Composite Insulators Suspensions Line Posts Brace Posts Station Posts

Similar documents
RODURFLEX LAPP INSULATOR COMPANY LLC THE POWER OF RELIABILITY THE COMPOSITE INSULATOR SYSTEM. Over 30 Years Experience with the RODURFLEX System

POLYMER INSULATOR. Index

Transmission Suspension Insulators

Hi*Lite XL Suspension Insulators

Hi*Lite XL Transmission Insulators

INSULATORS.

CATALOGUE FOR COMPOSITE INSULATOR

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

PRODUCT CATALOGUE. Overhead System

PORCELAIN INSULATORS

5 SPECIAL CRIMPING TECHNOLOGY

WINNING ELECTRICAL CO., LIMITED

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

CATALOG NUMBER 081 BALTIMORE, MARYLAND

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

High Voltage Surge Arresters Station Class

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Bharat Heavy Electricals Limited. Ceramic Business Unit

JOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations

ANSI Design Test Report ANSI Glass Bells Catalog # PSN21156

Surge Arrester 3EL2 superior protection up to 550 kv

BHATINDA CERAMICS PRIVATE LIMITED (Mfrs/Exporters of High Tension Porcelain Insulators)

3EK7 Distribution Class Surge Arresters. Answers for energy.

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

PPC Porcelain Solid Core Post Insulators and Operating Rods ANSI

Glass insulators for kv overhead lines and substations. Global Insulator Group

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Station Post Insulators

TABAN NIROO CO. DENA POWER LINE INSULATORS

3EK7 Distribution Class Surge Arresters. Answers for energy.

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

INSULATING LINKS, ISO/LINK AC & DC

3EQ Composite Housed Surge Arresters

25 kv Apparatus Bushings

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

KEE HING CHEUNG KEE CO., LTD. DLFTZ CHANG HING KEE INT L INDUSTRY & TRADE CO., LTD.

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

15 kv and 25 kv Thru-Bushings

CLICK-FIT. High Voltage Accessories for Extruded Cables

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Polymer Insulators A Better Solution

Insulators. Station post INSULATORS

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

Energy Division. PCA Single Column Polymeric Surge Arrester

INNOVATIONS & NEW DEVELOPMENTS OF COMPOSITE INSULATORS. CIGRE, North Africa Regional Conference, Tunis, Tunesia,

Surge Arresters. Supply Program. Answers for energy.

Five Hoses. Two Fittings. One Solution. GLOBALCORE The world s first high-performance, cohesive hose and fitting system.

Five Hoses. Two Fittings. One Solution. GLOBALCORE The world s first high-performance, cohesive hose and fitting system.

GLASS INSULATORS FOR OVERHEAD POWER TRANSMISSION LINES

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Power Transmission Equipment. Allbest Creative Development Ltd. (ALLBEST)

310HD Double-Offset High-Performance Butterfly Valve

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

Disconnectors and earthing switches up to 25 kv AC

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

REFERENCES ON COMPOSIT INSULATORS. isoelectric

TEKNISK RIKTLINJE TR05-10E

High Voltage Cable Accessories Product catalog

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

SILICONE COMPOSITE BUSHINGS SBC Series

DuraBlue Composite Water-Lubricated Stern Tube Bearings

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

produces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Catalog 14A January 2013

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

PROVINCIAL ELECTRICITY AUTHORITY

Dimensions mm Dia. B Dia. C Dia. D Rad. E. Min F.L. kn SHLV1 SHLV2 SHLV

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Design Test Report Report No. EU1529-H ANSI C29.18 PROTOTYPE/ CEA LWIWG 02 DESIGN TEST REPORT Silicone Rubber 25 kv Veri*Lite Line Post 80S025

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany

Austin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers.

