Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

Similar documents
Tester for Insulated Rail Joints SICO 2046 M A N U A L. 7 Technical Data. 7.1 General

Level Measuring Sensor for Diesel Fuel Tanks

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Ex m Solenoid Operator Type 0519

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Important instructions

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Solenoid Operator 0513 / 1213

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

KeContact P20. User manual

English. Instruction and operation manual S 212. Dew point sensor

c-go 24V/6A 24V/8A 24V/12A

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Solenoid Operator 0516 / 1216

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Certificate of Conformity self-generation unit

HST-BL-2830MS & HST-BL-2830MS-USA

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Heat Meter Integrator

KSZ 10B Current Probe Calibrator. Instruction Manual

Fuse state indicator MEg72. User manual

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 12

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

AXIAL FANS Axis / Tubo OPERATION MANUAL

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

Operating Instructions

Wind Power Inverter WINDY BOY 5000A/6000A

VISO Reference CALI-T50. User guide

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

DC Master 24/ A

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

GL1200T Cut & Seal. (GL1200 Seal only)

MANUAL. Single charger

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Switching DC Power Supply

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

KSZ 100B Current Probe Calibrator. Instruction Manual

Operating instruction and technical description

Mechanical Operating Instructions

Swing Piston Compressors and Vacuum Pumps

BODAS Pressure sensor PR3 series 10

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Technical Documentation

Slide Measuring Instrument GMG 200

Original Operating Manual

SITRANS P measuring instruments for pressure

INSTRUCTION MANUAL. Battery powered crimping tool SMART-LINE. Battery powered crimping tool SO-6M. Art /M. convincing solutions.

Table of Contents. Chapter 1 Product Summary... 2

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Actuators for air dampers and control valves of oil burners

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video

Mass Sine 24/10000 Mass Sine 24/15000

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Certificate of Conformity self-generation unit

User's Guide of BST-360 Battery System Tester. BST-360 Battery System Tester User's Guide 1 / 15

Operation Manual for Torque Sensors

ZB0050 / ZB0051 ZB0070 / ZB0071

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Instruction Manual. Revision no.: ENG-0001 FILON FUTUR S FILON FUTUR M

Multi-Mover Charger for model L25

Tina 11A Connection block

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

JBL VTX-V20-DF SUSPENSION MANUAL

Contamination switch VS

Udiag BST300 Battery Tester User Manual

Operating instructions ErgoPack 600 E

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

Safety Sensor CSS 180 Product Information

Battery powered cutting tool. AS6ST-20 Art convincing solutions. Video

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Instructions for Use Plain Trolley ULK Geared Trolley UHK

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Installation and Operating Instructions for ROBA -takt Switch Gear Type

Operating instructions Spray nozzle SDU

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Smart 110 with built-in flashlight for 6 240Ah lead-acid batteries

Electric Hi Lo Screen lift Trolley Mount 8960

Drive System Application

Tina 4A Connection block

Operating Instructions. Angle Seat Control Valve. Type 7020

Safety instructions. Always... Never... Fire hazard! Dear customer,

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

HST -LS Interlocking device (Translation of Original Manual)

English. Instruction and operation manual S 110. Power Meter

GL1200T Cut & Seal. (GL1200 Seal only)

Tina 10A/B/C Adaptor unit

Documentation. RM-BV4 Micro DP. Filter control

Compensation unit AGE-XY 50-80

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

ECONOMISER SERIES E2T USER MANUAL

Transcription:

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

8 Technical Data Operating temperature range 5 C 40 C Power supply 230 V, 50 Hz net Power input 25 W Protection degree IP 42 Protection class II Dimensions 280 x 140 x 240 mm Weight approx. 4 kg Dear customer, Thank you for choosing the Tester for Motor-driven Relays Type Siemens SICO 1225. You have purchased a high quality technical device for testing two- and three-layer motor-driven relays. We hope that all of your expectations are met and that we are able to support your work. This product was designed, produced and tested with due care and according to the applicable European Standards. If the device is yet not working correctly under the conditions given in this operating manual, please contact the manufacturer: Signal Concept GmbH Suedring 11 04416 Markkleeberg GERMANY Phone: ++49 (0) 34297 1439-0 Fax: ++49 (0) 34297 1439-13 E-mail: info@signalconcept.de Signal Concept GmbH confirms the conformity of the device according to the directives given by the European Parliament and Council 2004/108/EC (EMC-Directive), 2006/42/EC (Machinery Directive), 2006/95/EC (Low Voltage Directive), 85/374 EEC (Product Liability Directive), 2002/95/EC (RoHS Directive) and 2002/96/EC (WEEE Directive). Signal Concept GmbH holds a Quality Management (DIN EN ISO 9001:2008-12), which is checked annually by Bureau Veritas Quality International Deutschland GmbH as accredited organization. This manual serves as an introduction to your new device. Please read it carefully for your own protection. Furthermore, it enables you to use all functions properly. Please follow all directions and hints to avoid accidents with persons and damages of the device. The manual is part of the device. The user has to keep it until the disposal of the device. When handing the device to other users, the manual must be given too. Document No.: 1225 Version: 09/2010 Date: 30.09.2010 Copyright 2010, Signal Concept GmbH All rights reserved. All data, properties and descriptions given in this operating manual may be changed at any time without giving notice. 22 3

Accessory Included in the delivery are the following parts. Please check if all of these components were supplied. If parts are missing or damaged, please contact your reseller. Order number 1 Tester SICO 1225 100404 1 Control wire for motor-driven relay on request 1 Sensor cable on request 1 Power cable on request The test can be restarted by pressing the buttons "STOP" and then "START. If the above mentioned displays repeat for one and the same motor-driven relay, it is assumed that this motor-driven relay works irregularly. Therefore, it must not to be used anymore. 7.1.3 Automatic Shut-down Immediately After the Start If the device shuts down immediately after the start, avoid to restart the tester directly and do not press the start button over a longer time period. Check the motor-driven relay for e.g. winding and turn-to-turn faults. 1 Transport case 100402 1 Manual on request 1 Acceptance test certificate 3.1 on request 4 21

