QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Similar documents
SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

DATA CENTER SOLUTIONS

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

G300LG. Industrial Gaseous Generator Set. G300LG 300kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

MG300. Industrial Gaseous Generator Set. MG kW. primary codes and standards. Standby Power Rating 375kVA 300kW 60 Hz PARALLELING UNIT

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RHINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

MD300. Industrial Diesel Generator Set. 300 kw Diesel. primary codes and standards. Standby Power Rating 375kVA 300kW 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES AND TANKS EPA TIER COMPLIANT

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

MD400. Industrial Diesel Generator Set. 400 kw Diesel. primary codes and standards. Standby Power Rating 500kVA 400kW 60Hz PARALLELING UNIT

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

GENERAC GUARDIAN SERIES STANDBY GENERATORS

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

1P 120/240V, 3600 RPM,

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

G150LG6. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG6 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

INDUSTRIAL DIESEL GENER ATOR SE T CODES AND STANDARDS POWERING AHEAD. STANDBY POWER RATING 400 kw, 500 kva, 60 Hz

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MG L 130 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET. Codes and Standards. Powering Ahead. Standby Power Rating 130 kw, 163 kva, 60 Hz

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SG L 130kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw. Standby Power Rating 1000 kw 1250 kva 60 Hz

MD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. MD kw

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

SG L 300kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

Siemens Liquid Cooled Standby Generators

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

MG L 150kW POWERING AHEAD. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

SG L 200kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

MG L 750kW. CODES AND STANDARDS Not all codes and standards apply to all configurations. Contact factory for details.

Siemens Liquid Cooled Standby Generators

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Diesel generator set QSK23 series engine

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Diesel generator set QSX15 series engine

60 Hz FEATURES. Exclusively from your Caterpillar dealer

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Spark-ignited generator set

22 / 27 / 32 / 38 / 48 kw

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Spark-ignited generator set

Transcription:

STANDBY POWER RATING 25 kw, 31 kva, 60 z Image used for illustration purposes only Features Generator Set Benefits PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY PRODUCT RINOCOAT PAINT SYSTEM IMPROVES RESISTANCE TO ELEMENTS Engine EPA COMPLIANT ENVIRONMENTALLY FRIENDLY INDUSTRIAL TESTED, GENERAC APPROVED ENSURES INDUSTRIAL STANDARDS POWER-MATCED OUTPUT ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE IMPROVES LONGEVITY AND RELIABILITY Alternator TWO-TIRDS PITC ELIMINATES ARMFUL 3RD ARMONIC LAYER WOUND ROTOR & STATOR IMPROVES COOLING CLASS MATERIALS EAT TOLERANT DESIGN DIGITAL 3-PASE VOLTAGE CONTROL FAST AND ACCURATE RESPONSE Controls ENCAPSULATED BOARD W/ SEALED ARNESS EASY, AFFORDABLE REPLACEMENT 4-20mA VOLTAGE-TO-CURRENT SENSORS NOISE RESISTANT 24/7 MONITORING SURFACE-MOUNT TECNOLOGY PROVIDES VIBRATION RESISTANCE ADVANCED DIAGNOSTICS & COMMUNICATIONS ARDENED RELIABILITY 1 OF 5

APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Make EPA Emissions Compliance EPA Emissions Engine Reference Cylinder # 4 Type Number of Main Bearings 5 Connecting Rods Cylinder Liners Ignition Generac Stationary Emergency See Emissions Data Sheet In-line Displacement - L (cu In) 2.4 Bore - mm (in) 86.61 (3.41) Stroke - mm (in) 100.08 (3.94) Compression Ratio 9.5:1 Intake Air Method Cylinder ead Piston Type Crankshaft Type Lifter Type Intake Valve Material Exhaust Valve Material ardened Valve Seats Engine Governing Governor Frequency Regulation (Steady State) Nuturally Aspirated Forged Aluminum No igh Energy Aluminum Alloy Cast Overhead Cam Steel Alloy ardened Steel yes Electronic +/- 0.25% *Fuel pressure must remain within specified range and not drop more than 1 in. w.c from static (no-load) to full load. Lubrication System Oil Pump Type Oil Filter Type Cooling System Cooling System Type Water Pump Flow -gal/min 11 Fan Type Pressurized Closed Pusher Fan Speed (rpm) 2150 Fan Diameter mm (in) 457 (18) Coolant eater Wattage 1500 Coolant eater Standard Voltage 120 VAC Fuel System Fuel Type Carburetor Secondary Fuel Regulator Fuel Shut Off Solenoid Natural Gas, Propane Vapor Down Draft Standard Standard Operating Fuel Pressure (Standard) 5-14 2 O* Engine Electrical System System Voltage Battery Charging Alternator (Amps) 30 Battery Size Battery Voltage Ground Polarity Gear Crankcase Capacity - L (qts) 3.8 (4) Full-Flow sping-on Cartridge 12 VDC See Battery Index 0161970SBY 12 VDC Negative ALTERNATOR SPECIFICATIONS Standard Model 390mm Poles 4 Field Type Revolving Insulation Class - Rotor Insulation Class - Stator Total armonic Distortion <5% Telephone Interference Factor (TIF) <50 Standard Excitation Brush Type Bearings Sealed Ball Coupling Flexible Disc Load Capacity - 100% Prototype Short Circuit Test Yes Voltage Regulator Type Full Digital Number of Sensed Phases 3 Regulation Accuracy (Steady State) ±0.25% CODES AND STANDARDS COMPLIANCE (WERE APPLICABLE) NFPA 99 BS5514 NFPA 110 SAE J1349 ISO 8528-5 DIN6271 ISO 1708A.5 IEEE C62.41 TESTING ISO 3046 NEMA ICS 1 UL2200 Rating Definitions: Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) 2 OF 5