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Eclipse. The Power of Design Innovation. Series

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

COMPLETE RAIL SOLUTIONS. Overhead Electrification Infrastructure. e: p: w: ar-tech.com.au

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

TG/RB/2M/Web Rev.12/1/16. Pipe Hangers & Devices

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Prototype Test Report Quadri*Sil 300 Line Post Insulators Report Number: R

Transcription:

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

Quality, reliability and consistency for over four decades As an alternative and complement to our range of proven ceramic insulators, Lapp Insulators offers the Rodurflex advanced technology insulator system.today these composite insulators made of highgrade synthetic materials have exhibited outstanding mechanical and electrical characteristics, and have exceeded all overhead line and switchgear engineering applications in more than 50 countries worldwide. 1965 Development of composite insulators begins with a twocomponent system consisting of a rod made of fiberglass reinforced plastics (FRP) encased in a silicone elastomer housing. 1967 Suspension class Rodurflex production begins. 1974 Hydrolysis resistant resin system for a fiberglass reinforced resin rod is introduced. 1979 High temperature vulcanized (HTV) silicone rubber is introduced, improving the mechanical characteristics of the material. 1979 Sheath thickness of the housing is increased to 3mm to reduce electrical field strength within the FRP rod and provide better protection during handling and installation. 1982 Metastable silicone sealing system is developed to prevent moisture ingress to the FRP rod. 1983 Acid resistant glass fibers (ECR) are introduced to prevent brittle fracture of the FRP rod. 1985 Compression type, forged steel end fittings are introduced to improve the system s mechanical strength. 2001 Lapp Insulators purchases Ph. Rosenthal & Company the polymer insulator division of Germanbased CeramTec AG inventor of Rodurflex composite insulators, and a global leader in the production of lightweight silicone rubber polymer insulators. 2005 Lapp Insulators begins domestic production of Rodurflex high voltage composite insulators capable of servicing North American utility companies from its Sandersville, Georgia international distribution center.

Rodurflex Insulators are wellsuited for: High contamination applications Areas where vandalism is a problem High creepage on a short length Compact line applications Key Features Outstanding resistance to environmental factors such as UV light, ozone, acid, contamination and moisture. Interior tensile strength higher than steel, despite weighing approximately 75% LESS. Worldwide transmission system applications up to 765 kv. Reduced installation costs. No heavy lifting equipment required. High resistance to discharges and leakage currents. Reduced creepage requirtements for optimal performance when compared to porcelain, due to hydrophobic properties. Greater resistance to vandalism. High explosion resistance of hollow insulators in case of internal pressure buildup. 20 UP 24 TO INCHES FEET The Rodurflex design allows for infinitely variable section lengths & creepage distances for every product. Inside the Lapp Rodurflex System Waterrepellent, UV and coronaresistant silicone rubber base polymer housing. Premolded weathersheds are chemically bonded to the housing, eliminating moldlines and allowing variable creepage distances for a fixed insulator length. Metal fittings are fixed to the fiber glass core, not the silicone housing for maximum mechanical strength. Corona ring applied to the metal fittings to protect the housing. Housing is chemically bonded to the fiberglass core. Hydrolysisresistant resin system applied to the fiberglass reinforced resin rod. 3mmthick high temperature vulcanized (HTV) silicone rubber sheath improves the system s mechanical characteristics while reducing FRP rod s electric field strength. Also protects the FRP rod during handling and installation. Metastable silicone sealing system prevents moisture ingress to the FRP rod. 1

Lapp Rodurflex Catalog Numbering System SML (LBS) CS2=25k CS3=30k CS5=50k CS6=80k CS7=100k SECTION LENGTH (INCHES) Section length must be indicated with 3 digits and rounded to the nearest inch. Suspension Insulators TOWER END FITTING Y= Y Clevis S= Socket E= Oval Eye C= Clevis T= Tongue B= Ball LINE END FITTING B= Ball E= Oval Eye T= Y= Tongue Y Clevis C= Clevis S= Socket CREEPAGE DISTANCE (INCHES) Creepage Distance must be indicated with 3 digits and rounded to the nearest inch. CORONA RING A= None (Standard Design) B= kv (Line End) C= 345 kv (Line End) D= 500 kv (Both Ends) Sample Number CS2041YB074A

