Hamilton 3VO Submittal

Similar documents
Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

RAYPAK ILLUSTRATED PARTS LIST

Raptor 085HB-270HB & 155CB Submittal

Figure 1-1(d) Tft Installation Kit

Raptor 085HB-270HB & 155CB Submittal

Crest Heating Boilers FBN(L)

XIII. Repair Parts 106

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

AHRI Certified up to 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

Crest Heating Boilers FBN(L)

Installation, Operation and Maintenance Manual

IMMERSION FIRED HOT WATER BOILER

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Installation, Operation and Maintenance Manual

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

TSTAT0101SC Recommended (sold separately)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Replacement Parts List

COMMERCIAL and POOL MODELS: 302C THROUGH 902C

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Cooling Capacity CFM in. w.c. (125 Pa)

VENTING & COMBUSTION AIR GUIDE

RAYPAK ILLUSTRATED PARTS LIST

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

G9MXE. Product Specifications

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E

Replacement Parts List. Armor Condensing Water Heater. AW 150 thru 800

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

G9MXE. Product Specifications

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

Crest Heating Boilers FBN(L)

Replacement Parts List

RAYPAK ILLUSTRATED PARTS LIST

UPFLOW/ HORIZONTAL GAS FURNACE

RAYPAK ILLUSTRATED PARTS LIST

Crest Heating Boilers FBN(L)

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

RESIDENTIAL BOILER 95% HIGH EFFICIENCY COMMERCIAL BOILER 93% HIGH EFFICIENCY

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Cooling Capacity CFM in. w.c. (125 Pa)

D SERIES TECHNICAL DATA INFORMATION PACKET

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

D SERIES TECHNICAL DATA INFORMATION PACKET

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models

Rheem Classic Series Upflow/Horizontal Gas Furnace

Electric Resistance Boilers Steam or Hot Water

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W

AF90. AF90 Gas Furnace High Efficiency. Features

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Troubleshooting Guide

GB162 Series Boiler TR & TL Cascade Kit Configurations

Replacement Parts List

Power Flame Incorporated

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

USER MANUAL (1 of 2)

Rheem Classic Series Upflow/Horizontal Gas Furnace

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

COMMERCIAL CONCENTRATED ENERGY ELECTRIC BOILER 22.5 KW TO 180 KW

Rheem Classic Plus Series Downflow Gas Furnace

USER MANUAL. BENCHMARK Series Gas-Fired Boilers. Natural Gas & Propane Modulating & Condensing Hot Water Boiler Models: BMK 750 BMK 1000

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

G21Q ENGINEERING DATA. Typical Applications. Bulletin # March 1993

G8MVL. Product Specifications

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

KC Series Gas Fired Boiler System

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

Replacement Parts List. Armor Condensing Water Heater. AW 150 thru 800 AW-RP-11

SUBMITTAL COVER SHEET

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Transcription:

Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum outlet temperature: 210 F Lifetime thermal shock proof heat exchanger 10 year water heater/15 year boiler heat exchanger warranty 18 month parts warranty 5:1 Full modulation turndown ratio Self-diagnostic, operating, and data management HOT Controls: Gas, water, fan, and condensate drain pressures, and (6) temperature points monitored Low cost, secure, private cellular connection for all historical and live operating data management and two-way communication available Heat Exchanger ASME H Stamped (standard) ASME HLW Stamped (future option) ASME inspected and stamped for 160 PSIG max working pressure National Board registered All 316L Stainless construction Individually replaceable straight tubes Completely serviceable, water and fire sides ASME Pressure Relief Valve 125 PSI standard PSI special applications, not to exceed 125 PSI UL 795/CSA 3.4 ETL Listed Water Heaters UL 795, and CSA 3.4 Hot Water Boiler AHRI, UL 795, and CSA 3.4 HOT Controller 120V 1 PH (750 3000) 240/480V 3 PH ( ) Direct spark ignition w/integrated flame sensor Modbus digital control system (standard) High Limit Control, Manual Reset 198º F Standard 155º F Low Temp 210º F High Temp Front mounted on/off power switch Live monitoring and control based on: Inlet gas pressure Fan outlet pressure Vent connection pressure and temperature Inlet and outlet water pressures and temperatures Up to (8) additional temperature sensors Unit Tag 3VO 750,000 4,000,000 BTU Gas Train Certified Seismic Rated Mounting Optional Controls Low Water Cut Off Gateway Communication BMS LONWorks BACnet MS/TP Manual Gas Shut-Off Valve(s) Negative Pressure Gas Valve(s) Fuel Field Adjustable w/no Parts Natural Gas Propane Gas CSD-1 No De-rate up to 9000' Additional Manual Reset High Limit Burner 316L Stainless Steel Premix Ultra-Low NOX: Less than 13 PPM, adjusted for 3% O2 Construction Indoor construction (standard) Outdoor construction (optional) 122 other protocols C/F Options Certified System UL 795 Number (includes all items listed below) Recirculating Pump Front Controls Modular Cabinet Rear Water Connections Rear Exhaust & Inlet Air Connections Automatic Air Vents Note: pumps are sized and supplied by factory as standard, providing 15% additional head for system connection piping. Condensate Neutralizer/Drain (highly recommended for all systems) Venting System Information Electrical Panel w/service Disconnects Common Gas Manifold Vent Termination PVC at setpoints up to 140 F CPVC Stainless Steel Polypropylene Pre-Plumbed Piping Manifold Expansion Tank - Direction of Termination Vertical Estimated Vertical Height: ft Horizontal Classified Commercial Industrial Gas Fired Heating Equipment PSI

