MPA Chassis for Multi-Probe Magnetic Transducers

Similar documents
Switching DC Power Supply

Model 1693, 1694 Switching DC Power Supply

Operations and Service Manual. X30208 Load Bank

V1606 3U RACK ENCLOSURE

Division Systems TM Baggage Scale System. Product Specifications

XS500 Load Bank. Read all instructions before using the load bank. Contents

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Installing Power Components

Triple Output Power Supply

B BASIC HEAT TREATMENT CONSOLE

Technical Information Manual

XS400 Load Bank. Read all instructions before using the load bank. Contents

point2point ACCESSORIES CASES

X100P Load Bank. Read all instructions before using the load bank. Contents

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Model 1672, 1673 Triple Output Power Supply

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

CONNECTORS & RECEPTACLES

Analog Condensate Monitor Instruction & Maintenance Manual

XL1000 Load Bank. Read all instructions before using the load bank. Contents

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

OPERATOR S MANUAL STUDPRO SERIES

Differential Pressure Sensors

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

PS24/AC Volt AC 16 Amp

Flex Tube. User guide

MX150L ASSEMBLY INSTRUCTIONS

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Model DS1000/DT20 System

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

MODEL ELC-12/40-CVM-D BATTERY CHARGER

ACCESSORIES FOR SZE2 CABINETS

R800-16PCPS DUAL REDUNDANT POWER SUPPLY FOR THE R RACK USER MANUAL

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Cooling Module. Instruction Manual

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Combined Ventilation Controller RVWS-T-224HA

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

Triple Output High Resolution Power Supply. User Manual

Robust-Aire Systems 1,2&3

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Versatile Power Entry Module with Small Footprint. PS non-filtered

Shelbourne header monitor kit Up to 2004

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Transfer Switch TS-50. Owner s Manual

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc

SAVE THESE INSTRUCTIONS

Basic Kiln Repair Seminar - Topics. Basic Kiln Repair Seminar - Kiln Components. Basic Kiln Repair Seminar - Available Power

FL-2R MOVING HEAD 120W

Transfer Switch GPTS 30

Idle Free Systems, Inc. Reference Guide System Component Information

Temperature Controlled Soldering Station

GENERAL <ELECTRICAL>

Differential Pressure Sensors

Units with pedestal and busbars on the short side (+H360, flat mounting)

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

1291BL Series Technical Specification Single Axis Position and Rate Table System

Digital display Pressure range ON/OFF output Linear output Model

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Recommended Practices for Installation for EC Directive 2014/30/EU Relating to EMC

MODEL ELC-12/60-D BATTERY CHARGER

BITZER Capacity Controller for CSH Compressors Temperature Sensor

EZTRIM - Data and Specifications 2019

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Installing the ONS M6 Shelf

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

VERAK EMC. 19 Stand Alone Cabinet with Radio Frequency Protection.

AirForce Ionizing Blow-off Gun. Model User s Manual

Electro-Mechanical Swing Operator. Table of Contents

TIME OF FLIGHT Components from:

TBX-1328 High-Accuracy Isothermal Terminal Block

Katharometer Power Supply Units

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

INSTRUCTION MANUAL cnode Mini MF 4000 m

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

If You Are Experiencing This, Click Thru:

SERVICE MANUAL (INTERNATIONAL)

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Operations and Service Manual. XE400D-SB Load Bank

PRODUCT INFORMATION BULLETIN

24V 3A EN54 Ancillary Power Supply

Steering Column. Steering Column Component Layout.

