Operator s Manual TC-253A. Temperature Converter

Similar documents
RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

TACH-10 Contact / Non-Contact Tachometer

PY-11 Voltage & Continuity Tester

TMA5 Mini Vane Anemometer

TIME-10 Process Control Stopwatch

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

THWD-3 and TH-3 Relative Humidity and Temperature Meters

KMP Insulation-Continuity Tester. Users Manual

operating manual DL7 101 DIGITAL THERMOMETER

KMP7010. Ground Resistance Tester. Users Manual

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

INSP-3 Wiring Inspection Tester

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

TMD90A Dual Input Digital Thermometer

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

i3000s/i2000 Flex AC Current Probe

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

Infrared Thermocouple Probe

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Barnant Company (Type J) (Type K) (Type T)

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

i400s Calibration Information Introduction


Defender 3000 Series Base Instruction Manual

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Users Manual. Phase Rotation Indicator

DT304. Digital Temperature Logger INSTRUCTION MANUAL

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

323/324/325 Clamp Meter

Thermistor Thermometer MODEL NO

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

Hybex Microsample Incubator

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Thermocouple Thermometer Models

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

712 RTD Calibrator. Instruction Sheet. Introduction

CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

IAQ-CALC TM Indoor Air Quality Meter

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

362 Clamp Meter. Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Mini Multimeter with Non-Contact Voltage Detector (NCV)

362 Clamp Meter. Users Manual

For technical questions and replacement parts, please call

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

SLA Battery Capacity Analyzer

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

80PK-2A Type K Immersion Probe

INSTRUCTION MANUAL DM5B Fax: (503)

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Thermometer models / 00831A

Wireless Thermometer model 00380


MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

365 Detachable Jaw True-rms Clamp Meter

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

PolyStat Immersion Circulators

OMEGA. HH63KF-MV Temperature Transducer

(Type J) (Type K) (Type T)

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

6. Electrical. 7. Settings. 8. Quick

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Autoranging Multimeter

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

Temperature Calibrator

716 Pressure Calibrator

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

302+/303 Clamp Meter. Users Manual

DC REGULATED POWER SUPPLY

HyperFlex 12G.

Model 1672, 1673 Triple Output Power Supply

True RMS Autoranging Multimeter

OPERATING INSTRUCTIONS

Indoor Air Quality Meter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

373 Clamp Meter. Users Manual

5.2 PRE-OPERATION PROCEDURE WARRANTY

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Digital Auto Multi-Tester

flexible infrared thermometer

Intelligent Electronic Safe

IAQ-CALC TM Indoor Air Quality Meter

OMEGA. CL3512 Digital Thermometer & Calibrator

Visit us at

Transcription:

Operator s Manual TC-253A Temperature Converter TM Temperature Converter

WARRANTY The TC-253A Temperature Converter is warranted against any defects of material or workmanship within a period of one (1) year following the date of purchase of the instrument by the original purchaser or user. Any accessory claimed to be defective during the warranty period should be returned with proof of purchase to an authorized Wavetek Meterman. Service Center or to the local Wavetek Meterman dealer or distributor where your multimeter was purchased. See maintenance section for details. Any implied warranties arising out of the sale of a Wavetek Meterman product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to the above stated one (1) year period. Wavetek Meterman shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss. Some states do not allow limitations on how long implied warranties last or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. EXPLANATION OF SYMBOLS Attention! Refer to Operating instructions. Ground connection. Battery. WARNING AND PRECAUTIONS nthis instrument is designed to use external K-type thermocouple as temperature sensor. ntemperature indication follows National Bureau of Standards and IEC 584 temperature / Voltage tables for K-type Thermocouple supplied with the thermometer. ninspect DMM, TC-253A, and thermocouple cable before every use. Do not use any damaged part. nnever ground yourself when taking measurements. ndo not touch exposed circuit elements or probe tips. ndo not operate instrument in an explosive atmosphere. nvoltages applied to the COM connector may be present on all other input connectors. ndo not use this piece or any piece of equipment without proper training.

