) avity Pilot Pilot 7,9 (0.31) 8,6 (1.13) 77,8 (3.06) 19,1 30, (1.19) (0.75), (0.88) 8,6 (1.13) 11, 8 (1.5) 6,7 (.47) 8,6 (1.13) 77,8 (3.06) 31,8 (1.5) 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-1
Size 1 Housings V1/ and PO1 N - lose coupled nipple mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1, V1, V 8T 1/ NPTF SE 8 4G 1/ SPP 1/ SPP See page -15 for housing part numbers. artridge cavity V 7, (.84) 39,7 (1.56) 7, (.84) V1 88,1 (3.47) 1 39,7 (1.56) 0,6 (.81) 33,3 (1.31) 50,0 (1.97) 15,9 (0.63) 0,6 (0.81) 33,3 (1.31) 69,9 (.75) 100,8 (3.97) G - Gasket mounted, single - aluminum and steel (NFP fatigue rated) PORT SIZE 1, V1, V 8T Ø 15,8(0.65) SE 8 4G Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. 10,3 (0.41) Dia. thru 15,0 (0.59) dia. c'bore x 7,8 (0.31) deep, places artridge cavity 70,6 (.78) V1 6,7 (.47) V 45, (1.78) 1 Port O-Ring 117 45,3 (1.79) 17,5 (0.69) 17,4 (0.69) 45,4 (1.79) 3,0 (0.91) 67,5 (.66) 75,4 (.97) 19,1 (0.75) 44,5 (1.75) 6,7 (.47) 3,1 (0.91) 70,6 (.78) 113,5 (4.47) - ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Size 1 Housings V1/ and PO1 D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, V1, V 10T SE 10 1T SE 1 4G 1/ SPP See page -15 for housing part numbers. artridge cavity V1 4,0 (1.66) 76, 88,1 (3.00) (3.47) 10,3 (0.41) dia. thru places 4,0 (1.66) V 50,8 (.00) 5,4 (1.00) 40,9 (1.61) 88,9 (3.50) 16, (4.97) 96,1 (3.91) 5,4 (1.00) 5,4 (1.00) 1 P - Dual gasket mounted (NFP fatigue rated) PORT SIZE 1, V1, V 8T Ø 15,8(0.65) SE 8 4G Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. artridge cavity 6,9 (1.06) 68,3 (.7) 88,0 (3.47) 88,1 (3.47) 58,3 (.30) 44,7 (1.76) 35,8 (1.40) 9,8 (1.18) 133,4 (5.5) 67,9 (.67) 10.3 (0.41) dia. thru, 15.0 (0.59) dia. c"bore x 7.9 (0.31) deep, places 7,1 (1.06) artridge cavity V V1 7,1 (1.06) 50,1 (1.97) 68,9 (.7) 88,1 (3.47) 67,8 (.67) 1 - O-Ring 117 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-3
Size 1 Housings V1/ and PO1 M - dual line mounted - with integral shuttle, counter balance only (NFP fatigue rated) 1, PORT SIZE V1, V S 10T SE 10 SE 4 1T SE 1 SE 4 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. artridge cavity V1 4,0 (1.66) 88,1 (3.47) 10,3 (0.41) dia. through, places S 56,4 (.5) 76, (3.00) 4,0 (1.66) V 50,8 (.00) 5,4 (1.00) 39,7 (1.56) 5,4 (1.00) 1,7 (0.50) 101,6 (4.00) 69,5 (.74) 16, (4.97) 86,5 (3.41) 1 5,4 (1.00) -4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Size 10 Housings V1-10 I - Inline body - aluminum, light duty PORT SIZE 1,, 3 & 4 6T SE 6 See page -15 for housing part numbers. 15,8 (0.6) 31,7 (1.5) artridge cavity 63,5 (.50) 31,7 (1.5) 19,0 (0.75) 3 34,9 (1.37) 50,8 (.00) 8,5 (3.5) 4 3,1 (0.1) 7,1 (0.8) places 1 I - Inline body - aluminum (NFP Fatigue Rated) PORT SIZE 1 & 3 & 4 8H SE 8 SE 6 10H SE 10 SE 6 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers. 5,4 (1.00) 50,8 (.00) 5,4 (1.00) 3 9,5 (0.37) artridge cavity 88,9 (3.50) 76, (3.00) 38,1 (1.50) 76, (3.00) 19,0 (0.75) 5,4 (1.00) 4 50,8 (.00) 57, (.5) 7,1 (0.8) places 1 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-5