Suspension Insulator Mechanical Rating SML: 25,000 lbs 111 kn RTL: 12,500 lbs 56 kn Section Length Available End Fittings Socket:ANSI 525 Tongue:ANSI 526 0.69 0.50 0.89 0.75 Ball:ANSI 525 YClevis 45 Clevis:ANSI 526 Oval Eye 1.57 0.79 0.69 1.4.67 1.18 1.24 2.36 TYPICAL PART ANSI SECTION CREEPAGE ARCING LOW FREQUENCY CRITICAL IMPULSE WEIGHT LINE NUMBER CLASS LENGTH DISTANCE DISTANCE FLASHOVER FLASHOVER VOLTAGE DRY WET POS NEG 69 CS2036YB064A CS2036YB092A 36 64 92 27 269 257 446 455 7 9 69 CS2040YB072A CS2040YB101A 40 72 101 31 307 287 506 516 7.5 9 69/115 CS2047YB089A CS2047YB127A 601 47 89 127 38 374 337 609 622 8 11 115 CS2054YB106A CS2054YB120A 602 54 106 120 45 442 388 713 729 9 10 138 CS2060YB121A CS2060YB145A 603 60 121 145 51 499 431 801 820 10 11.5 138/161 CS2065YB140A CS2065YB159A 604 65 140 159 56 547 468 875 896 11 12 161 CS2071YB141A CS2071YB170A 605 71 141 170 62 605 511 964 988 11 13 161 CS2077YB157A CS2077YB190A 606 77 157 190 68 663 555 1053 1079 12 14 161/ CS2083YB187A CS2083YB215A 607 83 187 215 74 720 598 1141 1170 13.5 15 CS2088YB192A CS2088YB225A 608 88 192 225 79 768 634 1215 1247 14 16 CS2097YB234A CS2097YB295A 609 97 234 295 88 854 699 1347 1383 16 20 CS2107YB244A CS2107YB305A 6010 107 244 305 98 950 772 1495 1535 16 20 345 CS2120YB257A CS2120YB309A 6012 120 257 309 111 1075 866 1688 1734 17 20 500 CS2137YB307A CS2137YB382A 6013 137 307 382 128 1238 990 1939 1991 20 24 1. All section lengths are based on YClevis & Ball end fittings. 2. Electrical data shown for insulators without corona rings. Lapp recommends corona rings to be installed at kv and above. 3. Additional section lengths and creepage distances are available. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds. 3

Suspension Insulator Mechanical Rating SML: 30,000 lbs 133 kn RTL: 15,000 lbs 67 kn Section Length Available End Fittings Socket:ANSI 525 Tongue:ANSI 526 0.69 0.50 0.89 0.75 Ball:ANSI 525 YClevis 45 1.57 Clevis:ANSI 526 Oval Eye 0.79 0.69 1.4.67 1.18 1.24 2.36 TYPICAL PART SECTION CREEPAGE ARCING LOW FREQUENCY CRITICAL IMPULSE WEIGHT LINE NUMBER LENGTH DISTANCE DISTANCE FLASHOVER FLASHOVER VOLTAGE DRY WET POS NEG 69 CS3042SB080A CS3042SB113A 42 080 113 34 333 306 545 557 7 9 69/115 CS3048SB090A CS3048SB130A 48 90 133 40 390 349 633 648 8 11 115 CS3054SB101A CS3054SB120A 54 101 120 46 449 393 724 741 8 10 138 CS3060SB112A CS3060SB141A 60 112 141 52 506 436 812 831 9 11 161 CS3068SB130A CS3068SB163A 68 130 163 60 583 494 930 953 10 12 161 CS3074SB145A CS3074SB178A 74 145 178 66 641 538 1019 1045 11 13 161/ CS3083SB168A CS3083SB201A 83 168 201 75 726 603 1151 1181 12 14 CS3089SB184A CS3089SB231A 89 184 231 81 784 647 1240 1272 13 16 CS3096SB153A CS3096SB243A 96 153 243 87 850 696 1342 1377 11 16 /345 CS3104SB170A CS3104SB241A 104 170 241 95 928 755 1461 1500 11 16 345 CS3120SB243A CS3120SB333A 120 243 333 111 1082 871 1698 1744 16 21 345 CS3130SB281A CS3130SB352A 130 281 352 122 1178 944 1846 1896 18 22 345/500 CS3140SB301A CS3140SB372A 140 301 372 132 1274 1016 1994 2049 19 23 500 CS3170SB350A CS3170SB482A 170 350 482 162 1562 1234 2438 2505 21 29 500/765 CS3180SB398A CS3180SB483A 180 398 483 171 1658 1305 2584 2656 24 29 765 CS3195SB432A CS3195SB526A 195 432 526 187 1801 1414 2806 2884 25 31 4 1. All section lengths are based on Socket & Ball end fittings. 2. Electrical data shown for insulators without corona rings. Lapp recommends corona rings to be installed at kv and above. 3. Additional section lengths and creepage distances are available. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds.

