Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Similar documents
Non-Spring Return EconoDrive Floating Actuator

Bulletin 871P Can Sensors

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

MF /MS Series

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Industrial Power Supplies

Application Engineering

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

INDUSTRIAL POWER SUPPLIES SFL-SERIES

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Installation Instructions

Chandrashekar.p. Electrical and Electronics Engineering, PESITM-Shivamogga, Karnataka-India

Application Engineering

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

J1000. Compact Inverter Series.

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

Low Profile DC Power Supply with Zero Voltage Soft Switching

Description 1/8-7.5HP

M9216 Series Electric Spring Return Actuators

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Solid State Relays contactor with Integrated Fuse Type RGC1F

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

PS6R 480W Switching Power Supply

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

How to Select the RE Industrial Actuator Part Number

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

PRODUCT INFORMATION BULLETIN

LED Driver Linear / area dimming

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

SAV Electronic Valve Actuator

CAUTION CM-SE CM-S21 CM-S41

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Positive displacement batch controller

Commercial Actuator Selection Chart Non-Spring Return

MODEL 422 Submersible Pump Controller

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Adjustable Torque Controls

Appendix. Clearance. Skewed profiles. Application Schematics

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

MF4E MF4E

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Installation and Operation Instructions DLP Series

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

High Frequency SineWave Guardian TM

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Emergency lighting units EM powerled

PRODUCTS: POWER SUPPLY

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Model Number Structure

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

EPS/ELA-Series User Manual EPS/ELA 250W

INSTRUCTIONS. Power Panel. Installation Instructions

MD60 Series 60W DINergy Power Supply

CD3000S-1PH Thyristor Unit Heater Break version

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

SAVE THESE INSTRUCTIONS

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Open Frame Power Supplies

The High Power Stack Horizon

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Installation Instructions

Load (2) Single or Dual

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Softstarter Intelligent Controllers

ABB Component Drives ACS150, 0.5 to 5 Hp

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Versatile and Powerful

Switching Power Supply

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Differential pressure sensor

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Transcription:

Speed Sensor ã Read and understand equipment operators manual before operating or performing maintenance. Failure to do so could result in serious injury or death. Safety Information Failure to follow instructions below could result in death or serious injury: Lockout/Tagout/Blockout before performing maintenance or installation. Follow installation instructions completely. Failure to do so may cause death or serious injury. Wiring Diagram Figure 1 Route Speed Sensor wires/conduit away from electrical power conduit to prevent electromagnetic interference, which results in lost signal and faulty readings. Wiring conduit from control box to Speed Sensor offers greater cable protection. Any damage to cable can interrupt Smart Monitor from receiving sensor signal. Use of flexible conduit prevents need of strain relief. Route wires or flexible conduit along Speed Sensor mounting bracket towards hinge point allowing free motion of hinge. Check wires are not restricting Speed Sensor movement. BN Inputs: pnp/npn; NAMUR (24 V) auxiliary supply : typ. 24 V DC / 15 ma; short-circuit protected threshold pnp: > 12 V on; < 5 V off threshold npn; > 15 V off; < 8 V on Input frequency (max): 5 khz (corresponds to min. pulse length / space 0.1 ms) Outputs Relay Contact Rating - 6 A (250 V AC); B300,R300 Transistor Transistor Outputs -pnp; external supply -switching voltage/current: 24 V DC / max. 15 ma; short-circuit protected Analog Analog Output - 0/4...20 ma Max. Load [ -500 -Limitation: 20.5 ma; accuracy: 1% (of final value) Measuring / Setting Range Setting Rang [pulses/min.] BU -1...60000 (0.1...1000 Hz) pnp BK Electrical Data: Nominal Voltage [V] - 110...240 AC (50...60 Hz) / 27 DC (typ. 24 DC) Voltage tolerance [%] - -20...+10 Power consumption [VA] - 19.6...27.7 DC SELV, < 15 ma 800.321.1558 SE-0453_Speed Sensor_07-2018 65

