PRO REMOTE 25 LV CAPACITANCE PROBE

Similar documents
PRO REMOTE Series CAPACITANCE PROBE

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

BMRX Series Rotary Level Indicator

BMRX Series ROTARY LEVEL CONTROL

CVR-625. Compact Vibrating Rod Instruction Manual

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors

TS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

ASG-2000 SiloGauge Remote Unit

TABLE OF CONTENTS SPECIFICATIONS...3 SAFETY SUMMARY...4 INTRODUCTION...5, 6 INSTALLATION...7, 8, 9, 10 TESTING THE REMOTE OPERATION AIR PURGE...

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

PRODUCT INFORMATION BULLETIN

MAXIGARD A2000 SPEED SWITCH. Introduction

P U L S A R point 210

Instruction Manual Princo Model L3545

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

LTX RF LEVEL SENSOR. Instruction Manual

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ROTARY Point Level Measurement for Inventory Control

TrueCap RF Capacitance Level Sensor

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

FHC-1D user manual. Features

TC26-B Vehicle Sensor

Installation, Operation & Maintenance Instructions

Electric Actuator Installation, Operation & Maintenance Manual

CAPACITANCE LEVEL SWITCH

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

RF Point Level Control with Sensor Monitor

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Super-Safe-Plus Roto-Bin-Dicator

Excellence in Level Measurement

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Operations Manual. Zero Speed Switch Sensor Model ZS09P

DIAMOND POINT VIBRATING PROBES

Model RP310 Owner's Manual & Installation Instructions

MODEL Q-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

180w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-1800HC14

SOLAR BOLT CHARGING SYSTEM INSTALLATION GUIDE

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

Sensor SNS06 Shown. Monitor. Toughened Nut Sensor Installation Instructions With thread detection calibration procedures. 1.

Lint Slide Grid Moist Air Applicator

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Product Description. Installation Instructions. Fig. A

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

AUTO-BREEZE Cotton Candy Machine Instruction Manual Model #3052

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

CSA CERTIFIED Conforms to UL 507

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

C3000 SIGNAL TRANSMITTER. Introduction

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Spring Mount SAB30403 (Sold Separately)

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

R F C a p a c i t a n c e TrueCap

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

A419ABG-3C Electronic Temperature Control

TRAC-3 TENSION READOUT AND CONTROL

Boston Gear Ratiotrol DC Motor Speed Control

Mini-Roto TM Paddle Wheel Installation & Operation Manual

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

Surepowr Series 100 Installation Manual

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Level limit switch Series RF 3000 Selection list

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Quarter Master Chief Series 92 Actuator

CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch

Read this entire manual before operation begins.

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Installation & Operation Manual Chef Base

Installation Instructions

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

Installation Instructions

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Surepowr Series Sure 150

Transcription:

Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Email : hvssystem@hvssystem.com Site web : www.hvssystem.com

TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4 3.0 INSTALLATION...4 3.1 Location and Mounting...4 3.2 Input Power and Field Wiring...5 3.3 Wiring between Probe Head and Electronic Console...5 4.0 FAIL-SAFE SELECTION...6 4.1 Description...6 4.2 Fail-Safe High...6 4.3 Fail-Safe Low...6 5.0 CALIBRATION...7 5.1 Calibration Verification...7 5.2 Calibration Procedure...7 5.3 Sensitivity Selection...8 6.0 TIME DELAY...8 7.0 WARRANTY AND CUSTOMER SERVICE...8 7.1 LIMITED WARRANTY...8 7.2 CUSTOMER SERVICE...8 FIGURE 1.1...9 FIGURE 1.2...10 FIGURE 1.3...11 FIGURE 1.4...12 FIGURE 1.5...13 FIGURE 2.1...14

PRO REMOTE 25 LV GENERAL SPECIFICATIONS Supply: 12 TO 24 Volts AC/DC Load: 1.5VA Ambient Temperature: (Electronics) -20 F to +160 F (-30 C to +70 C) Sensitivity: 1 picofarad Enclosure: Type 4X, 5, 12 Relay Output: DPDT contacts; 5 Amps 250 VAC Fail-Safe: Calibration: Status Indicator: Switch selectable "High" or "Low" level modes Set when probe is uncovered: COARSE adjust; single turn potentiometer FINE adjust; single turn potentiometer Internal LED indicates material in contact with probe. Time Delay: Probe Shield: Conduit Entry: Adjustable from 1 to 15 seconds Automatically compensates for material buildupon the probe 3/4" NPT 3