Suspension Insulator Mechanical Rating SML: 50,000 lbs 222 kn RTL: 25,000 lbs 111 kn Section Length Available End Fittings Socket:ANSI 5211 Tongue:ANSI 5212 0.94 0.875 1.25 0.87 Ball:ANSI 5211 YClevis 45 Clevis:ANSI 5212 Oval Eye 181 1.02 1.0 2.2.67 1.18 1.46 2.36 TYPICAL PART ANSI SECTION CREEPAGE ARCING LOW FREQUENCY CRITICAL IMPULSE WEIGHT LINE NUMBER CLASS LENGTH DISTANCE DISTANCE FLASHOVER FLASHOVER VOLTAGE DRY WET POS NEG 69 CS5045EB073A CS5045EB087A 45 73 87 32 314 292 516 527 14 15 115/138 CS5056EB103A CS5056EB122A 56 103 122 43 419 371 678 694 17 18 138 CS5062EB114A CS5062EB132A 62 114 132 49 477 415 767 786 17 19 138/161 CS5068EB129A CS5068EB153A 68 129 153 55 535 458 856 877 19 20 161 CS5074EB140A CS5074EB173A 74 140 173 61 593 502 945 968 19 22 161 CS5080EB155A CS5080EB188A 701 80 155 188 67 650 545 1033 1059 21 23 CS5092EB181A CS5092EB219A 702 92 181 219 79 765 632 1210 1241 23 25 CS5100EB199A CS5100EB237A 703 100 199 237 87 843 691 1330 1365 24 26 /345 CS5106EB162A CS5106EB228A 106 162 228 92 898 732 1415 1452 21 26 345 CS5112EB211A CS5112EB334A 704 112 211 334 99 958 777 1507 1547 25 33 345 CS5123EB231A CS5123EB364A 705 123 231 364 109 1062 856 1667 1712 27 36 345 CS5134EB280A CS5134EB370A 706 134 280 370 121 1169 937 1833 1882 30 36 345/500 CS5145EB315A 708 145 315 132 1274 1016 1994 2048 33 CS5145EB381A 381 37 500 CS5154EB333A 154 709 333 140 1360 1081 2127 2185 34 CS5154EB517A 517 47 500/765 CS5185EB402A CS5185EB539A 7011 185 402 539 171 1657 1306 2583 2655 39 49 765 CS5195EB431A CS5195EB676A 195 431 676 181 1751 1376 2729 2805 42 59 1. All section lengths are based on Oval Eye & Ball end fittings. 2. Electrical data shown for insulators without corona rings. Lapp recommends corona rings to be installed at kv and above. 3. Additional section lengths and creepage distances are available. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds. 5