7 Notes Content 1. Put the motor-driven relay into a horizontal position before starting the test. 2. Connect the motor-driven relay with the switched-off tester. 3. If two or more contacts of a two-layer motor-driven relay are defective, then the display might show mistakenly "Dreilagenrelais" (three-layer motor-driven relay). In this case a trailing factor measurement will not be carried out. 4. For the tester, a 230 V, 50 Hz power supply voltage shall be used as power supply. Using the tester at places without a power supply is only permitted with a DC-AC Sinusalternating-current converter approved by the manufacturer. 5. The compliance of the tester with all safety instructions and with the accuracy of the measurements shall be checked every 12 months. These tests have to be carried out by the manufacturer or a company authorized by the manufacturer. 7.1 More Displays 7.1.1 Current Detection Display A: ABABABABABABABAB Causes: The track phase voltage has been switched off. The track phase current was not within the permissible range. The track phase coil might have e.g. a turn-to-turn fault or the control wire has been removed during the test. Display B: ABABABABABABABAB Causes: The auxiliary phase voltage has been switched off. The auxiliary phase current was not within the permissible range. The auxiliary phase coil might have e.g. a turn-to-turn fault or the control wire has been removed during the test. After the power supply monitoring has been activated, the tester can be restarted after a trouble shooting. 7.1.2 Comparison Display A: VGLABABABABABAB Causes: The inspection by the tester is interrupted. The trailing factors, which were calculated by the two processors within the tester, diverge from each other. Display B: XABABABABABAB Causes: The inspection by the tester is interrupted. The trailing factors, which were calculated by the two processors within the tester, diverge from each other. X names an error code between 0 and 255. Accessory...4 Content...5 1 Safety Instructions...6 2 Operation...7 2.1 Tester...7 3 Start-Up...8 3.1 Inspection Procedure...8 3.2 Two-Layer Motor-Driven Relay...8 3.2.1 Relay Type Identification...8 3.2.2 Contact Testing...8 3.2.3 Setting the Auxiliary Voltage...8 3.2.4 Sample Value Determination...9 3.2.5 Specification of Measuring Results...9 3.2.6 Display of Limit Attraction Voltage, Limit Trailing Voltage and Trailing Factor...9 3.2.7 Display of Limit Attraction Current and Limit Trailing Current...9 3.2.8 Display of "WECHSEL?" (switch over)...9 3.2.9 Button "WECHSEL" (switch over)...9 3.3 Three-Layer Motor-Driven Relay...10 3.3.1 Relay Type Identification...10 3.3.2 Contact Testing...10 3.3.3 Setting the Auxiliary Voltage...11 3.3.4 Sample Value Determination...11 3.3.5 Specification of Measuring Results...11 3.3.6 Display of Limit Attraction Voltage, Limit Trailing Voltage and Trailing Factor...11 3.3.7 Display of Limit Attraction Current and Limit Trailing Current...11 3.3.8 Display of "WECHSEL?" (switch over)...12 3.3.9 Button "WECHSEL" (switch over)...12 3.4 Button "STOP" (Two-layer and three-layer motor-driven relay)...12 3.5 Display "Abfallzeit >180 MS" (Trailing time > 180 MS; two-layer motor-driven relay)...12 4 Interpretation of Test Results...13 5 Test Assembly...14 6 Display Information A and B...15 6.1 Setting the Auxiliary Voltage and Identification of the Relay Type...15 6.2 Contact Testing Three-layer Motor-driven Relay / Measuring Auxiliary Phase Current 15 6.3 Contact Testing Two-layer Motor-driven Relay / Measuring Auxiliary Phase Current...16 6.4 Sample Value Determination of the Attraction and Trailing Factors...16 6.5 Specification of Measuring Results...16 6.6 Display of Current and Minimal Trailing Factor...17 6.7 Display of Track Phase Currents...18 6.8 Possibilities to Switch Over...18 6.9 Possibility to Switch Over or End of Inspection after 9 Measurements...18 6.10 Warning Due To "Sticking" during Trailing...19 7 Notes...20 7.1 More Displays...20 7.1.1 Current Detection...20 7.1.2 Comparison...20 7.1.3 Automatic Shut-down Immediately After the Start...21 8 Technical Data...22 20 5

1 Safety Instructions The Tester for Motor-driven Relay SICO 1225 is to be used exclusively according to the description in this manual. Otherwise, the protection given by the tester can be limited.! Warning! To avoid the damage of persons or products, mind the following guidelines: Do not use the testing unit if it is damaged. Check the housing before use. Check carefully the insulation around the socket of the power cord, the power switch and around the plug-in point for the control wire of the motor-driven relay. Check the power cord, the control wire of the motor-driven relay and the sensor wire for damages of the insulation. Replace damaged wires before using the testing unit. Do not use a power cord other than supplied with the testing unit. Never put any metal objects into the plug-in point of the testing unit for the control wire of the motor-driven relay or the plug-in point of the motor-driven relay control wire. Never unplug the sensor from the motor-driven relay. Never touch the sockets at the front of the motor-driven relay. Do not use the tester in environments with explosive gases, steam or dust. Do not use the tester when it shows a malfunction. The protective devices could be affected. In case of doubt send the tester to the manufacturer or to a company authorized by the manufacturer for checking. The manufacturer or a company authorized by the manufacturer are the only ones being responsible for repairing. High voltages occur at some parts inside the tester. For that reason do not start or run the tester while it is opened. Do not use a protection system other than stated for this testing unit. Qualified professionals only may use the tester. Do not drop or shock the tester. AFA = 0.78 MI = 0.76 MESSUNG 9 (measurement 9) AN = 15.9 AB = 12.1 V MESSUNG ZU ENDE (end of measurement) (Display B shown above alternates with the following.) 6.10 Warning Due To "Sticking" during Trailing AFA = MI = 0.78 MESSUNG 2 Abfallzeit >180 MS (trailing time) Disposal Electric and electronic devices must not be given to the general rubbish, since they mostly contain noxious elements. Instead, dispose them at the collecting points for special waste. 6 19