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

JANDS DD-8. Technical Manual. Version 1.0

EMERGENCY POWER SUPPLY VX-2000DS 301H VX-2000DS H VX-2000PF VX-200PS H VX-200PS ER POWER SUPPLY FRAME POWER SUPPLY UNIT INSTRUCTION MANUAL

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

6900-( )-( ) HIGH SPEED SANDWICH PRESS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

Quik-Spec Coordination Panelboard Specifications

Transcription:

DESCRIPTION: TYPICAL APPLICATIONS: The MPA chassis is utilized for multi-probe SENIS Magnetic Field-to-Voltage Transducer system with any of SENIS Hall Probes. Characterization and quality control of permanent magnets Development of magnet systems Mapping magnetic field Quality control and monitoring of magnet systems (generators, motors, etc.) Application in laboratories and in production lines, etc. Figure 1: 10-channels MPA chassis for Multi-Probe Magnetic Field Transducer System SYSTEM STRUCTURE: The multi-probe magnetic transducer system consists of: Signal Processing Electronics modules, with Power Supply Unit (PSU), and detachable 3-Axis Hall Probes (for Hall Probes selection, please see Hall Probes Sections at www.senis.ch) MPA chassis The Items (a) and (b) are assembled into the aluminum Card Frames and they are integrated into a common 84HP rack (height 3U) enclosure. Page 1/5

- 2 1 4 3 Figure 2: The FRONT panel view The Signal Processing Electronic modules: 1 2 On the lower part of each of ten Electronics Al-boxes there is a panel mounted DIN SFV81 8-pins MALE connector (to match the corresponding Hall Probe); On the upper side there is a panel mounted DIN KFV81 8-pins FEMALE connector (for the corrected analogue output signals X, Y and Z, as well as for the probe temperature signal). The default range of the real-time corrected differential voltage outputs is ±10V, which equals to linear ±2T measurement range. The Power Supply unit: 3 4 - REAR PANEL: Power switch controls power to the system (ON/OFF). LED indicator highlights when the system is ON, and otherwise. Figure 3: The REAR panel view 5 6 The AC power input (220-240V, 50Hz / 100-120V, 60Hz), and fuse assembly is the primary entry and control point for AC power to the unit. Fan (ventilator). 5 6 Page 2/5

HALL PROBES: Figure 4: Hall Probe connected to the multi-probe system The multi-probe system includes the standard SENIS Hall Probes, detachable to the Electronic modules, with DIN KV81 8-pins connectors. Each Probe is adjusted relative to the corresponding Electronic processing unit; therefore the Hall Probes are not interchangeable! Mechanical Specifications: Part The MPA Enclosure Signal Processing Electronics Modules Power Supply Unit (PSU) Description & Size: Case, 3U, 84HP Enclosure Material: Aluminum Cabinet Style: Desktop External Dimensions: Height: 132 mm Width: 447 mm Depth: 315 mm Card frame, 3U, 7HP (detachable from the MPA enclosure) Enclosure Material: Aluminum External Dimensions: Height: 129 mm Width: 35 mm Depth: 167 mm Card frame, 3U, 14HP (not detachable from the MPA enclosure) Enclosure Material: Aluminium External Dimensions: Height: 129 mm Width: 70 mm Depth: 167 mm Page 3/5

Connections: AC Power Input The Hall Probe connector The Analogue Output Signals connector REAR PANEL: A 3-conductor power inlet (with a proper line fuse) on the rear panel for the AC powering. The line cord connects to the power line jack. Line voltage is present across the outer two conductors, and the center conductor is a safety ground. The fuse holder is integrated into the mains. It contains two 5 x 20 mm T fuses. The interior fuse is the active one, and the exterior fuse is the spare one. The proper fuse values are: 0.25 Amps (T) for 220-240 Vac / 50Hz, 0.50 Amps (T) for 100-120 Vac / 60Hz powering system. The ON/OFF Switch that controls the power to the unit. The LED indicates the powering ON/OFF of the system. DIN SFV81 8-pins connector (MALE, panel mounted) (mating plug KV81) DIN KFV81 8-pins connector (FEMALE, panel mounted) (mating plug SV81): Field signal X+, X- Field signal Y+, Y- Field signal Z+, Z- Temperature signal Signal common GND Pins 1 and 6, respectively Pins 5 and 4, respectively Pins 3 and 7, respectively Pin 2 Pin 8 Power Requirements: Total System Weight: AC input, 220-240V/50Hz or 100-120V/60Hz; 40 VA max 11.5 kg (including the Hall Probes) Environmental Parameters: Operating Temperature Storage Temperature Electromagnetic Hall Probe: +5 C to +85 C Electronics: -20 C to +50 C -20 C to +85 C Compliant to standard norms Documentation available upon request INSTALLING THE MPA SYSTEM 1. CONNECTING THE HALL PROBE SENIS Hall probes are built to be as robust as possible for a small, precision device. However, it is most important that certain precautions be taken when handling and installing probes so that they are not damaged or destroyed, and to preserve their accurate calibration. Your multi-probe system may be used only with the SENIS Hall probes. Each Hall probe is in-factory calibrated relative to its Electronic module; therefore, the probes cannot be exchanged between the Electronics. In order to obtain specified performance, make sure that the each Hall probe (labeled with a corresponding Serial Number) is connected properly to its Electronics module (also labeled by the same Serial Number). Page 4/5

