* * Rev. 9 01/18 Product Manual

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet 2760 DryLoc ph/orp Preamplifier

Signet 4150 Turbidimeter

Signet Conductivity/Resistivity Electrodes

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2760 DryLoc ph/orp Preamplifier

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet Conductivity/Resistivity Electrodes

Signet 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 2551 Magmeter Flow Sensor

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet ph/orp Transmitter

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Insertion/Submersion Flow Through Sensor

General Purpose ph/orp Sensors

NEW QUICK CABLE-TO-SENSOR RELEASE,

General Purpose ph/orp Sensors

Measurement and Instrumentation

TUpH Retraction/Submersion/Insertion ph/orp Sensors

ph/orp Sensor Model 399 ph/orp

Low Cost Submersion and In-Line ph Electrodes

Combination ph/redox (ORP) Sensors

Product Specifications

Combination ph/redox (ORP) Sensors

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

SIGNET 7002 Vortex Flow Sensor ENGLISH

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

* * Rev. F 03/16 Operating Instructions

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

SIGNET Vortex Flow Sensors ENGLISH

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Signet 7000/7001 Vortex Flow Sensors * *

Product Specifications

Signet 2517 Brass Paddlewheel Flow Sensor * *

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Automation Made Easy 2013 Signet Measurement and Control Product Catalog

OPERATING INSTRUCTION MANUAL

SIGNET Temperature Transmitter

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

8000 Series ph/orp Electrode Platform Product Instructions

MEASUREMENT AND INSTRUMENTATION FLS

Signet 2552 Metal Magmeter

Digital ph transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

Signet 2552 Metal Magmeter

Product Type Manufacturer Beginning Page Conductivity Liquid Level Controls ABB SSAC 12/2

Signet Pressure Transmitter

Accessories Guide ph/orp/conductivity Sensors

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Digital ph transmitter

Retractable ph/orp Sensors

Instrument Enclosure Assemblies

Low Cost Submersion and In-Line ph Electrodes

Analytical Instruments Two-Electrode Conductivity Sensors

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Model 7777DVP Immersion/In-Line Mounting for Durafet III ph Electrodes Installation and Maintenance Rev. 1 3/04

Signet Measurement and Instrumentation

Retractable ph/orp Sensors

Signet Temperature Transmitter

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Retractable ph/orp Sensors

* * Rev M 10/14 Operating Instructions

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

General Specifications

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Combination ph/orp Sensor

2100 Turbine Flow Sensor

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics

General Specifications

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

User s Guide Shop online at omega.com SM For latest product manuals: CDE-285X SERIES Conductivity Sensors

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Signet Measurement and Instrumentation

Liquid Conductivity Two & Four Electrode Sensors

Retractable ph/orp Sensors

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Control and automatic dosing

871PH Series ph, ORP, and Fluoride Sensors and Accessories

AST10 & AST51 Contacting Conductivity Sensors

Transcription:

Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½ to 4 in.) ¾ NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees DN15 to DN100 (½ to 4 in.) Special design allows for installation at any angle, even inverted or horizontal Ryton (PPS) body for broad range of chemical compatibility Patented DryLoc connector with gold plated contacts Quick temperature response The Signet 2724-2726 ph and ORP Electrodes features a patented reference electrode design and uses the unique foul-proof patented DryLoc connector. The large area PE reference junction and pathway is constructed to increase the total reference effectiveness and ensures long service life. The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensor electronics. The robust Ryton threaded sensor body and choice of flat ph, bulb ph, or flat ORP sensing elements provides broad range of chemical compatibility for a wide variety of applications. There are two optional ph sensing versions available, HF and LC. The HF version is for applications where traces of hydrofluoric acid (2% or less) will attack standard ph glass in levels of ph 6 and below. The LC version can be used for low conductivity fluids 20-100 μs/cm nominal and below 20 μs when mounted under controlled conditions. The quick temperature response is available in either a PT1000 or 3 KΩ temperature sensor and allows compatibility with all Signet ph/orp instruments. The 2724-2726 electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾ inch NPT or ISO 7/1-R 3/4 threads for installing into standard pipe-tees. They can also be mounted directly into Signet standard fittings, DN15 to DN100 (½ to 4 inch) HF resistant glass available for trace HF of <2% Low conductivity sensor available for liquids down to 20 μs/cm Applications Water & Wastewater Treatment Neutralization Systems Effluent Monitoring Sanitization Systems Pool & Spa Control Aquatic Animal Life Support Systems Process Control Cooling Towers *U.S. Patent Nos.: 6,666,701, 7,799,193 B2 and 7,867,371 B2