Suspension Insulator Mechanical Rating SML: 100,000 lbs 445 kn RTL: 50,000 lbs 222 kn Section Length Available End Fittings Socket: IEC 60120 Ball: IEC 60120 Oval Eye 1.38 1.14 2.95 TYPICAL PART SECTION CREEPAGE ARCING LOW FREQUENCY CRITIAL IMPULSE WEIGHT LINE NUMBER LENGTH DISTANCE DISTANCE FLASHOVER FLASHOVER VOLTAGE DRY WET POS NEG CS7100EE245A CS7110EE246A 100 110 245 246 80 90 775 910 665 730 1285 1430 1300 1460 49 50 345 CS7120EE376A CS7130EE372A 120 130 376 372 101 110 >950 >950 790 860 1590 1770 1630 1800 64 64 500 CS7150EE371A CS7165EE372A 150 165 371 372 131 145 >950 >950 >950 >950 >2000 >2000 >2000 >2000 65 66 6 1. All section lengths are based on Oval EyeOval Eye end fittings. 2. Electrical data shown for insulators without corona rings. Lapp recommends corona rings to be installed at kv and above. 3. Additional section lengths and creepage distances are available. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds.

Porcelain String Replacement Mechanical Rating SML: 25,000 lbs 111 kn RTL: 12,500 lbs 56 kn 3.00 5.75 Section Length Section Length Section Length Section Length Socket:ANSI 525 Available End Fittings Ball:ANSI 525 YClevis 0.75 45 1.57 NUMBER TYPICAL PART SECTION SECTION CREEPAGE ARCING LOW CRITICAL WEIGHT OF BELLS LINE NUMBER LENGTH LENGTH DISTANCE DISTANCE FREQUENCY IMPULSE VOLTAGE PORCELAIN POLYMER FLASHOVER FLASHOVER DRY WET POS NEG 4 69 5 69 6 69 7 115 8 138 CS2023SB049A 23 23 49 16 173 146 275 328 6 CS2026YB052A 23 26 52 18 198 167 314 375 7 CS2029SB062A 28.75 29 62 22 222 222 374 381 7 CS2031YB064A 28.75 31 64 23 228 387 394 8 CS2036SB069A 34.5 36 69 29 285 270 471 481 7 CS2039YB072A 34.5 39 72 31 306 286 504 515 8 CS2040SB081A 40.25 40 81 33 323 299 530 541 8 CS2043YB083A 40.25 43 83 35 345 315 564 576 9 CS2046SB094A CS2049YB096A 45.6 45.6 46 49 94 96 39 41 381 401 342 358 619 652 633 667 9 1. All section lengths based on Socket Ball and YClevis Ball combinations. 2. Electrical data shown for insulators without corona rings. Lapp recommends corona rings to be installed at kv and above. 3. All dimensions, tolerances and tests are within allowable ANSI standards. 4. All dimensions are in inches and pounds. 7

Lapp Rodurflex Catalog Numbering System ROD SIZE CL2=2.5 SECTION LENGTH (INCHES) Section length must be indicated with 3 digits and rounded to the nearest inch. 2.5 Inch Line Posts BASE END FITTING 0 = Anchor Only 1 = Flat 12 Standard 0 Optional 2 = Gain 12 Standard 0 Optional 3 = Flange 5 BC 4 = Stud Base 3/410 Standard 7/89 Optional LINE END FITTING 1 = Drop Tongue 2 = Horizontal Trunnion 3 = Spade Tongue 4 = Vertical Trunnion 5 = Flange 5 BC CREEPAGE DISTANCE (INCHES) Creepage Distance must be indicated with 3 digits and rounded to the nearest inch. CORONA RING A= None B= Line End Sample Number CL204721104A

