WHITE PAPER. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels

Similar documents
WHITE PAPER. Detecting Rolling Element Bearing Faults Using the Echo Wireless Vibration Monitoring System

WHITE PAPER. Driveshaft/Axle On-track Torque Measurement Continuous high speed torque measurements for vehicle performance testing.

Load Cells. For Test, Measurement, and Monitoring Requirements in Automotive, Aerospace, R&D, and Process Control Applications

Model 378B02. ICP Microphone System. Installation and Operating Manual

Model 102B15. ICP Pressure Sensor. Installation and Operating Manual

Model B STRAIN GAGE LOAD CELL. Installation and Operating Manual

Model 377B10. Condenser Microphone. Installation and Operating Manual

Model 070A80. Front Panel Display. Installation and Operating Manual

Model 622B01. Industrial ICP Accelerometer. Installation and Operating Manual

Model M B. Strain Gage Load Cell. Installation and Operating Manual

DYNAMIC ICP PRESSURE SENSORS

Model 086C05. Installation and Operating Manual

Model 134A24 Tourmaline ICP pressure bar, 1000 psi, 5 mv/psi, 0.2 microsecond rise. Installation and Operating Manual

Sensors for Road Load Measurements Accelerometers, Pressure Sensors, Force Sensors, Strain Sensors, Load Cells, and Signal Conditioners

SWIFT Evo SPINNING WHEEL INTEGRATED FORCE TRANSDUCER

Air Bearing Shaker for Precision Calibration of Accelerometers

Special edition paper

Model 393B31. Seismic, high sensitivity, ceramic flexural ICP accel., 10 V/g, 0.1 to 200 Hz, Installation and Operating Manual

Development of a weatherproof windscreen for a microphone array

Energy Density Active Noise Control in an Earthmoving Machine Cab

Vehicle Aerodynamics Subscription Development of Numerical Simulation Method of Flow Around Automobile Using Meshfree Method

Passenger Vehicle Interior Noise Reduction by Laminated Side Glass. Abstract

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Interior Acoustics. Lecture delivered by: Kiran V. R. Asst. Prof. Dept. of AAE MSRSAS-Bangalore. M.S Ramaiah School of Advanced Studies - Bangalore

Introduction to Gulfstream Aerospace and Acoustics Activities

Interior Duct Wall Pressure Downstream of a Low-Speed Rotor

Reductions in Multi-component Jet Noise by Water Injection

A Different Approach to Gas Turbine Exhaust Silencing

Effect of Shock Induced Acoustic Emission and Shock Waves Impact on Polyurethane Foam

Prof. João Melo de Sousa Instituto Superior Técnico Aerospace & Applied Mechanics. Part B Acoustic Emissions 4 Airplane Noise Sources

Vibration, and Sound Quality

Acoustic design of the air transparent soundproofing wall

Motorsport Sensors

APMP TCAUV Workshop The application of acoustics, vibration and ultrasound metrology in transportation industry

1 American Institute of Aeronautics and Astronautics

AE3051 Experimental Fluid Dynamics TRANSIENT MEASUREMENTS IN A SHOCK TUBE

Unerwünschtes strömungsinduziertes Pfeifen von Ladeluft-Resonatoren von der Theorie über die Messung und Simulation zur Lösung

Application of Combustion Sound Level (CSL) Analysis for Powertrain NVH Development and Benchmarking

Brüel & Kjær and LDS The Perfect Match SHORT FORM CATALOGUE

VALMONT MITIGATOR TR1

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Industrial Monitoring Instrumentation

AUTOMOTIVE TESTING AND OPTIMIZATION. Tools for designing tomorrow's vehicles

Noise Emissions At the Chicago Fuller Car Wash

An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices

Ground Effect and Turbulence Simulation at the Pininfarina Wind Tunnel. Giuseppe Carlino Aerodynamic and Aeroacoustic Research Center

CASE STUDY. 50 Years of Technological Innovation. Blachford Inc. Automotive NVH Testing. United States of America. Automotive

Silencers. Transmission and Insertion Loss

FLIGHT TEST RESULTS AT TRANSONIC REGION ON SUPERSONIC EXPERIMENTAL AIRPLANE (NEXST-1)

Pressure Sensors for Test and Measurement. For Precise Pressure Measurement in Static and Dynamic Applications