WARNING! n TO AVOID ELECTRICAL SHOCK, DO NOT USE THIS INSTRUMENT WHEN VOLTAGES AT THE MEASUREMENT SURFACE EXCEED 24V r.m.s. AC OR 60V DC. n TO AVOID DAMAGE OR BURNS DO NOT MAKE TEMPERATURE MEASUREMENTS IN MICROWAVE OVENS. UNPACKING AND INSPECTION Upon removing your new Temperature Converter from its packing, you should have the following items: 1. Temperature Converter 2. K-type Bead Thermocouple 3. Operator s Manual FRONT PANEL Refer to Figure 1 and the following numbered steps to familiarize yourself with the meter s front panel controls and connectors. 1. Red LED: Flashing while turned ON. 2. Function Switch: Slide switch used to select measuring function. 3. Output plugs: Voltage output. 4. Thermocouple Input Connector. Figure 1 3 2 1 4

PREPARATION AND CAUTION BEFORE MEASUREMENT 1. Before measurement, warm up for at least 30 seconds, after connecting the thermocouple to the connector of the Temperature Converter. 2. If the instrument is used near noise generating equipment, be aware that the Voltage output may become unstable or indicate large errors. 3. Check TC-253A battery. The multimeter should read > 7.1 volts in the OFF position. TEMPERATURE MEASUREMENTS 1. Warning! do not measure the temperature of any surface that the potential exceeds 60 Vdc or 24 Vrms. 2. Connect the plug of the thermocouple to the connector of the thermometer. 3. Select the ºC/ºF function desired. 4. Insert the Output Plugs (V and COM) to the input terminals of Multimeter. Set the Multimeter to DC mv or V range. 5. Place the sensing point of thermocouple on the surface or environment to be measured. 6. Wait until the reading stabilizes. GENERAL SPECIFICATIONS This Temperature Converter conforms to the temperature/voltage tables of the National Bureau of Standards and to the IEC 584 Standards for K-type. 1. Temperature Scale: Celsius or Fahrenheit user selectable. 2. Input: Single K-type thermocouple. 3. Output to Meter: 1mVdc per ºC or ºF. 4. Measurement Range: -50ºC to 1000ºC (-58ºF to 1832ºF). 5. Low Battery Indication: if the reading is less than 7.1V. 6. Temperature Coefficient: 0.15 x (specified accuracy) / ºC, (<18ºC or >28ºC). 7. Power Requirements: Standard 9V battery, NADA 1604, JIS 006P, or IEC6F22 Size. 8. Battery Life: Alkaline 300 hours. 9. Dimensions: 122mm(L) x 46mm(W) x 30mm(D). 10. Weight (including battery): 114 grams. 11. Accessories: K-type bead thermocouple, battery (installed), operators manual.

EMC: This product complies with requirements of the following European Community Directives: 89/336/EEC (Electromagnetic Compatibility) as amended by 93/68/EEC (CE Marking). Directive73/23/EEC (Low Voltage) does not apply to this product. However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. ENVIRONMENTAL CONDITIONS: 1. Indoor Use. 2. Operating Ambient: 0% to 80% R.H. (0 to 35 ºC); 0% to 70% (35 to 50ºC) R.H. 3. Storage Temperature: -20 to 60ºC, 0 to 80% R.H. with battery removed from Temperature Converter. ELECTRICAL SPECIFICATIONS: MEASUREMENT RANGE ACCURACY INPUT PROTECTION -50ºC -20ºC =(2.0% rdg + 2ºC) -19ºC 350ºC =(0.5% rdg + 2ºC) 351ºC 500ºC =(2.0% rdg + 2ºC) 501ºC 1000ºC =(2.9% rdg + 2ºC) 60Vdc & 24Vrms -58ºF -4ºF =(2.0% rdg + 4ºF) -3ºF 662ºF =(0.5% rdg + 4ºF) 663ºF 932ºF =(2.0% rdg + 4ºF) 933ºF 1832ºF =(2.9% rdg + 4ºF) ACCESSORIES: TP-255 Replacement Bead Probe TP-254 Immersion Probe with Handle MH101K Master Handle Probe TP110K Immersion Probe * TP120K Surface Probe * TP130K Air Probe * *(TP110K, TP120K, & TP130K require MH101K Handle)