1.0 INTRODUCTION The Bin-Master PRO REMOTE 25 LV is a two piece point level control used to detect the presence or absence of liquids or granular solids. The PRO REMOTE 25 LV operates on the capacitance principle and incorporates a "Quick Set" feature to simplify calibration. The PRO REMOTE 25 LV includes switch selectable Fail-Safe output contacts and "Probe Shield" technology for ignoring material build-up. The PRO REMOTE 25 LV does not use RF and therefore does not interfere with nor is susceptible to interference from other devices. Upon installation the PRO REMOTE 25 LV is set up with the probe uncovered. The "Quick Set" feature allows simple setup and calibration of the unit to achieve low, medium, or high sensitivity settings. The PRO REMOTE 25 LV has an adjustable time delay of relay output for covered or uncovered conditions. 2.0 APPLICATIONS 2.1 The PRO REMOTE 25 LV electronics can be powered from a low voltage AC or DC supply. The supply voltage must be between 12 to 24 volts. 2.2 For applications in pressurized vessels up to 1500 PSI, the PRO REMOTE 25 LV should be mounted with the 3/4" stainless steel coupling. 2.3 Application temperatures for the various probes are: 1. Delrin Sleeved Stainless Steel:...250 Deg. F 2. Teflon Sleeved Stainless Steel:...500 Deg. F 3. Flush Mount (Polyethylene):...180 Deg. F 4. Flush Mount (Teflon):...450 Deg. F 3.0 INSTALLATION 3.1 Location and Mounting The PRO REMOTE PROBE HEAD is designed to mount utilizing either a standard 1-1/4" NPT coupling or optional 3/4" NPT coupling. When the PROBE HEAD is used with the flush mount probe, the flush mount probe mounts directly to the vessel wall using a 7" diameter bolt circle. Refer to Figures 1.1 through 1.4 for illustrations on installation, mounting options, and different probe combinations. The PROBE HEAD should be mounted in a position such that the probe itself is not in the direct flow of material. The vessel on which the PRO REMOTE PROBE HEAD is mounted must be made of metal which acts as part of the capacitive environment. If the vessel is not metal, a suitable metal plate must be installed with the Remote Probe Head. 4

3.2 Input Power and Field Wiring The PRO REMOTE 25 LV is available to operate from a low voltage AC or DC supply. The input voltage must be between 12 to 24 volts. The polarity of the supply voltage does not matter. Field wiring should conform to all national and local electrical codes and any other agency or authority having jurisdiction over the installation.. Vin G 1NC 1C 1NO 2NO 2C 2NC ASS'Y 530-0153 PCB 353-0055 12 to 24 AC/DC Ground Ground wire to ground screw or to G terminal on PCB Relay contacts are shown when the relay is de-energized. This is the FAIL SAFE condition. This would indicate a covered condition when the FAIL SAFE switch is in the HIGH position, or an uncovered condition when the FAIL SAFE switch is in the LOW position. 3.3 Wiring between Probe Head and Electronic Console The remote probe is connected to the electronics with a triaxial cable at least 10 feet but not more than 25 feet long. Beldon number 8232 or Alpha number 9850 cable is recommended. The electronics end of the cable is prepared at the factory and should be connected as shown in Figure 1.5 on page 13. The Brown wire connects to the Center Wire terminal, The Blue wire connects to the Inner Shld terminal, and the Green wire connects to the Outer Shld terminal. The probe head end of the cable should be prepared as shown below. Connect each shield and the center conductor to the appropriate terminal as shown in Figure 1.5. Be sure that there are no loose strands that could short to another terminal or conductor. NOTE: Place the cable strain relief nut and rubber grommet on the triax cable before preparing the ends of the cable. Strip the outer jacket off 1 3/4 inches away from the end of the cable. Unbraid the strands of the outer shield and then twist them together. Strip the inner teflon jacket off 1 1/2 inches away from the end of the cable. Unbraid the strands of the inner shield and them twist them together. Cut both shields so that they are 3/4 inch long. Strip 1/2 inch of the insulation off of the inner conductor. Each shield and the center conductor should be spaced 3/8 inch apart as shown. Strip Length Conductor Spacing 1/2" 1.1/4" 3/8" 3/8" 1/2" 3/4" 5

4.0 FAIL-SAFE SELECTION 4.1 Description A Fail-Safe condition means that the relay contact positions are set up so that in the event of a power failure, the relay will be de-energized and the contacts will indicate a condition that is deemed safe for the application. (Refer to FIGURE 2.1 for the location of the Fail-Safe selection switch.) 4.2 Fail-Safe High Fail-Safe High means that the relay will be energized when the probe is uncovered and will de-energize when the probe is covered. In this mode, a power failure will cause the relay contacts to indicate that the probe is covered whether it is or not. FAIL SAFE "HIGH" RELAY CONTACT POSITION UNCOVERED COVERED 1 1 1 2 2 2 NC C NO NO C NC 1 1 1 2 2 2 NC C NO NO C NC 4.3 Fail-Safe Low Fail-Safe Low means that the relay will be de-energized when the probe is uncovered and will energize when the probe is covered. In this mode, a power failure will cause the relay contacts to indicate that the probe is uncovered whether it is or not. FAIL SAFE "LOW" RELAY CONTACT POSITION UNCOVERED COVERED 1 1 1 2 2 2 NC C NO NO C NC 1 1 1 2 2 2 NC C NO NO C NC 6

