KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

Similar documents
KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

ECOCLEAN. Compressed Air Filters

High efficiency compressed air filtration & water separation

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS

Compressed Air Filters

Product Data Sheet Filter Elements ERUF.. (for ultrafilter filter housings)

THE NEW GENERATION! COMPRESSED AIR FILTERS AND WATER SEPARATORS INTELLIGENT AIR TECHNOLOGY

Product - Specification

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.

SULLAIR Oil Free Rotary Screw Air Compressors

Product Range & Price Guide

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series

Compressed Air Filtration

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

Reciprocating Compressors Industrial Quality

Compressed Air Filtration

Compressed Air Cleaning Filter Series

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

ÖWAMAT. National technical approval Z Deutsches Institut für Bautechnik, Berlin

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Product Range. March 2010

COMPRESSED AIR & GAS TREATMENT. PureTec. Compressed air filtration. Purifying your compressed air, increasing your efficiency.

Splash-proof Terminal HEPA Filter

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Portable Compressors MOBILAIR M 123 With the world-renowned SIGMA PROFILE Free air delivery 11.4 m³/min.

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Compressed Air Filtration

MOBILAIR M 125. Portable Compressor With the world-renowned SIGMA PROFILE Max. flow rate 11.5 m³/min (405 cfm)

Profluid and Gap-type tube filters. Automatic filters

200-SERIES EXTRACTION

SUCTION FILTRES. 3D drawings available at

COMPRESSED AIR FILTERS AF SERIES Product overview

Process Filtration From Pure to Sterile

A I R C O M P R E S S O R S R O L L A I R E

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

SE M.C.N.51D

P-SRF V STERILE AIR PLEATED DEPTH FILTER ELEMENTS

Automatic filter AF 113 G

MOBILAIR M 350. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 24.0 to 34.0 m³/min (850 to 1200 cfm)

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

EnviroAire T/TVS Series

Filter Housing SG ATEX Standard

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Index: ** Managing Machine Reliability ** How do Air Breathers work The benefits of Air Sentry Desiccant Breathers Air Sentry Z-Series Breathers

Table of Contents - Vangard Filters

Filters for Compressed Air

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CROSS REFERENCE 2017

Process Technology Catalytic Converter BEKOKAT

INFASTAUB. Breathe The Difference: Pure Air. INFA-JET Pocket filter

COMPRESSED AIR FILTERS

MOBILAIR M 122/M 123. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 7.3 to 11.4 m³/min ( cfm)

The Importance of Air Quality

Reciprocating Compressors Industrial Quality

Full power Cyclone precleaner technology when the going gets dusty

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

JG, JK, JP Ultrafilter

Filters MS-LFM/LFX, MS series, NPT

Automatic filter AF 112 G

where nature and technology meet FILTRATION Solutions for filtration applications PETROGAS GAS-SYSTEMS BV

Introduction. Operation FTG 600

Automatic metal-edge filter AF 75 S / AF 95 S

5.22 A IR PREPARATION FILTERS: HIGH EFFICIENCY H IGH FLOW AIR FILTER SERIES AF AF (1 1 2) AF (2) AF (1 1 2) AF (2) S TOCKED

Compressed Air Filtration

SPUN (MELT-BLOWN) POLYPROPYLENE MICRON FILTER CARTRIDGE

WARCO CHEMAG SERIES GH FILTERS

UNIBAD. Bath water circulating pump

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

Industrial Air Compressors & Compressed Air Systems

Automatic filter AF 173 G

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Reciprocating Compressors EUROCOMP Series

FP 150 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY. Similar to image VN-8-02

MINI-VERTICUS & VERTICUS THE NEXT GENERATION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

HS10S-FA. Water station. Product specification sheet

Filter solutions for Danfoss PAH, APP and CLP pumps

Compact Finedust / HEPA Filter

Portable Compressors MOBILAIR M 36 / M 45

Filter solutions for Danfoss PAH, APP and CLP pumps

Modular filter system for effective removal of oil mist

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

HS10S-FA. Water station. Product specification sheet

Process Inline Filter Protective filter PLF2-9HF

Air Handling Units. Geniox. Accessories

ALUMINIUM COMPRESSED AIR FILTERS

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2

About Dustcontrol Filter Units

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

A LEADING MANUFACTURER OF ABSOLUTE RATED FILTERS

MOBILAIR M 135/M 170/M 171. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 10.5 to 17.0 m³/min ( cfm) COMPRESSORS

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

MAHLE Industrial Filters. Automatic Filters

COMPRESSORS MOBILAIR M 36/M 45. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min ( cfm)

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Transcription:

BA SIC.LINE Rev 1.0.1 Page 1 of 9 KSI Filtertechnik GmbH Siemensring 54-56 D-47877 Willich Tel. +49 21 54 89 108-0 Fax +49 21 54 89108-282 www.ksi.eu mail@ksi.eu ECOCLEAN Compressed air filters new generation Reliable high-performance filtration for treating compressed air and gas at the highest industrial quality. All KSI products are produced according to DIN EN ISO 9001 Mistakes and technical changes reserved. Compressed air filters and separators to guarantee the quality of compressed air in modern production processes

High quality through manufacturer expertise Rev 1.0.1 Page 2 of 9 Modern production methods make ever increasing demands on the quality of compressed air. However, the ambient air taken in and compressed by the compressor is heavily contaminated by impurities. Moreover, depending on the compressor type, the delivered air will contain oil, which is conveyed with the compressed air in fine aerosols, together with impurities from the compressed air network, e.g. rust and scale. In addition, any condensate formed must be removed from the system. The function of the ECOCLEAN compressed air filter is to remove these impurities and condensate, to prevent damage to the downstream equipment. KSI Filtertechnik GmbH produces ECOCLEAN compressed air filters and filter elements in-house. This ensures complete control for safeguarding our certified KSI industrial equipment quality. For that reason our compressed air treatment components satisfy current as well as future market demands. This assurance is provided through long term and continuous cooperation with market specialists, specialised trade channels, the institutes, as well as our ongoing and intensive development work. The heart of each compressed air filter is the filter element. This component has to be chosen very carefully to ensure that the filter works according to its purpose. A filter can remove, depending on the selected element, solid particles, oil droplets, condensate, oil vapour, odours etc. from the compressed air system. The new filter grades DMF and DSF are specifically designed for the removal of dust particles. The combination of operation security and efficiency in one product is the idea behind the ECOCLEAN product line. This idea is also envisioned in the ECOCLEAN high performance filter elements. All advantages of ECOCLEAN filter elements are not only feasible when using the element in an ECOCLEAN compressed air filter, but also when using in nearly all filter housings of other manufacturers available on the market. Another advantage: These filter elements are available for a price which is up to 30% cheaper (compared to filter elements in the market which show equal quality). Compressed air filters of the new generation have several advantages. First, the differential pressure is much lower thanks to the removal of the tie rod. This change also simplifies the installation as the element is only placed in the filter housing. An unconvenient mounting via tie rod is no longer needed. Another aspect is about the space under the filter. Formerly the filter bowl needed to be removed before the element could be changed. The filter bowl can be moved to the side directly after turning it out of the filter head now. Function Water separation To provide best quality compressed air a water separator should be installed in front of a compressed air filter. The water separator extracts condensate by using a simple physical law. The higher compressed air quality prolongs the durability of the filter element in the compressed air filter. Compressed air filtration Due to the arch-shaped compressed air inlet the filter volume is completely used and there is up to 75% less flow resistance. The actual filtration is performed by the different layers of the filter element. The compressed air flows through them from inside to outside. In the different layers the different unwanted components of the medium are extracted. Behind the compressed air filter high quality compressed air is ready to use.

Rev 1.0.1 Page 3 of 9 ECOCLEAN Compressed air filters offer a double advantage Reliability 1. Optimum Operational Reliability Cost 2. Maximum Cost Effectiveness Filter housing Filter housing A High-quality cast aluminium with anticor- KSI high-performance filters lower energy rosion coating (on the inside and outside), plus an impact and scratchresi- A costs drastically through minimized investment costs and low differential pressure, stant resin powder coating provide while providing maximum efficiency. a corrosion-resistant filter housing. A The differential pressure indicator displays B Condensate is continually removed via B the most economical point in time for a filter the automatic D150 (from GTF-BL140/ C element change, reducing operational costs. D200) condensation drain. As a user- B Ideally sized connections and optimized flow friendly feature the internal pressure can be released via the condensate drain. A paths achieve high flow efficiency to avoid pressure losses that increase costs. C Highest quality with every ECOCLEAN C D C ECOCLEAN filter housings achieve up to filter verified as 100% leak-proof. 75% lower flow resistance compared to housings D Filter element Suspension anchoring positions the element securely and reliably. Differential E I F D F D with right-angle flow paths. Filter element The specially designed interior and exterior pressure is reduced due to the removal of ECOCLEAN support cages gain up to the tie rod. 45% less differential pressure as compared E A special compound adhesive securely H to conventional support cylinders. F fixes the end caps to the stainless steel support cages and the filter media. The ECOCLEAN high performance filter E G E Energy saving filter media The KSI high-performance element achieves media is securely fixed and supported maximum filter surface area through between stainless steel layers. the specially optimized winding of the filter G The plasticizer-free end caps media. The construction-based surface prevent corrosion. This means no filtration, in contrast to the usual 2-layer efflorescence and no increased bacteria growth. B pleated elements, achieves a significantly higher internal surface area (filter depth High-performance filter media volume) for maximum depth filtration. Due to this very high depth filtration capacity of H The filter drainage layer made of special ECOCLEAN filter elements the differential fleece stabilizes the filter media and pressure rises very slowly giving long life prevents efflorescence and cracking and reduced energy costs. meaning it safely counteracts the loss F The media depth volume ensures the highest of filtering action. contaminant removal, whilst allowing I The high-performance filter fleece has a maximum filtration performance. high chemical, mechanical and thermal loading capacity (up to 120 C), and it is A hexagonal nut on the outside silicone-free. of the filter housing base facilitates quick and easy service.