Line Post Transmission Insulator Rod Diameter 2.5 14.0 7.00 Section Length Available End Fittings Gain Base Drop Tongue 0.87 1.65 0.75 12.0 14.0 4.53 1.00 12 12.0 3.62 10.0 0.39.87 1.00 Flat Base 12 Horizontal Trunnion:ANSI C29.7 4.00 0.61 8.00 0.87 0.75 0.71 0.79 5 Flange Vertical Trunnion: ANSI C29.7 4.00 6.18 4 Holes 0.69 On 5.00 B.C. TYPICAL PART ANSI SECTION CREEPAGE ARCING LOW CRITICAL RCL WEIGHT LINE NUMBER CLASS LENGTH DISTANCE DISTANCE FREQUENCY IMPULSE LBS VOLTAGE FLASHOVER FLASHOVER DRY WET POS NEG 69 69/115 115 138 161 161 345 CL203522059A CL203522078A 35 59 78 22 190 189 368 410 3066 69 65 CL204222080A CL204222090A 25041 42 80 90 29 289 270 482 526 2417 57 69 CL204822096A CL204822105A 25047 48 96 105 35 370 335 579 624 2048 71 72 CL205422111A CL205422130A 25054 54 111 130 42 448 397 676 723 1774 75 77 CL206022127A CL206022141A 25060 60 127 141 48 521 457 773 822 1567 78 80 CL206822154A CL206822173A 25066 68 154 173 56 615 533 902 954 1355 84 86 CL207522166A CL207522190A 25075 75 166 190 63 692 595 1016 1070 1211 88 90 CL208522195A CL208522223A 25085 85 195 223 73 793 676 1178 1234 1052 94 97 CL209022210A CL209022238A 90 210 238 78 841 715 1260 1318 987 98 101 CL209622220A CL209622249A 25095 96 220 249 84 893 757 1356 1415 920 101 104 CL210522A CL210522291A 250105 105 291 94 967 817 1502 1565 833 104 111 1. All section lengths are based on Gain Base & Trunnion end fittings. 2. Electrical data shown for insulators without corona rings and mounted horizontally. Lapp recommends corona rings to be installed at kv and above. 3. Additional section lengths and creepage distances are available. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds. 9

Lapp Rodurflex Catalog Numbering System ROD SIZE CL1=1.75 SECTION LENGTH (INCHES) Section length must be indicated with 3 digits and rounded to the nearest inch. 1.75 Inch Line Posts BASE END FITTING 0 = Anchor Only 1 = Flat 6 Upsweep 2 = Gain 6 Upsweep 3 = Flange 3 BC 4 = Stud Base 3/410 Standard 7/89 Optional LINE END FITTING 1 = Drop Tongue 2 = Horizontal Trunnion 3 = Spade Tongue 4 = Vertical Trunnion 5 = Flange 3 BC CREEPAGE DISTANCE (INCHES) Creepage Distance must be indicated with 3 digits and rounded to the nearest inch. CORONA RING A= None B= Line End Sample Number CL102844053A TYPICAL PART ANSI LINE END LINE NUMBER CLASS FITTING VOLTAGE 46 CL102044031A 5114 Vert.Trunnion 46/69 CL102444044A 5115 Vert.Trunnion 69 CL102844053A 5116 Vert.Trunnion 46 CL102042030A 5124 Horiz.Trunnion 46/69 CL102542044A 5125 Horiz.Trunnion 69 CL102842052A 5126 Horiz.Trunnion 46 CL102322030A 5134 Horiz.Trunnion 46/69 CL102822044A 5135 Horiz.Trunnion 69 CL103022051A 5136 Horiz.Trunnion

Line Post Transmission Insulator Rod Diameter 1.75 Section Length 14.0 7.00 Available End Fittings Gain Base Drop Tongue 1.34 1.38 0.75 12.0 14.0 10.0 6 3.54 1.00 Stud Base 0.75 3/4 10 +.015 Horizontal Trunnion:ANSI C29.7 4.00 0.61 0.75 0.71 Stud Base 0.875 Vertical Trunnion: ANSI C29.7 4.00 7/8 9 +.015 BASE END SECTION CREEPAGE ARCING LOW FREQUENCY CRITICAL IMPULSE RCL WEIGHT FITTING LENGTH DISTANCE DISTANCE FLASHOVER FLASHOVER LBS DRY WET POS NEG 3/4 Stud 20 31 13.8 159 134 250 289 1808 16 3/4 Stud 24 44 17.8 203 171 319 370 1447 18 7/8 Stud 28 53 21.8 190 189 368 410 1209 19 3/4 Stud 20 30 13 150 126 235 272 1808 16 3/4 Stud 25 44 18 205 173 323 374 1380 18 7/8 Stud 28 52 21 239 201 376 435 1209 19 Gain Base 23 30 13 150 126 235 272 1808 35 Gain Base 28 44 18 206 173 323 374 1377 37 Gain Base 30 51 20 229 192 359 416 1258 38 1. Electrical data shown for insulators without corona rings and mounted horizontally. 2. Various section lengths and creepage distances are available. 3. Contact sales agency for details. 4. All dimensions, tolerances and tests are within allowable ANSI standards. 5. All dimensions are in inches and pounds. 11