MI AN AB Minimum of the measured trailing factors for the connected motor-driven relay Limit attraction voltage of the track phase Limit trailing voltage of the track phase The displayed measuring results are not valid before they flash. 6.7 Display of Track Phase Currents AFA = 0.78 MI = 0.76 IAN = 11.6 MILLIA AN = 15.9 AB = 12.1 V IAB = 8.9 MILLIA AFA = 0.78 MI = 0.76 MESSUNG 2 2 Operation The tester may only be used for testing the following motor-driven relays by Siemens: Two-layer motor-driven relay Two-layer motor-driven relay Three-layer motor-driven relay Three-layer motor-driven relay Three-layer motor-driven relay Three-layer motor-driven relay 2.1 Tester V25437-A1001-A2 V25437-A1001-D2 V25437-B2001-B1 V25437-B2001-C1 V25437-C2001-A3 V25437-C2001-D3 The tester is the main part for the testing of motor-driven relays. It has two graphic displays which report instructions for the user, measurement data as well as warnings and failure notes. AN = 15.9 AB = 12.1 V IAN IAB Limit attraction current of the track phase Limit trailing current of the track phase 6.8 Possibilities to Switch Over AFA = 0.78 MI = 0.76 MESSUNG 2 AN = 15.9 AB = 12.1 V WECHSEL? (switch over?) 6.9 Possibility to Switch Over or End of Inspection after 9 Measurements AFA = 0.78 MI = 0.76 MESSUNG 9 (measurement 9) AN = 15.9 AB = 12.1 V WECHSEL? (switch over?) 18 7

3 Start-Up Preparation of the inspection according to the picture on page 14: Connect the motor-driven relay to the tester via the control wire of the motor-driven relay, Connect the motor-driven relay to the tester via the sensor wire at the front, and Connect the tester to the 230 V supply system and switch it on by the power switch on the back s right side. 3.1 Inspection Procedure The tester works automatically, recognizing if the test object is a two- or three-layer motordriven relay. Analyzing the stop position is realized by evaluating the contacts and by evaluating the sounds of the stop noise. To start the inspection press the red button "START" on the front panel. Then, the test runs automatically and may be followed on the LC display. Watch the relay during the testing procedure. The test steps are described below. 3.2 Two-Layer Motor-Driven Relay 3.2.1 Relay Type Identification The tester identifies the relay type automatically and shows "Zweilagenrelais (two-layer motor-driven relay) on display A. 3.2.2 Contact Testing A contact testing is carried out, whose results are shown on display A. All contacts are checked to see if they are closing properly. First, the relay is attracted to check if all normally open contacts are closing properly. Then, the relay is trailed to check if all normally closed contacts are closing properly. The contacts are named according to how they are led through at the 16-pole male multipoint connector on the relay s backside (e.g. "SCHLIE 4A-2A ZU"). If all contacts are ZU (closed), they are okay. AFA = MI = MESSUNG 1 (measurement 1) FEINMESSG LINKS (precision measurement left) AFA = MI = 0.78 MESSUNG 2 FEINMESSUNG (precision measurement) AFA = MI = 0.78 MESSUNG 2 FEINMESSG RECHTS (precision measurement right) AFA = MI = 0.78 MESSUNG 2 FEINMESSG LINKS (precision measurement left) 6.6 Display of Current and Minimal Trailing Factor AFA = 0.78 MI = 0.78 MESSUNG 1 (measurement 1) AN = 15.6 AB = 12.2 V 3.2.3 Setting the Auxiliary Voltage The auxiliary voltage is set to 130 V and the current is measured by means of the auxiliary voltage winding. Both are displayed on display B. Display B: UH IH Auxiliary phase voltage Auxiliary phase current 8 AFA AFA = 0.78 MI = 0.76 MESSUNG 2 AN = 15.9 AB = 12.1 V Current trailing factor 17

