Similar documents
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

SL-150 Magnetic Lock for Sliding Door Installation Manual

MODEL 1200S MAGNETIC LOCK

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

Shaved-B. Installation Manual & Operation Instructions

Installation Instructions for Slide Mount Magnetic Locks

Security and Keyless Entry Installation Guide ca 1051

MODEL 1200S MAGNETIC LOCK

SHAVED-DX. Installation Manual & Operation Instructions. Trouble Shooting Reverse Polarity Wiring Problems

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

MCC Automatic Start-Stop Microcomputer Charger Control

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

INSTALLATION/OPERATING INSTRUCTIONS TSC

Model APS-101N Installation Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

IMPORTANT! Remote Control Instructions

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLER MANUAL USER MANUAL. Contents

Remote Keyless Entry Installation Guide ca 2051

YG101 SWING GATE OPENER OWNER S MANUAL

Lippert Components, Inc. Informational Publication ENTRY DOOR LATCH INFORMATION - SOUTHCO

CD3000S-1PH Thyristor Unit Analog Input version

Vehicle Security System

Model PRO 9644a Installation Manual

HANDLING MECHANICAL INSTALLATION

Electric Actuator Instructions

Installing the gate post bracket with the cardboard arm template

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Installing the gate post bracket with the cardboard arm template

Carbon Monoxide Transmitter

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

Compact Low Pressure Sensor

M670/M680BD MAGNALOCK SERIES Installation Instructions

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

CD3000S-1PH Thyristor Unit Heater Break version

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

V2M1200/1290 Series Maglock Installation Instructions

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

Security Door Controls

DLKEK3HN INSTALLATION INSTRUCTIONS

ADA EZ Rev. H, 8/23/11

CM 5000D IN A HURRY?

Signet Pressure Transmitter

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

Troubleshooting Bosch Proportional Valves

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller

Vehicle Security System

Manual - Inside Front Cover (Blank)

Signet Pressure Transmitter

USERS GUIDE LO-21U LOCKOUT RELAY

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Signet Temperature Transmitter

2 Way Security and Keyless Entry Installation Guide ca 1553

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

INSTALLATION/OPERATING INSTRUCTIONS MCP

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

CA-110 Installation Instructions

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Fitting Instructions. Armlock 1354 Mini Electro-Shearmagnet (Surface) Contents

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

6500DC Dual Motor Wireless Controller Kits

TRAC-Station BT Installation Instructions

GLM SERIES CONTROL Users Manual Rev:

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

5002/5005 Bike Repair Guide Version 2; Date:

ST Charger. Industrial Battery Charger

Two Channel Remote Shutdown Device

INSTALLATION GUIDE. FCC ID NOTICE

TC62D Installation Instructions

Model APS-25CH Installation Manual

N1233 Series Troubleshooting Guide for N Alternator

EA07. Generator Automatic Voltage Regulator Operation Manual

MANUAL. MiniMax V / VK

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Solid-State Compass with GPS Receiver

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

Model APS-25N Installation Manual

3 Slot Payphone Controller

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

SCHEMATIC AND ROUTING DIAGRAMS

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller

SKC400U SLIDING GATE OPENER OWNER S MANUAL

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

Instruction Manual for the. E-SL 450 Series

Transcription:

Instructions For PG-1200RC Magnetic Locking Devices (Remote control distance up to 10 meters) Ver. 18.1 Please Read Carefully Before Installing Magnetic Lock A. Carefully for handling to prevent damage for the plate surface of magnet or armature, it may reduce locking efficiency. B. The magnet must be mounted rigidly to the door frame. Then fix the armature to the door by using the screws. If the door can not be fixed closely, you may move the armature, so that it can match with the surface of the magnet completely. C. Firmly tighten all screws. Typical Installation STEP 1 A. Fold template along dotted line. B. Place template against door and head frame. C. Drill holes as indicated on template. STEP 2 A. Mount the armature plate to door by using 1 rubber washer sandwiched between 2 steel washers. ( The rubber washer and 2 steel washer are installed on the through Hexagon screw between armature plate and door). STEP 3 A. Install the mounting plate with 2 flat head screws (the 2 M5 5 flat head screws are installed on the slotted holes for adjustment). B. Adjust the mounting plate so that it forms right angle with the armature plate. C. Using the mounting plate as a temple, drill the wire hole. D. Drill the remaining mounting screws. 1

