PowerCube type PB series A complete solution for OEMs

Similar documents
Air-insulated switchgear UniGear type ZS1

PowerCube type PB. Pre-assembled modules and enclosures for constructing medium voltage switchgear

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

Metal Clad Switchgears

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

UniGear. Technical Guide

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Current accuracy class. Sensor principles

Power IT Air Insulated Cubicle Uniswitch

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

MESG 12 / 17.5 / 24 / 36 KV

Air-insulated medium-voltage secondary distribution switchgear

UniGear type ZS1. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Unitole UP kv Primary substations Motor control centres

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Gas Insulated Metal-clad Switchgear, HMGS!

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

the safe, reliable, and efficient choice for MV switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

VD4 Installation and service instructions kv A ka

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

PIX-H Metal-clad switchgear up to 17.5kV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Unitole UP kv Primary substations Motor control centres

Contactor V-Contact VSC/P

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

with Vacuum Circuit Breaker HAF

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

ZX-Family Gas-insulated medium voltage switchgear

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

Medium Voltage Products. SHS2 Gas-insulated switching and isolating apparatus

Metal Clad Air Insulated Switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

Benefits, typical uses

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure


A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Modular medium-voltage switchgear. NorMax

Unified requirements for systems with voltages above 1 kv up to 15 kv

HD4. Gas insulated MV circuit-breakers kv A ka

Metal Clad VCBs ~ Mk1

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

Vacuum Circuit Breaker

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

UniSafe 36 Product Presentation. ABB Elektrik Sanayi A.S. - Page 1

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

Extensible Unit - VCE2a

Eilat, 11/2017. Cost Effective switchgear Modernization solutions

COMPACT SUBSTATION GUIDE

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Medium Voltage Metal-Enclosed Switches

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

ZX2 Gas-insulated medium voltage switchgear

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

KD LV Motor Protection Relay

Gas Insulated Switchgear

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

UniSec Operation and maintenance manual

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

SafeGear TM Motor Control Center Arc resistant metal-clad construction

NXPLUS C Single busbar. Maintenance-free for lifetime

33KV INDOOR SWITCHGEAR

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

HD4. Gas insulated MV circuit-breakers kv A ka

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Transcription:

Preliminare july 2006 series A complete solution for OEMs IndustrialIT TM ABB PT Dalmine 1VCP000093 Rev.C, it Presentation 2004.07

QUALITY SYSTEM Certification ISO 9001-2000 ENVIRONMENTAL MANAGEMENT SYSTEM Certification ISO 14001 ABB - Page 2

It is the main component of the switchgear and it is available in three different configurations all fitted, on request, with earthing switch: Modules type PB/M PB/RM Enclosures type PB/E PB/RE Mounting frame type PB/F ABB - Page 3 PowerCube are developed in order to allow development of switchgears according: IEC 62271-200 classification LSC2B-PM IAC BFLR or LSC2B-PM AFLR (which has replaced the previous classification of metal clad switchgears).

ABB - Page 4 Modules type PB/M Includes: Circuit breaker / Contactor compartment Cable access compartment Pre-assembled and pre-tested safety interlocks On request: VT compartment with VT truck (for cable access compartment) Earthing switch with making capacity Modules type PB/RM Includes: Cable access compartment Pre-assembled and pre-tested safety interlocks On request : VT compartment with VT truck (for cable access compartment) Earthing switch with making capacity They represent the ideal solution for OEM who need to realize single level switchgears with high level of standardization without high development costs and with a power part that includes, on request, measurement unit.