Hamilton 3VO s 750 Q F R Outlet Inlet O P E B M N L J K I D A H C G F Q R Outlet Inlet E B O P N M L K J I A D H C A B C D E F G H I J K L G M N O P Q R Flue CondenWater Gas Outlet sate Conn. Conn. & Inlet Conn. Air Boiler Drain Conn. 750 26. 7 39" 3 69" 28. 10. 7" 1 17" 52" 63. 64. 9" 3. 2. 1.2 0.7 3 @ 0.7 850 26. 7 39" 3 69" 28. 10. 7" 1 17" 52" 63. 64. 9" 3. 2. 1.2 0.7 3 @ 0.7 1000 26. 7 39" 3 69" 28. 10. 7" 1 17" 52" 63. 64. 9" 3. 2. 1.2 0.7 3 @ 0.7 7" 3 @ 0.7 1500 32" 80" 5 47. 7 41" 1 7. 7. 1 21. 52" 61. 68. 13. 7" 3. 10" 1. 2000 32" 80" 5 47. 7 41" 1 7. 7. 1 21. 52" 61. 68. 13. 7" 3. 10" 1. 8" 3 @ 0.7 2500 32" 80" 5 47. 7 41" 1 7. 7. 1 21. 52" 61. 68. 13. 7" 3. 10" 10" 3 @ 0.7 3000 35. 88" 6 59. 84" 52. 18" 8. 8" 1 21. 52" 62. 76. 20. 7. 4" 11. 4" 10" 3 @ 0.7 35. 88" 6 59. 84" 52. 18" 8. 8" 1 21. 52" 62. 76. 20. 7. 4" 11. 4" 10" 3 @ 0.7 35. 88" 6 59. 84" 52. 18" 8. 8" 1 21. 52" 62. 76. 20. 7. 4" 11. 4" 12" 3 @ 0.7 Input BTU/hr Output BTU/hr @ 54ºF incoming water Output BTU/hr @ 120ºF incoming water GPH Recovery @ 100 F T Water Flow Rate & Pressure Drop @ 50 F T Water Flow Rate & Pressure Drop @ 20 F T Shipping Weight 750 747,684 736,469 669,177 884 28.5 @ 0.9' 71.3 @ 4.8' 1431 lbs 1451 lbs 850 848,561 835,833 767,948 1,003 32.3 @ 1.0' 80.8 @ 5.7' 1000 1,000,754 985,743 915,690 1,183 38.0 @ 1.3' 95.0 @ 7.0' 1463 lbs 1500 1,536,244 1,513,200 1,397,982 1,817 57.0 @ 1.1' 142.6 @ 6.19' 1639 lbs 2000 1,993,316 1,963,416 1,803,951 2,357 76.0 @ 1.5' 190.1 @ 8.2' 1688 lbs 2500 2,554,213 2,515,900 2,298,792 3,020 95.0 @ 1.7' 237.6 @ 9.5' 1731 lbs 3000 3,025,288 2,979,909 2,753,012 3,577 114.0 @ 1.6' 285.1 @ 8.9' 1860 lbs 3,437,291 3,385,732 3.093,562 4,065 133.1 @ 2.1' 332.6 @ 11.2' 1925 lbs 4,000,000 3,940,000 3,600,000 4,643 148.0 @ 2.4' 370.1 @ 13.3' 2500 lbs