6.3 Contact Testing Two-layer Motor-driven Relay / Measuring Auxiliary Phase Current SCHLIE 4A-2A ZU UH = 130 V SCHLIE 5A-7A ZU OEFFNR 3B-2B ZU UH = 130 V OEFFNR 6B-7B ZU 6.4 Sample Value Determination of the Attraction and Trailing Factors 3.2.4 Sample Value Determination The attraction and trailing factors are determined by a special method. Display A shows ZZZZZZZZZZZZZZZZ". The number of Zs indicates the time remaining until the completion of determination. 3.2.5 Specification of Measuring Results The attraction and trailing factors are checked and adjusted if necessary. Display A shows "FEINMESSUNG" (precision measurement). 3.2.6 Display of Limit Attraction Voltage, Limit Trailing Voltage and Trailing Factor After completing the measurement specification, the trailing factor, the limit attraction voltage and the limit trailing voltage are displayed on display A (for the minimum of trailing factors). AFA = MI = MESSUNG 1 (measurement 1) ZZZZZZZZZZZZZZZZ Display A: AFA MI AN AB Current trailing factor Minimum of the measured trailing factors of the connected motor-driven relay Limit attraction voltage of the track phase for the minimum of trailing factors Limit trailing voltage of the track phase for the minimum of trailing factors 6.5 Specification of Measuring Results AFA MI AN AB Current trailing factor Minimum of the measured trailing factors for the connected motor-driven relay Limit attraction voltage of the track phase Limit trailing voltage of the track phase AFA = MI = MESSUNG 1 (measurement 1) FEINMESSUNG (precision measurement) AFA = MI = MESSUNG 1 (measurement 1) FEINMESSG RECHTS (precision measurement right) 3.2.7 Display of Limit Attraction Current and Limit Trailing Current The limit attraction current and the limit trailing current are displayed on display B. Display B: IAN IAB Limit attraction current of the track phase for the minimum of trailing factors Limit trailing current of the track phase for the minimum of trailing factors While the limit attraction current and the limit trailing current are displayed, you can extend the remaining time of the display by pressing the button "WECHSEL" (switch over). Press the button "WECHSEL" again to continue the test. 3.2.8 Display of "WECHSEL?" (switch over) The word "WECHSEL? (switch over) appears on display B. Different test steps are carried out depending if the button "WECHSEL" is pressed while the word "WECHSEL?" is on the display. 3.2.9 Button "WECHSEL" (switch over) Pressing "WECHSEL" (switch over) The inspection is repeated or continued beginning with chapter 3.2.4 Sample Value Determination. 16 9