STEP 4 A. Install magnet to mounting plate with 2 M4 screws supplied. STEP 5 A. Test all functions of this model (see wiring instruction). Armature Plate Mounts To The Door: *Important:Do not fix the armature plate too tightly, and make the rubber washer more flexible in order to let the armature plate automatically adjust its proper position with magnet. 12VDC Input: A. Required power 1.0Amp ( Minimum ). B. Connect the ground (-) lead from a 12VDC power source to Black line. C. Connect the positive (+) lead from a 12VDC power source to Red line. D. Check jumper for 12VDC operation. 24VDC Input: A. Required power 0.5Amp ( Minimum ). B. Connect the ground (-) lead from a 24VDC power source Black line. C. Connect the positive (+) lead from a 24VDC power source to Red line. D. Check jumper for 24VDC operation. Contacts: A. Relay dry contacts are rated as 24VDC/1.0A for safe operation. Do not exceed this rating. B. If you require a normally opened dry contacts, please connect the wires of Yellow and Orange. If you require a normally closed dry contacts, please connect the wires of Yellow and Green. 2

Printed Circuit Board Schematic The procedure of adding /deleting transmitter (up to 40 transmitter s ID.) 1. Adding transmitter 1.1 Adjust the JUMPER(JP) to the desired channel to receive. The communication indicator will flash. After 35 seconds; It means the programming is complete. 1.2 Pressing the learning mode button(msw1) on the PCB, the communication indicator will flash and starting learning mode. (The learning mode will be automatically closed after 35 seconds of inactivity) 1.3 According to the channel set by JUMPER (JP), press the corresponding button on the PTX-204DF to match. 1.4 After all the transmitters are matched, please power off the lock and put on the armature plate. After 3 seconds, re-power the lock and wait the lock is activated (the armature is secured), press the matched button on PTX-204DF. If the armature plate is released, that means the setting is completed. 2. Deleting transmitter If any transmitter is lost, all transmitters should be deleted and reprogrammed. Pressing the learning mode button for 10 seconds without re-power, the communication indicator will flash to complete the deleting. Important A. The product should be only supplied with UL listed power supply. B. If the power switch is not wired directly between DC voltage source and magnet, it will take time to de-energize the residual magnetism(see below). C. Please make sure your jumper pin is in the proper position. 3

Wiring connection with reader Dimensions: mm[inch] Q & A FOR PML series: A. Once powered, the pilot light isn t responded to ON : (1) If the voltage selection of the printed circuit board was set DC 24V, please check your power supply with at least DC 24V, 500mA. (2) Maybe the DC (+), (-) polarity is reversed. (3) Maybe the jumper was put in wrong position, please reverse it and try again. 4

B. Once powered, if pilot light turns on, but lacking magnetic force and magnet could not attract the armature, the reasons may be as follows: (1)Please check if the power voltage is larger than DC24V (power supply must be DC24V, 500mA+/-5% Minimum) (2)Maybe the magnet & armature do not match completely tight, please adjust the position between the magnet and armature. (3)The transformer s quality causes interference please check if the poor quality of the transformer induced the interference. If yes, please replace another one. C. Once powered, the pilot light turns on, but the magnetic force is not enough: (1) The magnet and armature cannot attract tightly, please check if there is some dust between them. (2) The magnet and armature of the lock doesn t align completely, please adjust them. (3) Maybe due to under voltage or wrongly jumped, please double check. D. Once powered, if the lock cannot attract immediately, then the reason could be as follows: (1) The time delay is too long, please shorten it by adjusting the knob counterclockwisely. (2) Maybe the time period which is controlled by the external controller (such as reader, etc..) is too long, please adjust the time period of external controller. Specifications subject to change without notice for further modification. 5 PG-1200RC

TEMPLATE TEMPLATE FOR FAS-PG-1200RC PLACE AGAINST HEADER (1/8") DRILL 3.2mm HOLE (2 PLACES) Drill 10mm hole for wring connection FOLD THIS DOTTED LINE L.H.R. DOOR INSTALLATION PLACE AGAINST DOOR (1/4") 6mm DIA.ARMATURE GUIDE PINS HOLE - 12.5mm DEEP (1/2") R.H.R. DOOR INSTALLATION (11/16") DRILL 16mm HOLE PG-1200RC