Basalt Fire-Rescue Engine 43 Inspection

Similar documents
Basalt Fire Rescue Engine 40 Inspection. Maps (in manila folder) Garmin GPS. Incident organizers Binoculars. Hazmat ERG Assorted pens and legal pad

EAST LAKE TARPON SPECIAL FIRE CONTROL DISTRICT E58 CHECKLIST (5-1-15) MONTH OF: YEAR: DATE:

Basalt Fire-Rescue Rescue 41 Inspection

Basalt Fire-Rescue Rescue 41 Inspection

Sunday, June 2, 13. Truck 6 Apparatus Familiarization Guide

Standardization of Fire Apparatus

32 quarts Transmission Allison HT 740 Automatic Fluid

The following chart shows the NUS minimum stocking levels required for agency engines. Type Category Item Description NFES # 3, 4, & 5 6

LEVEL 2 DEFENSIVE Standard Equipment Guide

EMPLOYEE ORIENTATION SKILLS

1500 GPM CAFS WASP Sheldon Fire & Rescue Houston, TX ESD 60 ESD 60. Darley September 25, 2015 PART NO DESCRIPTION QTY

QUARTERLY / ANNUAL MOBILE FIRE APPARATUS INSPECTION REPORT. Manufacturer. Serial no. Legend:

ENGINE COMPANY OPERATIONS AND ASSIGNMENTS

Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD 2008, GBW Associates, LLC Westminster, Maryland

Squad 133. Inventory List. (updated 6-06)

TRIP Equipment Requirements

CRD Emergency Hazmat Team

ADDENDUM NO. ONE AIRCRAFT RESCUE AND FIRE FIGHTING AND AIRPORT OPERATIONAL SUPPORT SERVICES FOR THE TRENTON MERCER AIRPORT AB

Albemarle County Virginia Brush Fire Truck Specification

BEAVER EMERGENCY SERVICES COMMISSION REGULATION

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

HEAVY RESCUE. Model DF0973. HAZEN FIRE DEPARTMENT Hazen, North Dakota

As a safety precaution, remove keys from the ignition while working under or around the vehicle.

Chapter 15. Fire Hose. Answer Key. Firefighter I

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial

Lightweight Aluminum Alloy Adapters

THE CO$T OF DOING BU$INE$$

B Pump Mounting. Page 1 of 7

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

Driver/Operator Program Part III - Tanker

Larsen Marine Services Equipment Resources

HEAVY RESCUE. Model DF0976. PUMPKIN CENTER FIRE DEPARTMENT - Jacksonville, NC

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

PART NO DESCRIPTION QTY

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

THE REVOLUTIONARY STINGER

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

Truck Specs. Sabre 9 Off-Highway GCWR: 242,000. CapacityTrucks.com

Routine Emergencies are defined as incidents that do not require the deployment of hoselines. Ex. Fire alarms, smell of smoke, etc..

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL DRIVER OPERATOR PUMPING PAGE 1 OF 6 Nozzles & Hose Revised

REAR MOUNT AERIAL LADDER USED AS A WATER TOWER

REGIONAL DISTRICT of OKANAGAN-SIMILKAMEEN REQUEST FOR QUOTATIONS Fire Truck Tulameen Fire Department February 2, 2016

INSTALLATION INSTRUCTIONS

HEAVY RESCUE. Model CRS0862. Bentleyville Fire Department Bentleyville, PA

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

VEHICLE DISMANTLING MANUAL. Corvette GMP/01-Y-ELV

Commercial Traditional Engine 1250 GPM Side Mount Pump Rating 1200 Gallon - Stainless Body

SYRACUSE FIRE DEPARTMENT RFP SPECIFICATIONS FOR 3000 GALLON WATER TENDER

Driver/Operator - Mobile Water Supply

WILDFIRE OPERATOR TRAINING MANUAL

2010 SPARTAN/CRIMSON ENGINE 120 GLADIATOR CLASSIC

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of Sutphen Aerial Operations Revised