Clean Side Roll Installation Clean side roll must be installed in a location with free movement or premature failure may occur. Clean side roll may not be used on a reversing belt. If mounted improperly severe roll and belt damage may occur. Clean Side Speed Sensor Wiring death or serious injury. Disconnect and lockout power before performing any maintenance or work on unit. Wear proper PPE during work and maintenance. Figure 2 a b c No setup required for sensor inside return roll. Do not operate without a load. Dead short may result and cause permanent damage. e d DO not use incandescent light bulbs as a load. Overload may occur due to extremely high cold current. Do not pull wires connected to speed sensor. Pulling may cause damage. Do not directly operate a motor with sensor. a. Hinge Point b. Mounting Arm c. Clean Side Roll d. Roll Speed Sensor Install clean side roll speed sensor on clean side of belt. Do not exceed 45 (e) (Figure 2) on mounting arm. Mount in most convenient place to wire. Position roll on top or near return roll. This will prevent belt sagging. Avoiding beater bar or any other such kind of excessive vibration Do not directly operate a motor with sensor. Do not apply voltage directly across speed sensor wires permanent damage may occur. Do not apply power to sensor immediately after installation. Verify circuits meet sensor specifications. Specifications: 1/2 90 elbow conduit access port 2 wire 22 AWG PVC jacket 6 ft.pvc insulation Follow Instructions below for proper clean side roll speed installation: 1. Insert shaft hinge point on clean side roll. 2. Install retaining collar on each end and tighten set screws. Note: Do not fully tighten set screws. 3. Install mounting brackets to conveyor at mounting location. Note: Holes may be need to be drilled on conveyor for brackets. 4. Tighten retaining collar set screws after setting within 1/8 inch of hinge point. 5. Slide shaft sots into slots on mounting brackets and install end clips over shaft. 66 SE-0453_Speed Sensor_07-2018 800.321.1558

Figure 3 Return Roll installation death or serious injury. 2 It is recommenced to run wires/conduit from speed sensor away from electrical power conduit. Electrical power may cause interference with speed sensor signal. 1 Go to Return Roll Installation within conveyor manual for proper return roll installation instructions. Follow instructions below for proper wiring: 1. Rout wiring from monitor to return roll speed sensor. Note: use minimum of 22 AWG shielded cable. 2. Remove cover (1) (Figure 3) from 90 elbow conduit access port 3. Run monitor wire through elbow conduit opening (2) (Figure 3). Figure 4 a b 4. Connect monitor and speed sensor wires. Note: Cut wires to fit within elbow conduit. 5. Install elbow conduit access port cover and tighten screws. a. Return Roll b. Return Roll Bracket c. Speed Sensor c 1. Place speed sensor on return belt side of conveyor. 2. Select which conveyor side conduit/wires for speed sensor will be ran. 3. Ensure drop brackets are installed. 4. Unscrew and carefully remove hex bushing on speed sensor. 5. Run wires from sensor through proper drop bracket and place return roll into brackets. Note: Ensure wiring is not pinched or crushed after being installed through bracket. 6. Lock return rolls into place Note: Bend tab against shaft to fully secure roller. 7. Place wiring through hex bushing and thread onto speed sensor and shaft. 8. Ensure return roll is centered on conveyor. 9. Tighten drop brackets bolt into conveyor frame. 800.321.1558 SE-0453_Speed Sensor_07-2018 67

Return Roll Speed Sensor Wiring death or serious injury. Disconnect and lockout power before performing any maintenance or work on unit. Wear proper PPE during work and maintenance. No setup required for sensor inside return roll. 1. Rout wiring from monitor to return roll speed sensor. Note: use minimum of 22 AWG shielded cable. 2. Remove cover (1) (Figure 5) from 90 elbow conduit access port 3. Run monitor wire through elbow conduit opening (2) (Figure 5). 4. Connect monitor and speed sensor wires. Note: Cut wires to fit within elbow conduit. 5. Install elbow conduit access port cover and tighten screws. Do not apply voltage directly across speed sensor wires permanent damage may occur. DO not use incandescent light bulbs as a load. Overload may occur due to extremely high cold current. Do not operate without a load. Dead short may result and cause permanent damage. Do not directly operate a motor with sensor. Do not pull wires connected to speed sensor. Pulling may cause damage. Do not apply power to sensor immediately after installation. Verify circuits meet sensor specifications. Specifications: 1/2 90 elbow conduit access port 2 wire 22 AWG PVC jacket 6 ft.pvc insulation Figure 5 2 1 Follow instructions below for proper wiring: 68 SE-0453_Speed Sensor_07-2018 800.321.1558

