SERIES PC INSTRUCTION AND OPERATION MANUAL

Similar documents
Series Base mounted pump. Installation and operating instructions

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

S3 General Installation

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Series Base mounted pump. Installation and operating instructions

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODELS 3341 AND 3344 END SUCTION PUMPS

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODEL 3310

Operation and Maintenance Manual Magnetic Drive Sealless Pumps MAXP SERIES

SUMMIT PUMP Horizontal End Suction Pump Close Coupled and Frame Mounted


SERIES G3DB/AG3DB ELEVATOR

PROJ. NO SECTION HYDRONIC PUMPS

Impeller Replacement

1750 RPM Centrifugal Pumps

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

MODEL 442 MODEL 492 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HORIZONTAL SPLIT CASE SPLIT CASE FIRE PUMP FOR

VERTICAL POWER WASHER PUMP

Installation Operation & Maintenance Manual. Oil-Free (Dry) Rotary Vane Vacuum Pump Systems

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR SERIES 470 VM VERTICAL MULTISTAGE PUMPS

NECO Pumping Systems

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

BACK PULLOUT INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS FOR L&H HORIZONTAL PUMP ON JP SHAFT MODELS:

End Suction Centrifugal

PROCESS PUMPS (INDIA) PVT LTD

MAINTENANCE AND REPAIR INSTRUCTIONS

Model 3656/3756. Installation, Operation and Maintenance Instructions. Table of Contents. Owner s Information

1750 RPM Centrifugal Pumps

A9 Heavy Duty Chemical Pump

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

PROCESS PUMPS (INDIA) PVT LTD

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

OPERATION, MAINTENANCE AND OVERHAUL INSTRUCTIONS FOR PB18 SERIES PORTABLE PUMPS

Installation and Maintenance Instructions JSE1-0128MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

PR Series Positive Rotary Pumps

SUMMIT PUMP. Model DSR Single Stage, Double Suction Pumps Installation, Operation, and Maintenance Manual

SERIES FE MAGNETIC COUPLED PUMPS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PROCESS PUMPS (INDIA) PVT LTD

354 CHAPTER EIGHT WATER PUMP

Domestic Pump 2 NPSH Horizontal Pumps Series HB17, HB35, DB, DB-F

SELF PRIMING CHEMICAL SERVICE PUMPS

barmesapumps.com IB SERIES & 3500 RPM Installation, Operation & Maintenance Manual End Suction Centrifugal Pumps

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

Installation, Operation and Maintenance Instructions. Model HS

CUSTOM COMBINATION AIR VALVE

MONARCH MGK-GS MDH-GS Self Priming Centrifugal Pumps OWNER'S MANUAL SAFETY WARNINGS SAFETY CAREFULLY READ THESE SAFETY

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Self-Priming Centrifugal Pumps

PUMP INSTALLATION. Tim Sullivan, P.E. 12/1/2017 PUMP INSTALLATION PRESENTATION 1

NECO Pumping Systems

PROCESS PUMPS (INDIA) PVT LTD

Installation and Maintenance Instructions JSE2-0241MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

series 1500 horizontal pumps

MET-PRO. Fybroc series 1530 horizontal pumps. Global Pump Solutions

Installation, Operation and Maintenance Instructions. Model JC

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

END SUCTION CENTRIFUGAL PUMPS

Installation and Service Instructions. ST Series Pumps

TECHNICAL SERVICE MANUAL

WILFLEY PUMPS MODEL A7. Installation, Operation, Maintenance, and Storage Instructions

1. Wiring Diagrams: Power, signal, and control wiring.

Installation, Operating and Maintenance Instructions. Rotating Machine Screw Actuators. With Parts List Publication Part No.

NOTE: Visit our website at for video repair procedures, under the Tools section.