POST ROD SIZE CBP2=2.5 Lapp Rodurflex Catalog Numbering System SECTION LENGTH (INCHES) Section length of the post must be indicated with 3 digits and rounded to the nearest inch. Braced Posts CREEPAGE DISTANCE (INCHES) Creepage distance of the post must be indicated with 3 digits and rounded to the nearest inch. DESIGN VARIATION This number is assigned by Lapp Engineering. Refer to drawing for individual components. Sample Number CBP207115201 TYPICAL PART POST LINE NUMBER NUMBER VOLTAGE CBP204510701 CL204521107A 115/138 CBP205212801 CBP205814901 CL205221128A CL205821149A CBP206215701 CL206221157A CBP206717701 CL206721177A 161 CBP207018501 CL207021185A CBP207519501 CL207521195A CBP208422701 CBP209024201 CL208421227A CL209021242A CBP209626301 CL209621263A

Braced Post Insulator H Approximately 60 12 Post Section Length SUSPENSION POST POST H MAXIMUM LOW FREQUENCY CRITICAL FREQUENCY NUMBER SECTION CREEPAGE WORKING FLASHOVER FLASHOVER LENGTH DISTANCE LOAD DRY WET POS NEG CS2058EE111A 45 107 60 10,125 320 285 525 585 CS2068EE133A 52 128 68.5 10,125 385 350 615 670 CS2077EE154A 58 149 76.5 10,125 455 410 700 770 CS2083EE160A 62 157 81.8 10,125 505 440 775 860 CS2091EE180A 67 177 89 10,125 560 500 870 915 CS2095EE189A 70 185 92.3 10,125 590 520 915 965 CS2103EE197A 75 195 99.6 10,125 655 560 1000 1035 CS2116EE229B CS2125EE242B 84 90 227 242 111 119 10,125 10,125 630 685 560 610 990 1080 1080 1180 CS2134EE263B 96 263 127 10,125 745 655 1180 1270 1. All braced posts shown with 12 upsweep bendable gain base and standard coupling shackles. 2. Other hardware combinations are available, contact sales agency for details. 3. All dimensions, tolerances and testing are within allowable ANSI standards. 13

Lapp Rodurflex Catalog Numbering System ROD SIZE CP1=1.8 CP2=2.5 SECTION LENGTH (INCHES) Section length must be indicated with 3 digits and rounded to the nearest inch. Station Posts BASE END FITTING 1 = Flange, 3 BC, 1/213+.015 Tapped (Standard Design) 2 = Flange, 5 BC, 5/811+.015 Tapped 3 = Flange, 5 BC, 5/8 Untapped (Standard Design) LINE END FITTING 1 = Flange, 3 BC, 1/213+.015 Tapped (Standard Design) 2 = Flange, 5 BC, 5/811+.015 Tapped 3 = Flange, 5 BC, 5/8 Untapped (Standard Design) CREEPAGE DISTANCE (INCHES) Creepage Distance must be indicated with 3 digits and rounded to the nearest inch. CORONA RING A= None B= Line End Sample Number CP101811041A TR TYPE PART SECTION CREEPAGE WEIGHT POLYMER PORCELAIN DEFLECTION NUMBER NUMBER LENGTH DISTANCE RCL* WL** AT PORCELAIN WL 214 216 278 286 288 291 RODURFLEX PORCELAIN CP102211040A 22 40 43 17 50 1240 2000 RODURFLEX PORCELAIN CP103011072A 30 72 21 79 875 1500 RODURFLEX PORCELAIN CP203033072A 30 72 42 132 2700 3000 RODURFLEX PORCELAIN CP204533101A 45 101 99 50 161 1911 1700 RODURFLEX PORCELAIN CP205433120A 54 120 116 55 200 1575 1450 RODURFLEX PORCELAIN CP206233132A 62 132 59 331 1350 1200 800 0.71 600 1.50 1200 0.75 680 1.69 580 2.64 480 3.4