CBRNE HAZMAT. Model HM0875R YONKERS POLICE DEPARTMENT YONKERS, NY

HEAVY RESCUE. Model DFC1173R24. LAFAYETTE TOWNSHIP FIRE PROTECTION DISTRICT Floyds Knob, IN

MEDIUM RESCUE. Model DF0964-R24. Washington Fire Department, North Carolina

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 10 Apparatus Service Tests Revised

Handline Nozzles. Foam Tubes In Line eductors & Piercing Nozzle. Forestry Products. Firehouse cleaning Products

NOZZLES NOZZLES SPECIALTY SABERJET NOZZLES THE FIRST TRULY MULTI-PURPOSE NOZZLE

NOZZLES HANDLINE NOZZLES MASTER STREAM PIERCING NOZZLES PLAYPIPES

NOZZLES NOZZLES DARLEY FIRE STORM NOZZLE DELIVERS QUALITY AND PERFORMANCE TURBOJET NOZZLES NEW LOW PRICE

INSTALLATION INSTRUCTIONS 97 FORD EXPEDITION

FOAM GUN PROPORTIONER THE FOAM GUN PROPORTIONER FOAM CARTRIDGES

PARTS LIST PONY 20 SCA

Fire Fighting, Police, and Emergency Equipment 135

Standard features. Standard features of the Unimog U500 NA 2005 model

WATER SUPPLY AND DISTRIBUTION SYSTEMS

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

Hose & Apparatus Test Equipment

Fittings & Accessories

Your Legal Fuel Tank Source.

* * * * * * * * ET Number. Tool Image Barcode. Ryobi Cordless String Trimmer ET0001

Zip's Truck Equipment. 316 W. Milwaukee Street New Hampton, Iowa Phone: Fax: Visual Inspection.

LIGHT RESCUE. Model LR0776. LULING FIRE DEPARTMENT- Luling, Louisiana

Titan 50 Series Crane Service Bodies Titan CA. Titan 50 84CA

Suggested Spares Guide L115F-310

HEAVY RESCUE. Model DFC1364R24. Ayden Fire Department Ayden, North Carolina

RAPID INTERVENTION TEAM STANDARD OPERATING PROCEDURES

List Price Guide. Effective: March 4, All Prices in U.S. Dollars. Supersedes All Previous Prices

Portable Sealcoating Spray Systems

The following is a list of guidelines that apply to all evolutions.

2011 Cat Hand Tools and Shop Supplies

Bucket Harness. Installation Instructions. for Electric Club Car Precedent

HAZMAT TRAILER. Model TDD1387. TALLAHASSEE FIRE DEPARTMENT Tallahassee, Florida

SCARIFIER 802 GARDEN TOOLS 803 LAMP SHADE 804 BOX OF ODDS & SODS 805 CHICKEN NETTING 806 NESTING BOXES 807 FEEDERS & DRINKERS 808 FEEDERS & DRINKERS

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations

AKRON BRASS COMPANY PH ( ) FAX ( )

* * * * * * * * ET Number. Tool Image Barcode. Ryobi Cordless String Trimmer ET0001

LOT LIST QTY DESCRIPTION NOTES

1500 GPM Vision WASP W. S. Darley & Co

ST - HD - HDXL Model

2015+ dodge charger dedicated fuel system

LIST PRICE GUIDE. ALL PRICES IN U.S. DOLLARS Effective: August 1, 2011 AKRON BRASS COMPANY TERMS AND CONDITIONS

Request For Bids. Sewer Cleaner Truck

Heavy Rescue. Model DFC1163R22

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Milton Fire-Rescue Capital Improvement Plan

Transcription:

Updated 8/9/17 Date of inspection OIC Truck Cab Map book/reference book/sop book HazMat pocket guide (glovebox) CO Monitor Motorola portable radio (1 with headset for driver/operator) (3) Traffic vests (one on each seat) Explosive Gas Detector Binoculars Compartment L1 (Driver s side, front) Roll of black plastic Fire line tape Garbage bags 6 Suction barrel strainer 2 ½ Port-a-Tank 90 degree Inlet (2) Lite boxes in chargers MSA Thermal Imager, spare battery, operational check Roadside hazard kit (triangles) Hose jacket (2) Hose straps Hose clamp 2 ½ Select-o-matic nozzle 2 ½ Smooth bore nozzle 2 ½ hydrant gate valve (3) 2 ½ double male (3) 2 ½ double female (1) 1 ½ double male (1) 1 ½ double female (2) 2 ½ X 1 ½ reducer Foam Bucket Wrench 2 ½ X quick adapter 2 ½ male X 1 ½ female reducer (1) 5 stortz x 2 ½ adapter (2) LDH spanners (on door) 2 ½ x 1 ½ gated wye 2 ½ Siamese (1) 25 1 ½ engine protection hose with nozzle Rubber mallet 2 ½ gallon regular fuel can 2 cycle oil Power steering fluid (1 quart) Ear plugs 5 Stortz manifold Portable pump

Gas check ATF (1 quart) Compartment L1 continued 1 ½ gallon Pre-mix fuel can with bar oil (Dolmar) Stihl 046 chain saw Bar Oil check Saw tool kit Chaps Compartment L2 (Driver s middle high side) (4) MSA Fire Hawk SCBA s Masks 4000 psi minimum Operational check & batteries SCBA Transfill Hose in Belt Bag 4 Spare bottles in wheel well compartments, 4300 psi min. Compartment L3 (Driver s rear) Tow strap 25 twist-loc extension cord 50 twist-loc extension cord Adapter 3-prong x twistlock female Adapter twistlock x 3- prong female (2) 500 watt portable floodlights Tire chains 20# ABC Extinguisher Rehab Supplies Gas powered PPV fan Operational (run for 5 minutes minimum) Compartment R1 (Officer s side front) Haligan bar Flat head axe Pickhead axe 4 pry bar 10# sledge hammer Bolt cutters Short handled spade BLS Bag (2) Rip stop tarps (salvage covers) (1) Floor Runner

Compartment R3 (Officer s side rear) (1) Wildland Progressive Pack (1) 100 Stick 1 ½ Hose with 1 ½ Gated Wye and Nozzle attatched Electric Cord reel (2) 100 sticks 1 wildland hose (3) 1 ½ nozzles (2) 1 nozzles (1 regular, 1 forestry) Compartment R2(Officer s high side) 24 Extension ladder 14 Roof ladder 10 Attic ladder Compartment (Rear high) 1,500 gallon port-a-tank Compartment (Rear center) Port-a-power extrication tools TNT portable pump Gas Oil Operational test Combi tool Operate Lubricate with moly lube Glass master Assorted cribbing Duct tape Sawsall Bottle soapy water (7) Traffic Cones (tailboard) Caution Road sign Duct tape 2 ½ Light Water Extinguisher Hose bed Generator Operational check 2 ½ Float Dock Strainer

Deck Gun with ground base 6 jet siphon strainer Hose Loads 1 ¾ x 200 Cross lay, Yellow (curbside) 1 ¾ x 150 Cross lay, Red (streetside) 1 ¾ x 100 Bumper line w/ nozzle 2 ½ x 200 Officer s side rear pre-connect w/ gated wye 2 ½ x 150 Driver s side rear pre-connect w/ nozzle 1000 3 supply hose 350 5 supply hose with Stortz x 4 ½ adapter (3) 6 x 10 lightweight hard suction (3) 2.5 x 10 hard suction (Cam-Lock adapter attached to one suction) Officer s side panel 5 LDH intake relief valve 4 NST x 5 Stortz 30 o adapter Spanner wrench set/ldh spanner wrench set Functional tests Emergency lights Scene lights Truck lights (headlamps, marker lights, taillights, cab lights, etc) Horns (air and electronic) Siren Pump operation Engage Check pressure governor (150psi) Flow water Disengage Generator Check outlets Tele-lights Portable lights Radios Exercise Valves- Ensure tank to pump valve is open. Open valve drains, exercise valves and flush. Close all drains.

Chassis Inspection Fluid OK Added Engine oil Coolant Windshield washer Fuel Batteries Tires Wheels Engine hours Odometer Comments