Mount the Probe head so that there is no pressure that will tend to bend or depress its ceramic rear surface. If the probe head is clamped, the user needs to make sure that the environment surface in contact with the reference plane of the probe is flat and covers as much of the probe reference surface as possible. Do not apply more force then required to hold the probe in its mounting. Any strain on the ceramic will alter the probe's calibration, and excessive force will destroy the Hall element inside. When the probe head is mounted, the cable should be clamped firmly nearby so it cannot be torn away from the probe head if accidentally pulled. The flexible section adjacent to the probe head can be carefully folded to allow the cable to come away in any direction, but avoid repeated flexing of this section. Keep the cable out of the way of foot traffic. Do not pinch the cable, or drop sharp or heavy objects on it. A severed cable cannot be re-joined without altering the probe's performance, and requires factory repair and re-calibration. The first ensure that the system is not powered. If so, carefully plug the Probe connector (female 8-pins DIN KFV81) to the corresponding male 8-pins DIN SV81 connector on the electronics front panel. Ensuring that its pins engage correctly, tighten the metal ring of the probe connector. Do not leave these loose as they form part of the shielding system around the transducer. Always disconnect power from the Signal conditioner before connecting or disconnecting the probe! 2. THE AC LINE INPUT CONNECTION The MPA chassis is equipped with a 3-conductor power line jack (with a proper line fuse) on the rear panel for the AC powering. Line voltage is present across the outer two conductors, and the center one is a safety ground. The safety ground attaches to the instrument chassis and protects the user in case of a component failure. The first check if the line voltage is properly selected. Ensure that there is no power. If so, check the outlet and the connection at both ends of the power cord. Next check the fuse. Remove line cord, and then place a small slotted screwdriver in the slot of the small door at the rear of the unit to access the fuse. For 100/120 V operation, the fuse rating is 0.5 A, and the fuse type is 5x20mm T. For 220/240 V operation, the fuse rating is 0.25 A, and the fuse type is 5x20 mm T. Test the fuse with ohmmeter. Do not rely only on visual inspection of the fuse. Always plug the power cord into a properly grounded receptacle to ensure safe operation of the instrument. The power switch is a part of the line input assembly on the front panel of the MCSC and turns line power to the instrument ON and OFF. When the switch is down, power is OFF. When the switch is up, power is ON. 3. ANALOG OUTPUTS The corrected analogue voltage signals of each Hall probe are available at the 8-pins DIN connector KFV81, mounted on the upper side on the front panel of the corresponding transducer. 4. GROUNDING and SHIELDING All the parts of the MPA chassis metal enclosure are connected together on a manner to form a compact electric shield around the electronics inside. When the probe connector is plugged into the MPA chassis and the connector s metal ring is properly tightened, the probe connector case and the MPA s case are connected together and form an integral shield around the circuitries inside. The cable shield is added to the case shield and extends protection from electrical interference almost up to the probe head. Because there is an internal connection between the electronics common (ground) and the probe connector case, when the probe connector is engaged the inside circuits common will be connected to the case. The shielding provided with the above arrangement should be sufficient protection against EMI in most cases. For electrical safety, the MPA chassis metal case is grounded through the third wire (safety ground) of the AC power input cord. Page 5/5