Introduction to vehicle NVH and Acoustics

NUMERICAL STUDY OF TRANSFER FUNCTION OF COM- BUSTION NOISE ON A HEAVY DUTY DIESEL ENGINE

STUDY OF FEASIBILITY OF PLASTIC GEAR TO REDUCE NOISE IN A GEAR PUMP

CAR ENGINE CATALYTIC COLLECTOR NOISE REDUCTION

Muffler size minimization, using attenuation behaviour by acoustic simulation

Piezoelectric, Quartz Pressure Sensors for Dynamic Pressure Measurements

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

TOTAL CUSTOMER SATISFACTION GUARANTEED

Minimizing Noise. Marybeth G. Nored Dr. Klaus Brun Eugene Buddy Broerman Augusto Garcia Hernandez Dennis Tweten. Southwest Research Institute

Deployment and Drop Test for Inflatable Aeroshell for Atmospheric Entry Capsule with using Large Scientific Balloon

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc.

PRODUCT RELIABILITY TESTING: Environmental, Mechanical and Packaging Case study: 19 Rackmount Switch

Reciprocating compressor diagnostics

Prediction of exterior sound field of an automotive for airborne excitation and transmission to the interior of the vehicle

Condition Monitoring of a Check Valve for Nuclear Power Plants by Means of Acoustic Emission Technique

Vibration Analysis of Car Door Using FE and Experimental Technique

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

HEAVY-DUTY ARTICULATED 500,000-MILE BUS WITH A MINIMUM SERVICE LIFE OF 12 YEARS 7.1 INTERIOR NOISE TESTS

FINAL REPORT MARCH 2008

Sound Application Guide: Description and Ratings

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

Large Low-speed Facility (LLF)

Chapter 7: Basic Vibration Control: Reduction at source (Part III)

CASE STUDY. A World Leader in a Niche Market. PAPST Fans Testing and Development of Automotive Fans. Germany. Automotive, Industrial, Consumer

DaimlerChrysler Alternative Particulate Measurement page 1/8

AUTHORS MOTIVATION. Robert Powell is Director Structural Acoustics at Exa Corp. in Burlington, Massachusetts (USA).

Abstract INTRODUCTION

Experimental investigation of high airflow rate ventilation system with improved noise performance by passive and active means

MEASUREMENT AND EVALUATION OF CAM CHAIN NOISE AND VIBRATION OF MOTORCYCLE ENGINE. A thesis

Total Noise Analysis of a Directional Drill

Analytical Prediction of Ride in Car Cabin from Virtual Rough Road. Arvind K Jain, Amol Patil, Vaibhav Kaka, Indranil Bhattacharya

Model 643A ma Output Velocity Sensor. Installation and Operating Manual

Rehabilitated PCC Surface Characteristics

Model 648A ma Output Accelerometer. Installation and Operating Manual

Seeing Sound: A New Way To Reduce Exhaust System Noise

Sulastic Rubber Springs

Design, Construction and Testing of a Desktop Supersonic Wind Tunnel

Computational Fluid Dynamics in Torque Converters: Validation and Application

pressure transducer Miniature pressure transducer model 81530

EMaSM. Principles Of Sensors & transducers

Sensors for hybrid power generation system

Experiments in a Combustion-Driven Shock Tube with an Area Change

INTERIOR NOISE OF A KOREAN HIGH-SPEED TRAIN IN TUNNELS

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 2.114

Calibration and Demonstration of the New Virginia Tech Anechoic Wind Tunnel

CASE STUDY. History. Liebherr-Werk Ehingen GmbH EU Directive Compliance, R& D Testing. Germany. Automotive. PULSE, Transducers

Transcription:

Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Andrew R. Barnard, Ph.D., INCE Bd. Cert. Assistant Professor, Mechanical Engineering Engineering Mechanics Michigan Technological University WHITE PAPER Energy & Power Generation visit us online at www.pcb.com Toll-Free in USA 800-828-8840 716-684-0001

Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Andrew R. Barnard, Ph.D., INCE Bd. Cert. Assistant Professor, Mechanical Engineering Engineering Mechanics Michigan Technological University Introduction Have you ever tried to make sound measurements with wind blowing over the microphone? If so, you have probably noticed that the measured sound pressure levels from microphones are affected greatly by the presence of air flow across the microphone diaphragm. The dynamic pressure field measured by the microphone in these cases includes both the acoustic pressure and the pressure induced by the air flow. Wind tunnel noise measurement is a common application in the aerospace and automotive industry where this effect is prevalent. Wind tunnels are used by Aerodynamic Engineers to test aircraft, rocket and automobile models. Using acoustic data gathered from a scale- model in a wind tunnel, the test engineer can estimate the total noise radiation from a full- scale vehicle or component. This can be done over the entire operating speed range of the vehicle at far lower cost than full- scale in- situ measurements. Additionally, panel testing and interior cabin noise measurements are common applications. Aerospace or automotive engineers will mount microphones outside a moving vehicle to measure noise while the vehicle is in operation. Atmospheric wind noise effects are also very common in environmental noise measurements, for example clear air turbulence (CAT) and other severe weather (tornado or hurricane) detection. So how do we isolate the acoustic field from the air flow pressure to make accurate acoustic measurements? There are three types of microphone accessories that are commonly used to perform this isolation: grid- caps, windscreens, and nose- cones. Microphones can be placed at any angle with respect to the flow direction. However, the most common orientations have the microphone diaphragm either facing the flow head- on, or parallel to the average flow direction. There are also two types of flow fields: laminar and turbulent. In a laminar flow field, the air flows in parallel layers without disruptions. Think of this as smooth flow. In turbulent flow, there are many turbulent eddies, or chaotic changes in flow direction, throughout the flow field. Think of this as a rough flow. In addition to microphones placed in the flow, it is also possible to flush- mount a microphone on a surface. Two types of flush mounted microphones are surface- mounted and side- vented microphones. Side- vented microphones are designed to mounted through a wall; whereas, surface- mounted microphones to not require any alteration to the measurement surface. Surface microphones are always located in a turbulent flow due to the boundary layer characteristics of the flow and their diaphragms are usually oriented parallel to the flow direction. The objective of this paper is to show experimentally which microphones and accessories are best used for a given application based on the type of flow and the microphone orientation. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 2

Wind Tunnel Experiments There are many types of wind tunnels designed for different purposes, generally identified by their operating speed range. Wind tunnels can be classified by their Mach number, the ratio of the air speed in the test section to the speed of sound. Typical wind tunnel classifications are subsonic (M <.8), transonic (.8 < M < 1.2), supersonic (1.2 < M < 5.0), or hypersonic (M > 5.0). An experiment was conducted in the Penn State Aerospace Engineering subsonic wind tunnel facility using both ½ and ¼ microphones mounted in the flow field and on the boundary surfaces. The wind tunnel facility is a quiet wind tunnel; however, the test section is not anechoic. There are noise abatement treatments on the turning vanes of the wind tunnel to minimize the amount of fan noise that is present in the test section. The background noise sound pressure level inside the test section at 0 mph is less than 20 db in a frequency band from 250 Hz to 20 khz. Care was taken during the measurements to ensure that no spurious sounds from adjoining laboratories affected the results. The wind tunnel was set to 0, 10, 25, and 55 mph flow speeds in order to evaluate the effects of the microphone accessories. A speaker was placed upstream of the microphones to simulate a sound source. Two types of surface- mount microphones were evaluated to observe how their background noise level increased with flow speed. All microphones and accessories were manufactured by PCB Piezotronics. The microphones were all precision, prepolarized condenser microphones with ICP powered preamplifiers. Table 1 lists the microphones and accessories used in this study and Table 1 shows the overall setup of the microphones within the wind tunnel. Figure 2 shows the microphone orientations and the device used to create turbulence in the wind tunnel near the microphones. Table 1. Description of PCB microphones and accessories used in this study with noted orientation. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 3

Figure 1. Setup configuration of the wind tunnel showing the relative locations of the 10 microphones and the speaker. The speaker was mounted to the opposite wall of the wind tunnel as compared to the 378A14 microphones. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 4

