BRAVER UPS. (Uninterruptible Power System) User s Manual

Similar documents
USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

USER MANUAL. Uninterruptible power supply MODEL: 53965,

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

1. INTRODUCTION. Features:

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

General Precautions. Personnel Precautions

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Uninterruptible Power Supply

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

MM-AVR UPS Series User s Manual

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Limousin II User Manual

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Uninterruptible Power System

CP900EPFCLCD User s Manual K

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

UTILITY INPUT MAINS OUTLET

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Uninterruptible Power System

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

PR1000ELCD / PR1500ELCD User s Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

USER MANUAL MPS 1-5KW SERIES

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Uninterruptible Power System

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Installation and Operation Manual Back-UPS BX1100CI-CN

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

USER MANUAL ONLINE UPS

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Uninterruptible Power System

Installation and Operation Manual Back-UPS BR800/1100CI-IN

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

POWERWARE User s Guide VA.

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Installation and Operation Back-UPS BX550CI-CN

User Manual V1.0 MaxiFlex 3000

Liebert GXT MT+ User Manual VA Installer/User Guide

Pulsar Evolution 2200/3000/3000 XL

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

SCC-MPPT Solar Charge Controller

1. Important Safety Warning

Solar Charge Controller

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

SCC-MPPT Solar Charge Controller

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Informer Compact Series

User Manual Rittal PMC UPS 6kVA

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

OWNER S MANUAL POWER INVERTER

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

400 Watt Backup Power System Owner s Manual

SCC-MPPT Solar Charge Controller

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

Powerware Vdc Extended Battery Cabinet User s Guide.

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual Legend SB825 UPS K

Liebert PSA VA. Installer/User Guide

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

02/15/01. Powerware User s Guide VA.

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

USER MANUAL DN / DN

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Back-UPS CS Back-UPS CS 350

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

FALCON ELECTRIC, INC.

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

.$/,7*76(7$ /HDI %ORZHU USER MANUAL

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

ALLIANCE SERIES OWNER'S MANUAL

Transcription:

BRAVER UPS (Uninterruptible Power System) User s Manual

Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only authorized service personnel may perform repairs. Internal battery voltage is 12V DC. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in location where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of batteries in a fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions should be taken. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number of the sealed lead-acid batteries. The socket-outlet shall be installed near the equipment and easily accessible. With the installation of the UPS, it should be prevented that the sum of (UPS and) the connected (load) leakage current exceeds 3.5mA. This pluggable type A equipment with battery installed by the supplier is operator installable and may be operated by laymen. Attention!! Hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside of the UPS is necessary.

System Description Front Panel 1. Power Switch & LED Indicator 2. LED Indicators -- AC Mode: Green Lighting Battery Mode: Yellow Flashing Fault Mode: Red Lighting 1. Power switch 2. LCD display

Back Panel 1. Output receptacles 2. AC Input with AC fuse 3. Modem/Phoneline Surge Protection 4. Communication Port

Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 20cm to avoid interference. 3. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours.

4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). 5. Modem / Phone line Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket as shown.

6. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the RS-232 serial cable as per diagram below. 7. Turn On/Off To turn on the UPS, press power switch lightly. To turn off the UPS, please press power switch again. 8. DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. 9. Green Power Function Braver UPS is equipped with Green Power Function. For saving power and protecting battery, the method of deep discharging protection is adopted on inverter mode.

Software Installation WinPower-XP WinPower-XP is a UPS monitoring software, which provides user-friendly interface to monitor and control your UPS.

Trouble Shooting Symptom Possible Cause Remedy No LED display 1. Battery weak. 1. Re-charge battery up to 8 hours. on the front 2. Battery defect. 2. Replace with the same type of panel. battery. 3. Power switch is not 3. Press the power switch again. pressed. Alarm buzzer beeps continuously when AC supply is normal. When power failure, backup time is shorten. Communication lost between UPS and computer. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs. 1. Overload of the UPS. 1. Remove some non-critical load. 2. Battery voltage is too low. 2. Charge battery 8 hours or more. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 1. Software is not installed well. 2. Cable is not properly connected. 3. Replace with the same type of battery. 1. Check the setting of the software. 2. Check the RS-232 cable is firmly connected to COM1/COM2 of the computer and confirm the setting again. Mains normal 1. Fuse is blown. 1. Replace the same type of fuse. but orange LED 2. Power cord is loose. 2. Reconnect the power cord is on. properly. 3. Battery defect. 3. Replace the same type of battery. If any abnormal situations occur that are not listed above, please call service people immediately.

Specifications MODEL Braver UPS CAPACITY VA 400VA 600VA 800VA Voltage Range 170-280V AC Frequency 40Hz above Voltage 230V AC Voltage Regulation (Battery Mode) + / - 10% Frequency 50Hz or 60Hz OUTPUT Frequency Regulation + / - 1 Hz (Battery Mode) Output Waveform Modified Sinewave BATTERY Battery Type 12V, 4.5Ah 12V, 7Ah 12V, 9Ah Recharge Time 8 hours to 90% after complete discharge TRANSFER TIME Typical 4-8ms INDICATOR AC Mode Green light Backup Mode Orange light flashing Backup Mode Beeping every 10 seconds Low Battery Beeping every second AUDIBLE ALARM Overload Beeping every 0.5 seconds Battery Defect Beeping every 2 seconds Fault Continuously Beeping PROTECTION Full Protection Discharge, overcharge, and overload protection PHYSICAL ENVIRONMENT INTERFACE Dimension (mm), D x W x H 330 x 100 x 140 mm Net Weight 5 kgs 6kgs 6.5kgs Operating 40, 0-90 % relative humidity Environment (non-condensing) Noise Level Less than 40dB Smart RS-232 yes USB Optional