Compressed air filter elements Rev 1.0.1 Page 4 of 9 Type SMA/DSF 0,01 micron separation efficiency Max. residual oil content at 20 C: 0,01 mg/m 3 Max. temperature: 120 C Type MFO/DMF 1 micron separation efficiency Max. residual oil content at 20 C: 0,1 mg/m 3 Max. temperature: 120 C Type FF5 5 micron separation efficiency Max. residual oil content at 20 C: 5 mg/m 3 Max. temperature: 120 C Type VF25: 25 micron separation efficiency Max. residual oil content at 20 C: 10 mg/m 3 Max. temperature: 120 C Type CA (activated carbon) Max. residual oil content at 20 C: 0,003 mg/m 3 Max. temperature: 70 C (effective up to 30 C) Element Type SMA/DSF MFO/DMF FF5 VF25 CA Max. particle Ø [micron] Compressed air class Max. residual oil [mg/m 3 ] *ECOCLEAN high performance filter elements exceed ISO 8573.1 requirements. Water Separators WS Water separators Cyclone separators that safely separate condensate using centrifugal force

Rev 1.0.1 Page 5 of 9 Capacities and dimensions compressed air filters Type Capacity* Dimensions (mm) Connection Element Amount m 3 /h cfm A B C D GTF-BL25 35 21 90 21 220 110. GTE3711 1 GTF-BL50 52 31 90 21 220 110 D/ i GTE3711 1 GTF-BL60 52 31 90 21 220 110 - GTE3711 1 GTF-BL70 120 71 90 21 281 160 - GTE5111 1 GTF-BL80 120 71 90 21 281 160 : GTE5111 1 GTF-BL90 216 127 130 40 332 260 : GTE7111 1 GTF-BL100 216 127 130 40 332 260 1 GTE7111 1 GTF-BL110 360 212 130 40 478 310 1 GTE7311 1 GTF-BL120 540 318 130 40 482 390 1. GTE7411 1 GTF-BL130 725 426 130 40 545 435 1 - GTE7411 1 GTF-BL135 725 426 130 40 545 435 2 GTE7411 1 GTF-BL140 800 471 184 51 704 490 2 GTE8501 1 GTF-BL160 1200 706 184 51 704 560 2 GTE8601 1 GTF-BL170 1500 882 250 74 620 440 2 - GTE8701 1 GTF-BL190 1900 1460 250 74 1062 630 3 GTE8901 1 FF080-01 1400 823 360 162 841 550 DN 80 FE8601 1 FF100-02 2800 1647 550 245 1115 550 DN 100 FE8601 2 FF100-03 4200 2470 550 245 1115 550 DN 100 FE8601 3 FF150-04 5600 3294 620 276 1237 550 DN 150 FE8601 4 FF150-06 8400 4941 800 300 1270 680 DN 150 FE8601 6 FF200-08 11200 6588 800 328 1275 680 DN 200 FE8601 8 *refer to 1 bar (abs.) and 20 C at 7 bar g operating pressure Max. operating pressure: GTF25 GTF170: 16 bar g, GTF190: 12 bar g, FFo80-01 FF200-08: 16 bar g For drawings and correction factors turn to page 9. Field of application Installation site Ambient temperature max. Ambient temperature min. Operating pressure Medium Installation inside in non-aggressive atmosphere 50 C +2 C 2 to 16 bar g, GTF-BL190: 2 to 12 bar g Compressed air and gases Technical features Separation efficiency VF25 FF5 MFO/DMF SMA/DSF Particle filtration 25 micron 5 micron 1 micron 0,01 micron Max. residual oil at 20 C 10 mg/m 3 5 mg/m 3 0,1 mg/m 3 0,01 mg/m 3 Pressure drop - clean and dry 30 mbar 40 mbar 75 mbar 100 mbar Pressure drop - oil saturated 50 mbar 75 mbar 150 mbar 300 mbar Pressure drop - change element 400 mbar 400 mbar 400 mbar 400 mbar