RECOMMENDED SERVICE CLEARANCES RECOMMENDED SERVICE CLEARANCES (From side of unit) NOTE: The 3VO is rated at zero clearance to combustibles. Multiple 3VO appliances may be installed within of each other without compromising service clearance, 12" minimum is recommended for ease of wiring between units. 20" (From top of unit may be significantly reduced if fan and burner are disconnected during service) Holes in the rectangular tube bases can be fitted with supplied leveling bolts or can be used for standard or Seismic anchoring. 30" (From front of unit) (As required for piping and venting connections are on back of unit) (From side of unit) VENTING THE 3VO Please note: You MUST confirm local codes as related to venting materials, required markings, etc. Parts of Canada have very specific vent material requirements. Vent Diameter Standard Vent Type *For lengths greater than 100', consult factory. Optional Vent Type Minimum Combined Vent Length Maximum Combined Length 750 Stainless Plastic 6' + (2) 90º elbows 100'* 850 Stainless Plastic 6' + (2) 90º elbows 100'* 1000 Stainless Plastic 6' + (2) 90º elbows 100'* 1500 7" Stainless Plastic 6' + (2) 90º elbows 100'* 2000 8" Stainless Plastic 6' + (2) 90º elbows 100'* 2500 10" Stainless Plastic 6' + (2) 90º elbows 100'* 3000 10" Stainless Plastic 6' + (2) 90º elbows 100'* 10" Stainless Plastic 6' + (2) 90º elbows 100'* 12" Stainless Plastic 6' + (2) 90º elbows 100'* Note: For concrete construction or to meet certain fire codes, exhaust and inlet piping at the wall penetration to the EVO must be CPVC Schedule 40 or 80 or Stainless. The balance from the penetrated wall to the outside may be PVC Schedule 40 or 80.

ELECTRICAL CHARACTERISTICS FOR 3VO PRODUCTS Voltage Required Boiler Boiler Pump Voltage and Total Amps 750 120V Single Phase 120V@12A 120V@6A 120V@18A 750 240V@9A 240V@3A 240V@12A 850 120V Single Phase 120V@12A 120V@6A 120V@18A 850 240V@9A 240V@3A 240V@12A 1000 240V@9A 240V@3A 240V@12A 1500 240V@11A 240V@3A 240V@14A 2000 240V@11A 240V@5A 240V@14A 2500 240V@14A 240V@5A 240V@19A 3000 240V@14A 240V@8A 240V@22A 240V@8A 240V@14A 480V@5A 480V@11A and 240V@8A 240V@14A 480V@5A 480V@11A and Notes: 1. If customer chooses larger pump other than our default pump, Total Amps must be adjusted. 2. requires 120V-L1, 120V-L2, N, GND 3. 480V Current Draw will increase if Hamilton Engineering is providing a transformer in an electrical package to convert 480V to 240V.

ELECTRICAL REQUIREMENTS AND CONNECTIONS 3VO Terminal Wiring s Back side of appliance display panel Output Relays Located here Heat Demand 1 1 Additional Safety Heat Demand 2 2 Additional Safety Fault/Service 3 3 Cascade In (A) Fault/Service 4 4 Cascade In (B) E-Stop 5 5 Cascade Out (A) E-Stop 6 6 Cascade Out (B) PWM Pump Output 7 7 Outdoor Sensor PWM Pump Ground 8 8 Outdoor Sensor External Sensor 9 9 0 10 Vdc (+) External Sensor 10 10 0 10 Vdc (-) Tank Sensor 11 11 Room Thermostat Tank Sensor 12 12 Room Thermostat Empty 1 1 Power In 115VAC L Empty 2 2 Auxillary 115VAC L Pump P1 L 3 3 Auxillary 115VAC L Pump P1 N 4 4 Auxillary 115VAC L Pump P1 G 5 5 Auxillary 115VAC L Pump P3 L 6 6 Power In 115VAC N Pump P3 N 7 7 Auxillary 115VAC N Pump P3 G 8 8 Auxillary 115VAC N L 9 9 Auxillary 115VAC N 3-Way N/P2 N 10 10 Auxillary 115VAC N 11 11 Auxillary 115VAC N 3-Way G/P2 G 12 12 Power In 115VAC G 1 2 3 4 5 6 7 8 9 10 P3 P3 Relay Line P3 Relay Control N P3 3-Way/P2 Relay Line Terminal Block #1 3-Way /P2 Relay Control N Terminal Block #3 Terminal Block #2 Terminal Block #4 Terminal Block #5 Terminal Block 1 Terminals 1 & 2 Terminals 3 & 4 Terminals 5 & 6 Terminals 7 & 8 Terminals 9 & 10 Terminals 11 & 12 Heat Enable/Disable (Dry Contact) Fault alarm (Dry Contact) E-Stop (remote switch) current carrying - 0-5VDC For use with PWM boiler pump only Load (piping, Low Loss Header) sensor (T6) 10k Ohm Tank sensor (T3) here - 10K Ohm Terminal Block 2 Terminals 1 & 2 Additional safety circuit Terminals 3 & 4 Cascade in Terminals 5 & 6 Cascade Out Terminals 7 & 8 T4 Outdoor Sensor - 10k Ohm Terminal 9 0-10 VDC (+) Terminal 10 0-10 VDC (-) Terminals 11 & 12 Room Thermostat Terminal Block 3 Terminals 1 3 Terminal 4 Terminal 5 Terminal 6 8 Terminal 9 Terminal 10 Terminal 11 Terminal Block 4 Terminal 1 5 Terminal 6 11 Terminal Block 5 Terminals 1 10 Power to P1 Pump - 3 phase Not used for 3 phase - Neutral to P1 Pump Ground to P1 Pump Power to P3 115v pump or relay for 3 phase Line P2 Pump or NO terminal on 3 way valve - 115v Neutral on P2 Pump or 3 way valve 115v NC terminal on 3 way valve - 115v Ground on P2 pump or 3 way valve - 115v 115v Line - factory wired on 3 phase models 115v Neutral - factory wired on 3 phase models 115v Ground - factory wired on 3 phase models Factory Wired as standard - Relay Switching