PROCESS PUMPS (INDIA) PVT LTD

Installation, Operation, and Maintenance Manual _2.0_en- US_ _IOM.HLRange. HL series. Godwin Dri-Prime Pumps

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR SERIES 490 SST & SSU SELF PRIMER PUMPS

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Northern Pump A Division of McNally Industries, LLC

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

Installation Operation and Maintenance Manual

INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR IRONMOUNTAIN MODELS SPL AND SPH SLURRY PUMPS ATLAS EQ. CO.

Installation, Operation and Maintenance Instructions

Installation, Operation, and Maintenance Manual. ANSI Process Pump

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Installation, Operation and Maintenance Instructions. Model 3935

Maintenance Information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

Installation Operation & Maintenance Manual. High Vacuum Lubricated Rotary Vane Pumps

INSTALLATION & MAINTENANCE MODEL mm

LAWN SPRINKLER, IRRIGATION PUMP

WMTA6 LN SERIES SEAL-LESS MAG-DRIVE MULTI-STAGE TURBINE PUMPS

Specifications Information and Repair Parts Manual , , , &

Val-Matic 4-20 Air/Vacuum Valve

Val-Matic 3-72 Cam-Centric Plug Valve

Float Dynamic Steam Trap J10

WILFLEY PUMPS MODEL S3. Installation, Operation, Maintenance, and Storage Instructions

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

barmesapumps.com ANSI 911 Series Installation, Operation & Maintenance Manual ANSI Centrifugal Process Pumps 911 Series

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Transcription:

MEGGA SERIES PC INSTRUCTION AND OPERATION MANUAL Models PCT and PCF Close-coupled and frame-mounted single-stage horizontal end-suction pumps. WARNING: Read this manual before installing or operating this product. Improper use may result in personal injury, property damage and may void product warranty.

Receipt of Shipment INSPECTION: On receipt of the pump set in its shipping container, carefully check for damage. Check the contents against the shipping manifest and report any shortages or damage immediately to the carrier. This will prevent any conflict with the carrier in the event a claim is required. UNLOADING: Handle the unit with care when removing it from its shipping crate. Lift the equipment with suitable slings around the casing and motor lifting eye bolt. On base mounted units it is recommended to lift assembly by slinging through eyebolts mounted to the baseplate foundation holes. STORAGE: Adequate methods of storage are essential to ensure that the pump does not suffer damage from moisture, dust or damage from careless handling. Any deterioration or damage from inadequate storage will not be covered under warranty. If the equipment is not going into service, long term storage procedures should be followed. Installation LOCATION: Locate the pump in an accessible place so that it can be inspected during operation. Place the pump as close to the liquid supply as possible. Provide ample head room and facilities for installation and removal. The pump area should be safeguarded against flooding. FOUNDATION: It is recommended that close coupled pumps be mounted to a sub base to facilitate a secure mounting to a foundation. Baseplate mounted pumps are normally grouted on a concrete foundation which has been poured on a solid footing. The foundation must be able to absorb any vibration and to form a permanent, rigid support for the pumping unit. Sleeved or J bolt foundation anchors are recommended for baseplate mounting. (See Fig. 1) On installations where the pump is to be mounted on a steel skid, it is recommended to through bolt sub base to structure using vibration dampeners between the base and steel structure. Do not weld the baseplate as this will result in greater vibration and noise. Fig. 1 LEVELING: The baseplate should be supported on leveling wedges or shims placed on each side and as close to the foundation bolts as possible. Check the setting with a level and adjust shims as necessary. The wedges or shims should be placed 24 apart around the base. A gap of ¾ to 1-1/2 should be allowed between the baseplate and foundation for grouting. (See Fig.1) GROUTING: When the leveling is correct the foundation bolts should be tightened evenly but not too firmly. Build a dam around the baseplate. The consistency of grout should be such to allow free flowing of the mixture. Follow the mixing recommendations of the manufacturer. 730.008 8/13 1