Size 10 Housings V1 I - Inline body - Steel (NFP fatigue rated) PORT SIZE 1 & 3 &4 6T SE 8 SE 6 8T SE 10 SE 6 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers., (0.87) 3 9,5 (0.37), (0.87) artridge cavity 88,9 (3.50) 76, (3.00) 44,4 (1.75) 38,1 (1.50) 76, (3.00) 19,0 (0.75) 5,4 (1.00) 4 50,8 (.00) 57, (.5) 7,1 (0.8) places G - Gasket mounted, single aluminum and steel (NFP fatigue rated) PORT SIZE LUMINUM STEEL VENT 1, V1, V 6H 6T SE 6 Ø 1,7 SE 6 (0.500) N/ 8T SE 6 Ø 1,7 SE 8 (0.500) 3G 3G 1/4 SPP Ø 1,7 3/8 SPP (0.500) See page -15 for housing part numbers. 1 V1 artridge cavity 36,5 (1.44) 15,7 (0.6) 46,7 (1.84) 75,4 (.97) 65,0 (.56) 8,4 (1.1) 9, (1.15) 75,4 (.97) 36,5 (1.44) 15,7 (0.6) 1 Port -113 O-ring 46,7 (1.84),3 (0.88) 7,8 (0.31) Dia. thru 1,7 (0.5) c'bore x 6,35 (0.5) deep places 50,8 (.00) 100,8 (3.97) 81,7 (3.) Vent -6 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Size 10 Housings V1 D - Dual line mounted - aluminum and steel (NFP fatigue rated) PORT SIZE 1,, LUMINUM STEEL V1 & V VENT 6H 6T SE 6 SE 4 8H 8T SE 8 SE 4 3G 3G 3/8 SPP 1/4 SPP See page -15 for housing part numbers. 31,7 (1.5) 31,7 (1.5) artridge cavity places 68,0 (.68) 50,8 V 88,1 (.00) (3.47) 75,4 Ø 8,6 (0.34) (.97) places 50,8 (.00) 19,0 Vent (0.75) V1 34,0 (1.34) 16,7 (0.66) 31,7 (1.5) 31,7 (1.5) 8,5 (3.5) 100,8 (3.97) 68,0 (.68) 3,1 (0.91) 31,7 (1.5) 50,0 (1.97) 50,0 (1.97) 1 Size 1 Housings V1 artridge cavity 88,9 (3.50) 5,4 (1.00) 44,5 ( 1.75) 50,8 (.00) 5,4 (1.00) Tank port I - Inline body - luminum and Steel PORT SIZE 1 & 3 & 4 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. 3 51,6 (.03) Pilot port 10,6 (4.75) 10,7 (0.4) dia. through, places ylinder port 1 57,1 (.5) 1,7 (0.50) 44,5 (1.75) 8,7 (1.13) Valve port 4 74,5 (.93) ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-7
Size 1 Housings V1 G - Gasket mounted, single aluminum and steel (NFP fatigue rated) PORT SIZE VENT 1, V1, V 8T SE 6 Ø 15,8(0.65) SE 8 4G 1/4 SPP Ø 15,8(0.65) 1/ SPP See page -15 for housing part numbers. V V1 36,5 (1.44) 16,7 (0.66) 5,5 (0.7) 88,1 (3.47) 36,8 (1.75) 3,7 (1.9) 31,7 (1.5) 75,4 (.97) 36,5 (1.44) 16,7 (0.66) 1 Port -117 O-ring 54,8 (.16) 19,0 (0.75) 10,4 (0.41) Dia. thru 14,9 (0.59) c'bore x 7,87 (0.31) deep places 50,8 (.00) 13,5 (5.) 103,8 (4.09) Vent artridge cavity D - Dual line mounted - aluminum and steel (NFP fatigue rated) 1,, PORT SIZE V1 & V VENT 10T SE 10 SE 6 1T SE 1 SE 6 4G 1/ SPP 1/4 SPP See page -15 for housing part numbers. 41, (1.6) 5,4 (1.00) artridge places 85,3 (3.36) 74,7 V 10,6 (.93) (4.75) 107,9 Ø10,6 (0.4) (4.5) places 74,4 (.93) 45,7 Vent (1.80) V1 37,9 (1.49) 19,0 (0.75) 41, (1.6) 37,3 (1.47) 88,9 (3.50) 16, (4.97) 85,3 (3.36) 8,5 (1.1) 37,3 (1.47) 6,7 (.47) 6,7 (.47) 1-8 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Special Housings olt on Solutions artridge Valves & Manifolds for Spool & Disk Valve Motors We Manufacture Solutions Designing hydraulic systems with Eaton-Vickers artridge Valves & Manifolds is a cost effective way of bringing your design