The whole inspection is repeated excluding the relay type identification and the contact testing. This procedure applies in case of e.g. an external interference. No pressing of "WECHSEL" (switch over) By jerky, multiple turning-on a high track voltage, the motor-driven relay axle rotates in the slipping clutch, which is visualized with a red dot on the motor-driven relay axle. Afterwards, the inspection is continued with 3.2.5 Specification of Measuring Results. The trailing factor (AFA) is recalculated. The inspection continues until the word "WECHSEL?" appears on display B. As long as the button "WECHSEL" is not pressed, the test procedure Rotating motor-driven relay axle - Recalculating trailing factor - Displaying "WECHSEL" - is repeated 9 times. Display B shows the number of the active measurement. In the right upper corner of display A, the minimum of the measured trailing factors during the passed measurements appear. After the completion of the 9th measurement, display B shows "MESSUNG 9" (measurement 9) and below "WECHSEL?" (switch over?) and, in turn "MESSUNG ZU ENDE" (measurement over). The inspection has been completed. Press "WECHSEL" as long as it is shown on display B and the inspection is repeated or continued beginning with 3.2.4 Sample Value Determination. The test is restarted beginning with 3.2.1 Relay Type Identification by pressing the buttons "STOP" and then "START". 3.3 Three-Layer Motor-Driven Relay 3.3.1 Relay Type Identification The tester identifies the relay type automatically and displays "Dreilagenrelais" (three-layer motor-driven relay) on display A. 3.3.2 Contact Testing A contact testing is carried out, whose results are displayed on display A. All contacts are checked to see if they are closing properly. First, the relay is attracted with left rotation to check if the respective normally open contacts are closing properly. Then, the relay is trailed with right rotation to check if the respective normally open contacts are closing properly. Next, it is checked if the normally closed contacts are closing on trailing. The contacts are named according to how they are led through at the 16-pole male multipoint connector on the relay s backside (e.g. "SCHLIE 4A-2A ZU"). If all contacts are ZU (closed), they are okay. 6 Display Information A and B 6.1 Setting the Auxiliary Voltage and Identification of the Relay Type UH IH DREILAGENRELAIS (three-layer motor-driven relay) UH = 126 V ZWEILAGENRELAIS (two-layer motor-driven relay) Auxiliary phase voltage Auxiliary phase current UH = 126 V 6.2 Contact Testing Three-layer Motor-driven Relay / Measuring Auxiliary Phase Current SCHLIE 5A-7A ZU UH = 130 V SCHLIE 6B-7B ZU SCHLIE 4A-2A ZU UH = 130 V SCHLIE 3B-2B ZU OEFFNR 4B-5B AUF UH = 130 V OEFFNR 3A-6A AUF Displayed is the three-layer motor-driven relay without back contact (V25437-B2001-B1; V25437-B2001-C1) As the 4-pin three-layer motor-driven relays V25437-B2001-B1 and V25437-B2001-C1 do not have any normally closed contacts, those normally closed contacts will always be evaluated as "AUF" (open; see 6.2 Contact Testing Three-layer Motor-driven Relay / Measuring Auxiliary Phase). 10 15

5 Test Assembly 3.3.3 Setting the Auxiliary Voltage The auxiliary voltage is set to 130 V and the current is measured by means of the auxiliary voltage winding. Both are shown on display B. Display B: UH IH Auxiliary phase voltage Auxiliary phase current 3.3.4 Sample Value Determination The word "WECHSEL?" (switch over) appears on display B before the sample value determination begins. The left rotation test (when attracting) starts by pressing "WECHSEL" while the word appears on display B. The test starts with a right rotation (attraction) if "WECHSEL" is not pressed. The attraction and trailing factors are determined by a special method. Display A shows ZZZZZZZZZZZZZZZZ". The number of Zs indicates the time remaining until the completion of determination. 3.3.5 Specification of Measuring Results The attraction and trailing factors are checked and adjusted if necessary. Display A shows "FEINMESSG RECHTS" (precision measurement right) or when rotating to the left "FEINMESSG LINKS" (precision measurement left). 3.3.6 Display of Limit Attraction Voltage, Limit Trailing Voltage and Trailing Factor After completing the measurement specification, the trailing factor, the limit attraction voltage and the limit trailing voltage appear on display A (for the minimum of trailing factors). Display A: AFA MI AN AB Current trailing factor Minimum of the measured trailing factors of the connected motor-driven relay Limit attraction voltage of the track phase for the minimum of trailing factors Limit trailing voltage of the track phase for the minimum of trailing factors 3.3.7 Display of Limit Attraction Current and Limit Trailing Current The limit attraction current and the limit trailing current appear on display B Display B: IAN IAB Limit attraction current of the track phase for the minimum of trailing factors Limit trailing current of the track phase for the minimum of trailing factors While the limit attraction current and the limit trailing current are displayed, you can extend the remaining time of the display by pressing the button "WECHSEL" (switch over). Press the button "WECHSEL" again to continue the test. 14 11