Enclosures type PB/E Includes: Circuit breaker / Contactor compartment Pre-assembled and pre-tested safety interlocks On request: Earthing switch with making capacity Enclosures type PB/RE Includes: Pre-assembled and pre-tested safety interlocks On request : Earthing switch with making capacity They represent the ideal solution for OEM who need to realize double level switchgears and maximum flexibility in the switchgear development. ABB - Page 5

Mounting frame type PB/F Includes: Fix contacts and shutter kinematic system Necessary components to rack-in/out the Circuit breaker / Contactor Pre-assembled and pre-tested safety interlocks On request: Earthing switch with making capacity They represent the ideal solution for OEM who need to use ABB apparatus in their own switchgear o to develop retrofit solutions. Versatility of use and the availability of an earthing switch with making capacity are strong points of this solution. ABB - Page 6

PowerCube: PERFORMANCES (according, where applicable, IEC 60298 / IEC 62271-200 standards) ABB - Page 7 PB/M PB/E PB/M PB/E PB/F PowerBox Module PB1 PB2 PB3 PB4 PB5 PB6 PB1/R PB2/R PB3/R PB4/R PB5/R PB6/R Module width mm 600 750 1000 750 1000 1000 600 750 1000 750 1000 1000 Rated voltage 12 kv 17,5 kv 24 kv 36 kv Test voltage 28 kv at industrial frequency 38 kv 50 kv 70 kv Impulse withstand 75 kv voltage 95 kv 125 kv 170 kv Short-time 25 ka (3s) (1) (1) (1) (1) withstand current 31,5 ka (3s) 40 ka (3s) 50 ka (1s) (1) (1) (1) (1) Peak current 63kA 79 ka 100 ka 125 ka Rated currents 630 A 1250 A 1600 A 2000 A 2500 A (2) (2) 3150 A 3600 A 4000 A (2) (2) (1) 1sec on the earthing switch (2) With forced ventilation per 4000A it is necessary to install, customer care, a second fan (supplied as a spare component) in the rear part of the switchgear.

/E STRUCTURE ABB - Page 8

/M Module structure 1 2 CB compartment Feeder compartment Circuit Breaker/ Contactors Service trucks 1 Terminals 1 2 Metallic shutters ABB - Page 9 2 * Not available on PB1,PR1 VT compartment (on request*) Earthing Switch (on request) Fan (for 12-17kV 3600-4000A and 24kV 2500A only)

/E Enclosure structure Circuit breaker/contactor/service truck Terminals Fan (for 12-17kV 3600-4000A and 24kV 2500A only) Metallic shutters ABB - Page 10 Earthing switch (on request)

/F Mounting frame Structure Metallic Shutters Terminals ABB - Page 11 Earthing switch (on request)

DESIGNED TO COVER A WIDE RANGE OF TYPICAL UNITS PB1 PB2 PB3 PB4 PB5 PB1R PB2R PB3R PB4R PB5R Module width mm 600 750 1000 750 1000 600 750 1000 750 1000 Incoming feeder IF incoming feeder with measurement IFM Riser R Measurement M Bus tie BT Bus tie with measurement BTM Direct incoming feeder IFD PB/E PB/F Units IFM, M, BTM with VT in fixed execution at customer care. ABB - Page 12

Cable area is easily accessible from the front (by disassembling circuit breaker compartment floor). ABB - Page 13

Earthing switch On request With making capacity Operative mechanism interlocked with circuit-breaker position. (1) Key lock on request (2-3) (2) Open Close (1) The earthing switch can be closed only if the circuit breaker is in racked-out position and it is not possible to rack in the circuit breaker if the earthing switch it is not in open position ABB - Page 14 (3) Rated voltage [kv] 12 17.5 24 Short time withstand current (3sec) [ka] 31,5 up to 50 (*) 31,5 Up to 50 (*) 25 Making capacity [kap] up to 125 Up to 125 Up to a 63 (*) 40-50kA for 1sec (not available on PB/F) (2) Key lock with free key when the earthing switch is in open position (3) Key lock with free key when the earthing switch is in close position