Figure 2. Microphones shown mounted in the wind tunnel in the head- on (left) and parallel (right) orientation, with (lower) and without (upper) the turbulence generator. Flow direction is into the page. Lowering the System Noise Floor Using Microphone Accessories Background noise spectra were recorded in one- third- octave (OTO) bands with the wind tunnel speed set to values of 0, 10, 25, and 55 mph. The measured noise spectra at non- zero speed conditions with windscreens and nose- cones were subtracted from the non- zero speed flow noise spectra measured with only a grid- cap. This results in an apparent decrease in the measurement noise floor of the system when using the accessories. Figure 3 and Figure 4 show the decrease in the system noise floor when using the windscreen or nose- cone accessories with respect to only a grid- cap in the head- on and parallel orientation, respectively. Data are presented for both the laminar and turbulent flow regimes, at three speeds, and for two different Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 5

microphone types (½ and ¼ free- field condenser microphones). The nose- cone accessory was not used in the parallel orientation as that is not its intended use case. It is shown that the accessories can give up to a 30 db decrease in the system noise floor in either orientation. As the flow speed increases, the noise floor reduction benefit offered by the accessories extends to higher frequencies. This is because the turbulent boundary layer is excited at higher frequencies with increasing flow speed. In turbulent flow, the windscreen is more effective than the nose- cone at reducing the measurement noise floor. In laminar flow, at these speeds, the windscreen and the nose- cone accessories are nearly equal in their ability to lower the noise floor. It is suspected that in much higher flow speeds than those measured here the nose- cone would be more advantageous than the windscreen due to the fact that it is more robust. Figure 3. Difference in flow noise between the grid- cap configuration and the windscreen or nose- cone configurations. Data are shown at head- on incidence angle in laminar and turbulent flows for 10, 25, and 55 mph speeds Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 6

Figure 4. Difference in flow noise between the grid- cap configuration and the windscreen configuration (the nose- cone configuration is not meant for use in the parallel orientation). Data are shown at parallel incidence angle in laminar and turbulent flows for 10, 25, and 55 mph speeds. Although windscreens can reduce flow noise, windscreens can also introduce an insertion loss into your measurement system. That is to say, some small portion of the acoustic energy is absorbed in the foam windscreen prior to the pressure wave arriving at the microphone diaphragm. This may slightly lower the sound pressure levels that are measured, so it is important to characterize the insertion loss of the windscreen up front, even though it is usually small. In a separate experiment, two microphones (PCB 378B02 and PCB 378C01) were placed in a stationary acoustic field in a reverberant chamber and data were recorded with and without the windscreens present. The data in Figure 5 show that for these windscreens, the insertion loss is from 0- to- 2 db, and varies with frequency. This type of data should be recorded for each windscreen, as the insertion loss may vary slightly from part- to- part. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 7

Figure 5. An example of an insertion loss measurement using a ¼ and ½ microphone in a reverberant chamber. The data show slightly increased insertion loss due to the ¼ windscreen (left). Photos of the experiment are shown without windscreens (upper right) and with windscreens (lower right). Examples of Noise Floor Measurements Using Surface Mount Microphones Two types of surface mount microphones were also evaluated, a side- vented pressure microphone mounted through the wind tunnel wall, and a low profile surface microphone adhered to the tunnel floor with manufacturer- provided tape rings. Since these are surface mounted microphones, they are always located in the turbulent boundary layer, so no laminar flow data is reported. Representative turbulent flow noise background spectra were recorded, and are shown in Figure 6. The narrowband peaks that exist in this data (for example at 315 Hz in the 55 mph data) should be ignored, as they are resonance characteristics of the particular facility, and not related to the broadband flow noise floor of the microphone. It should also be noted that the high frequency noise floor of this measurement (~28 db) is the noise floor of the facility, and not of the microphones. The noise floor of the side- vented pressure microphone is much lower, 25-30 db at some frequencies, than that of the low profile surface microphone at all flow speeds. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 8