The dam should be completely filled with grout and allowed to set. At this point the baseplate should be completely filled with grout and allowed to set before finally tightening the foundation bolts. Note: Non grouted baseplates result in higher noise and vibration levels, which lead to reduced overall pump life. PIPING: It is important that the suction and discharge piping be correctly aligned to the pump. The weight of all piping and valves should be supported independent of the pump. Ideally, flex connections should be used at the pump suction and discharge nozzles. All piping should be flushed removing any construction debris, prior to final connection to the pump. Suction piping should be short, direct and one or two sizes larger than the pump suction. Avoid the use of short radius elbows; there should be a minimum of two pipe diameters of straight pipe between the first elbow and the pump inlet. Suction reducers should be eccentric type with the sloping side mounted down. If suction strainers are required they should be sized to have a free area of at least 3 times that of the suction pipe area. On suction lift applications, the suction piping must slope upwards toward the pump suction to eliminate suction pockets, all joints must be air tight. On non-self-priming pumps a means of priming the pump must be provided. On flooded suction applications, an isolation valve should be installed to permit closing of the line for pump repairs. Piping should be level or sloping downward from source of supply, and no portion of the piping should extend below the pump suction flange. Discharge piping should be installed with an isolation valve and check valve. Locate the check valve between the pump and the isolation valve. If reducers are used they should be installed between the pump and check valve. Cushioning devices should be used to protect pump from surges and water hammer if quick-closing valves are installed in the system. COUPLING ALIGNMENT: On frame mounted pumps, the coupling must be aligned as suggested by the coupling manufacturer. Check parallel alignment by placing a straight edge across the coupling flange diameters and measuring the offset at various points around the coupling. Refer to recommended tolerances and shim motor as required. Check angular alignment by measuring the back side of each coupling hub at 90 Deg. Intervals. The difference between the minimum and maximum readings must be less than the misalignment allowed by the coupling manufacturer. Operation Fig 2 PRE-STARTUP CHECK: Confirm that the pump can be turned by hand before checking rotation. On close coupled pumps rotate the motor fan through the small access hole on the fan cover. Bump start the motor and verify that the rotation of the motor corresponds to the 730.008 8/13 2

rotation arrow located on the pump. On close coupled pumps rotation can be difficult to see, the use of a piece of black tape on the exposed part of the shaft can aid in determining rotation. Note: Do not run the pump dry, see priming instructions. PRIMING: Ensure that the pump casing and suction piping is completely filled with liquid before starting the pump. The pump must be vented of all air through the pipe plug located on the top of the pump casing. STARTING: Ensure that the suction line is fully open, and the discharge valve is ¼ open. Turn the starter on and off allowing the pump to rotate and coast to a stop, if the unit stops suddenly or makes any undue noise, correct the problem before proceeding. At this point bring the pump up to its rated speed and slowly open the discharge valve to permit the pump to deliver its rated flow. If there is any excessive noise or vibration shut down the motor and correct the problem. After the pump has been running for some time, check for excessive bearing heat. Temperatures up to 175 F are acceptable providing they are stable and do not continue to rise. Note: Do not operate the pump below 10% of the best efficiency point or rated minimum flow, or against a closed discharge or suction valve. These conditions will lead to rapid pump failure and possible injury STOPPING: Close the discharge valve, shutdown and lockout the power supply. Do not restart the pump until it comes to a complete stop. Exposure to freezing conditions while the pump is idle may cause damage to the pump casing. In these conditions drain liquid from plug provided in bottom of pump casing. Note: When handling toxic or corrosive fluids, precautions must be taken to prevent injury or environmental contamination. Pumpage must be handled and disposed of in accordance with applicable environmental regulations. OPERATION CHECKS: Inspect pump frequently during the first few hours of operation. Mechanical seals may weep slightly, but should run-in in after a few hours of operation. Check motor bearings for excessive heat and check pump assembly for unusual noise and vibrations; correct any problems before restarting pump. Maintenance GENERAL: The pump and motor unit should be checked at regular intervals for any abnormal increase in noise, vibration or operating temperature. Consult the troubleshooting section of this manual for the most common occurring pump problems. BEARINGS: All ball bearings are lubricated at the factory and only require regular maintenance as required by the motor manufacturer. On smaller motors bearings are generally sealed and greased for life bearings and do not require maintenance. On larger motors bearings will have enough lubricant for startup and initial operation of approximately 2000 hours. Consult the motors operation and maintenance manual for proper care of your supplied motor. Frame mounted pumps are grease lubricated and will have enough lubricant for startup and initial operation of approximately 2000 hours. To properly lubricate the frame mounted pump bearings remove the grease relief plugs #113 & #113A to avoid pressurizing the grease chamber. 730.008 8/13 3

