OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

Similar documents
OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

Commercial Products Catalog

G2 Optima Plus Flushometer

Geberit Flushing Technologies Electronic and Manual Flush Valves

AquaSense ZTR Series

AquaSense TM ZEG Series

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Installation Instructions

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Installation Instructions

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Installation Instructions

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

Maintenance Guide. OPTIMA Components:

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Sloan Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 6. SLIP JOINT GASKETS AND RINGS

Installation Instructions

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES

Installation Instructions

AquaSense ZTR Series

Installation Instructions

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

AquaSense ZTR Series

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Sloan & Zurn Flush Valves

AquaSense TM ZTS6200EV Series

AquaSense AV ZER Series

Installation Instructions

Installation Instructions

Optima Flushometers Current style Royal (after 09/26/10)

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

GENUINE REPAIR PARTS FOR

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

TABLE OF CONTENTS Flushometer Section

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Installation Instructions

A-Item List Price Sheet Pricing for GO BLUE Parts

ZP6800 Series. Concealed Flush Valves Installation, Operation, Maintenance and Parts Manual

AquaVantage AV ZER6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

AquaSense AV ZER Series

Section 3 FLUSHOMETER. Table of Contents. Phone Fax

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

ECOPOWER FLUSH VALVES

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Section 3 FLUSHOMETER. Table of Contents. Phone (650) Fax (650)

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Royal Flushometer PARTS LIST

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

AquaSense AV Closet ZEMS Series Automatic Systems Sensor-Operated AquaVantage Flushometer Installation, Operation, Maintenance, and Parts Manual

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Milano AUTOMATIC FAUCET

Sensor-Operated Exposed Systems ZEMS6200 ZEMS ZEMS ZEMS6201 ZEMS6203

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

AquaSense AV TM ZEMS Series

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

RetroFit Kits and Flush Valves. AquaSense Battery Powered Flush. Valves/Retrofit Kits. E-Z Flush RetroFit Kits And Valves

Installation Instructions

LIGATURE RESISTANT SENSOR FAUCET

SLOAN ZURN DELANY INLET SIZE FLUSH CONNECTION ROUGH-IN

AquaVantage Z6000AV Series

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

ETF-600 Sensor Operated Lavatory Faucet

Installation Instructions

S Plumbing Fixtures

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Convert Your Manual Flush Valves To Sensor-Operated Hands-Free Flushing With The Zurn E-Z Flush

ELECTRONIC FLUSH VALVE FOR URINALS jupiter 2040

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Installation For Service Only

LED Reference for Circuit Board

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Steward Waterless Urinals by Kohler

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Introduction. Installation. Maintenance. Bill of Materials

AquaSense ZEMS G2 Series

Aquaflush Z6000 Series

Optima ETF-600/ETF-610

Transcription:

ISO 9001 Certified OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC) www.hydrotekintl.com 5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807 Phone (800) 922-9883 Fax (866) 670-5580

ISO 9001 Certified 8000 Series U.S. Patent 6192530B1, 5699994 AC, Battery, or Solar Powered Sensor Operated Flush The Hydrotek 8000 Series Automatic Flush Valves are the most advanced, electronic flushing system in the industry today. By incorporating our fieldtested electronic circuitry and slow-closing solenoid valves, Hydrotek has developed an innovative non-diaphragm, piston flushing mechanism that will provide years of dependable and trouble-free service. The Hydrotek AUTOFLUSH system is completely automatic: there is no need to contact any surface, no handle to push, and it flushes only when it is used. It provides the ultimate sanitary protection, the convenience of cleaner restroom facilities, and the most efficient system in water conservation. ADA Compliant. Meets all barrier free codes Conserves water and energy Easily installed in new or retrofit applications Competitively priced for today s commercial market Promotes cleanliness & hygiene Proven Hydrotek craftsmanship and reliability H-8000C Series (AC) Complete Units HB-8000C Series (Battery) Complete Units HB8RFKC Series (Battery) Complete Units HB-8000SLE Series (Solar) Complete Units Features: ACCU-SENSE adjustable sensor eyes Standard manual mechanical override button for both urinals & water closets Standard brass/chrome-plated, all metal construction with other finishes available AC/DC powered - field switchable Preset/adjustable flow rate and sensor distance Self-diagnostic electronics Standard vandal resistant stop valve (complete units only) Superior piston flushing mechanism Field adjustable for left and right rough-in Battery replacement without water shut-off Operating pressures: 10-125 PSI Standard self-cleaning filtering system Switchable from/to urinal or closet 36 hour sentinel flush Superior VSI silicone elastomer seals, unaffected by chlorine, chloromines or ammonia AC with DC backup models automatically switch to batteries during a power outage Uses inexpensive AA batteries Battery service life: 400,000 on/off cycles (650,000 for the HB-8000SLE Series) Low battery indicator light (battery powered only) No outside power source required (battery powered only) Can be installed by one tradesperson (battery powered only)