OPERATING DATA POWER RATINGS Natural Gas Propane Vapor Single-Phase 120/240 VAC @1.0pf Three-Phase 120/208 VAC @0.8pf Three-Phase 120/240 VAC @0.8pf Three-Phase 277/480 VAC @0.8pf 104 75 38 104 75 38 STARTING CAPABILITIES (skva) skva vs. Voltage Dip 480 VAC 208/240 VAC Alternator kw 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 25 16 25 33 41 49 57 12 19 25 31 37 43 FUEL CONSUMPTION RATES* Percent Load 25% 50% 75% 100% Natural Gas ft 3 /hr 140 220 300 380 m 3 /hr 3.9 6.2 8.5 10.8 Percent Load 25% 50% 75% 100% Propane Vapor ft 3 /hr 56 119 151 m 3 /hr 1.6 2.5 3.4 4.3 * Fuel supply installation must accommodate fuel consumption rates at 100% load. COOLING Air Flow (inlet air combustion and radiator) System Coolant Capacity eat Rejection to Coolant Max. Operating Ambient Temperature Max. Ambient Temperature Maximum Radiator Backpressure ft 3 /min(m 3 /min) gal (Liters) BTU/hr ºF (ºC) ºF (ºC) in 2 O 1500 (42.48) 2.5 (9.46) 95,000 122 (50) 104 (40) 0.5 COMBUSTION AIR REQUIREMENT Flow at Rated Power cfm (m 3 /min) 70 ENGINE EXAUST Rated Engine Speed rpm 1800 orsepower at Rated kw** hp 40 Piston Speed ft/min BMEP psi ** Refer to Emissions Data Sheet for maximum bp for EPA and SCAQMD permitting purposes. 1182 120 Exhaust Flow (Rated Output) cfm (m 3 /min) 220 (6.2) Max. Backpressure (Post Turbo) ing (Kpa) 1.5 (5.1) Exhaust Temp (Rated Output - post silencer) ºF (ºC) 975 (524) Exhaust Outlet Size (Open Set) mm (in) 63.5 (2.5) Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. 3 OF 5

STANDARD FEATURES AND OPTIONS GENERATOR SET Genset Vibration Isolation Std Extended warranty Opt Gen-Link Communications Software Opt Steel Enclosure Opt Aluminum Enclosure Opt ENGINE SYSTEM General Oil Drain Extension Std Critical Exhaust Silencer Std Air cleaner Std Fan guard Std Radiator duct adapter Std Fuel System Fuel lockoff solenoid Std Secondary Fuel Regulator Std Flexible fuel lines Std Cooling System 120VAC Coolant eater Std Closed Coolant Recovery System Std UV/Ozone resistant hoses Std Factory-Installed Radiator Std Radiator Drain Extension Std Engine Electrical System Battery charging alternator Std Battery cables Std Battery tray Std Solenoid activated starter motor Std 10A UL float/equalize battery charger Std Rubber-booted engine electrical connections Std ALTERNATOR SYSTEM UL2200 GENprotect Std Main Line Circuit Breaker Std CONTROL SYSTEM Control Panel Digital Control Panel - Dual 4x20 Display Std Programmable Crank Limiter Std 21-Light Remote Annunciator Opt Remote Relay Panel (8 or 16) Opt 7-Day Programmable Exerciser Std Special Applications Programmable PLC Std RS-232 Communications Std RS-485 Communications Std All-Phase Sensing DVR Std Full System Status Std Utility Monitoring (Req. -Transfer Switch) Std 2-Wire Start Compatible Std Power Output (kw) Std Power Factor Std Reactive Power Std All phase AC Voltage Std All phase Currents Std Oil Pressure Std Coolant Temperature Std Coolant Level Std Fuel Pressure Std Engine Speed Std Battery Voltage Std Frequency Std Isochronous Governor Control Std -40deg C - 70deg C Operation Std Waterproof Plug-In Connectors Std Audible Alarms and Shutdowns Std Not in Auto (Flashing Light) Std Auto/Off/Manual Switch Std E-Stop (Red Mushroom-Type) Std NFPA 110 Level I and II (Programmable) Std Remote Communication - RS232 Std Alarms (Programmable Tolerances, Pre-Alarms and Shutdowns) Low Fuel Pressure Std Oil Pressure (Pre-programmed Low Pressure Shutdown) Std Coolant Temperature (Pre-programmed igh Temp Shutdown) Std Coolant Level (Pre-programmed Low Level Shutdown) Std Engine Speed (Pre-programmed Overspeed Shutdown) Std Voltage (Pre-programmed Overvoltage Shutdown) Std Battery Voltage Std 4 OF 5

DIMENSIONS AND WEIGTS* W L OPEN SET (Includes Exhaust Flex) L x W x in (mm) 77 (1956) x 34 (864) x 43 (1092) Weight (lbs) 1163 dba* 83 W L LEVEL 1 ACOUSTIC ENCLOSURE L x W x in (mm) 77 (1956) x 34 (864) x 46 (1168) Weight (lbs) 1414 dba* 60 *All measurements are approximate and for estimation purposes only. Sound levels measured at 23ft (7m) under normal operation and do not account for ambient site conditions. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. P.O. Box 8 Waukesha, WI 531 P: (262) 544-4811 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No 0173110SBY Rev. F 10/23/15 5 OF 5