Specifications General Performance Efficiency >97% @ 25 C (77 F) Operating Range ph 0 to 14 ph ORP ±2000 mv 3-2726-LC Low conductivity fluids; 20-100 μs/cm nominal <20 μs; flow must be less than 150 ml/min in a properly grounded system 3-2726-HF Hydrofluoric acid resistant glass, ph 6 or below; trace HF <2% Compatibility 2750 Electronics, 2760 Preamplifier Temperature Sensor PT1000 versions compatible with Signet 2750 ph/orp Sensor electronics for connection to a PLC or to the Signet 8900 or 9900 instruments 3 KΩ Balco versions compatible with the Signet 2760 ph/orp preamplifier for connection to the Signet 5700 ph/orp Monitor and the Signet 8750 ph/orp Transmitter Process Connection ¾ in. NPT ISO 7/1-R 3/4 Mounts into Signet fittings Wetted Materials ph Ryton (PPS), glass, UHMW PE, FPM ORP Ryton (PPS), glass, UHMW PE, FPM, Platinum Max. Temperature/Pressure Rating Operating Temperature Range* -10 C to 85 C 14 F to 185 F Operating Pressure Range 6.8 bar @ -10 to 65 C (100 psi @ 14 to 150 F) 4 bar @ 65 to 85 C (58 psi @ 150 to 185 F) *Best performance for 2726-HF sensors is above 10 C (50 F) Recommended Storage Temperature The best storage temperature for the 272X ph and ORP electrodes is 0 C to 50 C (32 F to 122 F) The electrode glass will shatter if shipped or stored at temperature below 0 C (32 F) The performance life of the electrode will shorten if stored at temperatures above 50 C (122 F) Mounting In-line Mounting Use the sensor threads Use a Signet standard fitting up to 4 in. Sensor can be mounted at any angle Submersible Use threads on models 2750 or 2760 Mounting Requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded liquid tight extension conduit. Shipping Weight 0.25 kg 0.55 lb Standards and Approvals Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management See Temperature and Pressure graphs for more information www.gfsignet.com

6 7 8 RELAY 1 4 10 RELAY 2 ph 2 12 0 14 Signet Monitor Dimensions * 0.64 mm (0.25 in.) 109 mm (4.3 in.) Threads: ¾ in. NPT or ISO 7/1 R-3/4 0 Horizontal 44.45 mm (1.75 in.) 25.4 mm (1.0 in.) 53.34 mm (2.1 in.) 18.3 mm (0.72 in.) 9.3 mm (0.37 in.) * Mounting Angle Models 2724-2726 may be mounted at any angle without affecting the performance. *Avoid locations with air pockets and sediment. Panel Mount Signet Instruments 5700 8750 with 2760 Preamplifier 8900 9900 with 2750 Electronics Field Mount - Pipe, Tank, Wall Signet Instruments 8900 with 2750 Electronics 9900 with 2750 Electronics and 3-8050 Universal Mount kit 4 to 20 ma Input 3-2750 Sensor Electronics and customer supplied Chart Recorder or Programmable Logic Controller System Overview OR Signet 2724-2726 DryLoc ph/orp Electrodes In-Line Installation - Signet and threaded fittings only + + Submersible Installation - Customer supplied pipe extension or conduit with 3/4 in. NPT or ISO 7/1-R 3/4 threads* PLC All sold separately *Refer to the Signet Submersion brochure located in the K-Factors Fittings and More Kit (3-0000-709) for installation suggestions and options. www.signet.com

Electrode Key Features and Benefits: 4 1. Ryton body for chemical compatibility with most harsh chemicals. 2. Porous UHMW PE (ultra high molecular weight polyethylene) junction resists fouling and build-up. 3. Internal temperature sensor located in the glass stem for a quick temperature response. 4. DryLoc connector with corrosion resistant gold pins for quick and easy sensor removal. Resists moisture and dirt intrusion. 5. Dual-patented reference design with a 406 mm (16 inch) reference pathway enhances longer life. This enables the sensor to last significantly longer than other standard ph/ ORP electrodes in most applications. 5a. With the new patented reference design, the Signet 2726-LC version performs better in low conductivity water between 20-100 μs and lasts longer than previous DI electrodes. 5b. The 2726-LC sensor also performs in applications with extremely low (less than 20 μs) conductivity. Special precautions must be taken to avoid measurement complications. Please note the following. Electrostatic charges (streaming potentials) can cause dramatic offsets in a system with very low conductivity water. To minimize this, sensors should be placed in a well grounded system. To enhance performance, a low flow cell is recommended to provide a steady flow rate (150 ml/minute). Sensors placed in high flow applications will experience noisier readings due to streaming potential. 6. Threads for NPT or ISO process connection into reducing tees Use off-the-shelf GF reducing tees DN20 to DN100 (¾ to 4 in.). 7. Mounts directly into Signet fittings (½ in. 4 in.) for easy sensor retrofitting. 8. Mount submersed into a tank via the 2750 or 2760 back threads. 6 1 3 2 Sensor in threaded reducing tee 5 Dual-patented reference design for long life in conductivity or chemicals. 7 Sensor in Signet fitting 8 Sensor submersible installation www.gfsignet.com