Idler Speed Sensor Installation Return Roll Speed Sensor Wiring Go to idler Installation within conveyor manual for proper return roll installation instructions. It is recommenced to run wires/conduit from speed sensor away from electrical power conduit. Electrical power may cause interference with speed sensor signal. Figure 6 a. Roll b. Frame c. Bracket d. Retainer Clip e. Roll Speed Sensor Figure 7 c a b d e Specifications: death or serious injury. Disconnect and lockout power before performing any maintenance or work on unit. Wear proper PPE during work and maintenance. Do not apply voltage directly across speed sensor wires permanent damage may occur. DO not use incandescent light bulbs as a load. Overload may occur due to extremely high cold current. Do not operate without a load. Dead short may result and cause permanent damage. Do not directly operate a motor with sensor. Do not pull wires connected to speed sensor. Pulling may cause damage. Do not apply power to sensor immediately after installation. Verify circuits meet sensor specifications. No setup required for sensor inside return roll. 1/2 90 elbow conduit access port 2 wire 22 AWG PVC jacket 1 6 ft.pvc insulation Follow Instructions below for proper idler roll speed installation: 1. Place idler on frame, align holes and secure with supplied hardware (1) (Figure 7). 2. With hardware still loose, slide both sides of idler towards head of conveyor. 3. Tighten bolts completely. 800.321.1558 SE-0453_Speed Sensor_07-2018 69

Figure 8 AC to DC Converter 1 death or serious injury. Disconnect and lockout power before performing any maintenance or work on unit. 2 Wear proper PPE during work and maintenance. Consult and follow local and national electrical codes. Setup 1. insure sensor operates on 15 VDC to 18 VDC supply. Follow instructions below for proper wiring: 1. Rout wiring from monitor to idler roll speed sensor. Note: use minimum of 22 AWG shielded cable. 2. Remove cover (1) (Figure 8) from 90 elbow conduit access port 2. insure sensor consumes 100mA or less operating current. 3. Insure sensor contains sink or source output connected to Python s TRIAC switch control line. Note: mis-wiring can render Python permanently non-functional. 3. Run monitor wire through elbow conduit opening (2) (Figure 8). 4. Connect monitor and speed sensor wires. Note: Cut wires to fit within elbow conduit. 5. Install elbow conduit access port cover and tighten screws. Speed Sensor Monitor Refer to speed sensor monitor manual for proper wiring and installation instructions. Figure 9 Speed sensor monitor displays speed of roll sensor is attached to. Sensor monitor is equipped with a low speed detection alarm. 70 SE-0453_Speed Sensor_07-2018 800.321.1558

Connect Source Voltage and Load Checkout Check specifications of Relay or PLC Input before connecting Relay or PLC Input load must be Minimum 1200 ohm at 120 VAC / 2400 ohm at 240 VAC to prevent irreversible damage to Python. Figure 10 death, serious injury or damage to equipment Apply AC load that limits Python s TRIAC switch to rated current. 1. Plug Python's connector into sensor. 2. Check for proper function. Note: When sensor's output switch closes, Python's TRIAC switch should close, energizing applied load or PLC input. Python Specifications AC Power Requirements Supply voltage range: 100 VAC TO 240 VAC, 50/60Hz Current and power consumption: 38 ma max., 4VA max. Installation category: II (IEC 60364-4-443) Input fusing: Non-replaceable, non-repairable DC Output Ratings (to sensor) Output voltage @ rated current: 15 VDC min. Output voltage @ no load: 20 VDC max. Output voltage regulation: 40 V/A Output current, max. rated: 100 ma Output current fault, max.: 200 ma Pri/sec. isolation: 2200 VAC, 1 min. Turn-on delay, 100 ma load, 90% final voltage: 10 ms typical Turn-off delay, 0 ma load, 10% full voltage: 1 sec typical TRIAC Switch Ratings (switch AC current only) Features: Optically isolated, zero-crossing Switch voltage, maximum: 230 VAC Switch current, maximum: 50 ma@230 VAC, 100 ma@120 VAC Peak repetitive surge current: 1 A (100µs, 120pps) On-state voltage: 3 V max @ 100mA Off-state leakage: 500 na max. Holding current: 250 µa typ. Critical rate of rise of off-state voltage: 600 V/us min. Isolation surge voltage: 7500 VAC min, 60 Hz. 1sec. 800.321.1558 SE-0453_Speed Sensor_07-2018 71