H-8000C (AC Powered) Hydrotek Autoflush Valves 8000 Series Meets A.S.S.E. Standard 1037-89 HB-8000C (Battery Powered) The 8000 Series Flush Valves are available in: H-8000C Series (AC Powered): 9 H-8000C-A (Closet) 9 H-8000C-B1 (Urinal) 9 H-8000C-B2 (Urinal) *Water conservation, concealed and AC with DC backup models available* HB-8000C Series (Battery Powered): 9 HB-8000C-A (Closet) 9 HB-8000C-B1 (Urinal) 9 HB-8000C-B2 (Urinal) *Water conservation and concealed models available* HB-8000SLE Series (Solar Powered): 9 HB-8000SLE-A (Closet) 9 HB-8000SLE-B1 (Urinal) 9 HB-8000SLE-B2 (Urinal) *Water conservation and retrofit models available* HB8RFKC Series Retrofit Models (Battery Powered): Sloan & Zurn Retrofit 9 HB8RFKC-C (Closet) 9 HB8RFKC-U (Urinal) Delany Retrofit 9 HB8RFKC-CD (Closet) 9 HB8RFKC-UD (Urinal) *Water conservation models available* HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste 124 Orlando, FL 32807 800.922.9883 (Phone) 866.670.5580 (Fax) www.hydrotekintl.com PLUMBING SPECIFICATIONS: Model Fixture Supply Line Top Spud Flow Rate H/HB-8000C-A Closet 1 1-1/2 1.6 GPF H/HB-8-128 Closet 1 1-1/2 1.28 GPF H/HB-8000C-B1 Urinal 3/4 3/4 1.0 GPF H/HB-8000C-B2 Urinal 1 1-1/4 1.0 GPF HB8RFKC-C/U Cl. & Ur. N/A N/A 0.5-3.5 GPF ELECTRICAL REQUIREMENTS: AC Powered Units: Solenoid valve and sensor: 6V DC Transformer: Input 120V AC, 60 Hz Output 12V DC Battery Powered Units Solenoid valve and sensor: 6V DC Battery: (4) AA Alkaline Batteries Battery Service Life: 400,000 flushes, up to 6 years (Battery) 650,000 flushes, up to 10 years (Solar) BASIC PACKAGE INCLUDES: H-8000C (-A, -B1, -B2) HB-8000C (-A, -B1, -B 2) HB8RFKC (-C, -U) HB-8000SLE (-A, -B1, -B2) (1) Flush Valve 9 9 9 9 (1) Stop Valve 9 9 9 (1) Sweat Kit 9 9 9 (1) Flush Tube 9 9 9 (1) Spud Coupling 9 9 9 (1) Vacuum Breaker 9 9 9 (1) AC Adapter 9 (1) AC Input Tube 9 (4) AA Battiers 9 9 9 OPTIONAL ACCESSORIES: HC-010 Multi-Unit Power Adapter (AC only) - 8 units HC-0104 Multi-Unit Power Adapter (AC only) - 4 units

ISO 9001 Certified HB-8000C HB-8000C Solar Powered Flush Valve with Battery Backup Installation Instructions Battery Powered Flush Valve Installation Instructions 1 2 3 4 Installation Instructions: 1. Prior to installation, DRY TEST the unit for proper operations. Loosen the Set Screws (1) using the allen wrench provided and remove the Top Cap (2) from the valve body by pulling it straight up. 2. Properly insert 4 AA batteries into the Battery Holders (3). Push the RESET button and watch the indicator lights on the Control Module (4) for the following pattern: Red, (click), Green, Red, Red. This indicates that the electronics are functioning properly. If the indicator lights do not blink, contact the factory or your local Hydrotek representative. 5 3. Reinstall the Top Cap (2) onto the valve body and tighten the Set Screws (1). Install the Stop Valve (5) to the supply line using a Hydrotek Sweat Kit (optional). 4. Connect the valve body to the Stop Valve (5) using the Slip Joint Nut (6). 5. Attach the Vacuum Breaker (7) and Tailpiece (9) to the valve body using the Lock Nut (8). Secure the Tailpiece (9) to the plumbing fixture using the provided Spud Coupling (10). 6 6. Turn the water on through the Stop Valve (5) and check for leaks. Push and hold the Override Button (11) for 30 seconds and check the fixture for overflow. Adjust the water flow from the Stop Valve (5) for a smoother flush. 7 8 9 11 7. TEST: Stand in front of the flush valve for 4 seconds, then step away. The valve should flush automatically. If not, refer to the Troubleshooting Guide. 8. Flow rates are preadjusted from the factory. If minor adjustments are needed, contact Hydrotek for further details. 10 Parts: 1. Set Screws 7. Vacuum Breaker 2. Top Cap 8. Lock Nut 3. Battery Holder (2) 9. Tailpiece 4. Control Module 10. Spud Coupling 5. Angle Stop 11. Override Button 6. Slip Joint Nut HYDROTEK INTERNATIONAL, INC. 5055 Forsyth Commerce Rd., Ste 124 Orlando, FL 32807 800.922.9883 (Phone) 866.670.5580 (Fax) www.hydrotekintl.com