Station Post Insulator Section Length Available End Fittings 5 Flange 0.79 6.18 4 Holes.69 On 5.00 B.C. Through Hole (Standard) 5 Flange 0.79 6.18 4 Holes 5/8 11 +.015 On 5.00 B.C. 3 Flange 2.5 3.9 4 Holes 1/2 13 +.015 On 3.00 B.C. END MECHANICAL VALUES ELECTRICAL VALUES FITTINGS TENSILE TORSION COMPRESSION IMPULSE 60 HZ WET RIV TEST MAX. RIV.AT (LBS) (INCH LBS) (LBS) WITHSTAND WITHSTAND VOLTAGE 100 KHZ (MICROVOLTS) 3" BC 3" BC 5" BC 5" BC 5" BC 5" BC 11250 14000 8140 12000 11250 15000 265 250 135 100 30 < 200 11250 16000 8140 15000 5845 25000 390 350 190 145 44 < 200 22500 25000 22100 40000 23600 60000 350 160 145 44 < 200 22500 20000 22100 40000 10340 60000 550 265 73 < 200 22500 20000 22100 60000 6750 60000 700 650 355 275 88 < 200 22500 20000 22100 40000 5170 60000 750 315 103 <500 1. * RCL = Reference Cantilever Load for polymer and is the maximum load the insulator can withstand in service. It is approximately 50% of the ultimate cantilver rating of each design. Cantilever shown for porcelain is the ultimate value. 2. ** WL = Working Load of porcelain and is approximately 40% of the ultimate rating. 3. All dimensions are in inches and pounds. 15

KV 345KV 500KV RECOMMENDED CORONA RING APPLICATION Line end YES YES YES Ground end NO NO YES Suspension Part Number suffix B C D Line Post Part Number suffix B B SUSPENSION INSULATOR ADJUSTMENTS WHEN ADDING CORONA RINGS Arcing distance (in) 3 3 6 All suspension corona rings are: 25k, 30k, Low Frequency Flashover Dry (kv) 20 30 60 13.8 OD 50k, 80k, Low Frequency Flashover Wet (kv) 20 20 45 Galvanized steel 100k Critical Impulse Flashover Pos (kv) 40 40 90 Open style Critical Impulse Flashover Neg (kv) 40 40 90 Reversible mounting Weight (lbs) +7 +7 +7.3 LINE POST INSULATOR ADJUSTMENTS WHEN ADDING CORONA RINGS Arcing distance (in) 4 4 All line post corona rings are: 2.5 Low Frequency Flashover Dry (kv) 40 35 13.8 OD Line Low Frequency Flashover Wet (kv) 30 30 Galvanized steel Posts Critical Impulse Flashover Pos (kv) 70 70 Closed Ring style Critical Impulse Flashover Neg (kv) 70 70 Weight (lbs) +9.5 +9.5

Corona Rings 13.8 1.5 kv 2.4 13.8 1.9 345 kv 2.4 13.8 1.9 500 kv 2.0 17

Lapp Insulators, Our Customers Power the Future. Lapp Insulators has been extending the limits of manufacturing high voltage insulators since 1916. Today, we re still putting our unparalleled reputation for reliability on the line through quality, innovation, customer focus and an unwavering commitment to world class performance. At Lapp Insulators, adequate is never enough. That s why we continue to reinvent technologically superior designs and automated manufacturing processes consistent with our ISO 9001 and 9002 certification. Our workflow production schedule and forecasted inventory program ensure customers get the product they need faster than any competition. We do all the necessary quality testing for ANSI and IEC standards twice, and the consistency of our products in the distribution channel is without equal in the industry. It s not all about the product; it s about a passion for excellence too. Every day we go to work with one goal in mind: To always exceed customer expectations.