Repair REMOVAL: Lock out the power supply to the motor and close off flow control valves to and from the pump. Drain liquid from the pump using the plug provided in bottom of pump casing. Disconnect suction and discharge connections. For close-coupled pumps remove the pump/motor assembly from baseplate. For frame mounted pumps remove the coupling guard, disconnect the coupling and remove the bearing frame/pump from baseplate. DISMANTLING: Refer to relevant exploded parts view drawing for part items specified in the instructions below. 1. Remove casing bolts #370 and pull casing #100 from adapter #108. 2. Remove impeller bolt/washer assembly #198 and impeller gasket #413. Discard gasket. 3. Remove impeller #101 by lightly prying between the impeller and adapter #108, on larger models a standard wheel puller may be required. Note: When prying or pulling impeller, apply loads to the back shroud of the impeller at a point that is supported by the vane. 4. Remove sleeve, sleeve gasket and mechanical seal assembly #126, #412 and #383 from the shaft and inspect for signs of wear. Discard gasket. 5. Remove #108 adapter from motor or bearing frame (note orientation), and push mechanical seal stationary seat from machined counter bore. Replace slinger if required. BEARING FRAME: On frame mounted pumps the following additional repair procedure may be required. 1. Remove bearing housing bolts #370B and the bearing housing #134. Slide the shaft/bearing assembly from the bearing frame #228. 2. Remove the bearing locknut & lockwasher #136 & #382 and press the thrust bearing and radial bearing #112 & #168 off of the shaft. Discard the used bearings and bearing lockwasher and replace with new components. 3. Inspect all components for signs of excessive wear and replacement if required. 4. Reassembly is the reversal of the dismantling procedure. Note: The bearings are installed with their shielded sides inboard and the open sides toward their respective grease chambers. INSPECTION: Inspect impeller and casing #100 and #101 for grooving or dimensional wear and replace if worn. Inspect lapped surfaces of seal # 383 for grooving, cracking or scratches. The mechanical seal should always be replaced or as a minimum re-lapped. Check shaft run out with a dial indicator and replace bearings if required, shaft run out should not be more than.002. Inspect the shaft sleeve for signs of wear or grooving replace if required. ASSEMBLY: Reversal of dismantling procedure noting the following: 1. Refer to general mechanical seal installation instructions provided by seal manufacturer. Carefully install mechanical seal stationary seat into machined bore of adapter, #108. Lightly lubricate seal cup and press with fingers or special tool into the adapter, making sure seat is square and all the way to the bottom of the adapter bore. Note: Use a nonabrasive liquid hand soap to lubricate seal bellows and cup. Do not use oil or grease. 2. Mechanical seal rotating assembly should be assembled as detailed below in Fig. 3. Note: Do not use the stamped sheet metal spring holder supplied by the mechanical seal manufacturer; the spring holder is incorporated into the sleeve design. The rotating assembly should be installed on sleeve #126 by lightly lubricating the sleeve and pushing seal head over shaft sleeve. 730.008 8/13 4