5.0 CALIBRATION The PRO REMOTE 25 LV Quick Set calibration feature uses two single turn potentiometers making calibration very simple. One potentiometer labeled COARSE is used to compensate for the capacitance of the empty vessel. The other potentiometer labeled FINE is used to set in the desired sensitivity. Refer to FIGURE 2.1 for the location of these potentiometers on the printed circuit board. NOTE:The COARSE and FINE potentiometers are delicate electronic components. Do not use excessive force when adjusting them. NOTE: Accurate calibration requires that the appropriate probe be attached to the PRO REMOTE PROBE HEAD and the unit installed in the vessel. The probe must be UNCOVERED and material well below it. 5.1 Calibration Verification Following calibration adjustment, the sensitivity setting that you have selected should be checked by verifying that the PRO REMOTE 25 LV senses a covered probe condition with your material. 5.2 Calibration Procedure NOTE:Do not use excessive force when adjusting the COARSE and FINE potentiometers. 1. Turn both the COARSE and FINE potentiometers fully counter clockwise (CCW). The internal COVERED indicator light should be OFF. 2. Turn the COARSE potentiometer slowly clockwise (CW) to the point where the COVERED indicator light just turns ON and stays on. 3. Turn the FINE potentiometer slowly clockwise (CW) until the COVERED indicator light just turns OFF. ( If the COARSE potentiometer has been carefully adjusted, this should occur when the FINE potentiometer is between the 8 and 11 O'clock position.) Now continue to turn the FINE potentiometer clockwise (CW) to the desired sensitivity setting. HIGH sensitivity: 1/16 turn MEDIUM sensitivity: 1/8 turn LOW sensitivity: 1/4 to 1/2 turn 5.3 Sensitivity Selection Sensitivity Setting ( typical ) Dielectric Constant of Material HIGH sensitivity: 4 or less MEDIUM sensitivity: 4 to 10 LOW sensitivity: 10 or higher 7

6.0 TIME DELAY The PRO REMOTE has an adjustable time delay up to 15 seconds. This is a time delay for the output to change states from an uncovered to a covered condition and from a covered to an uncovered condition. This time delay affects the DPDT relay contacts. The internal LED (DS1) will immediately respond to a change in covered or uncovered condition regardless of the time delay setting. Minimum time delay is when the DELAY potentiometer is set fully counter-clockwise. (Refer to FIGURE 2.1 for the location of the DELAY potentiometer.) Maximum time delay is with the DELAY potentiometer set fully clockwise. NOTE:Do not use excessive force when adjusting the DELAY potentiometer. 7.0 WARRANTY AND CUSTOMER SERVICE 7.1 Limited Warranty The manufacturer warrants this equipment for two (2) years according to the following terms: 1.) This warranty extends to the original purchaser only and commences on the date of original purchase. The original purchaser must mail to the manufacturer the "Warranty Registration" card to confirm the equipment purchase. Failure to do so may void the warranty. 2.) The manufacturer will repair or replace any part of this equipment found to be defective, provided such part is delivered prepaid, to the factory. Manufacturer's obligation is limited to the cost of material and labor to repair or replace and does not include transportation expenses. 3.) This warranty shall not apply to any product which has, in our judgment, been tampered with, altered, subject to misuse, neglect or accident. In addition, the warranty does not extend to repairs made necessary by normal wear. 4.) This warranty is in lieu of all other warranties, expressed or implied. 7.2 Customer Service Bin Master offers a toll-free Customer Service phone number 1-800-278-4241. You may call the Customer Service Department for technical and application assistance Monday through Friday from 8:00AM to 5:00PM Central Time. International customers call us at (402) 434-9102 or reach us via fax at (402) 434-9133. 8

9270061.dgn 927a061.tif Mounting Plate Vessel Wall Standard Mounting Plate Vessel Wall Explosion Proof High Pressure Coupling Figure 1.1 3.00 Dia..281 Dia. (6) Holes Equally Spaced On a 7.00 Bolt Circle Mounting Hole Pattern In Vessel Wall 3/4 NPT Thread Mounting Hole In Vessel Wall 9