TP-255 Bead Thermocouple: Temperature Range:-40ºC to 204ºC (-40ºF to 400ºF). Tolerances: = (2.2ºC or 0.75%) from 0ºC to 204ºC = (2.2ºC or 2.0%) from 0ºC to -40ºC Wire Length: 1 meter, with miniature plug. Teflon tape insulated. MAINTENANCE: WARNING! TO AVOID ELECTRICAL SHOCK REMOVE TEST THERMOCOUPLE BEFORE OPENING THE COVER. GENERAL MAINTENANCE: 1. The case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow the TC-253A to dry completely before using. Do not use hydro carbon or chlorinated solvents or abrasives for cleaning. 2. All calibration and repair should be performed by an authorized service center or by other qualified instrument service personnel. To maintain a thermocouple in good condition, observe the following items. n Avoid excess bending. n Don t overheat the thermocouple. n Avoid chemical reactions that can damage the thermocouple. BATTERY CHECKING AND REPLACEMENT: To check the battery: 1. Turn the TC-253A OFF. 2. Insert the output plugs (V and COM) to the input terminals of multimeter to DCV for autoranging type meter or 20 VDC or greater for manual ranging type meter. 3. Read the display on the multimeter. Replace the battery, if the reading is less than 7.1V. To replace the battery, refer to Figure 2 and use the following procedure. 1. Turn the TC-253A OFF and disconnect the multimeter and thermocouple. 2. Position the TC-253A face down. Remove the screw from the bottom case. 3. Remove the bottom case. 4. Carefully disconnect the battery from bottom case

Figure 2 Battery 9V Screw REPAIR Read the warranty located at the front of this manual before requesting warranty or nonwarranty repairs. For warranty repairs, any multimeter claimed to be defective can be returned to any authorized Wavetek Meterman Distributor or to a Wavetek Meterman Service Center for an over-the-counter exchange for the same or like product. Nonwarranty repairs should be sent to a Wavetek Meterman Service Center. Please call Wavetek Meterman or inquire at your point of purchase for the nearest location and current repair rates. All Instruments returned for warranty or non-warranty repair or for calibration should be accompanied by the following information or items: company name, customer s name, address, telephone number, proof of purchase (warranty repairs), a brief description of the problem or the service requested, and the appropriate service charge (for non-warranty repairs). Please include the test leads with the meter. Service charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Wavetek Meterman or to the specific service center. For minimum turn-around time on out-of-warranty repairs please phone in advance for service charge rates. The Temperature converter should be shipped with transportation charges prepaid to one of the addresses/service centers shown on the rear cover.

Manual Revision Date 08/00 Manual Part Number 1564694 Information contained in this manual is proprietary to Wavetek Meterman and is provided solely for instrument operation and maintenance. The information in this document may not be duplicated in any manner without the prior approval in writing from Wavetek Meterman. Specifications subject to change. Wavetek is a trademark of Wavetek Wandel Goltermann Wavetek Meterman, 2000 U.S. Service Center Wavetek Meterman 1420 75th Street SW Everett, WA 98203 Tel: (877) 956-2680 Fax: 425-446-6390 Canadian Service Center Wavetek Meterman 400 Britannia Rd. E.Unit #1 Mississauga, ON L4Z 1X9 Tel: (905) 890-7600 Fax: (905) 890-6866 European Distribution Center Wavetek Meterman 52 Hurricane Way Norwich, NR6 6JB, England Tel: (44) 1603-404-824 Fax: (44) 1603-482-409