into production well within the most demanding of production schedules. Minimizing the use of hoses, tubing and fittings will reduce production and assembly time significantly. Features ompatible with Eaton H & T series spool valve motors, and most 000 series disk valve motors luminum Manifolds nodized lack Pre-set cartridges to your specifications 100% production tested assembly Wide range of settings available Intelligent model code Manifolds are available with out cartridge valves, or pre-assembled and tested to your specifications Manifolds and motors can be supplied as a pre-assembled package Dual counterbalance valve (with integral shuttle valve), dual pilot operated check valve and dual cross port relief valve packages are available Eaton H Series Hydraulic Motor ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-9
Dual V Package for H&T Series Motors artridge valves & manifolds for spool valve motors Dual ounterbalance Valve ssembly with rake Release Shuttle When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. It will also prevent motor overspeed when exposed to an overrunning load, and will control motor deceleration to a stop. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. Typical applications are swing drives, winch drives, and vehicle propulsion circuits. If the shuttle is not required the rake port may be plugged. Functional Symbol How to Order omplete pre-assembled packages are specified using the V*-10 model code, position 6 of RTINGS ND SPEIFITIONS the model code is H. To order the manifold subassembly, without the two V valves, but with rake SE4 6,74 [.470] integral shuttle valve order 499707-001. Rated flow 60L/min(15USgpm) Rated pressure 10 bar (3000 psi) Internal leakage (maximum) 5 drops/min max @ 77% of crack pressure Pilot ratio 4:1 or 10:1 Manifold sub-assembly only 499707-001 Installation kit (includes cap screws, washers and o-rings) 49974-001 For detailed specifications refer to the V*-10 data sheet on page H-6 Port Sizes, SE10 rake 88,14 [3.470] 53,4 [.103] 63,5 [.500] "" "" 31,74 [1.50] 57,15 [.50] "" "" ETON HYDRULIS, IN. Model Number 499707-001 "rake" 100,84 [3.970] 1,7 [0.500] 4XØ 8,71 [0.343] 19,53 [0.769] 44,45 [1.750] 69,37 [.731] -30 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Dual PO Package for H&T Series Motors artridge valves and manifolds for spool valve motors Dual Pilot Operated heck Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. lthough it not designed to modulate the flow of oil to or from the motor, it will also prevent motor runaway if an overrunning load exists in the powered mode. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. If the shuttle is not required the rake port may be plugged. How to Order omplete pre-assembled packages are specified using the PO1-10 model code, position 6 of the RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar(3000psi) Internal leakage (maximum) less than 5 drops/min @ 3000psi Pilot ratio 3:1 Manifold sub-assembly 499707-001 Installation kit (includes cap screws, washers and o-rings) 49974-001 For detailed specifications refer to the PO1-10 data sheet on page G-36 model code is H. To order the manifold sub-assembly, without the two PO1 valves, but with integral shuttle valve order 499707-001. Functional Symbol 6,74 [.470] Port Sizes, SE10 rake SE4 88,14 [3.470] 7,16 [0.8] rake "" 63,5 [.500] "" ETON HYDRULIS, IN. Model Number 499707-001 "" "rake" "" 31,74 [1.50] 57,15 [.50] 100,84 [3.970] 1,7 [0.500] 4XØ 8,71 [0.343] 44,45 [1.750] 69,37 [.731] 19,53 [0.769] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-31
Dual ross-over Relief Package for H&T Series Motors artridge valves & manifolds for spool valve motors Dual rossover Relief Valve ssembly This valve assembly provides motor overpressure protection in both directions of rotation, while supplying the return or lower pressure side of the motor with makeup oil. If closed center valving is used, an additional function is controlled braking. Typical applications are vehicle propulsion and motor work circuits in which pressure limiting is required. How to Order omplete pre-assembled packages are specified using the RV3-10 model code. Option must be RTINGS ND SPEIFITIONS Rated flow 76 L/min(0USgpm) Rated pressure 10 bar (3000psi) Internal leakage (maximum) less than 5 drops/min @ 85% of nominal setting Manifold sub-assembly only 499706-001 Installation kit (includes cap screws, washers and o-rings) 49974-001 For detailed specifications refer to the RV3-10 data sheet on page E-1 selected for the cage seals, position 6 of the model code is H. To order the manifold separately, without the two RV3 cartridges, order the part number 499706-001. Functional Symbol Port Sizes, SE10 rake SE4 5,5 [.057] 4XØ 8,71 [0.343] 50,8 [.000] ETON HYDRULIS, IN. "" 4,13 [0.950] 88,14 [3.470] 65,0 [.560] "" 69,85 [.750] "" Model Number 499706-001 "" 4,13 [0.950] 44,45 [1.750] 6,74 [.470] 1,98 [0.078] 75,44 [.970] 1,98 [0.078] -3 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Dual ross-over Relief Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual rossover Relief Valve ssembly This valve assembly provides motor overpressure protection in both directions of rotation, while supplying the return or lower pressure side of the motor with makeup oil. If closed center valving is used, an additional function is controlled braking. Typical applications are vehicle propulsion and motor work circuits in which pressure limiting is required. Functional Symbol How to Order omplete pre-assembled packages are specified using the RV3-10 model code. Option must be selected for the cage seals, RTINGS ND SPEIFITIONS position 6 of the model code is K. To order the manifold separately, without the two RV3 cartridges, order 4997060-001 Rated flow 76 L/min(0USgpm) Rated pressure 10 bar (3000psi) Internal leakage (maximum) less than 5 drops/min @ 85% of nominal setting Manifold sub-assembly only 4997060-001 Installation kit (includes cap screws, washers and o-rings) 0-3749 For detailed specifications refer to the RV3-10 data sheet on page E-14 Port Sizes, SE10 rake SE4 WRNING This manifold package may not be suitable for application with all 000 series motors - please check installation dimensions carefully. 5,5 [.057] 3XØ10,31 [0.406] "" 44,45 [1.750] ETON HYDRULIS, IN. Model Number 4997060-001 "" "" 56,03 [.06] 8,55 [3.50] 100,84 [3.970] 6,35 "" [0.50] 53,85 [.10] 8,45 [1.10] 6,74 [.470] 1,98 [0.078] 88,14 [3.470] 1,98 [0.078] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-33