TERMINALS TYPE: UP TO 2500A : FLAT TERMINALS DESIGNED TO USE COPPER CONNECTIONS WITH STANDARD SECTIONS AND DIMENSIONS COMMONLY AVAILABLE ON THE MARKET (24kV - 2500A WITH FORCED VENTILATION) 3150A : COMB TYPE CONTACTS 3600A : COMB TYPE CONTACTS PLUS 1 FAN 4000A : COMB TYPE CONTACTS PLUS 2 FAN ABB - Page 15

AVAILABLE APPARATUS VM1 V-contact V/W V-contact VSC/P VD4 HD4 evm1 Circuit breakers Vacuum contactors Available apparatus ABB - Page 16 PR512 Electronic Relay (*) REF542plus Electronic devices (*) To be placed in the low voltage compartment (customer care) Service trucks Service trucks: (Only from HD4 design) Isolation Earthing with making capacity Earthing without making capacity Cable test

SOLUTIONS SPECIFICALLY DESIGNED FOR RISER, MEASUREMENT UNITS AND DIRECT INCOMING FEEDER SWITCHBOARD UNITS ABB - Page 17 Rated voltage [kv] 12-17,5 24 Panel width [mm] Panel characteristics Rated current up to [A] Isc [ka] Isw [ka] 3s- 1s Riser or direct incoming feeder Riser or direct incoming feeder and earthing switch Configuration Measurement unit (VT compatment at customer care) Measurement unit and earthing switch (VT compatment at customer care) 600 1250 31,5 31,5 PB1/R PB1/R PB1/R PB1/R 750 1000 2000 4000 31,5 31,5 31,5 31,5 40-50 40-50 40-50 40-50 PB2/R PB3/R PB2/R PB3/R PB2/R PB3/R PB2/R PB3/R 750 1250 25 25 PB4/R PB4/R PB4/R PB4/R 1000 2500 25 25 PB5/R PB5/R PB5/R PB5/R

SWITCHGEAR COMPLETION : ABB PROPOSAL FOR OEM (cable access compartment at customer care for PB/E) REF542plus (Low voltage compartment and rear part of the switchgear at customer care) TRADITIONAL CURRENT TRANSFORMER - DIN STANDARD DIMENSIONS OR ABB - Page 18 TRADITIONAL VOLTAGE TRANSFORMER COMBI SENSOR (VOLTAGE AND CURRENT) ACCORDING DIN STANDARD DIMENSIONS

REF 542 plus Integrated control and protection unit Panel type ABB - Page 19 50, overcurrent instantaneous 51, earth fault 51N, earth fault directional 51IDMT, overcurrent inverse definite time 51MS, motor start protection 51LR, locked rotor protection 46, unbalanced load 49, thermal overload 27, undervoltage istantaneous 66, number of starts 67, overcurrent directional 67N, earth fault directional 79, autoreclosing Protection functions Incoming feeder Outgoing feeder, generic Outgoing feeder for transformer Outgoing feeder for motor, circuit breaker Outgoing feeder for motor, contactor Present. On request.

The use of sensors gives the following advantages: High accuracy and linearity Large dynamic range Low temperature coefficient No saturation No iron-resonance Compact and effective solution ABB - Page 20

Current transformers Long Size Medium Size Dimensions according to DIN 42600 standard Narrow Type. Electrical characteristics according to IEC 60044-1. Sets per phase: 1 Medium size 1 Long size 2 Medium size 1 Medium size and 1 Long size ABB - Page 21

Voltage transformers Dimensions according to DIN 42600 standard Narrow Type. Electrical characteristics according to IEC 60044-2. Type: Fixed Fixed with fuses Withdrawable with fuses ABB - Page 22

Current and voltage sensors ABB KEVCD Combi Sensor Block Type Dimensions according to DIN 42600 standard Narrow Type. Current sensors compliant with IEC 60044-8 / CDV. Voltage sensors compliant with IEC 60044-7. Main characteristics: In the combi sensors both current and voltage sensors are integrated in the same compact cast resin part. Current sensor is based on a Rogowski coil. Voltage sensor is based on a resistive divider. Also a capacitive divider for voltage indication is included. ABB - Page 23