HB-8000C Series Sensor Operated Flush Valve Troubleshooting Guide Normal Operation: When power is connected, the flush valve will immediately perform diagnostic function. You will hear a clicking sound and see lights flash. When the sensor is activated, the light will flash once and the valve will flush. The red indicator light will flash when the batteries are low. Problem Possible Cause To Diagnose Remedy Water not turned on Check water supply Turn water on Valve will not turn on: Valve will not shut off: Power supply failure No light, no clicking: Check batteries Check power adapter Reinstall or replace batteries/ Replace power adapter Low battery Light continues to flash Replace batteries Electronic PCB / Sensor is defective Solenoid valve is clogged Solenoid coil is defective No light, no clicking: Reinsert batteries Reattach power adapter Solenoid is clicking but no water is coming out Insert new batteries or reattach power adapter. Light blinks but no solenoid is clicking Replace electronic PCB Clean solenoid Replace solenoid coil The solenoid valve is normally closed. Turn off water and activate the valve. If there is a clicking sound, the solenoid valve is dirty. If there is no clicking sound, then check the solenoid valve. If water is leaking through, the solenoid valve is dirty and needs to be serviced. Other factors include: Sensor distance is too long Control module is defective Manual override button is sticking IMPORTANT: Periodic maintenance is required for smooth and trouble-free operation of this flush valve. For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922-9883.

HB-8000C Series Sensor Operated Flush Valve Assembly Parts No Description Part Number 1 Battery Holders (2 required) HCC-104A 2 Control Module HCC-080B 3 Solenoid Coil HCC-098 1 4 Sensor Eye and Cable HCC-080E 2 5 Sweat Kit Assembly 6 Angle Stop - Complete Assembly HC-084 (3/4 ) HC-084B (1 ) HC-082A (3/4 ) HC-082B (1 ) 7 Angle Stop Repair Kit HC-082C 8 Control Disc Assembly HCC-102 9 Manual Override Button Assembly HC-089 10 Vacuum Breaker Repair Kit HC-086 R 3 4 5 11 Flush Tube 12 Top Spud Assembly HC-086A (1-1/2 ) HC-086B (3/4 ) HC-086C (1-1/4 ) HC-093A (3/4 ) HC-093B (1-1/4 ) HC-093C (1-1/2 ) 6 R Solenoid Valve Repair Kit HCC-106 Please visit our website, www.hydrotekintl.com, for our most current Products Pricing Sheet. 8 7 10 9 12 11

HB-8000C Series Sensor Operated Flush Valve Control Module 1 2 3 4 9 8 7 6 5 1. DC Input Pin Receptor 2. Dip Switches 3. Reset Button 4. Indicator Lights 5. Solenoid Pin Receptor LEGEND 6. Control Cable (Sensor Eye) Pin Receptor 7. Sensor Distance Adjustment Dial 8. AC Input Pin Receptor 9. DC Input Pin Receptor

HB-8000C Series Sensor Operated Flush Valve Control Module Settings Flow rate and sensor arming time can be adjusted via the dip switches located on the Control Module. Urinal Closet Flushing Volume Gallons Per Flush Sw 1 Sw 2 Sw 3 Sw 4 0.5 ON ON ON ON 1.0 ON ON ON OFF 1.28 ON ON OFF ON 1.6 ON ON OFF OFF 2.0 ON OFF ON ON 2.5 ON OFF ON OFF 3.0 ON OFF OFF ON 3.5 ON OFF OFF OFF Flush Valves are preset to 1.0 GPF for urinal and 1.6 GPF for closet Sensor Arming Time Sensing Time Required to Flush Urinal Sw 5 Sw 6 Sw 7 Sw 8 Arming Time Standard OFF OFF OFF ON 3 seconds Optional ON OFF OFF OFF 1.5 seconds Closet Sw 5 Sw 6 Sw 7 Sw 8 Arming Time Standard ON OFF OFF OFF 4 seconds Optional OFF OFF OFF OFF 8 seconds NOTE: PUSH THE RESET BUTTON ON THE CONTROL MODULE AFTER ANY ADJUSTMENTS TO THE DIP SWITCHES. Sensor Distance Adjustment Clockwise Increase sensing distance Counter-Clockwise Decrease sensing distance