Dual V Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual ounterbalance Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. It will also prevent motor overspeed when exposed to an overrunning load, and will control motor deceleration to a stop. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. Typical applications are swing drives, winch drives, and vehicle propulsion circuits. If the shuttle is not required the rake port may be plugged. Functional Symbol How to Order omplete pre-assembled packages are specified using the V*-10 model code, position 6 of the RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar (3000 psi) Internal leakage (maximum) 5 drops/min max @ 77% of crack pressure Pilot ratio 4:1 or 10:1 Manifold sub-assembly only 4997070-001 Installation kit (includes cap screws, washers and o-rings) 0-3749 For detailed specifications refer to the V*-10 data sheet on page H-6 6,74 [.470] model code is K. To order the manifold subassembly, without the two V valves, but with Port Sizes, SE10 rake SE4 integral shuttle valve order 4997070-001. WRNING This manifold package may not be suitable for application with all 000 series motors - please check installation dimensions carefully. rake 100,84 [3.970] 53,4 [.103] 57,15 [.50] ETON HYDRULIS, IN. Model Number 4997070-001 "" "" 31,74 [1.50] 76,81 [3.04] 113,54 [4.470] "" "rake" 17,78 [0.700] "" 3XØ 10,31 [0.406] 50,8 [.000] 76,87 [3.07] 3,46 [0.94] -34 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Dual PO Package for 000 Series Disc Valve Motors artridge valves & manifolds for disc valve motors Dual Pilot Operated heck Valve ssembly When the motor is in a stationary, unpowered mode, this assembly will prevent excessive drift in either direction of rotation. lthough it not designed to modulate the flow of oil to or from the motor, it will also prevent motor runaway if an overrunning load exists in the powered mode. shuttle within the assembly provides a pilot to release a parking or holding brake as either motor port is pressurized. If the shuttle is not required the rake port may be plugged. How to Order omplete pre-assembled packages are specified using the PO1-10 model code, position 6 of the model code is K. To order the manifold subassembly, without the two PO1 valves, but with integral shuttle valve order 4997070-001. RTINGS ND SPEIFITIONS Rated flow 60L/min(15USgpm) Rated pressure 10 bar(3000psi) Internal leakage (maximum) less than 5 drops/min @ 3000psi Pilot ratio 3:1 Manifold sub-assembly only 4997070-001 Installation kit (includes cap screws, washers and o-rings) 0-3749 For detailed specifications refer to the PO1-10 data sheet on page G-36 Port Sizes, SE10 rake SE4 Functional Symbol 6,74 [.470] 100,84 [3.970] 7,16 [0.8] rake 57,15 [.50] ETON HYDRULIS, IN. Model Number 4997070-001 "" "" 31,74 [1.50] 76,81 [3.04] 113,54 [4.470] "" "rake" 17,78 [0.700] "" 3XØ 10,31 [0.406] 50,8 [.000] 76,87 [3.07] 3,46 [0.94] ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-35