The seal #383 must be installed on the sleeve first and then the whole assembly installed on the shaft. Install a new sleeve gasket, # 412. Fig. 3 3. If the impeller bolt/washer assembly, #198, has been disassembled, then the impeller bolt and washer must be reassembled using a suitable thread retaining compound such as Loctite. This will insure a liquid tight seal around the bolt/washer threads. Install a new impeller gasket, #413. 4. Install new casing gasket, #351, and tighten casing bolts, #370, evenly. Check for free rotation. Spare Parts RECOMMENDED SPARES: Pump: Item # Description # 123 Slinger # 126 Shaft Sleeve # 351 Casing Gasket # 383 Mechanical Seal # 412 Sleeve Gasket # 413 Impeller Gasket Bearing Frame: Item # Description # 112 Thrust Bearing # 168 Radial Bearing # 382 Bearing Lock Washer ORDERING SPARES: Spare parts can be ordered using the enclosed parts list. The pump serial number and model number should be given from the pump name plate. In the case of auxiliary equipment that may have been supplied with the pump quote the full name plate data and describe the part fully. Troubleshooting INSUFFICIENT CAPACITY: 1. System head is greater than pump design head. 2. Ensure the driver speed is correct. 3. Impeller is clogged. 4. Check that all valves and discharge line is fully open. 5. Check for correct rotation. 6. Suction lift is too high or insufficient submergence of the suction pipe. 7. Incorrect impeller diameter. 8. Excessive impeller clearance. 9. Fluid viscosity or specific gravity is greater than that for which the pump is capable. 10. Pump is not primed or is air-bound. 11. Air leaks in suction pipe system. 12. Insufficient NPSH available. Loss of suction following a period of satisfactory operation: 1. Air leaks in suction pipe system 2. Mechanical seal failure, causing pump to loose prime. 3. Suction lift too high or insufficient NPSH available. 4. Entrained air or gas in pumped fluid. 730.008 8/13 5

5. Defective casing or flange gasket. 6. Clogged suction strainer. PUMP OVERLOADS DRIVER: 1. Driver speed too high for pump design. 2. System head is too low and pump is delivering too much flow. 3. Liquid is of greater viscosity or specific gravity than the pump was sized for. 4. Binding or rubbing of rotation element. Check for impeller rub, faulty bearings or a bent shaft. 5. Impeller may be oversize. Check with supplier before taking corrective action. EXCESSIVE VIBRATION: 1. Insufficient submergence of suction. 2. Impeller clogged or out of balance. 3. Worn out bearings, from over or under greasing. 4. Bent shaft 5. Misalignment due to piping strain on pump. 6. Foundation is not sufficiently rigid. 7. Insufficient NPSH available. 730.008 8/13 6

Parts List & Exploded Parts View Pump Parts List Refer to Fig. 4 Item Description 100 Casing includes: 408 Drain Plug 101 Impeller 108 Motor Adapter 122A Stub Shaft 123 Slinger 126 Shaft Sleeve 178 Impeller Key 198 Impeller Bolt/Washer Assembly includes: 199 Impeller Washer 304 Impeller Bolt 351 Casing Gasket/O ring 370 Casing Bolt 371 Motor Bolt 383 Mechanical Seal 412 Sleeve Gasket 413 Impeller Gasket Bearing Frame Parts List Refer to Fig. 5 Item Description 109 Bearing End Cover 112 Thrust Bearing 113 Plug Grease Relief 113A Plug Grease Relief 122 Shaft 134 Bearing Housing 136 Bearing Locknut 168 Radial Bearing 193 Grease Fitting 193A Grease Fitting 228 Bearing Frame 370A Bolt Bearing End Cover 370B Bolt Bearing Housing 382 Bearing Lockwasher 730.008 8/13 7

MOTOR JM FRAME 123 371 108 351 383 126 412 178 101 370 413 198 199 304 100 408 MOTOR 56C FRAME 122A Fig. 4 - Pump Exploded Parts View 8

370B 193A 134 136 382 112 122 113A 168 228 113 109 370A 193 Fig. 5 - Bearing Frame Exploded Parts View 9