Operating Temperature/Pressure Graph Note: The pressure/temperature graphs are specifically for the Signet sensor. During system design the specifications of all components must be considered. In the case of a metal piping system, a plastic sensor will reduce the system specification. (psi) 150 125 100 (bar) 10.3 8.6 6.9 75 5.2 50 3.4 25 1.7 C F 0-40 -20 0 20 40 60 80 100-40 -4 32 68 104 140 176 212 Application Tips Use the flat glass electrodes when a self-cleaning feature is desired; especially useful in applications with abrasive chemicals. Use bulb protected electrodes for general purpose applications ORP electrodes are generally used for chemical reaction monitoring, not control. Ensure that sensor materials are chemically compatible with the process liquid. Keep electrode tip wet, avoid air pockets and sediment. Model 2724-2726 Ordering Notes 1) ph and ORP electrodes require connection to model 2750 sensor electronics or 2760 preamplifier. 2) The 2750 EasyCal feature recognizes common ph and ORP buffer values of 4, 7 and 10 ph and + 87 and + 264 mv for ORP. Buffer Solutions The Signet ph buffers are ideal for calibration. The liquid solutions are conveniently packaged in one pint (473 ml) bottles. ph buffer kits in powder pillows are available for mixing fresh solutions with water at the time of use. All ph buffers are color coded for easy identification; 4.01 ph is red, 7.00 ph is yellow, and 10.00 ph is blue. All ph buffers are traceable to NIST standards. These buffer solutions can be used to calibrate ORP sensors when saturated with quinhydrone. www.signet.com

Ordering Information Mfr. Part No. Code Tip design Process Connection Thread Options ph Electrodes Temperature element PT1000; use with 2750 sensor electronics* 3-2724-00 159 001 545 Flat ¾ in. MNPT, Thread 3-2724-01 159 001 546 Flat ISO 7/1-R 3/4 Thread 3-2726-00 159 001 553 Bulb ¾ in. MNPT, Thread 3-2726-01 159 001 554 Bulb ISO 7/1-R 3/4 Thread 3-2726-HF-00 159 001 549 Bulb, HF resistant¹ ¾ in. MNPT, Thread 3-2726-HF-01 159 001 550 Bulb, HF resistant¹ ISO 7/1-R 3/4 Thread 3-2726-LC-00 159 001 557 Bulb, Low Conductivity² ¾ in. MNPT, Thread 3-2726-LC-01 159 001 558 Bulb, Low Conductivity² ISO 7/1-R 3/4 Thread Temperature element 3 KΩ Balco; use with 2760 preamplifier** 3-2724-10 159 001 547 Flat ¾ in. MNPT, Thread 3-2724-11 159 001 548 Flat ISO 7/1-R 3/4 Thread 3-2726-10 159 001 555 Bulb ¾ in. MNPT, Thread 3-2726-11 159 001 556 Bulb ISO 7/1-R 3/4 Thread 3-2726-HF-10 159 001 551 Bulb HF resistant 1 ¾ in. MNPT, Thread 3-2726-HF-11 159 001 552 Bulb HF resistant 1 ISO 7/1-R 3/4 Thread 3-2726-LC-10 159 001 559 Bulb, Low Conductivity 2 ¾ in. MNPT, Thread 3-2726-LC-11 159 001 560 Bulb, Low Conductivity 2 ISO 7/1-R 3/4 Thread ORP Electrodes; Compatible with both the 2750 sensor electronics and the 2760 preamplifier 3-2725-60 159 001 561 Flat ¾ in. MNPT, Thread 3-2725-61 159 001 562 Flat ISO 7/1-R 3/4 Thread *The 2750 sensor electronics has a digital (S 3 L) output which is used with 8900 or 9900 Instruments. It also has a 4 to 20 ma output for connections to PLC s, data recorders, etc. **The 2760 preamplifier is used for connection directly to Signet 5700 Monitor or 8750 Transmitter or other analog transmitters. ¹HF resistant 2% HF ²Low conductivity applications, 20-100 μs/cm recommended Accessories and Replacement Parts Mfr. Part No. Code Description 1220-0021 198 801 186 O-ring, FPM 3-2700.395 159 001 605 Calibration kit: includes 3 polypropylene cups, box used as cup stand, 1 pint ph 4.01, 1 pint ph 7.00 3822-7115 159 001 606 20 gm bottle quinhydrone for ORP calibration (must use ph 4.01 and/or ph 7.00 buffer solutions) 3-2759 159 000 762 ph/orp System Tester (adapter cable sold separately) 3-2759.391 159 000 764 2759 DryLoc Adapter Cable (for use with 2750 and 2760) 3-0700.390 198 864 403 ph Buffer Kit (1 each 4, 7, 10 ph buffer in powder form, makes 50 ml of each) 3822-7004 159 001 581 ph 4.01 buffer solution, 1 pint (473 ml) bottle 3822-7007 159 001 582 ph 7.00 buffer solution, 1 pint (473 ml) bottle 3822-7010 159 001 583 ph 10.00 buffer solution, 1 pint (473 ml) bottle 3-2724.099 Rev B (10/11) Georg Fischer Signet LLC 3401 Aerojet Avenue, El Monte, CA 91731-2882 U.S.A. Tel. (626) 571-2770 Fax (626) 573-2057 www.gfsignet.com e-mail: signet.ps@georgfischer.com Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.