avity Plugs STNDRD PLUGS Note To block flow from between the ports in any unused standard cavity, in a housing or manifold. Order cavity plugs by part number. -**- avity Plugs SIZE SSY. NO. SEL KIT To fit una-n cavity ød Viton -8-0.750-16 9,1 7,8 1,6/1,5 0-171585 0-165877 (0.36) (1.09) (0.498/0.496) 0-165875 -10-0.875-14 7,9 31,7 15,8/15,7 565814 565806 (0.30) (1.5) (0.6/0.6) 88967-1- 1.06-1 18,7 44,5 3,7/3,7 0-171710 0-165889 (0.74) (1.75) (.936/.934) 0-165888 -16-1.31-1 1,7 44,5 8,5/8,5 565816 889631 (0.50) (1.75) (1.1/1.1) 889635-0- 1.65-1 13,5 57, 36,4/36,4 566440 889639 (0.53) (.5) (1.43/1.43) 889643 Thread 1 D -**-3(S) avity Plugs Thread 3 1 D E SIZE SSY. NO. SEL KIT To fit una-n cavity D E Viton -8-3 0.750-16 9,1 40,7 14,/14,0 15,8 0-171708 0-160755 (0.36) (1.60) (0.56/0.55) (0.63/0.61) 0-160765 -10-3S 0.875-14 7,9 74, 17,4/17,4 19,0/18,9 566436 0-173019 (0.30) (1.86) (0.68/0.68) (0.74/0.74) 0-17300 -10-3 46,0 15,8/15,7 17,4/17,3 565815 88964 (1.81) (0.6/0.6) (0.68/0.68) 88968-1-3S 1.06-1 18,7 57,7,1/, 1 3,7/3,7 0-171711 0-180095 (0.74) (.7) (0.874/0.87) (0.936/0.934) 0-165887 -1-3 67,1 0-17171 0-16587 (.64) 0-165886 -16-3S 1.31-1 1,7 55,6 5,3/5,3 8,5/8,5 566438 889633 (0.50) (.18) (0.99/0.99) (1./1.) 889637-16-3 73,1 6,9/6,9 8,5/8,5 566437 88963 (,87) (1.06/1.06) (1./1.) 889636-0-3S 1.65-1 13,5 76. 33,3/33, 36,4/36,4 56644 0-113153 (0.53) (3.0) (1.31/1.30) (1.43/1.43) 0-11969 -0-3 98.5 33,3/33, 36,4/36,4 566441 889640 (3.87) (1.31/1.30) (1.43/1.43) 889644-36 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
avity Plugs -**-4 avity Plugs 4 3 Thread TO FIT SSY VITY SIZE D ØE ØF ØG NO. -8-4 0.750-16, (0.87) hex. 8,6 54,6 1,6 14, 15,8 0-171709 Torque 35-40 (0.34) (,15) (0.49) (0.55) (0.6) Nm(5-30 lbf ft) -10-4(U) 0.875-14 5,4 (1.0) hex. 7,9 61,9 15,8/15,7 17,4/17,3 19,0/18,9 56644 Torque 47-54 (0.31) (.43) (0.6/0.6) (0.68/0.68) (0.74/0.74) Nm (35-40 lbf ft) -16-4 1.31-1 38,1 (1.50) hex. 1,7 101.6 5,3/5,3 6,9/6,9 8,5/8,5 566439 Torque 109-1 (0.50) (4.00) (0.99/0.99) (1.06/1.05) (1.1/1.1) Nm (80-90 lbf ft) -0-4 1.65-1 47,6 (1.87) hex. 13,5 139,7 31,7/31,6 33,3/33, 36,4/36,4 566433 Torque 19-156 (0.53) (5.50) (1.4/1.4) (1.31/1.30) (1.43/1.43) Nm (95-115 lbf ft) 1 D E F IMPORTNT The cartridges listed are complete with seals compatible with antiwear hydraulic oil. If cartridges are to be compatible with antiwear and phosphate ester, order cartridges by part number plus the appropriate Viton seal kit as listed in Spare parts. efore using the cartridge, change the seals to Viton. Special purpose cavity plugs Functional Symbols Filter cartridge plugs TO FIT VITY SIZE SSY. NO. SEL KIT -10-0-186758 566806 (una-n) 88967 (Viton ) Screen fitted on cartridge, intended direction of flow is from port to 1 only. Maximum rated flow is 76 L/min (0 USgpm), maximum operating pressure is 350 bar (5000 psi) 1 Special 3 way cavity plugs 1 3 3 1 Special 4 way cavity plugs 1 TO FIT VITY SIZE SSY. NO. SEL KIT -8-3 0-186664 0-160755 (una-n) 0-160756 (Viton ) -10-3S 0-18557 0-173019 (una-n) 0-17300 (Viton ) TO FIT VITY SIZE SSY. NO. SEL KIT -10-3 0-161831 88964 (una-n) 88968 (Viton ) TO FIT VITY SIZE SSY. NO. SEL KIT -8-4 0-179151 0-160757 (una-n) 0-160758 (Viton ) 3 4 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-37
Orifice Discs lank Orifice Discs (Flat) lank Orifice Discs (Flat) lank Orifice Discs (Flat) lank Orifice Discs (Flat) Note For predrilled orifice discs, consult factory. n orifice disc is installed at the bottom of a standard cavity to create a local pressure drop in the flow to and from port 1 of the cartridge. Two series of discs are available according to the maximum pressure drop required: 1. Flat discs/maximum pressure drop/13,8 bar (00 psi).. onical discs/maximum pressure drop/10 bar (3000 psi). MX PRESSURE VITY DROP R SSY SIZES (PSI) Ø Ø NUMER -8-/4 13,8 (00) 1,45 (0.490) 1,7 (0.050) * 0 16354-10-/3/4 13,8 (00) 5,80 (0.6) 15,75 (0.60) 1,5 (0.060) * 0 16850-16- 13,8 (00) 8,58 (1.15) 8,5 (1.13),03 (0.08) * 0 174507-16-3 13,8 (00) 6,97 (1.06) 6,9 (1.060),03 (0.08) * -16-3S/4 13,8 (00) 5,4 (1.00) 5,35 (0.998),03 (0.08) * *User to specify ± 0,05 (0.001) Ø lank Orifice Discs (onical) MX PRESSURE VITY DROP R SSY SIZES (PSI) Ø Ø Ø D E F NUMER -8-/4 10 (3000) 3,96 (0.156) 5,84 (0.30) 1,45 (0.490) 1,90 (0.075) 3,05 (0.10) 0 174854-8-3 10 (3000) 3,96 (0.156) 5,84 (0.30) 14,05 (0.553) 1,90 (0.075) 3,05 (0.10) 0 178181-10- 10 (3000) 5,54 (0.18) 6,35 (0.50) 15,80 (0.6) 1,14 (0.045) 3,56 (0.140) 566478 15,75 (0.60) -1-10 (3000) 7,14 (0.81) 3,70 (0.933),41 (0.095) 3,56 (0.140) 1,14 (0.045) 0-1884 3,65 (0.931) Orifice diameter ± 0,05 (0.001) To abut port 1 of cartridge 10 10 D F D E -38 ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003
Orifice Disc Sizing Guide (mm) Select required orifice diameter using the graph below Flow - L/min 114 110 106 10 98 95 91 87 83 79 76 7 68 64 61 57 53 49 45 4 38 34 30 6 3 19 15 11 8 4 0 1.4 0.7 3.4 15.4 1.8 10. 5. 6.9 8.9 137.9 17.4 06.9 30 9 0 10 0 50 75 100 150 00 300 400 500 600 700 800 900 1000 1500 000 500 3000 dp - (psi) Note This chart is calculated at 1.8 cst and 49 for ISO VG3 fluid (DTE-4), values will change with viscosity changes. 10.3 13.8 8. 7.7 7. 6.8 0.7 6.6 6.4 6.1 dp - (bar) 34.5 48.3 6.1 7.6 41.4 55. 69.0 5.9 5.6 5.4 5.1 Note To calculate orifice diameter at other flows and differential pressures use the following formula: D=1.350 x (Q/( dp) 4.9 4.6 4.4 4.1 103.4 3.8 3.6 Note where D= orifice diameter in millimeters; Q= flow in liters per minute; dp= differential pressure across orifice in R. 3.3 3.0.8.5.3.0 1.8 1.5 1.3 1.0.75.50.35 8 7 6 5 4 3 1 0 19 18 17 16 15 14 13 1 11 10 9 8 7 6 5 4 3 1 Flow - USgpm ETON Vickers Screw-in artridge Valves V-VLOV-M001-E1 une 003-39