Figure 6. Background flow noise spectra at 0, 10, 25, and 55 mph. The black, 0 mph, curves represent the absolute noise floor of the wind tunnel. Two curves are present for each speed representing each of two microphones placed near each other. Note that narrow peaks in these spectra are due to resonant behavior of the wind tunnel at specific frequencies. Example: Measuring A Known Signal In Flow Noise Finally, the speaker source was used to demonstrate how the windscreen and nose- cone accessories can be used to measure a signal with very low signal- to- noise ratio, see Figure 7. The noise source spectrum is shown as the black curve in all plots. It is a bandpass white noise signal between 1 and 5 khz in frequency with sound pressure level of approximately 60 db in each one- third- octave band. For this source, using a ¼ microphone, the signal would not be measureable in either orientation without a windscreen or a nose- cone accessory (left graphs in Figure 7). The ½ microphone in the head- on orientation may be able to detect the signal with only the grid- cap (top- right graph in Figure 7); however, much better results are obtained when the windscreen or nose- cone are used. The ½ microphone in the parallel configuration requires a windscreen in order to measure this signal with any degree of accuracy (bottom- right graph in Figure 7). Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 9

Figure 7. Low level sound source plus flow noise at head- on (top) and parallel (bottom) incidence angle in 55 mph laminar flow comparing grid- cap, windscreen, and nose- cone accessories. Recommendations: Which Microphones and/or Accessories Should You Choose? When a microphone is to be located within the flow field, it is recommended as best practice that a windscreen or nose- cone accessory always be used when taking acoustic measurements. In head- on laminar flow, the nose- cone accessory is the best choice. In all turbulent flow and parallel orientation laminar flow, the windscreen accessory is the best choice. The microphone diameter should be selected based on the desired total system noise floor and frequency response requirements, since the windscreen and nose- cone accessories are equally as effective, regardless of microphone size. When selecting surface mounted microphones, the side- vented pressure microphone is a better selection, with respect to noise floor, than the low profile surface microphone. However, in order to surface mount the side- vented pressure microphone, a hole must be bored in the test structure. In cases where non- destructive Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 10

test is required, the low profile surface microphone is a good choice. Table 2 summarizes the use cases for the microphones and accessories tested in this study. Table 2. Recommended microphones and accessories based on flow conditions and mounting conditions for the PCB instrumentation evaluated in this study. Flow Induced Noise Reduction Techniques for Microphones in Low Speed Wind Tunnels Page 11

WHITE PAPER What are divisions of PCB Piezotronics? PCB Piezotronics, a member of the PCB Group families of companies, has five major divisions, all of which offer targeted sensor technologies. These divisions are supported by an active outside direct sales force of Field Application Engineers, as well as international direct sales offices throughout the world. Individual PCB Piezotronics divisions, locations and their primary product specialties include: Depew, NY, USA - www.pcb.com Piezoelectric, ICP, piezoresistive & capacitive pressure, acoustic, force, torque, load, strain, shock & vibration sensors. Depew, NY, USA - www.pcb.com/aerospace Sensors & Instrumentation for aerospace & defense applications, including air and spacecraft testing. Novi, MI, USA - www.pcb.com/auto Sensors & Instrumentation for automotive testing, including modal analysis; NVH; component durability; powertrain testing; vehicle dynamics; safety and regulatory testing. Depew, NY, USA - www.imi-sensors.com Industrial vibration sensors, bearing fault detectors, mechanical vibration switches, panel meters, cables & accessories for predictive maintenance and equipment protection. Depew, NY & Provo, UT, USA www.larsondavis.com Precision microphones, sound level meters, noise dosimeters, audiometric calibration systems. MEMS AdvAncEd design center San Clemente, CA, USA - www.pcb.com Research & development engineering center for special technologies. Seattle, WA, USA - www.pcb.com Process development and fabrication of MEMS sensors. Farmington Hills, MI, USA - www.pcb.com/loadandtorque Designs and manufactures high quality, precision load cells, wheel force transducers, torque transducers, telemetry systems, and fastener torque-tension test systems. PCB Group Companies: DYNAMIC METROLOGY Cincinnati, OH, USA - www.modalshop.com Global leader in dynamic calibration offering a complete line of automated calibration systems and recalibration services to support dynamic vibration, pressure and force sensors in applications such as: national standards, commercial labs, government/military research, consultancies, and industrial/plant floor operations. Rochester, NY, USA - www.sti-tech.com Mechanical engineering consulting firm specializing infinite element analysis, advance analytical techniques, experimentation, technology development, &design optimization for turbo machinery, industrial machine systems & mechanical structures. Toll-Free in USA 800-828-8840 n 24-hour SensorLine SM 716-684-0001 E-mail info@pcb.com n www.pcb.com ISO 9001 Certified n AS9100 Certified n A2LA Accredited to ISO 17025