Turn-on time, full load, max voltage: 15 ms max. (zero-crossing) Turn-off time, full load, max voltage: 15 ms max. (zero-crossing) Over-current protection: Internal fuse (non-replaceable, nonrepairable) Minimum Load: 1200 ohm at 120 VAC, 600 ohm at 240 VAC Mechanical & Cables Material: PVC Body dimension, length x diameter: 152 mm (6 in.) x 24 mm (0.95in.) AC cable: 4-wire, 18AWG, 300V, PVC: 2 m (79 in.) x 7 mm (0.28 in.) dia. DC cable: 4-wire, 22AWG, 300V, PVC : 1 m (39 in.) x 5.2 mm (0.21 in.) dia. Environmental 2. Sensor is receiving power but does not actuate Python's TRIAC switch: Python's TRIAC is a floating switch. External power source must be applied to load circuit which TRIAC acts as switch. Be extremely careful not to allow currents greater than rated current to flow through the TRIAC switch or permanent damage may occur. Internal fuse may blow if current is applied in excess of rating. Fuse is not replaceable. 3. Python presents proper output voltage when disconnected from sensor but will not correctly power sensor when connected: Sensor may be drawing too much current causing Python's output voltage to fall below a useful level. Excess output loading may also be caused by a load on sensor's PNP (sourcing) output line that, in addition to sensor's current requirement, exceeds capacity. Figure 12 Operating temperature: -25 C to 60 C (-13 F to 140 F) Storage temperature: -40 C to 85 C (-40 F to 185 F) Humidity: 100%, non-condensing Enclosure ratings: Type 1 (UL50), IP67 Approvals / Certifications North Amer. Safety: UL, UL-cUL: 61010C-1, "Industrial Control Equipment" File #E238344 European safety: CE: EN 61010C-1 North American emissions: FCC: Class A EU emissions: CE: EN55011:1998 Group 1, Class A EU EMC: EN61326:1997 Measure, Lab., and Control Materials safety: FDA: cables and over-mold are FDA compatible non-contact Dimensions Figure 11 Diagnostics 1. Everything is connected but sensor does not appear to operate: Disconnect sensor and check for proper DC output voltage at Python connector. 72 SE-0453_Speed Sensor_07-2018 800.321.1558

Replacement Parts Return Side Speed Sensor Clean Side Speed Sensor Clean Side Roll Speed Sensor 26-100001 Speed Roll D5-36LAG.25SPEED Return Roll Return Roll w/ Lagging Speed Senor Module C5-RET-36SPEED C4-RET-36LAG.5SPEED Clean Side Mounting Bracket DD2503 Speed Sensor Module 11-04136 Clean Side Mounting Bracket 26-100002 Composite Module Enclosure Troughing Side Speed Sensor Trough Roll Trough Roll w/ Lagging Trough Idler w/ Speed Sensor Roll C5-36SPEED C4-36LAG.5SPEED C5-35E-36SPEED Module Enclosure - Composite 11-04229 800.321.1558 SE-0453_Speed Sensor_07-2018 73

Steel Module Enclosure Module Enclosure - Steel 11-04230 Power Cord Power Cord 11-04204 Note: Cut to specific length. Speed Converter Sensor Converter 11-04557 74 SE-0453_Speed Sensor_07-2018 800.321.1558