ELECTRICAL REQUIREMENTS AND CONNECTIONS 3VO Terminal Wiring s Back side of appliance display panel Output Relays Located here Heat Demand 1 1 Additional Safety Heat Demand 2 2 Additional Safety Fault/Service 3 3 Cascade In (A) Fault/Service 4 4 Cascade In (B) E-Stop 5 5 Cascade Out (A) Terminal Block #1 E-Stop 6 6 Cascade Out (B) PWM Pump Output 7 7 Outdoor Sensor PWM Pump Ground 8 8 Outdoor Sensor External Sensor 9 9 0 10 Vdc (+) External Sensor 10 10 0 10 Vdc (-) Tank Sensor 11 11 Room Thermostat Tank Sensor 12 12 Room Thermostat Pump P1 L1 1 1 Power In 115VAC L Pump P1 L2 2 2 Auxillary 115VAC L Pump P1 L3 3 3 Auxillary 115VAC L Pump P1 N 4 4 Auxillary 115VAC L Pump P1 G 5 5 Auxillary 115VAC L Pump P3 L 6 6 Power In 115VAC N Pump P3 N 7 7 Auxillary 115VAC N Pump P3 G 8 8 Auxillary 115VAC N L 9 9 Auxillary 115VAC N 3-Way N/P2 N 10 10 Auxillary 115VAC N 11 11 Auxillary 115VAC N 3-Way G/P2 G 12 12 Power In 115VAC G 1 2 3 4 5 6 7 8 9 10 P3 P3 Relay Line P3 Relay Control N P3 3-Way/P2 Relay Line 3-Way /P2 Relay Control N Terminal Block #3 Terminal Block #2 Terminal Block #4 Terminal Block #5 Terminal Block 1 Terminals 1 & 2 Terminals 3 & 4 Terminals 5 & 6 Terminals 7 & 8 Terminals 9 & 10 Terminals 11 & 12 Heat Enable/Disable (Dry Contact) Fault alarm (Dry Contact) E-Stop (remote switch) current carrying - 0-5VDC For use with PWM boiler pump only Load (piping, Low Loss Header) sensor (T6) 10k Ohm Tank sensor (T3) here - 10K Ohm Terminal Block 2 Terminals 1 & 2 Additional safety circuit Terminals 3 & 4 Cascade in Terminals 5 & 6 Cascade Out Terminals 7 & 8 T4 Outdoor Sensor - 10k Ohm Terminal 9 0-10 VDC (+) Terminal 10 0-10 VDC (-) Terminals 11 & 12 Room Thermostat Terminal Block 3 Terminals 1 3 Terminal 4 Terminal 5 Terminal 6 8 Terminal 9 Terminal 10 Terminal 11 Terminal Block 4 Terminal 1 5 Terminal 6 11 Terminal Block 5 Terminals 1 10 Power to P1 Pump - 3 phase Not used for 3 phase - Neutral to P1 Pump Ground to P1 Pump Power to P3 115v pump or relay for 3 phase Line P2 Pump or NO terminal on 3 way valve - 115v Neutral on P2 Pump or 3 way valve 115v NC terminal on 3 way valve - 115v Ground on P2 pump or 3 way valve - 115v 115v Line - factory wired on 3 phase models 115v Neutral - factory wired on 3 phase models 115v Ground - factory wired on 3 phase models Factory Wired as standard - Relay Switching