9270061.dgn 927b061.tif Gasket Vessel 5.75 Dia. Flush Probe.281 Dia. (6) Holes Equally Spaced On a 7.00 Bolt Circle Protective Cover Flush Mount Bin Wall Adaptor (optional) Mounting Hole Pattern In Vessel Wall Flush Mount Probe Figure 1.2 10

Coupling Explosion Proof 175-0070 Shielded, Delrin Sleeved 5/8 Dia. x 10.00 Long 530-0197 Shielded, Teflon Sleeved 530-0214 FlushMount Probe Standard...530-0082 High Temperature...530- PRO X Probe Combinations Figure 1.3 Quick Clamp 1.00 NPS Food Grade Coupling Used with 5/8 Delrin Probe Coupling 1.00 NPS to 3/4-14 NPT Used with 5/8 Delrin Probe 175-0083 Coupling 1.00 NPS to 1 1/4-11 1/2 NPT Used with 5/8 Delrin Probe 175-0082 Coupling 1.00 NPS to 3/4-14 NPT Used with 5/8 Teflon Probe 175-0097 Quick Clamp 1.00 NPS Food Grade Coupling Used with 5/8 Teflon Probe Coupling 1.00 NPS to 1 1/4-11 1/2 NPT Used with 5/8 Teflon Probe 175-0099

Vertical Mount 18" 457 MM Minimum 30 Deg. Mount Horizontal Flush Mount Horizontal Mount Flush Mount Bin Wall Adaptor May Be Required Mounting Options 9270061.dgn 927c061.tif Figure 1.4

AC AC P CENTER CONDUCTOR INNER SHIELD G OUTER SHIELD NOTE: PREPARE EACH SHIELD CONDUCTOR BY UNBRAIDING THE STRANDS THEN TWIST THEM TOGETHER. CONNECT THEM TO THE APPROPRIATE TERMINAL AS SHOWN. BE SURE THERE ARE NO LOOSE STRANDS THAT COULD SHORT TO ANOTHER TERMINAL OR CONDUCTOR. R1 SA1 R25 GREEN D9 R28 OUTER D10 SHLD CENTER C13 R8 WIRE INNER BROWN TB4 R8 R27 R10 R9 R2 D8 SHLD BLUE C5 C4 R7 C12 D7 U4 R24 C14 C16 Factory prepared solder connection R6 R4 R5 R3 R26 C15 U2 C9 D6 U5 C11 C2 U1 VKC03-24S05 D5 ++ C7 C10 COARSE FINE DELAY + R20 + C7 D2 Q3 Q1 C8 RV1 R11 R13 R12 D1 D4 R15 C6 R19 Q2 DS1 RV3 R21 D3 R22 R17 R22 RV2 R16 S1 R23 C3 U3 R18 + C6 H L FAIL SAFE + C1 K1 - DB1 + Q4 D11 TB3 TB1 TB2 PTC Vin 12 to 24 AC/DC G 1NC 1C 1NO ASS'Y 530-0153 PCB 353-0055 2NO 2C 2NC Figure 1.5 13

COARSE CALIBRATION ADJUSTMENT FINE CALIBRATION ADJUSTMENT R1 SA1 R25 T1 R28 GREEN D9 D10 OUTER SHLD CENTER WIRE BROWN C13 TB4 INNER SHLD R2 C13 D8 R8 R9 R27 R10 BLUE C5 C4 R7 C12 D7 U4 R24 C14 C16 R6 R4 R5 R3 R26 C15 C9 D6 U5 C11 C2 U1 U2 VKC03-24S05 D5 U5 D2 R14 C10 ++ R20 COARSE FINE RV1 R11 R13 R12 DELAY Q3 + C7 Q1 C8 R15 C6 R19 D1 Q2 D4 D3 DS1 RV3 R21 RV2 R16 C3 R18 U3 R17 R22 + C6 H L FAIL SAFE S1 R23 PROBE COVERED INDICATOR OUTPUT DELAY ADJUSTMENT FAIL SAFE SWITCH + C1 K1 Q4 - D11 DB1 + AC AC TB3 TB1 TB2 PTC Vin G 12 to 24 AC/DC ASS'Y 530-0146 1NC 1C 1NO ASS'Y 530-0153 PCB 353-0055 2NO 2C 2NC Figure 2.1 14

Mounting Instructions Always Mount Unit with Conduit Opening Down CONDUIT SEAL When installing this level indicator in environments where it is possible for moisture or moist air to enter the enclosure thru the electrical conduit, the conduit opening should be sealed with a duct seal compound or putty appropriate for the purpose. Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Email : hvssystem@hvssystem.com Site web : www.hvssystem.com