3.3.8 Display of "WECHSEL?" (switch over) The word "WECHSEL? (switch over) appears on display B. Different test steps are carried out depending if the button "WECHSEL" is pressed while the word "WECHSEL?" appears on the display. 3.3.9 Button "WECHSEL" (switch over) Pressing "WECHSEL" in chapter 3.3.8 Display of "WECHSEL?" After the testing with right rotation follows testing with left rotation and vice versa. Afterwards the inspection continues with 3.3.4 Sample Value Determination. No pressing of "WECHSEL" The inspection repeats 3.3.5 Specification of Measuring Results or continues. There will be no change in the rotation of the motor-driven relay. The trailing factor (AFA) is recalculated. The inspection continues until the word "WECH- SEL?" appears on display B. As long as the button "WECHSEL" is not pressed, the test procedure Sample value determination - Recalculating trailing factor - Displaying "WECHSEL" - is repeated 9 times. After the completion of the 9th measurement, display B shows in its right upper corner "MESSUNG 9" (measurement 9) and below "WECHSEL?" (switch over) in turn with "MES- SUNG ZU ENDE" (end of measurement). The inspection has been finished. Press "WECHSEL" as long as it is shown on display B and the inspection is repeated or continued beginning with 3.3.4 Sample Value Determination. The rotation direction of the motordriven relay changes. The test is restarted beginning with 3.3.1 Relay Type Identification by pressing the buttons "STOP" and then "START". 3.4 Button "STOP" (Two-layer and three-layer motor-driven relay) 4 Interpretation of Test Results The aim of the test is to obtain those data, which are required by the inspection sheet of the motor-driven relay. These are Auxiliary phase voltage, Auxiliary phase current, Limit attraction voltage of the track phase, Limit attraction current of the track phase, Limit trailing voltage of the track phase, Limit trailing current of the track phase, and Trailing factor. Most important is the determination of the trailing factor. If a relay has a trailing factor of less than 0.65 1, it is not secure that the track circuit always generates a consistent occupy message until the next inspection within one year. Therefore, several measurements or the test steps specification of measuring results (display "FEINMESSUNG" = precision measurement) should always be carried out to determine the trailing factor. The lowest trailing factor is valid. If the displayed minimum value exceeds 0.70 2, at least 3 measurements shall be taken. If the displayed minimum value is less than 0.70 2, at least 5 measurements shall be taken. The number of measurements taken equals the number of test steps specification of measuring results. Note: Variations in the trailing factor of 0.05 for the same motor-driven relay are to be considered as normal. When testing a relay, which was not used over a longer period of time, the trailing factor measured at first may be slightly lower. These measurements results may be ignored. When using the relay in a track circuit, it is ensured that it is used at least every 24 hours. The test can be cancelled at any time by pressing the button "STOP". The displays show the content as it was at the time of cancelling. The test can be restarted beginning with 3.2.1 or 3.3.1 Relay Type Identification by pressing the red button "START". 3.5 Display "Abfallzeit >180 MS" (Trailing time > 180 MS; two-layer motor-driven relay) At the end of 3.2.5 Specification of Measuring Results, the trailing time of the motor-driven relay is measured and compared to the nominal value of 180 ms. Using this method, a potential "sticking" of the motor-driven relay might be detected. If the nominal value was exceeded, display A shows "Abfallzeit >180 MS" (trailing time >180 MS). 12 1 This value applies for Deutsche Bahn AG. For information on exceptions, which may affect other users, please refer to the adjusting guidelines of the respective track circuits. 2 This value applies for Deutsche Bahn AG. For exceptions, which may affect other users, the following applies: If the displayed minimum value exceeds the minimum trailing factor +0.05, at least 3 measurements shall be taken. If the displayed minimum value is less than the minimum trailing factor +0.05, at least 5 measurements shall be taken. 13