Water Separators capacity and dimensions Rev 1.0.1 Page 6 of 9 Type Capacity* Dimensions (mm) Connection m 3 /h cfm A B C GTF-BL25 WS 35 21 90 21 220. GTF-BL50 WS 52 31 90 21 220 D/ i GTF-BL60 WS 52 31 90 21 220 - GTF-BL70 WS 120 71 90 21 281 - GTF-BL80 WS 120 71 90 21 281 : GTF-BL90 WS 216 127 130 40 332 : GTF-BL100 WS 216 127 130 40 332 1 GTF-BL110 WS 360 212 130 40 478 1 GTF-BL120 WS 540 318 130 40 482 1. GTF-BL130 WS 725 426 130 40 545 1 - GTF-BL135 WS 725 426 130 40 545 2 GTF-BL140 WS 800 471 184 51 704 2 GTF-BL160 WS 1200 706 184 51 704 2 GTF-BL170 WS 1500 882 250 74 620 2 - GTF-BL190 WS 1900 1460 250 74 1062 3 FF080-01 WS 1400 823 360 162 841 DN 80 FF100-02 WS 2800 1647 550 245 1115 DN 100 FF100-03 WS 4200 2470 550 245 1115 DN 100 FF150-04 WS 5600 3294 620 276 1237 DN 150 FF150-06 WS 8400 4941 800 300 1270 DN 150 FF200-08 WS 11200 6588 800 328 1275 DN 200 *refer to 1 bar (abs.) and 20 C at 7 bar g operating pressure Max. operating pressure: GTF25 GTF170: 16 bar g, GTF190: 12 bar g, FFo80-01 FF200-08: 16 bar g For drawings and correction factors turn to page 9. Field of application Installation site Ambient temperature max. Ambient temperature min. Operating pressure Medium Installation inside in non-aggressive atmosphere 50 C +2 C 2 to 16 bar g, GTF-BL190 WS: 2 to 12 bar g Compressed air and gases Technical features Max. operating pressure GT F-BL25 WS - 170 WS: 16 bar g GTF-BL190 WS: 12 bar g FF080-01 WS - FF200-08 WS: 16 bar g Max. temperature 70 C Min. temperature 2 C Pressure drop 70 mbar

Rev 1.0.1 Page 7 of 9 Approvals for Pressure Equipment EU Other Approved for fluid group 2 according to Pressure Equipment Directive 97/23/EG, module B+D (categorie IV) ASME Quality Management Development/Production DIN EN ISO 9001 Air purity class according to ISO 8573-1:2010 Solid particles according to filter element, page 2 Humidity (gaseous) according to filter element, page 2 Total oil according to filter element, page 2 Versions and options ECOCLEAN GTF-BL with threaded connection for volume flows from 21 cfm to 1460 cfm ECOCLEAN FF with flanged connection for volume flows from 823 cfm to 6588 cfm Various filter grades: VF25, FF5, MFO, SMA, CA, DMF, DSF (DMF and DSF filters are run through vice versa) Options: page 8 The ECOCLEAN Basic.Line Plus Effect +++ + protects production & processes => extends machine & installation endurance + minimises operating costs => saves energy + maximises operational reliability => protection against production or machine downtime + best industrial equipment quality => long lifetime + easy serviceability => minimized service costs + quick and secure assembly => quick installation + user-oriented filtration (25, 5, 1 and 0,01 micron as well as activated carbon) => optimum selection + very competitive price-performance ratio due to no customization, only available in one colour and without private labelling KSI alternative filter elements The customer enjoys all of the advantages of the ECOCLEAN filter elements not only if the filter elements are used in an ECOCLEAN compressed air filter, but also when they are used in almost any of the housings from other manufacturers that are on the market. A further advantage: KSI offers these filter elements at prices that are up to 30% lower (than qualitatively comparable filter elements on the market).

BA SIC.LINE Rev 1.0.1 Page 8 of 9 ECOCLEAN High-performance compressed air filters Options Differential pressure indicator Volt free digital differential Moisture indicator Oil indicator pressure manometer Filter connection set Wall mount incl. filter connection set Condensate drains automatic drain D150, automatical drain D200, level-regulated condensate manual drain HAM12, standard for threaded filter standard for threaded filter drain KONDRAIN N1 standard in CA activated carbon GTF-BL25 - GTF-BL135 GTF-BL140 - GTF-BL190, as (option for ECOCLEAN grade, as well as in all cartridge well as for all flanged filters standard filter) filters

Rev 1.0.1 Page 9 of 9 Drawing compressed air filter with threaded connection Drawing water separators Drawing compressed air filter with flanged connection Correction factors Operating pressure bar g 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 factor 0,38 0,50 0,63 0,75 0,88 1,00 1,12 1,25 1,37 1,49 1,62 1,74 1,86 1,98 2,10 Please multiply the capacity of the filter with the correction factor in the table above. Example: Capacity Type GTF70 at 10 bar g - Capacity nominal (71 cfm) x factor (1,37) = Capacity corrected (97,3 cfm)